Loading...
HomeMy WebLinkAboutNC0021849_NOV-2021-PC-0177 NOI_20210311ROY COOPER Governor DIONNE DELI-GATTI Secretary S. DANFEL SMITH bfrecrar Certified Mail # 7020 1810 0001 5981 1228 Return Receipt Requested Pamela Hurdle, Manager Town Town of Hertford 324 W Grubb St Hertford, NC 27944 NORTH CAROLINA Environmental Quality March 11, 2021 SUBJECT: NOTICE OF VIOLATION & INTENT TO ASSESS CIVIL PENALTY Tracking Number: NOV-2021-PC-0177 Permit No. NC0021849 Hertford WWTP Perquimans County Dear Mrs. Hurdle: The North Carolina Division of Water Resources conducted an inspection of the Hertford WWTP on February 24, 2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0021849. A summary of the findings and comments noted during the inspection are provided in the enclosed copy of the inspection report. The Compliance Evaluation inspection was conducted by Division of Water Resources staff from the Washington Regional Office. The following violation(s) were noted during the inspection: Inspection Area Description of Violation Permit An unauthorized bypass of unknown quantity was found nearby the aerobic digestors during the inspection. A sludge strip was observed that was roughly 100ft in length and 10ft across at its widest point. The ORC stated that the unauthorized bypass took place on 11/19/2020 during the last sludge haul. The bypass was never reported to WARO and was required to be reported to WARO within 24 hours as required by NPDES permit #NC0021849. This is a violation of the following permit conditions: Section B Condition 2, Section E Condition 6 and Section E condition 9. North Caro!i no 17epartne nt of Environmental Quality I Division of Water Resou rues Washington Regional Office 1943 Washington Square Mall I Washington, North Carolina 27339 252-946-6431 Inspection Area Description of Violation Filtration (High -Rate Tertiary) During the inspection on 02/24/2020 one of the two automatic disk filters described in NPDES permit #NC0021849 was not operational and was also down during the previous inspection on 08/19/2020. The automatic disk filter that was operational during the inspection was being heavily bypassed. This is a violation of permit conditions: Section C Condition 2, Section C Condition 4.C, Section E Condition 6 and Section E Condition 9. A Notice of Violation/Intent to Issue Civil Penalty is being issued for the noted violation of North Carolina General Statute (G.S.) 143-215.1 and the facility's NPDES WW Permit. Pursuant to G.S. 143-215.6A, a civil penalty of not more than twenty-five thousand dollars ($25,000.00) may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. If you wish to provide additional information regarding the noted violation, request technical assistance, or discuss overall compliance please respond in writing within ten (10) business days after receipt of this Notice. A review of your response will be considered along with any additional information provided. You will then be notified of any civil penalties that may be assessed regarding the violations. If no response is received in this Office within the 10-day period, a civil penalty assessment may be prepared. Remedial actions should have already been taken to correct this problem and prevent further occurrences in the future. The Division of Water Resources may pursue enforcement action for this and any additional violations of State law. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent. Reminder: Pursuant to Permit Condition: Section E Condition 6, the Permittee is required to verbally notify the Regional Office as soon as possible, not to exceed 24 hours, from first knowledge of non-compliance at the facility including limit violations, bypasses of, or failure of a treatment unit. A written report may be required within 5 days if directed by Division staff. Prior notice should be given for anticipated or potential problems due to planned maintenance activities, taking units off-line, etc. If you should have any questions, please do not hesitate to contact Paul Mays with the Water Quality Regional Operations Section in the Washington Regional Office at 252-948-3940 or via email at paul.mays@ncdenr.gov. Sincerely, Rottil Teoskva Robert Tankard, Assistant Regional Supervisor Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ ATTACHMENTS Cc: Laserfiche DEQ North Ca ro: na Departure nt of Environmental Qusl ay I Division of Water Resources Washington Regona4ff.ce 1 943 Washington Square Mal; l Washington, North Carolina 27339 252-943 1