May 19, 2004
Stanley Carter, Service Complex Site Manager
DAK Resins LLC
PO Box 1690
Fayetteville NC 28312
SUBJECT: May 6, 2004 Compliance Evaluation Inspection
DAK Resins LLC
DAK Resins LLC - Fayetteville
Permit No: NC0003719
Cumberland County
Dear Mr. Carter:
Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted
on May 6, 2004. The Compliance Evaluation Inspection was conducted by Belinda S. Henson and Mike
Lawyer of the Fayetteville Regional Office. The cooperation of Mr. Donald Allbright, ORC was greatly
appreciated. The facility was found to be in Compliance with permit NC0003719.
Please refer to the enclosed inspection report for additional observations and comments. If you or your staff
have any questions, please call me at (910)486-1541.
Sincerely,
Belinda &Henson
Environmental Chemist
cc: Donald Ray Allbright, ORC
Central Files
Fayetteville Files
NCDENR
is
NCDENR Division of Water Quality
Customer Service 1 877 623-7748
225 Green Street -Suite 714 . Fayetteville, NC 28301-50431 (910)486-1541 Telephone
(910)486-0707 Fax
United States Environmental Protection Agency
EPA ^ Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 1 N 1 2 U 31 NC0003719 111 121 04/05/06 117
Type Inspector Fac Type
18 LI 19 I S I 20 L_I
Remarks
21IIIIIIIIIIII11111111111111IIIIIIIIIIIIIillllll166
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA --- Reserved
671 1 69 701 J 71 1 NJ 721 j 11 174 751 1 1 1 1 1 1 1 80
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
DAK Resins LLC - Fayetteville
3468 Cedar Creek Road
Fayetteville NC 28302
Entry Time/Date
09:30 AM 04/05/06
Permit Effective Date
03/04/01
Exit Time/Date
12:30 PM 04/05/06
Permit Expiration Date
06/10/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
Donald Ray Allbright/ORC/910-433-4259/
///
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Craig Leite,PO Box 1690 Fayetteville NC 28312/Site Contacted•
No
Manager/910-433-8254/
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit ■ Flow Measurement 1 Operations & Maintenance
• Records/Reports
Effluent/Receiving Waters
Self -Monitoring Program Sludge Handling Disposal 1 Facility Site Review
• Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
Belinda S Henson `•Z;-;1,0 G7�1.. . y '%10tri"C) FRO WQ//91048615411726/910-486-0707 8_ IS -0 /^L
Signature of Manag ent vie r Agency/Office/Phone and Fax Numbers Date
Paul E Rawls 91048615411726/910-486-0707
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
31
NPDES yr/mo/day
NC0003719 111 12 04/05/06
117
Inspection Type
18 ,U
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
The facility accepts wastewater from the following industries located on the complex site: Dupont and DAK.
Dupont manufactures film and DAK manufactures plastic chips for drink bottles and food products. The
influent flow is generated from these two facilities.
Aeration Basin #1 is presently used as a digester. It is fed into the plant slowly until a pumping system
can be implemented to pump directly into the digester.
Permit:. NC0003719 Owner - Facility: DAK Resins LLC - DAK Resins LLC - Fayetteville
Inspection Date: 05/06/04 Inspection Type: Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new application?
Is the facility as described in the permit?
Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment:
Operations & Maintenance
Does the plant have general safety structures in place such as rails around or covers over tanks, pits, or wells?
Is the plant generally clean with acceptable housekeeping?
Comment:
Pump Station - influent
Is the pump wet well free of bypass lines or structures?
Is the general housekeeping acceptable?
Is the wet well free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable? .
Is SCADA telemetry available and operational?
Is audible and visual alarm available and operational?
Comment:
Fnuali7ation Basins
Is aeration adequate?
Is the basin free of bypass lines or structures to the natural environment?
Is the general housekeeping acceptable?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
Is basin size/volume adequate?
Yes No NA NF
O ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ ❑❑❑'
• ❑ ❑ ❑
Yes No NA NF
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NF
❑ ❑ 1 ❑
❑ ❑•❑
❑ ❑•❑
❑ ❑ • ❑
❑ ❑• ❑.
O ❑ ■ ❑
❑ O ■ O
❑ ❑•❑
Yes No NA NF
❑ O ■ ❑
❑ ❑ ❑•
■ ❑ ❑ 0
.0 ❑ ❑•-
❑ ❑•❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
❑ ❑ ■ ❑
• ❑ ❑ ❑
Comment:Wastewater is pumped into the two (2) EQ basins parallel and then they flow by gravity into the headworks of
the WWTP.
Secondary Clarifier
Yes No NA NF
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the sludge blanket level acceptable?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
■ ❑❑❑
I11000
11000
■ ❑❑O
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
■ O ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
▪ ❑ ❑ ❑
Permit: NC0003719 Owner - Facility: DAK Resins LLC - DAK Resins LLC - Fayetteville
Inspection Date: 05/06/04 Inspection Type: Compliance Evaluation
Secondary Clarifier
Is the surface free of bulking ?
Comment:There was three (3) feet of sludge in the clarifier with a tank depth of 14 (fourteen) feet.
Pumps-RAS-DNA$
Are pumps in place?
Are pumps operational?
Are there adequate spare parts and supplies on site?
Comment:
Aeration Basins
Mode of operation
Type of aeration system
Is the basin free of dead spots?
Are surface aerators and mixers operational?
Are the diffusers operational?
Is the foam the proper color for the treatment process?
Does the foam cover less than 25% of the basin' s surface?
Is the DO level acceptable?
Are settleometer results acceptable?
Comment:
Disinfection
Type of system ?
Are cylinders secured adequately?
Are cylinders protected from direct sunlight?
Is there adequate reserve supply of disinfectant?
Is ventilation equipment operational?
Is ventilation equipment properly located?
Is SCBA equipment available on site?
Is SCBA equipment operational?
Is staff trained is operating SCBA equipment?
Is staff trained in emergency procedures?
Is an evacuation plan in place?
Are tablet chlorinators operational?
Are the tablets the proper size and type?
Number of tubes in use?
(Sodium Hypochlorite) Is pump feed system operational?
Is bulk storage tank -containment area adequate? (free of leaks/open drains)
Is the level of chlorine residual acceptable?
Is there adequate detention time
Is the contact chamber free of growth, or sludge buildup?
Comment:
Pumn Station - Effluent
Is the pump wet well free of bypass lines or structures?
Is the general housekeeping acceptable?
Is the wet well free of excessive grease?
Are all pumps present?
Yes No NA NF
■ ❑❑❑
Yes No NA NF
■ ❑❑o
■ O O ❑
■ ❑❑❑
Yes No NA NF
▪ ❑ ❑ ❑
■ ❑ ❑ ❑
1 ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑❑❑
1 ❑ ❑ ❑
pool"
Yes No NA NF
❑ ❑ ■ ❑
❑ 0 ■ ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ ■ ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ ■ ❑
❑ ❑ • ❑
❑ ❑■o
❑ ❑ • ❑
❑ ❑ 1 ❑
❑ ❑ • ❑
❑ ❑■o
❑ ❑ • ❑
Yes Nn NA NF
❑ ❑ • ❑
❑ O ■ O
❑ ❑ • ❑
❑ 0.0
Permit: NC0003719 Owner - Facility: DAK Resins LLC - DAK Resins LLC - Fayetteville
Inspection Date: 05/06/04 Inspection Type: Compliance Evaluation
punin Station - Effluent Yes Nn NA NF
Are all pumps operable? ❑ ❑ R ❑
Are float controls operable? ❑ ❑ ❑
Is SCADA telemetry available and operational? 0 0 • 0
Is audible and visual alarm available and operational? 0 0 • 0
Comment:Effluent is gravity fed to the Cape Fear River.
Standby Power
Yes No NA NF
Is automatically activated standby power available? 0 0 • 0
Is generator tested weekly by interrupting primary power source? ❑ ❑ NO
Is generator tested under load at least quarterly? 0 0 • 0
Was generator tested & operational during the inspection? 00.0
Do the generator(s) have adequate capacity to operate the entire wastewater site? 0 0 • 0
Does generator have adequate fuel? 0 0 • 0
Is there an emergency agreement with a fuel vendor for extended run on back-up power? ❑ ❑ ❑
Comment:Facility has a power feed into two different stations into the Wastewater Treatment Plant.
I aboratory Yes No NA NF
Are field parameters performed by certified personnel or laboratory? 1 ❑ ❑ ❑
Are all other parameters(excluding field parameters) performed by a certified lab? •❑ ❑ 0
Is the facility using a contract lab? .• 0 0 0
Are analytical results consistent with data reported on DMRs? 'N ❑ ❑ ❑
Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)? •❑ ❑ ❑
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees? 00E10
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees? ❑ ❑ ❑
Comment:All field parameters are analyzed by the Cape Fear facility for this site. The laboratory certification number is
139.
Flow Measurement - Influent Yes No NA NF
Is flow meter used for reporting? 00.0
Is flow meter calibrated annually? ❑ ❑ E ❑
Is flow meter operating properly? ❑ ❑ M ❑
(If units are separated) Does the chart recorder match the flow meter? 00.0
Comment:
Flow Measurement - Effluent Yes No NA NF
Is flow meter used for reporting? •❑ ❑ ❑
Is flow meter calibrated annually? 1 ❑ ❑ ❑
Is flow meter operating properly? •❑ ❑ ❑
(If units are separated) Does the chart recorder match the flow meter? ❑ ❑ ❑•
Comment:Effluent flow meter was calibrated February 5, 2004 by facility staff. The % error was +/- 5% as per the
calibration report.
Re ,ord Keepinct Yes Nn NA NF
Are records kept and maintained as required by the permit? •❑ ❑ ❑
Is all required information readily available, complete and current? 1 ❑ ❑ ❑
Are all records maintained for 3 years (lab. reg. required 5 years)? 1 ❑ ❑ ❑
Are analytical results consistent with data reported on DMRs? • 0 0 0
Are sampling and analysis data adequate and include: •❑ ❑ ❑
Dates, times and location of sampling •
Name of individual performing the sampling •
Permit: NC0003719 Owner - Facility: DAK Resins LLC - DAK Resins LLC - Fayetteville
Inspection Date: 05/06/04 Inspection Type: Compliance Evaluation
Record Keening
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Plant records are adequate, available and include
O&M Manual
As built Engineering drawings
Schedules and dates of equipment maintenance and repairs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification?
Is a copy of the current NPDES permit available on site?
Is the facility description verified as contained in the NPDES permit?
Does the facility analyze process control parameters, for example: MLSS, MCRT, Settleable Solids, DO, Sludge
Judge, pH, and others that are applicable?
Facility has copy of previous year's Annual Report on file for review?
Comment:Laboratory records were reviewed for the months July, August, and September 2003 and compared to
Discharge Monitoring Reports (DMRs). All records reviewed appeared to be accurate.
Infit ent Samnlinq
Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)?
Is sampling performed according to the permit?
Comment:
Ffflr lent Sampling,
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
Is proper temperature set for sample storage (kept at 1.0 to 4.4 degrees Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type representative)?
Comment:
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
Is the odor acceptable?
Comment:
Drying Beds
Is there adequate drying bed space?
Yes No NA NF
•
•
•
• ❑ ❑ ❑
•
•
•
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ ■ ❑
■ ❑❑❑
■ ❑❑❑
1000
1000
1000
1000.
O ❑ ■ 0
Yes No NA NF
O 0110
❑ ❑ • ❑
❑ ❑■❑
❑ ❑ • ❑
❑ ❑ • ❑
O 0110
Yes No NA NF
1000
1000
11000
1000
1000
■ ❑ ❑ ❑
Yes No NA NF
1000
1000
1000
1000
Yes No NA NF
:1000
Permit: NC0003719 Owner - Facility: DAK Resins LLC - DAK Resins LLC - Fayetteville
Inspection Date: 05/06/04 Inspection Type: Compliance Evaluation
Drying Reds
Is the sludge distribution on drying beds appropriate?
Are the drying beds free of vegetation?
Is the site free of dry sludge remaining in beds?
Is the site free of stockpiled sludge?
Is the filtrate from sludge drying beds returned to the front of the plant?
Is the sludge disposed of through county landfill?
Is the sludge land applied?
(Vacuum filters) Is polymer mixing adequate?
Comment:
Fffluent Pipe
Is right of way to the outfall properly maintained?
Are receiving water free of solids and floatable wastewater materials?
Are the receiving waters free of solids / debris?
Are the receiving waters free of foam other than a trace?
Are the receiving waters free of sludge worms?
If effluent (diffuser pipes are required) are they operating properly?