Loading...
HomeMy WebLinkAbout20021157 Ver 4_Pre-Filing Meeting Request_20210213ID#* 20021157 Version* 4 Regional Office* Washington Regional Office - (252) 946-6481 Reviewer List* Robert Tankard Pre -Filing Meeting Request submitted 2/13/2021 Contact Name * Contact Email Address* Project Name* Project Owner* Project County* Owner Address: Brian Rubino brubino@quible.com Lot 66 Beachside Extension Sarah and Christopher Folliard Hyde Street Address 7751 Cheathams Rd. Address Line 2 aty Amelia Courthouse Rbstal / Zip Code 23002 Is this a transportation project?* r Yes r No State / Frovince / Region VA Country USA Type(s) of approval sought from the DWR: W 401 Water Quality Certification - F 401 Water Quality Certification - Regular Express r- Individual Permit r- Modification r- Shoreline Stabilization Does this project have an existing project ID#?* r Yes r No Please list all existing project ID's associated with this projects.* 401 Cert 02-1157 Do you know the name of the staff member you would like to request a meeting with? Chris Pullinger Please give a brief project description below.* Chris, This is a lot that had a prior 401 cert in 2006 for the previous owner. Authorized 404 fill impacts for this lot at that time were 0.05 acres of 404 wetlands. The prior owner performed the permitted fill (but did not build) after fulfilling mitigation requirements through NCEEP (currently NCDMS). The 401 approval for this project included Lots 66 and 58 (both owned by Ann Warner at the time). Total permitted fill was 0.09 acres in 2006 (0.05 acres for Lot 66 and 0.04 acres for Lot 58). This also received a Nationwide 18 Permit. Now, the owners of Lot 66 are Sarah and Chris Folliard. They would like to build a residential home that has been designed, and in order to do this, they propose to fill and additional 400 sq.ft. (.009 ac) of 404 wetlands as shown on the attached plan. I have been in communication with Billy Standridge, USACE about this current request. This is not a waterfront property and constitutes less than 0.1 ac of wetlands total (past and current permit request combined). I believe this to be notification to DWR only, but am available to meet if necessary. Thanks, Brian Rubino Please give a couple of dates you are available for a meeting. 2/25/2021 2/15/2021 Please attach the documentation you would like to have the meeting about. hines-pamlico point -lot 66-rev prelim-01 -31 - 625.09KB 21.pdf USGS_OCRACOKE.pdf 1.14MB NRCS_Soi I_Ma p. pdf 320.16KB pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature Submittal Date 2/13/2021 PAMLICO SOUND SILVER LAKE WEST END ROAD VICINITY MAP OCRACOKE ISLAND PAMLICO SOUND CENTRAL DRIVE N.C. HWY. 12� IRVIN GARRISH HIGHWAY SITE DEVELOPMENT NOTES 1. Subject Property: Lot 66, Pamlico Point Beachside Extension Ocracoke Island, Hyde County, North Carolina Street Address: (not assigned) Lake Drive, Ocracoke, NC Recorded: P.C. A SL. 69132 Hyde Co. Register of Deeds PIN 9500-67-1939 2. Zoning: Article VIII — Ocracoke Development 3. Lot Area = 6,750 SQ. FT. (0.15 acres) 4. FEMA Data: Hyde County CID 370133 Panel 9500 Suffix K Map Number 3720950000K Effective Date : 6/18/2020 Vertical Datum NAVD 1988 FIRM Zone AE (4') + 1 freeboard = 5' 1' Freeboard Required by Hyde County Ordinance Chapter 20 Reference Level is top of lowest floor Flood Zones subject to change by FEMA 5. Area computed by coordinates Elevations referenced to NAVD 1988 Vertical Datum 6. Building Setbacks (per Hyde Zoning X Chapter 36) Hyde County Chop ter 36, Article Vlll) Minimum Front Setback: 8' Minimum Side Setback: 8' Minimum Rear Setback: 8' 7. Lot Coverage Calculation: Total Lot Area = 6,750 sq. ft. Proposed Lot Coverage Summary: Building and Decks = 1,661 sq. ft. Concrete drive and parking = 740 sq. ft. HVAC Stand = 30 sq. ft. Total coverage = 2,431 sq. ft. (36.0%) Maximum coverage = 50% of lot area Maximum coverage = 3,375 sq. ft. TREATMENT STANDARD PROPOSED — TS-1 (TERTIARY TREATMENT WITHOUT NITROGEN REDUCTION) TREATMENT SYSTEM PROPOSED — Puraflo PEAT BIOFILTER SYSTEM INNOVATIVE APPROVAL NO. IWWS-98-1—R3 IMPORTANT NOTICE TO OWNER FROM INNOVATIVE APPROVAL - The Puraflo Peat Biofilter is a pre—engineered proprietary treatment system. The containment modules are made of pre —assembled, UV —protected polyethylene material, with approximate dimensions of 7.08 feet long by 4.58 feet wide by 2.5 feet deep. The modules are fitted with UV —protected, removable polyethylene lids, which contain ventilation and drain holes. Each module in the system is installed at the exact same elevation, with effluent flow uniformly split between the separate modules. The fibrous peat treatment media is residues of Eriophorum (Cotton Grass) plants, extracted from raised bog peats (other natural residues and peat fines are also present). The estimated life of the peat media Is currently 15 years. The media may need to be replaced, in part or in full, In order to maintain specified treatment standards (see note below) TREATMENT PERFORMANCE STANDARDS (TS-1): Tertiary treatment without nitrogen reduction. The Puraflo Peat Biofilter shall be designed, installed and operated to meet the following standards: 1. Biochemical Oxygen Demand, 5—day (BOD5) < 15 mg/L 2. Total Suspended Solids (TSS) < 15 mg/L 3. Ammonium —nitrogen (NH4—N) <10 mg/L 4. Fecal coliform bacteria densities < 10,000 colonies/100 ml (MPN) Standards are arithmetic means, except fecal coliforms is a geometric mean. System classification, management and inspection shall be in accordance with Rule .1961. Puraflo Peat Biofilters shall be classified at a minimum as a Type Va system according to Table V(a) of Rule .1961(b). System Inspections: Both the local health department and the operator —in —Responsible Charge (ORC) must conduct monitoring inspections of Puraflo Peat Biofilter Systems at a minimum frequency as specified in Table V of Rule .1961(b) and the Operation Permit. THIS SYSTEM REQUIRES REGULAR INSPECTIONS BY THE DARE COUNTY HEALTH DEPARTMENT AND THE OPERATOR —IN RESPONSIBLE CHARGE ORC . THE OWNER IS REQUIRED TO CONTRACT WITH A QUALIFIED ORC AND WILL B RESPONSIBLE FOR FEES ASSOCIATED WITH THE CONTRACT AS WELL AS FEES ASSOCIATED WITH ROUTINE WASTEWATER SAMPLING AND TESTING. THE DARE COUNTY HEALTH DEPARTMENT ALSO CHARGES YEARLY INSPECTION FEES. IN ADDITION THE OWNER SHOULD BE AWARE THAT THE TREATMENT MEDIA HAS A LIMITED LIFESPAN AND MUST BE REPLACED AS NEEDED TO MAINTAIN THE SPECIFIED TREATMENT STANDARDS. DISCUSSIONS WITH SEVERAL LOCAL OPERATORS AND INSPECTORS INDICATE THE LIFE SPAN OF THE PEAT IS SUBSTANTIALLY LESS THAN THE 15 YEARS NOTED IN THE INNOVATIVE APPROVAL. THIS APPEARS PARTICULARLY IN SEASONAL RENTAL PROPER77ES WHERE THE ACTUAL FLOW EXCEEDS THE DESIGN FLOW DUE TO OCCUPANCY LEVELS EXCEEDING THE DESIGN STANDARD OF TWO PERSONS PER BEDROOM. 77-IE PROPERTY OWNER IS ADVISED TO S7RIC7LY ENFORCE OCCUPANCY STANDARDS ESPECIALLY IF THIS PROPERTY IS USED AS A VACA77ON RENTAL. / / / / / / / LAKE DRIVE D SITE Cn PROPOSED CONCRETE / DRIVEWAY 6" THICK, 4,000 PSI) / 4 PROPOSED PARKING SPACES \ / 10'x 20' EACH \ \ � w 3t,�w PUMP,SANK n "E61DGE C6ApED � SEPTIC TANK ` BRIDGE LOADED_ 4" SON 80 AT 1%\ PROPOSED / LOT 64 / M FILLED ELEVATIONS\ PAMLICO POINT / P.C. A SL. 6962 / i 5.0' 4.0' 3.0' / PROPOSED RESIDENTIAL DWELLING � / TWO STORY FRAME— 4 BEDROOM ;N / AVERAGE GROUND ELEVATION — 2.0' +/— / FILL BUILDING PAD 36" TO 5.0' PROPOSED LOWEST FLOOR ELEV. = tbd' +/— / / LOT 65 PAMLICO POINT \ / / P.C. A SL. 6962 \ / PROPOSED RETAINING WALL \ / TOP OF WALL VARIES 5.0' TO 2.0'996' i \ EXISTING ACOE WETLAND LINE \ / i / / / / / / / / / / / / \OAOWq Y / / / / LOT 76 / PAMLICO POINT / P.C. A SL. 69B2 / / / LO / PAMLI P.C. A / / / / / / / CONTROL PANEL \`I 'I` AND VENT \ 2" SCH 80 PVC \ ; FORCE MAIN FENCE REQUIRED `POST/ROPE MIN. ELECTRIC RON ROD o '?o• 8' FRONT SETB o• i / '�' ,�•W EDGE OF GR4`VEL BED PURAFLO POO (TYPICAL) Ak AIL AIL AL \ T / 77 / CO POINT / SL. 69B2 / / / / / / / / / AL AL AIL AL aFck �,00, i , 4 REQUIRED i / 3.0, \ /' 4 0' PROPOSED WASTEWATER ACTIVE AND REPAIR SYST\ c 9 RFFN �� 50• RURAFLO PEAT BIOFILTER SYSTEM — TYPE A PQ poRCN SYSTEM WTS 98-1—R3 ' //INNOVATIVE TREATMENTSTANDA D1 2' SECOND FLOOR CAN/. DESIGN FLOW = 480 GPD (4 BEDROOMS) 4 PODS REQUIRED (1 PER BEDROOM) LOADING RATE = 1.0 GPD/ SQ. FT. \\\ PROPOSED i GRAVEL BED AREA = Q/LTAR = 480 SQ. FT. %o i; FILLED ELEVATIONS USE 25% BED REDUCTION <� 8' SIDE SETBACK REQUIRED GRAVEL BED AREA — 360 SQ. FT. / i;99j6•;' i REQUIRED GRAVEL BED PROVIDED = 360 SQ. FT. 4 HVAC STAND '17 3' 10' � 5. • SUBJECT PROPERTY \ LOT 66 PAMLICO POINT \ \ P.C. A SL. 6982 LOT 56 PAMLICO POINT 1 / 1 = AL `' AL a RFC•,lalk AL AL EXISI ING TROD P.C. A SL. 6982 / IRON AL / EXISTING ACOE WETLAND LINE / LOT 57 / PAMLICO POINT / P.C. A SL. 69B2 2 / LOT 58 / / PAMLICO POINT / P.C. A SL. 69B2 / / / / / / / / / / / j/ PAMLICO POINT P.C. A SL. 69132 / / •-1�'.—.—.—.—.—.—.—.—.— � / DDITIONAL FILL REQUIRED i AREA = 400 sq. ft. '�` / LOT 68 / %� / PAMLICO POINT / P.C. A SL. 6962 ' A AILEXIS IING RONROD — , / SUBJECT AL / / PROPERTY PAMLICO POINT LL P.C. A SL. 6962 \ AL AL AL AL AIL AL \ \ AL ALLOT AL / \ AL OPOINT AL AL PAMLICO / P.C. A SL. 69B2 / \ \ // / A \ AL LOT \ PAML COOPOINT AL / P.C. A SL. 6962 / GRAPHIC SCALD\ / 20 / 10 20 40 \ 80 0 / / / ( IN FEET) / \ 1 inch = 20 ft. / U) J IL Z W 5,:00 E O . LU 0') A � r- L� N o, C N 0cn (o N S c 'rn 00 z w0C14 Lr)X Z Z X ( N O �_ °° N En � Ln O = cV C vo ) Z (z; _J la_i W O o W W C� Qz E Z _J J J Y Q w W Z Q LU _U m z F— 0_ Z of U c' 00 U) LU LLJ I-__ Q 0 z a C) q o � CQ � w � w Q' O w Q ^:co H 0 E-, U v 1 O x Z n a Q OL DATE: SCALE: 01-31-21 1 "=20 DRAWN: APPROVED: MWR MWR SHEET: 1 3 of CAD FILE: point— lot 53 rROJhines—pamlico ECT NO: 30416 SITE Copyright (C) 2009 MyTopo 075° 59' 00.00" W 075° 59' 00.00" W 075° 58' 00.00" W 075° 58' 00.00" W 075° 57' 00.00" W 075° 57' 00.00" W035° 08' 00.00" N035° 08' 00.00" N035° 07' 00.00" N035° 07' 00.00" N035° 06' 00.00" N035° 06' 00.00" N035° 05' 00.00" N035° 05' 00.00" NSCALE 1:24000 0 1 MILE 0 1000 YARDS 0 1 KILOMETER Declination MN 10.43° W  MN Location: 035° 06' 28.17" N 075° 58' 11.31" WName: OCRACOKE Date: 02/09/21 Scale: 1 inch = 2,000 ft. Copyright (C) 2009 MyTopo Datum: NAD27 Soil Map—Hyde County, North Carolina Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 2/9/2021 Page 1 of 338853603885390388542038854503885480388551038855403885360388539038854203885450388548038855103885540411520411550411580411610411640411670411700411730411760411790 411520 411550 411580 411610 411640 411670 411700 411730 411760 411790 35° 6' 31'' N 75° 58' 15'' W35° 6' 31'' N75° 58' 4'' W35° 6' 25'' N 75° 58' 15'' W35° 6' 25'' N 75° 58' 4'' WN Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 18N WGS84 0 50 100 200 300 Feet 0 20 40 80 120 Meters Map Scale: 1:1,360 if printed on A landscape (11" x 8.5") sheet. Soil Map may not be valid at this scale. MAP LEGEND MAP INFORMATION Area of Interest (AOI) Area of Interest (AOI) Soils Soil Map Unit Polygons Soil Map Unit Lines Soil Map Unit Points Special Point Features Blowout Borrow Pit Clay Spot Closed Depression Gravel Pit Gravelly Spot Landfill Lava Flow Marsh or swamp Mine or Quarry Miscellaneous Water Perennial Water Rock Outcrop Saline Spot Sandy Spot Severely Eroded Spot Sinkhole Slide or Slip Sodic Spot Spoil Area Stony Spot Very Stony Spot Wet Spot Other Special Line Features Water Features Streams and Canals Transportation Rails Interstate Highways US Routes Major Roads Local Roads Background Aerial Photography The soil surveys that comprise your AOI were mapped at 1:24,000. Warning: Soil Map may not be valid at this scale. Enlargement of maps beyond the scale of mapping can cause misunderstanding of the detail of mapping and accuracy of soil line placement. The maps do not show the small areas of contrasting soils that could have been shown at a more detailed scale. Please rely on the bar scale on each map sheet for map measurements. Source of Map: Natural Resources Conservation Service Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) Maps from the Web Soil Survey are based on the Web Mercator projection, which preserves direction and shape but distorts distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more accurate calculations of distance or area are required. This product is generated from the USDA-NRCS certified data as of the version date(s) listed below. Soil Survey Area: Hyde County, North Carolina Survey Area Data: Version 18, Jun 4, 2020 Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Dec 31, 2009—Oct 30, 2017 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. Soil Map—Hyde County, North Carolina Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 2/9/2021 Page 2 of 3 Map Unit Legend Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI CeA Carteret sand, 0 to 3 percent slopes, occasionally flooded 4.8 92.7% DuA Duckston sand, 0 to 2 percent slopes, rarely flooded 0.4 7.3% Totals for Area of Interest 5.2 100.0% Soil Map—Hyde County, North Carolina Natural Resources Conservation Service Web Soil Survey National Cooperative Soil Survey 2/9/2021 Page 3 of 3