Loading...
HomeMy WebLinkAboutWI0700031_Inspection_20210311North Carolina Department of Environment and Natural Resources Division of Water Quality — Aquifer Protection Section INJECTION FACILITY INSPECTION REPORT PERMIT NO. WI0700031 DATE OF INSPECTION: 3/8/21 INSPECTOR: R. Sipe NAME OF PERMITTEE(S) Anthony and Denise Canino MAILING ADDRESS OF PERMITTEE 101 Channel Run, Washington, NC 27889 PHYSICAL ADDRESS OF SITE (if different than above) Same as above PERSON MET WITH ON -SITE Anthony Canino; TELE NO. (601)761-0101 WELL(S) STATUS: XExisting and operating Class V Well Existing well proposed to be converted to Class V well Proposed/not constructed LAT/LONG OF WELL(S) 35.494167N, 76.953056W (Inj. Well) Appx. distance of well to property boundaries: 15 feet (Inj. Well) Appx. distance of well from foundation of house/structure: _50 feet (Inj. Well) Appx. distance of well from septic tank/field (if present): _84 feet (Inj. Well) Appx. distance of well to other well(s) (if present): 150 feet to supply well Appx. distance to other sources of pollution: None Flooding Potential of Site: high moderate Xlow Comments: Both inj., and supply wells appear to be in good condition consistent with findings of prior inspection and operating adequately. Injection Facility Insp. Report (Rev. Sept 2009) Page 1 of 4 Pages Injection Facility Insp. Report (Rev. Sept 2009) Page 2 of 4 Pages See Attached Map DRAW SKETCH OF SITE ABOVE (Show property boundaries, buildings, other wells, septic tanks/drain fields, other potential pollution sources, roads, approximate scale, and NORTH arrow) N/A (not determined during this permit renewal inspection) Draw Schematic of well above showing TD, casing depth, grout, etc. Injection Facility Insp. Report (Rev. Sept 2009) Page 3 of 4 Pages Well Construction Information Date Constructed: 10/27/2000 Well Contracting Company: _Taylor Well Systems Well Driller Name: John Taylor NC Well Cert. No.: _2435-A Address:_2030 Taylor Rd., Chocowinity, NC 27889 Telephone No.: ; Cell No.: Email Address: Proposed Depth of Well(s): Total Depth: _90 feet Total Depth of Source Well, if present:_80 feet Casing: Depth: 53 feet; Diameter: 4 inches ; Type (gay. steel, PVC, etc.): PVC ; Stick Up: 12+ inches ft Grout: Depth: Unk. (not determined during this permit renewal inspection); Type (cement, bentonite, etc.):_Unk. ; Placement (pumping, press. etc.): _Unk. Well ID Plate Present (Y or N): Y ; Heat Pump ID plate present (Y or N): N Influent spigot (Y or N): Y Effluent spigot (Y or N): Y Well Sampled? (Y or N): N ; If Yes, Lab Sample ID numbers: N/A Static Water Level: Not Measured Injection Information (if applicable): Injection Rate: GPM Injection Pressure: PSI Injection Volume: GPD Temperature- Summer: F° Temperature- Winter: F° Comments/Notes: Both inj., and supply wells appear to be in good condition consistent with findings of prior inspection and operating adequately. Injection Facility Insp. Report (Rev. Sept 2009) Page 4 of 4 Pages Injection Facility Insp. Report (Rev. Sept 2009) Page 5 of 5 Pages