SUBJECT: Compliance Evaluation Inspection Report for the June 1, 2011 inspection
DAK Americas LLC — Fayetteville
NC0003719
Cumberland County
Dear Mr. Allbright,
Enclosed you will find a copy of the Compliance Evaluation Inspection (CEI) report for the routine
annual inspection that I performed on June 1, 2011 at the DAK Wastewater Treatment Plant. As part of
the inspection, a tour of the Wastewater Treatment Plant was conducted. All observations are in Section
D. Summary of Findings/Comments of this inspection report. On the day of my inspection, the
wastewater treatment plant appeared to be in compliance with the NPDES permit. I appreciate the time
and professional courtesy that you extended during the inspection. No additional response is necessary
from your office to the DWQ-Fayetteville Regional Office concerning this CEI report. Please contact me
at (910) 433-3312 if you have any questions or comments.
Sincerely,
Dale Lopez
Environmental Specia ist
Enclosures: EPA Water Compliance Inspection Report
BIMS Compliance Evaluation Check List
Check List for Field Parameters
cc: Anthony Hudson, DAK Safety, Health, and Environment Manager
FRO files (Mark Brantley)
225 Green St, Suite 714, Fayetteville, NC 28301-5043
Phone: 910-433-3300 \ FAX; 910-486-0707 ( Customer Service: 1-877-623-6748
Internet: www.ncwaterquality.org
An Equal Opportunity \ AYrmative Action Employer
One
North Carolina
Naturally
United States Environmental Protection Agency
EWashington, D.C. 20460
PA
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 I NI 2 15I 31 NC0003719 ' 111 121 11/06/01 117
Type Inspector Fac Type
181 CI 19I sI 20I II
Remarks
21111III1I1II1I1IIII11II1I11IIIIIIIIIII1I11I111II66
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA
67I 2.0 169 70I 41 711 I 72111
-----------Reserved------
731
I 174 79 I I 1 I 1 1 180
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Cedar Creek Site
3468 Cedar Creek Rd
Fayetteville NC 28301
Entry Time/Date
10:00 AM 11/06/01
Permit Effective Date
09/10/01
Exit Time/Date
03:00 PM 11/06/01
Permit Expiration Date
11/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Donald Ray Allbright/ORC/910-433-8227/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Anthony Hudson,PO Box 1690 Fayetteville NC 28302//910-433-8338/ No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenance Records/Reports
Self -Monitoring Program Sludge Handling Disposal • Facility Site Review Effluent/Receiving Waters
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Sign (s) of Inspector(s Agency/Office/Phone and Fax Numbers
Dale Lopez-(_t FRO WQ//910-433-3300 Ext.712/
Date
/9/..? / i
Signature of Management Q Revie er n Agency/Office/Phone and Fax Numbers Date
G /3// 1
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
Page # 1
3I
NPDES
NC0003719
111 12I
yr/mo/day
11/06/01
Inspection Type
117 18I C
(cont.) 1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
This facility was found to be in compliance with NPDES Permit NC0003719. All units were in service. The
secondary clarifier generally maintained a sludge blanket level of 2 to 4 feet. On the day of this inspection,
the sludge blanket level was 2 feet. The 002 DMR for January 2011 was checked for errors in transposing
and calculation. There were no errors found. DAK uses TBL as their commercial laboratory, and TBL
contracts out the aquatic toxicity to Meritech. The metals were sent from TBL to Element ONE for
analyses.
Page # 2
Permit: NC0003719 Owner - Facility: Cedar Creek Site
Inspection Date: 06/01/2011 Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Is the plant generally clean with acceptable housekeeping? • n n n
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge ■ n n n
Judge, and other that are applicable?
Comment: Process control parameters were MLSS, MCRT, Settleable Solids, pH, DO,
Sludge Judge, and DOUR.
Permit Yes No NA NE
(If the present permit expires in 6 months or less). Has the permittee submitted a new application? • n n n
Is the facility as described in the permit? ■ n n n
# Are there any special conditions for the permit? ■ n n n
Is access to the plant site restricted to the general public? ■ n n
Is the inspector granted access to all areas for inspection? •000
Comment:
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? ■ n n n
Is all required information readily available, complete and current? ■ n n n
Are all records maintained for 3 years (lab. reg. required 5 years)? R n n n
Are analytical results consistent with data reported on DMRs? ■ n n n
Is the chain -of -custody complete? ■ n n n
Dates, times and location of sampling ■
Name of individual performing the sampling ,
Results of analysis and calibration
Dates of analysis ■
Name of person performing analyses ■
Transported COCs
Are DMRs complete: do they include all permit parameters'? ■ n n n
Has the facility submitted its annual compliance report to users and DWQ? ■ n n n
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift? n n ■ n
Is the ORC visitation log available and current? ■ n n n
Is the ORC certified at grade equal to or higher than the facility classification? ■ n n n
Is the backup operator certified at one grade less or greater than the facility classification? ■ n n n
Page # 3
Permit: NC0003719 Owner - Facility: Cedar Creek Site
Inspection Date: 06/01/2011 Inspection Type: Compliance Evaluation
Record Keeping
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Comment: DAK is permitted for a flow of 0.5 MGD. They operate 24/7 with certified
operators.
Effluent Pipe
Is right of way to the outfall properly maintained?
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes.are required) are they operating properly?
Comment: The effluent was a pipe source under water into the Cape Fear River.
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment:
Grease Removal
# Is automatic grease removal present?
Is grease removal operating properly?
Comment: This unit has two oil skimmers that are located at the pH pit.
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Yes No NA NE
• 000
■ ❑❑❑
Yes No NA NE
■ nnn
■ ❑❑❑
❑❑■❑
Yes No NA NE
■ nnn
■ nnn
■ ❑❑❑
❑n❑■
Yes No NA NE
■ ❑❑❑
■ ❑❑❑
Yes No NA NE
■ ❑❑❑
■ ❑❑❑
1nnn
• 000
annn
■ ❑❑❑
■ ❑❑❑
■ nnn
■ n❑n
■ ❑❑❑
Page # 4
Permit: NC0003719 Owner - Facility: Cedar Creek Site
Inspection Date: 06/01/2011 Inspection Type: Compliance Evaluation
Secondary Clarifier Yes No NA NE
Is the sludge blanket level acceptable? (Approximately % of the sidewall depth) ■ n n n
Comment:
Aeration Basins Yes No NA NE
Mode of operation Ext. Air
Type of aeration system Surface
Is the basin free of dead spots? ■ n n n
Are surface aerators and mixers operational? ■ n n
Are the diffusers operational? ■ n n n
Is the foam the proper color for the treatment process? ■ n n n
Does the foam cover less than 25% of the basin's surface? ■ n n n
Is the DO level acceptable? ■ n n n
Is the DO level acceptable?(1.0 to 3.0 mg/I) ■ n n n
Comment: Aeration Basin AB-1 was being used. The other aeration basin (AB-2)
was primarily used as an aerobic digester.
Laboratory Yes No NA NE
Are field parameters performed by certified personnel or laboratory? ■ n n n
Are all other parameters(excluding field parameters) performed by a certified lab? ■ n n
# Is the facility using a contract lab? ■ n n n
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? ❑ ❑ ■ n
Incubator (BOD) set to 20.0 degrees Celsius +/-1.0 degrees? nnion
Comment:
Effluent Sampling Yes No NA NE
Is composite sampling flow proportional? ■ n n n
Is sample collected below all treatment units? Er -inn
Is proper volume collected? ■ n n n
Is the tubing clean? ■ n n n
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? ■ n n n
Is the facility sampling performed as required by the permit (frequency, sampling type representative)? ■ n n n
Comment:
Page # 5
Permit: NC0003719 Owner - Facility: Cedar Creek Site
Inspection Date: 06/01/2011 Inspection Type: Compliance Evaluation
Aerobic Digester Yes No NA NE
Is the capacity adequate? ■ ❑ ❑ ❑
Is the mixing adequate? • ❑ ❑ ❑
Is the site free of excessive foaming in the tank? ■ ❑ ❑ ❑
# Is the odor acceptable? ■ ❑ ❑ ❑
# Is tankage available for properly waste sludge? ■ ❑ ❑ ❑
Comment:
Drying Beds Yes No NA NE
Is there adequate drying bed space? ■ ❑ ❑ ❑
Is the sludge distribution:on drying beds appropriate? ■ ❑ ❑ ❑
Are the drying beds free of vegetation? ■ ❑ ❑ ❑
# Is the site free of dry sludge remaining in beds? ■ ❑ ❑ ❑
Is the site free of stockpiled sludge? ■ ❑ ❑ ❑
Is the filtrate from sludge drying beds returned to the front of the plant? ■ ❑ ❑ ❑
# Is the sludge disposed of through county landfill? n ❑ • ❑
# Is the sludge land applied? ■ ❑ ❑ ❑
(Vacuum filters) Is polymer mixing adequate? ■ ❑ ❑ ❑
Comment: McGill handles the hauling and composting of the dried sludge from the
sludge storage area and from the,aerobic digester.
Chemical Feed Yes No NA NE
Is containment adequate? ■ ❑ ❑ ❑
Is storage adequate? ' ■ ❑ ❑
Are backup pumps available? ai.nnn
Is the site free of excessive leaking? ■ ❑ ❑ ❑
Comment:
Standby Power Yes No NA NE
Is automatically activated standby power available? ❑ ❑ • ❑
Is the generator tested by interrupting primary power source? ❑ ❑ ■ ❑
Is the generator tested under load? ❑ ❑ ■ ❑
Was generator tested & operational during the inspection? ❑ ❑ ■ ❑
Do the generator(s) have adequate capacity to operate the entire wastewater site? ❑ ❑ ■ ❑
Page # 6
Permit: NC0003719 Owner - Facility: Cedar Creek Site
Inspection Date: 06/01/2011 Inspection Type: Compliance Evaluation
Standby Power Yes No NA NE
Is there an emergency agreement with a fuel vendor for extended run on back-up power? n 0 • 0
Is the generator fuel level monitored? ❑ n ■ n
Comment: There are dual electrical feed lines from Progress Energy. There are no
generators for the VVVVTP.
Page # 7
Regional Field Inspectors Check List for Field Parameters
Name of site to be Inspected: DAK
Date June 1, 2
Field certification # (if applicable): 5378 Inspector: Dale Lopez
NPDES #: NC0003719
Region: FRO
I. Circle the parameter or parameters performed at this site.
Residual Chlorine
, Settleable Solids,
II. Instrumentation:
pH
DO
, Conductivity,
Temperature
A. Does the facility have the equipment necessary to analyze field parameters as circled above?
1. A pH meter
HACH Senslon 2
2. A Residual Chlorine meter
3. DO meter
4. A Cone for settleable solids
HACH Colorimeter
fYS 155
Yes
No
Yes No
NYes
No
Yes No
5. A thermometer or meter that measures temperature. fres No
frSI 55
6. Conductivity meter
III. Calibration/Analysis:
1. Is the pH meter calibrated with 3 buffers and
checked with a fourth buffer each day of use?
2. For Total Residual Chlorine, is a check standard
analyzed each day of use?
3. Is the air calibration of the DO meter performed
each day of use?
Yes No
Yes
Yes
Yes
4. For Settleable Solids, is 1 liter of sample
settled for 1 hour? Yes
5. Is the temperature measuring device calibrated
annually against a certified thermometer?
6. For Conductivity, is a calibration standard
analyzed each. day of use?
NYes
Yes
No
No
No
No
No
No
NE
NE
NE
IV. Documentation:
1. Is the date and time that the sample was collected documented?
2. Is the sample site documented?
3. Is the sample collector documented?
4. Is the analysis date and time documented?
5. Did the analyst sign the documentation?
6. Is record of calibration documented?
7. For Settleable Solids, is sample volume and
1 hour time settling time documented?
8. For Temperature, is the annual calibration of
the measuring device documented?
Comments:
Yes
hYes
fres
Yes
fres
fres
Yes
lYes
No
No
No
No
No
No
No
No
pH 4 Buffer expired on 11/2012
pH 7 Buffer expired on 12/2012
pH 10 Buffer expired on 6/2012
Second pH 7 Buffer check, expired on 2/2012
Please submit a copy of this completed form to the Laboratory Certification Program.
DWQ Lab Certification
Chemistry Lab
Courier # 52-01-01
FIELD INSPECTOR CHECKLIST REV. 04/23/2002