Loading...
HomeMy WebLinkAbout20201479 Ver 1_More Info Received_20210305Strickland, Bev From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Friday, March 5, 2021 1:05 PM To: Homewood, Sue Cc: Haywood, Casey M CIV (USA); josh; Hopper, Christopher D CIV (USA); Amber Farrelly; 'Russell Briggs'; Kirby LaForce Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Attachments: RileysMeadow-CD-20210302-SEWE RIM PACT- revised. pdf, RileysMeadow- CD-20210302-SEWERPROFILE-revised.pdf Follow Up Flag: Follow up Flag Status: Flagged CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Sue and Chris, Attached are revised permit drawings for the sewer crossing that includes the small wetland that was claimed during our site review. That wetland will incur 0.038ac (556 sf) of temporary impact from the sewer crossing. Below is a description of the crossing construction as provided by the engineer. I hope this information is sufficient for ACOE and DWR to resume the review of the application. Let me know if you have any questions or need further information. The 10" aerial sanitary sewer will be placed on piers of zone 1 and zone 2 of the riparian buffer. The construction of the aerial sewer will consist of clearing the 50' wide temporary easement, of which 30' is a permanent easement centered on the sewer. Next, the footings for the 3 piers in the buffer zone will be excavated and the footings poured. The footings are 3' in length, 4' in width and 1' thick, so the amount of excavation for each footing is minimal. The piers will be formed and poured. Each pier has a dimension perpendicular to the stream of 1 foot. The dimension parallel to the stream is 2 feet. Lastly, the mechanical joint 10" diameter ductile iron pipe will be placed on the piers. Josh, we are preparing the buffer authorization request and should have that to you next week. Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 ieff.harbour(o)terracon.com I terracon.com From: Homewood, Sue <sue.homewood@ncdenr.gov> Sent: Sunday, February 28, 2021 11:43 AM To: Harbour, Jeff W <Jeff.Harbour@terracon.com> Cc: Haywood, Casey M CIV (USA) <Casey.M.Haywood@usace.army.mil>; josh <josh@awck.com>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.miI> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Hi Jeff, At the site visit we also discussed that you would provide some construction details regarding the sewer crossing. I will place the application on hold until we receive that and until you confirm whether there will be any additional impacts to the small wetland adjacent to the crossing location. I'm attaching a stream determination letter and copying Josh Johnson for local government documenting the buffer determination I made on Stream SC. Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue. Homewood@ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 x.. x#.: r, x x.tv. t.. x :+ ,; r 1 .'? x•.., t.. Y. .i ; �...,., k. x.... �.s t .s.x �. .�. x.,. x�.�.� #, ..�+« �.. .a �:.. z=r .. ... x. .�...., ., t�.x a s.x,x: From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Friday, February 19, 2021 11:21 AM To: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil>; Homewood, Sue <sue.homewood@ncdenr.gov> Cc: Haywood, Casey M CIV (USA)<Casey.M.Haywood@usace.army.mil> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Chris, I have attached the updated PJD document to include the minor changes from last week. Thanks again for a productive and efficient site visit. I have asked the engineer to look at the small wetland we added near the crossing to see if it would be affected. If so, I will send an updated permit drawing and any impact data. Please let me know if you have any questions. Have a good weekend. Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 jeff.harbour(o)terracon.com I terracon.com From: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Sent: Wednesday, February 10, 2021 2:57 PM To: Harbour, Jeff W <Jeff.Harbour@terracon.com>; Homewood, Sue <sue.homewood@ncdenr.gov>; josh <josh@awck.com> Cc: Phil Ross <PRoss@awck.com>; Haywood, Casey M CIV (USA)<Casey.M.Haywood@usace.army.mil> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Thanks, Jeff: The Agent Authorization Form specifies tracts 152456 and 152443. The access you propose would traverse 152472. We are glad to first meet where you propose, but unless the form can be updated, Casey and I will wait by the vehicles until we can relocate to the cul-de-sac on Atlas Drive. We'll view the crossing from 152456. We have another site visit after this and are eyeing the weather tomorrow. We're also interested in being as expedient as possible tomorrow. Christopher D. Hopper Regulatory Specialist U.S. Army Corps of Engineers Regulatory Division 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 (919) 554-4884, Ext. 35 We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey can be accessed by copying and pasting the following link into your web browser: http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0. Thank you for taking the time to visit this site and complete the survey. From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Wednesday, February 10, 2021 12:50 PM To: Homewood, Sue <sue.homewood@ncdenr.gov>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil>; josh <josh@awck.com> Cc: Phil Ross <PRoss@awck.com>; Haywood, Casey M CIV (USA)<Casey.M.Haywood@usace.army.mil> Subject: [Non-DoD Source] RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision I would recommend that we initially meet at the following coordinates: 36.0544,-79.3430 This will get us to the sewer crossing location much faster and from there we can see the other few items that were delineation. This is also land is owned by the Scotts and we have permission through the agent authorization. Then if you wanted to g arou8nd to the other side then we can. I only have 3 hours tops to be onsite tomorrow so we need to make it as efficient as possible. See you all at 10am Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 jeff.harbour(o)terracon.com I terracon.com From: Homewood, Sue <sue.homewood@ncdenr.gov> Sent: Wednesday, February 10, 2021 11:13 AM To: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil>; Harbour, Jeff W <Jeff.Harbour@terracon.com>; josh <josh@awck.com> Cc: Phil Ross <PRoss@awck.com>; Haywood, Casey M CIV (USA)<Casey.M.Haywood@usace.army.mil> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Thanks for confirming Chris. I'll see you all there unless someone suggests a different meeting location. Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue. Homewood@ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 From: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Sent: Wednesday, February 10, 2021 10:13 AM To: Harbour, Jeff W <Jeff.Harbour@terracon.com>; josh <josh@awck.com>; Homewood, Sue <sue.homewood@ncdenr.gov> Cc: Phil Ross <PRoss@awck.com>; Haywood, Casey M CIV (USA)<Casey.M.Haywood@usace.army.mil> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Good Morning, Everyone: I'm writing to confirm tomorrow's site visit at 10 am for Riley's Meadow, and to firm up a meeting location. It appears the cul-de-sac immediately west of the site provides the most direct access (36.049041-79.347902). Does this sound like a good spot to meet, or did you have somewhere else in mind Jeff? If this has already been shared, my apologies for the oversight. They're calling for rain, but through the morning and early afternoon the amounts are very low (0.03 in./hr). Thanks! Christopher D. Hopper Regulatory Specialist U.S. Army Corps of Engineers Regulatory Division 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 (919) 554-4884, Ext. 35 We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey can be accessed by copying and pasting the following link into your web browser: http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0. Thank you for taking the time to visit this site and complete the survey. From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Thursday, February 4, 2021 1:03 PM To: Josh Johnson <josh@awck.com>; Homewood, Sue <sue.homewood@ncdenr.gov>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: Phil Ross <PRoss@awck.com> Subject: [Non-DoD Source] RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Josh, We did not request a determination from Sue and just submitted the PCN for the 401 WQC. The soils map makes it extremely hard to ID mapped features as you can see. The main stream along the north boundary is buffered and the mapped feature along the east side has an origin point just inside the site. We will look at it with Sue next week Sue, I do think the original soil map I sent with the PCN is incorrect. This one should be accurate Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 ieff.harbour(o)terracon.com I terracon.com From: Josh Johnson <iosh@awck.com> Sent: Thursday, February 4, 2021 10:51 AM To: Harbour, Jeff W <Jeff.Harbour@terracon.com>; Homewood, Sue <sue.homewood@ncdenr.gov>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: Phil Ross <PRoss@awck.com> Subject: Re: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Good Morning Jeff, We can (and will) accept Sue's field determination or you can coordinate directly with us on the field work. I've copied Phil Ross onto this email if you need to coordinate the field work. A first step in that would be to submit a copy of the package that you submitted to DWR. For the actual buffer authorization, you'll need to complete the attached authorization application and include with it the appropriate exhibits and the field determination from Sue. Thanks Joshua S. Johnson, P.E. Vice President, Head of Engineering Alley, Williams, Carmen, and King, Inc. Tel. (336) 226-5534 Cell: (336) 266-8792 From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Thursday, February 4, 2021 10:35 AM To: Homewood, Sue <sue.homewood@ncdenr.gov>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: Josh Johnson <iosh@awck.com> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Josh, Just checking with you regarding this email string.... Thanks Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 ieff.harbour(o)terracon.com I terracon.com From: Harbour, Jeff W Sent: Thursday, January 28, 2021 11:29 AM To: Homewood, Sue <sue.homewood@ncdenr.gov>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: josh <josh@awck.com> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Thanks Sue. Josh, please let me know what you may need from me regarding this proposed project. Regards, Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 jeff.harbour(o)terracon.com I terracon.com From: Homewood, Sue <sue.homewood@ncdenr.gov> Sent: Thursday, January 28, 2021 9:59 AM To: Harbour, Jeff W <Jeff.Harbour@terracon.com>; Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: josh <josh@awck.com> Subject: RE: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision Hi Jeff, On another note, the Jordan Lake Riparian Buffer rules are delegated to the local municipalities to implement, therefore my review and final decision will not include the impacts you listed on the PCN for the riparian buffers. Those will have to be applied for and approved by the Town. I'm copying Josh Johnson with Alley, Williams, Carmen and King who is contracted by the Town to handle their buffer program. See you in a couple weeks. Sue Homewood Division of Water Resources, Winston Salem Regional Office Department of Environmental Quality 336 776 9693 office 336 813 1863 mobile Sue.Homewood@ncdenr.gov 450 W. Hanes Mill Rd, Suite 300 Winston Salem NC 27105 %; K.e -f,� a ,. � 1, ...# .. a :. .gyp From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Wednesday, January 27, 2021 10:20 AM To: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: Homewood, Sue <sue.homewood@ncdenr.gov> Subject: [External] RE: SAW-2021-00065 - Riley's Meadow Subdivision CAUTION: External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to Report Spam. Chris, By "application" are you referring to a PJD request? If so, I can put together and get it to you asap. 10am on the 11t" is good. Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 jeff.harbour(o)terracon.com I terracon.com From: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Sent: Wednesday, January 27, 2021 6:00 AM To: Harbour, Jeff W <Jeff.Harbour@terracon.com> Cc: Homewood, Sue <sue.homewood@ncdenr.gov> Subject: RE: SAW-2021-00065 - Riley's Meadow Subdivision Thanks, Jeff: You are correct that a PJD doesn't have to be issued to secure a permit, but in my system I first have to identify a feature as subject to 404 before I can authorize impacts to it. All stream lengths/widths/permanence/names and wetland areas/types/etc. need to be recorded. If an application was prepared, please send it along so I can establish my jurisdiction to issue a permit. It sounds like the 11t" of February is a common date — lets aim for 10am? Christopher D. Hopper Regulatory Specialist U.S. Army Corps of Engineers Regulatory Division 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 (919) 554-4884, Ext. 35 We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey can be accessed by copying and pasting the following link into your web browser: http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0. Thank you for taking the time to visit this site and complete the survey. From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Tuesday, January 26, 2021 6:01 PM To: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Cc: Homewood, Sue <sue.homewood@ncdenr.gov> Subject: [Non-DoD Source] RE: SAW-2021-00065 - Riley's Meadow Subdivision I am open the 11t". The delineation was straight forward with no problem areas. Therefore I didn't submit a PJD request since its not a requirement for the application. The one main stream is the only mapped and buffered feature that we encountered onsite. No features that we are asking for a buffer exemption on. Let me know what time and we'll set it up. Thanks Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 jeff.harbour(o)terracon.com I terracon.com From: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Sent: Tuesday, January 26, 2021 5:04 PM To: Harbour, Jeff W <Jeff.Harbour@terracon.com> Cc: Homewood, Sue <sue.homewood@ncdenr.gov> Subject: RE: SAW-2021-00065 - Riley's Meadow Subdivision Thanks for the agent authorization form, Jeff: You mention in the application that areas have been delineated but no verification has been performed. I looked through my files but I don't see an application pending for this site. Has one been submitted (I've only had Alamance County for about a year so it's possible I need to retrieve that from someone else)? I'd like to set up a site visit for this if possible. At the moment I have February 5, 10, and 11 open. I have cc'd Sue Homewood to check her availability as well. The local governments often request a staff member participate due to their riparian buffer program (as an FYI). Christopher D. Hopper Regulatory Specialist U.S. Army Corps of Engineers Regulatory Division 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 (919) 554-4884, Ext. 35 We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey can be accessed by copying and pasting the following link into your web browser: http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0. Thank you for taking the time to visit this site and complete the survey. From: Harbour, Jeff W <Jeff.Harbour@terracon.com> Sent: Tuesday, January 26, 2021 9:15 AM To: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Subject: [Non-DoD Source] FW: SAW-2021-00065 - Riley's Meadow Subdivision Did you have questions about the application? Thanks Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 ieff.harbour(o)terracon.com I terracon.com From: Harbour, Jeff W Sent: Thursday, January 21, 2021 1:03 PM To: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Subject: RE: SAW-2021-00065 - Riley's Meadow Subdivision Chris, See attached, sorry about that Jeff Harbour, PWS Senior Scientist — Natural Resources Terracon Consultants, Inc. 2401 Brentwood Rd., Suite 1071 Raleigh, North Carolina 27604 D (919) 547-1080 1 M (919) 805-4208 jeff.harbour(o)terracon.com I terracon.com From: Hopper, Christopher D CIV (USA) <Christopher.D.Hopper@usace.army.mil> Sent: Wednesday, January 20, 2021 9:24 AM To: Harbour, Jeff W <Jeff.Harbour@terracon.com> Subject: SAW-2021-00065 - Riley's Meadow Subdivision Good Moring Jeff: Can you please complete the agent authorization letter included in your application (name, email, phone, address, site information — are all left blank). Once I receive it I have a couple questions for you about the application. Thanks in advance, Christopher D. Hopper 10 Regulatory Specialist U.S. Army Corps of Engineers Regulatory Division 3331 Heritage Trade Drive, Suite 105 Wake Forest, NC 27587 (919) 554-4884, Ext. 35 We would appreciate your feedback on how we are performing our duties. Our automated Customer Service Survey can be accessed by copying and pasting the following link into your web browser: http://corpsmapu.usace.army.mil/cm apex/f?p=136:4:0. Thank you for taking the time to visit this site and complete the survey. Terracon provides environmental, facilities, geotechnical, and materials consulting engineering services delivered with responsiveness, resourcefulness, and reliability. Private and confidential as detailed here (www.terracon.com/disclaimer). If you cannot access the hyperlink, please e-mail sender. 11 000:., .:.:.:.:.:... . NEWS REAM I0ACy#1 FOR SANITARY SEWER EMP* SCREAM IMPA&: 50 F ::pRc/FGSED SEWER TOTAL AREA,'6068 SF /ZONE 1: 4397 8F C O J IEC TIG`N ' �D f ZONE 2;'1666!SF TEM .WETLAND INtpACT:i56 ''S WETLAEV`�tif. ;' [ AREXA. ) 1 .. z ,m X. F�L CVNG PIPES bN PIERS, _Ct `E:::::::: i 51 ST FAMB,LD DISTURBANC :.............. t NEWSSMH 6 OA CONS. .... : i:::::. a;f7 too-YR FLOOD. 2 ` 5 1 3 PIERS Wl I�AAX GROUND 26.o0 5 40 SPANS O.C. �:::: ti ; ::::: :: :. ::. m TOP: 527.yo ; - F INV OUT: 5�4.27 - <--- ; ;' �_ ;------- f ::': ' :°.1:` 223 H 1 r---`� t-- PLANS PREPARED BY: B&F CONSULTING, INC. 2805 TOBERMORY LANE RALEIGH, NC 27606 PHONE: 919-618-0180 LICENSE NO: C-2149 S,M H OP 523.38 `,I V IN 515.63 V OUT 515.53 X 5' DIA M H R ISE CONE & UTSIDE DROP EW FLAT TOP: 525.15 INV IN (TOP): 523.15 NV IN (DROP): 516.20 STIR SHB 000 00. s a�, � T :sy I \ ro \ ` 4/ SSMFi'\, \ n / \ \ TOP 529.39 \\\ INV IN 516.19 \ / \INV OUT 516.04 $6, 57s hy5 m IMPACT LO TIO Spa / VICINITY MAP N.T.S. RILEY'S MEADOW EXHIBIT FOR SEWER IMPACT DATED: MARCH 2, 2021 SCALE: 1 "=60' PRELIMINARY - DO NOT USE FOR CONSTRUCTION 545 17+00 � 10" MECH s- -LsOK RESTF s s • s—s— 100 YRy- FLOOD s sus—s�s�s�s—kS=9=!--- =D JT PIPE 23.53 LF 3- DIP O=- 540 't Q � � o N �35 ��coLoLo U) co Lo Lo XLn0z�00 ry OLU-Z�> = X Q X w w z �wil�wZZuxb30 525 520 O `z' 515 - - 40' TYP NOTES: 1. RESTRAINED JOINT PIPE WILL BE CENTERED ON CONCRETE PIERS CONCRETE PIERS WILL BE MAXIMUM 40 FT. O CENTER 2. FOOTINGS FOR CONCRETE PIERS SHALL 13E PLACED ON STABLE SUBGRADE APPROVED BY THE GEOTE HNICAL ENGINEE . TOP OF ALL FOOTINGS SHALL BE AT LEA T 18" BELOW GR DE. STABILIZATION STONE SHALL IBE USED WHEN GROUNDW TER IS ENCOUNTERED DURING FOOTING INSTALL TION (12" MIN) 510 +50 18+00 +50 19+00 +50 20+00 PLANS PREPARED BY: B&F CONSULTING, INC. 2805 TOBERMORY LANE RALEIGH, NC 27606 PHONE: 919-618-0180 LICENSE NO: C-2149 RILEY'S MEADOW EXHIBIT FOR SEWER TIE TO OUTFALL DATED: MARCH 2, 2021 SCALE: 1 "=50' PRELIMINARY - DO NOT USE FOR CONSTRUCTION