Loading...
HomeMy WebLinkAboutwq0042333_Application (FTSE)_20210215State of North Carolina nWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-I6 & SUPPORTING DOCUMENTATION Application Number: {iV 0 �� (t) be L;omplcled by DWR) All items must be completed or the a licalion will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Johnston Countv (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State'County ® Municipal 3. Signature authority's name: Chandra Farmer. P.E. per 15A NCAC 02T .0106 b Title: Director of Public Utilities 4. Applicant's mailing address: Post Office Box 2263 City: Smithfield State: NC Zip: 27577 5. Applicant's contact information: Phone number: (919) 209-8333 Email Address: chandra.farmer! johnstonnc.com [I. PROJECT INFORMATION: ❑ Privately -Owned Public Utility ❑ Other NC Dept of Environmental Quality FEB 15 2021 Meigh Regional Office I. Project name: Bratton Drive Extension 2. Application, Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00_ and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Johnston 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.6104 Longitude:-78.5643 5. Parcel ID (if applicable): 162700-98-3509 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I . Professional Engineer: Jerry T. Dalton License Number: 16282 Firm: Dalton Eneineering and Associates. P.A. Mailing address: Post Office Box 426 City: Clayton State: NC Zip: 27528- Phone number: (919) 5504740 Email Address: idalton(adaltonengineerine.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: I. Facility Name: Johnston County -Regional Central Treatment Plant Permit Number: NCO030716 Owner Name: Johnston Countv V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0016720 Downstream (Receiving) Sewer Size: 8° inch Svstem Wide Collection System Permit Numbers ifa iicable : WQCS00060 Owner Name(s): Johnston County FORM: FTA 04-16 Pale l of V1: GENERAL 11 QUIREVIENTS 1. 1ftjte Applicant is a Privately -Owned Public Utility, has a Certificate ofPublie Convenience and Necessity been attached.' ❑ Yes ❑No ❑N. A If the Applicant is a Developer of lots to be sold, has a De%elo er's Operational Agreement FORM. DEV been attached" ❑ Yes ❑No QN+A . Ifthe Applicant is a Home Pro ertm 0%%ner5' Association has an Operational Agreement tFOR.M. HOA been attached' ❑ Yes ❑No ONfA 4 Origin ol-wastewater. (check all that apply); ❑ Residential Owned El Retail (stores, centers, malls) ❑ Residential Leased ❑ Retail with food preparation'service ❑ School..' preschool:' day care ❑ Medical / dental / veterinary facilities ❑ Food and drink facilities ❑ Church x❑" Businesses r ofiict±s factories ❑ Nursin=_ Home 5 Nature of wastewater : 0 ° ° Domestic/Commercial 100 °°Commercial ❑ Car Wash ❑ Hotel and -or Motel, ❑ Swimming Pool 'Clubhouse ❑ Swimming Pool'Filter Backwash ❑ Other (Explain in Attachment) 0 °d Industrial (See 15A NCAC 02T .0103120)) Is there a Pretreatment Program in effect? El Yes ❑ No 6. Has a flow reduction been approved under 1I5A NCAC 02T .01 141ft? ❑ Yes [I No f Ifves. Provide a copy of flow reduction apiwoval letter 7. Summarize wastewater generated by project: Establishment Type (see U2T.0114ff)) Commercialuse Daily Design Flow °'' L200!_al/day/acre No. of Units '_.I acres Flow I 15206PD ��al/ GPD =fah GPD GPD -al! GPD i Uall GPD Total 2.520 GPD a See 15A NCAC t)?T .0114(b). d . e I and e 3 for caveats to wastewater design flow rates ( i.e., minimum now per dwellin�o: proposed unknown non-residential development uses: public access facilities located near high public use areas: and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S.- 42A-4). b Per 15A NCAC 02T _01 14(c). design flow rates for establishments not identified [in table 15A NCAC 02T.01 141 shall be deten-tined using available flow data. water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project: ? 520 GPD (per 15A NCAC 02T._qJL4) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number- ❑ Rehabilitation or replacement of existing sewer with no new (low expected ❑ Other (Explainl; _ . FORM vrA 04-16 Pau e'_ of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .030* & .-M0C (Grai iti Seiierti): I Summarize �gravtty sewer to be permitted FSize (inches) Length (feet) Material 8.1 -id 7 PVC Section 11 & III of -the MDC for Permitting of Gravity Sewer; contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VI?L PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & _MDC (Pump StationslForce Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I Pump station number or name- 2. Approximate Coordinates (Decimal Degrees); Latitude- _. Longitude- 3 Design flow of the pump station. � millions gallons per day (firm capacity) 4_ Operational point(s) ofthe pump(s): !gallons per minute at feet total dynamic head (TDI-II 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) ,'Material II 6_ Power reliability in accordance with I5A NCAC 02-r .0305 h ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T.0305(h)( I )(13): Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day Must be permanent to facility Or if the pump station has an average daily now less than 15,000 gallons per day: ❑ Portable power source with manual activation. quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)( I )(C) or ❑ Portable pumping unit with piug0ed emergency pump connection and telemetry - 15A NCAC 02T .0305(h)( I )(C): { It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. f If the portable power source or pump is dedicated to multiple pump stations. an evaluation of all the pump stations storage capacities and the rotation schedule ofthe portable power source or pump, including travel timel'rames, shall be provided in the case of a multiple station power outage. FOR.*A f TA 04- f 6 Page ± of 5 IX: SETBACKS .% SEPARATIONS — (02B .0200 & 15A NCAC 02T .03t15(l)): 1 Does the project comply with all separations found in 15.4 NCAC 0'_T . )305 t & «! 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer F Setback_ Parameter* Storm sewers and other utilities not listed below (vertical)__ Water mains (vertical -water_ over sewer includin+i in benched trenches) Watermans(horizontal) Reclaimed water lines (vertical - reclaimed over sewer) _ Reclaimed water lines (horizontal - reclaimed over sewer) [] Yes [:]No Serration Required 4 inches ~ IS inches _ 10 feet Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinkim" water _ **Waters classified WS (except WS-1 or WS-V), B, SA, CRW, HQW. or SB from normal high water (or tide elevation) and wetlands (see item IX-2) **Anv other stream. lake, impoundment, or ground water lowering and surface draina�,e ditches An building foundation Anbasement _ To s!p ode of embankment or cuts of 2 feet or more vertical height D�rama4ge systems and interceptor drains Anv swimmin+� pools ._ _ Final earth +grade (vertical) 18 inches I 2 feet 100 feet 50 feet 10 feet 5 feet 10 feet 10 feet 5 feet 10 feet 36 inches _ J 15A NCAC 02T.OWtot�o contains alternatives where separations in 02'FT030 4 cannot be achieved, **stream classifications can be identified using the Division's V( Surface -1h ater Classifications ►%e+ j2a�.e If noncompliance with 92T-0305if) or tat, see Section X of this application 2. Does the project comply with separation requirements for wetlands" (50 feet of separation) ❑ Yes ❑ No ❑ N.-A See the Division's draft separation requirements for situations where separation cannot be meet No variance is required if the alternative design criteria specified is utilized in desien and construction As built documents should reference the location of areas effected 3 Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? 0 Yes ❑ No ❑ N. A This would include Trout Buffered Streams per I5A NCAC 2B.0202 4, Does the project require co veragelauthorization under a 404 Nationwide or ❑X Yes ❑ No individual permits or 401 Water Quality Certifications`' Information can be obtained from the 40; R Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105 c 6) (additional permits certifications)? ❑X Yes ❑ No Per 15A NCAC 02T.0103(c)16t, directly related environmental permits or certification applications are being prepared. have been applied for. or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans. stonnwater management plans. etc.). 6, Does this project include any sewer collection lines that are deemed "high -priority?" Per ! 5A NCAC 02T.0402. "Itigh-priority sewer" ineans "any aerial sewer. sewer conlactin�, surface waters. siphon. or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes © No ❑ N?A If ves. include an attachment with details Ibr each line. including, type (aerial line, size, material. and location). High priority lines shall he inspected by the permilice or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM FTA 04-16 Pauc 4 of 5 V. CEt2T1FICATIONS: Does the submitted system comply with 15A NCAC 02T, the �linrmum Deli<,n Criteria for the Perntittlne of Pum Stations and 4 orce ,Nlain; J latest %ersion and the Gravit. Server Minimum Design Criteria (latest,~ � rsionas applicable" Q Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting for review. Approval of the re nest is re aired rior to submittal aF the Fast Track A lication and sdocuments documents. ?. Professional Engineer's Certification: /c� - attest that this application for (Professional Engineer's name from Application Item Ill. 1. ) has been reviewed by me and is accurate, complete and consistent with the informa?ion supplied in the plans, specifications. engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the hest of my knowledge the proposed design has been prepared in accordance with the applicabl,- regulations, Gravity Sewer Minimum Desi__n Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Past -Track Permitting, of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE In accordance with General Statutes 1=43-215.6A and 1=43-21i,613_ any person who knowingly ma any false statement, representation, or certification in any application package shall be guilty of a Class mifc em or. which may include a tine not to exceed S 10.000. as well as civil penalties up to S35,000 per violation. J� North Carolina Professional Engineer's seal, signature, and date: 10 dot/�••FJVGtNti�'•'� `�lIl1,Ll.4l1 3. Applicant's Certification per 15A NCAC 02T .0106(b). Lhmda, axrni _a _ �- �__. �Item attest that this application for (Signature Aut tority s name R title from Applicat,3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included. this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties. injunctive relief. and -or criminal prosecution. 1 will male no claim a4eainst the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments me as incomplete_ are not included. this application package will be returned to NOTE In accordance with General Statutes 143-215.6A and I-13-2 15.6B. any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class ? misdemeanor. which may include a tine not to exceed S 10.000 as well as civil penalties up to 535.000 per violation. r Signature: Date: �E5 1 a 1 FORM FTA04-16 Parr * of 5 XMMWmr--!' NC Dept of Fnvironmental Quality State of North Carolina DWR Department of Environmental Quality FL13 15 2921 Division of Water Resources Division of Water Resources Fin I (eign i .1.0calpftce for Sewer Extension Applications (FTSE 04-I6) Entity Requesting Allocation: Johnston County Project Name for which flow is being requested: Bratton Drive Extension More than one FTSE mat- he required for a single project if the owner of the JVIVTP is not responsible, for all pirnrp stations along the route of the proposed wasteivater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Central Johnston County WWTP b. WWTP Facility Permit #: NC0030716 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. TotaI flow for this specific request g. Total actual and obligated flows to the facility A11 flows are in MGD M 1.904 7.091 0.00252 8.997 h. Percent of permitted flow used 74.6% trio, 94.7% paper H. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Average Daily Approx_ Not Yet "Total Currcnt Station Firm Flow** Current Avg, Tributary Flow Plus (Name or Capacity, * (Firm { p0, Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** Swift Greek— 1.764 0.7056 0.3313 0.2753 0.6065 0.0991 Josephine 3.384 1.3536 0.7524 0.4249 1.1773 0.I763 Landfill 1.9296 1.6718 0.9282 0.6259 1.554I 0.1177 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pi) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): River Oaks Commercial Park Downstream Permit Number: WQOO16720 Page I of 1 FTSE 04-16 111. Certification Statement: i Chandra C. Farmer, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which i am the responsible party. Signature of this form indicates acceptance of this wastewater flow. Signing Official Page 2 of I FTSE 04-1 d Dalton Engineering and Associates, PA. 2113l21 NC Deer o�En yirah NCDEQ EAST TRACK APPLICATION ( FTA 04-16) FES Quali0 Sub. Bratton Drive Extension far 5 2�7� JohnstonRiver Oaks Commercial Park County, North Carolina e1g� Reg�on$1 office lee Developer: Son -Lan Classic Development Co., L.L.C. 2701 Polenta Road Clayton, North Carolina 27520 Son -Lan Classic Development Co., L.L.C. is proposing to develop Bratton Drive Extension, which is located within the River Oaks Commercial Park. The Commercial Park is located in the Northeast quadrant of the intersection of Interstate 40 and NC Highway 42 West. The project comprises of 2.1 acres of property, which is anticipated to be developed with uses similar to the adjacent commercial lots ( otiice space and community -related businesses ). The project will consist of the construction of a roadway that will provide access to the property with storm drainage and curb and gutter, a water system extension and a gravity sanitary sewer system extension. If there are any questions or comments, please do not hesitate to call. Thank you. ra►--- Jonathan B es 446 East Main Street &, P.O, Box 426 � Clayton, NC 27528 � (919) 550-47401Fox (919) 500-4741 CM co