Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 IN I 2 L 3 I NC0086797 111 121 21/02/25 117
Type
18 H
IIIIIIIIIII
Inspector Fac Type
19 I S I 201 I
21IIIIII IIIIIIIIIIIIIIIIII I IIIIII
P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
671 I 70 I3 I 711 1 72 I N I 73 _ I 74 71
I I
I I I I I I 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
River Bend WTP 1 & 2
45 Shoreline Dr
New Bern NC 285628970
Entry Time/Date
01:OOPM 21/02/25
Permit Effective Date
18/08/01
Exit Time/Date
02:30PM 21/02/25
Permit Expiration Date
23/05/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Brandon Dwight Mills/ORC/252-638-3540/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Brandon D Mills,45 Shoreline Dr New Bern NC 285628970/Director of Public
Works/252-638-3870/ No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Robert B Tankard DWR/WARO WQ/252-946-6481 Ext.233/
Victoria Herdt DWR/WARO WQ/252-948-3911/ l‘cf o a C Fi4A. 03/17/2021
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page# 1
31
NPDES yr/mo/day
NC0086797 111 121 21/02/25
117
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
February 25, 2021 Victoria Herdt and Robert Tankard conducted a compliance inspection. Also present
was ORC Brandon Mills. The June and November 2020 DMRs were spot checked for discrepancies
with no errors found.
The facility was found to be in Compliance with NC0086797.
Page# 2
Permit: NC0086797
Inspection Date: 02/25/2021
Owner - Facility: River Bend WTP 1 & 2
Inspection Type: Compliance Evaluation
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc
on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification'
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ • ❑
•
•
•
•
Comment: Brandon Mills is ORC and Thomas Harper is the Back Up ORC.
June and November 2020 DMRs were spot checked for discrepancies with no
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
El
Yes
•
•
•
•
El
❑ ❑ ❑
❑ ❑ ❑
El El El
El El El
errors found.
No NA NE
❑ ❑ ❑
El El El
El El El
❑ ❑ ❑
Comment: Facility is Field Parameter Certified and all other samples are sent to Environmental
Chemists.
Page# 3
Permit: NC0086797
Inspection Date: 02/25/2021
Owner - Facility: River Bend WTP 1 & 2
Inspection Type: Compliance Evaluation
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Comment:
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: Permit for WTP 1 and 2 expires May 31, 2023.
Yes No NA NE
• ❑ ❑ ❑
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Chemical Feed Yes No NA NE
Is containment adequate? • ❑ ❑ ❑
Is storage adequate? • ❑ ❑ ❑
Are backup pumps available? • ❑ ❑ ❑
Is the site free of excessive leaking? • ❑ ❑ ❑
Comment:
De -chlorination Yes No NA NE
Type of system ? Liquid
Is the feed ratio proportional to chlorine amount (1 to 1)? • El El El
Is storage appropriate for cylinders? ❑ ❑ • ❑
# Is de -chlorination substance stored away from chlorine containers? • ❑ ❑ ❑
Comment:
Are the tablets the proper size and type? ❑ ❑ • ❑
Are tablet de -chlorinators operational? ❑ ❑ • ❑
Number of tubes in use?
Comment:
Equalization Basins
Is the basin aerated?
Yes No NA NE
❑ • ❑ ❑
Page# 4
Permit: NC0086797
Inspection Date: 02/25/2021
Owner - Facility: River Bend WTP 1 & 2
Inspection Type: Compliance Evaluation
Equalization Basins Yes No NA NE
Is the basin free of bypass lines or structures to the natural environment? • ❑ ❑ ❑
Is the basin free of excessive grease? • ❑ ❑ ❑
Are all pumps present? • El El El
Are all pumps operable? • ❑ ❑ ❑
Are float controls operable? • ❑ ❑ ❑
Are audible and visual alarms operable? ❑ ❑ ❑ •
# Is basin size/volume adequate? • ❑ ❑ ❑
Comment: The equilization basin is a settling basin before discharge.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: In -line mag meter used for recording discharge flow.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: Sample temperature at WTP 1 is 5 degrees C and WTP 2 is 4 degrees C.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment:
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ • ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
Page# 5