Della Moore
drmoore2@ncdot.gov
NCDOT
E. Steeple Chase Road Bridge Replacement
Guilford
City
Greensboro
State / Province / Region
NC
Postal / Zip Code
27415
Country
USA
Street Address
P.O. Box 14996
Address Line 2
Yes No
401 Water Quality Certification -
Regular
401 Water Quality Certification -
Express
Individual Permit Modification
Shoreline Stabilization
Yes No
17BP.7.R.128/B-4956/SF-400025
Dave Wanucha
Please give a couple of dates you are available for a meeting.
Ple ase attach the docume ntation you would like to hav e the me e ting about.
Signature *
Submittal Date
The North Carolina Department of Transportation (NCDOT) has
proposed to replace Guilford County Bridge No. 25 on East Steeple
Chase Road (SR 1105) over Polecat Creek. The existing structure
has undergone numerous repairs and inspections at which the final
recommendation is to replace the structure in its entirety due to
critical scouring. The existing structure consists of a 71' steel deck on
I-Beams with vertical timber abutments. There are two existing spans
(1@35'5" and 1@35'9") with timber caps and piles for interior
bents/abutments. The proposed structure shall consist of a 3-span
structure (1@45', 1@50' and 1@45') cored slab with 4' caps. The
proposed structure has been designed to minimize as little
environmental impacts to wetlands, surface waters and existing
habitat as possible with 2:1 roadway fill slopes. Supporting
documentation has been attached below.
1/26/2021
1/28/2021
17BP.7.R.128_Guilford Bridge # 25 Plans.pdf 1.44MB
Steeplechase Archeological No Survey.pdf 1016.11KB
Steeplechase Archictectural No Survey.pdf 3.59MB
40 0025 2019 SF-400025 POLECAT CREEK
SR 1105 Hydro Dwg.pdf
15.12MB
Vicinity and Location Maps-Guilford Bridge
#25.docx.pdf
1.13MB
pdf only
By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section
401 Certification Rule the following statements:
· This form completes the requirement of the Pre-Filing Meeting Request in the Clean Water Act Section 401 Certification
Rule.
· I understand by signing this form that I cannot submit my application until 30 calendar days after this pre-filing
meeting request.
· I also understand that DWR is not required to respond or grant the meeting request.
Your project’s thirty-day clock started upon receipt of this application. You will receive notification regarding meeting location
and time if a meeting is necessary. You will receive notification when the thirty-day clock has expired, and you can submit an
application.
1/19/2021