Loading...
HomeMy WebLinkAboutWQ0042374_Application (FTSE)_20210309it Dewberry® TRANSMITTAL DATE: March 04, 2021 PROJECT NAME: R-5737 Davidson County 'V PROJECT#: 50084275 RE: NCDEQ Fast Track Sewer Permit TO: Lon Snider, Regional Supervisor NCDEQ — Water Quality Section 450 West Hanes Mill Road, Suite 300 Winston-Salem, NC 27105 PHONE: 336.776.9700 CC: J Separate cover U.S. mail Messenger 1 Pick up x Overnight carrier Hand d - elivery !I Prints Product literature X-1 Copies Computations ------- Reports rI CDs/DVDs Studies Other Reproducible I 1 12.22.211 $480 - Application Fee 2 3.04.21 Fast Track Sewer System Extension Application Package 2 3.04. 17-t 21 Utility Construction Plans Comments Please find enclosed the above referenced documents. Call with any questions. Thank you! Received: Lon Snider Regional Supervisor 450 W Hanes Mill Rd., Suite 300 Winston-Salem, NC 27105 336.776.9700 Signed: Timothy J. Ritacco, PE Project Manager 2610 Wycliff Road, Suite 410 Raleigh, NC 27607 984.255.7052 If enclosures are not as noted, please notify us at once 1 OF 1 It Dewberry® March 4, 2021 North Carolina Department of Environmental Quality Winston-Salem Regional Office Water Quality Section 450 W. Hanes Mill Road Suite 300 Winston-Salem, NC 27105 Dewberry Engineers Inc. 919.881.9939 2610 Wycliff Road, Suite 410 919.881.9923 fax Raleigh, NC 27607 www.dewberry.com RE: 15A NCAC 02T .0300 — Fast Track Sewer System Extension Application One behalf of our client, the City of Thomasville, Dewberry has prepared the Fast Track Sewer System Extension Application. The purpose of the gravity sewer replacement is to relocate existing utilities that conflict with and will be performed as part of the North Carolina Department of Transportation's (NCDOT) Project R-5737• The project is strictly a relocation project, meaning no new services or flow increases are anticipated. Therefore, a Flow Tracking/Acceptance form is not needed because no new services or flows are being added to the relocated gravity main. This Fast Track Sewer System Extension Application is to permit this gravity sewer relocation. The City has a system -wide collection system permit number WQCS00057 and therefore, we have provided this information under Section 5 of the FTA and left the existing permit number blank under Section 2 of the FTA application. Enclosed for your review are one (t) original and (1) copy of the following: • Fast Track Sewer System Extension Application • Application Fee of $480.00 • One USGS Topographic and Street View Map of project area Should you have any questions or comments please to not hesitate to call our office at (984) 255-7052 or email me at tritacco(@dewberry.com. Sincerely, 3/4/2021 X TimothyJ.Ritacco Timothy J. Ritacco, PE Protect Manaqer Siqned by TimothyJ Ritacco Dewberry Engineers Inc. Enclosures Cc: Larry W. Mitchell, Dewberry Page 1 of 1 State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DwR) AR items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: City of Thomasville (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: Michael Brandt per 15A NCAC 02T .0106(b) Title: City Manager 4. Applicant's mailing address: P.O. Box 368 City: Thomasville State: NC Zip: 27361-0368 5. Applicant's contact information: Phone number: 3( 36) 475-5599 Email Address: michael.brandtAthomasville-nc.gov ❑ Privately -Owned Public Utility ❑ Other II. PROJECT INFORMATION: 1. Project name: R-5737 2. Application/Project status: ❑ Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000 and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: Davidson 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.8668' Longitude:-80.1808' 5. Parcel ID (if applicable): N/A (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Timothy J. Ritacco License Number: 046000 Firm: Dewberry Engineers Inc. Mailing address: 2610 Wycliff Road, Suite 410 City: Raleigh State: NC Zip: 27607-3073 Phone number: 984 255-7052 Email Address: tritaccoAdewberry.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Hamby Creek W WTP Permit Number: NCO024112 Owner Name: City of Thomasville V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ_ Downstream (Receiving) Sewer Size: 12 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00057 Owner Name(s): City of Thomasville FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes [—]No NN/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes []No NN/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No NN/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased N Retail with food preparation/service ❑Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial 0 % Commercial 0 % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes N No 6. Has a flow reduction been approved under 15A NCAC 02T .0I14(fl? ❑ Yes N No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f) Daily Design Flow $b No. of Units Flow No additional flow generated 0 gal/min 0 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total GPD a See 15A NCAC 02T 0114 b(__). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: _ GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: N Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VH. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 504 PVC ➢ Section II & III of the. MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section HI contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing Hues to meet minimum slope requirement is not allowed and a violation of the MDC VHL PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: _ millions gallons per day (fora capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305( & (e) ® Yes ❑ No ➢ 15A NCAC 02T.0305(fl contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top sloe of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305( or (a), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ®N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 0213.0200? [-]Yes ❑ No ®N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes []No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is reauired prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: I Timothy J. Ritacco attest that this application for Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. ........................................................................................ . North Carolina Professional Engineer's seal, signature, and date: inb9Aryo1 3. Applicant's Certification per 15A NCAC 02T .0106(b): Michael Brandt, City Manager attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Michael M. Brandt Date: l021.0.4gned y 0:32:3 -0 Brandt 03/04/2021 Date: 2021.03.04 10:32:35-O5'00' Date: FORM: FTA 04-16 Page 5 of 5 f t kd q N ri L;fi. q C a � i � S L Y M O N ryp iu 9: f r•. r. IS S {4 . �1} b e•, Y • r eryy E � r.y • • f � { m