HomeMy WebLinkAboutWQ0038378_Final Permit_20210305ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. DANI£L SMITH
Director
NORTH CAROLINA
Environmental Quality
March 5, 2021
LARRY S. AND PAMELA M. WINTERS
2024 BOYCE BRIDGE ROAD
CREEDMOOR, NORTH CAROLINA 27522-8022
Dear Mr. and Mrs. Winters:
Subject: Permit No. WQ0038378
2024 Boyce Bridge Rd. SFR
Single -Family Residence
Wastewater Irrigation System
Wake County
In accordance with your permit renewal request received December 17, 2020, and subsequent
additional information received March 1, 2021, we are forwarding herewith Permit No. WQ0038378 dated
March 5, 2021, to Larry S. and Pamela M. Winters for the continued operation of the subject single-family
residence wastewater treatment and irrigation facilities. Please note that this renewed permit shall become
effective on June 1, 2021 (i.e., the day after the expiration date of the existing permit).
This permit shall be effective from June 1, 2021 through July 31, 2027, shall void Permit No.
WQ0038378 issued June 1, 2016, and shall be subject to the conditions and limitations therein. The
Permittee shall submit a renewal application no later than February 1, 2027.
Please pay attention to the operation and maintenance requirements listed in Section III for they
may differ from the previous permit issuance. Failure to establish an adequate system for collecting and
maintaining the required operational information shall result in future compliance problems.
The Division has removed the following permit conditions since the last permit issuance dated
June 1, 2016:
➢ Old Condition I.I. — This condition has been removed because the engineering certification
was received June 27, 2017.
➢ Old Condition L2. — This condition has been removed because the start-up inspection was
conducted July 6, 2017.
➢ Old Condition L3. — This condition has been removed because the engineering certification
was received June 27, 2017.
➢ Old Condition IIL8. — This condition has been revised. Please see new Condition IIL8.
➢ Old Condition III.12. — This condition has been removed because the facility has been
constructed.
➢ Old Condition VI.2. — This condition has been removed because the permit is not voidable.
D Q
�� North Carolina Department of Environmental Quality I Division of Water Resources
512 North Salisbury Street 1 1617 Mail Service Center I Raleigh, North Carolina 27699-1617
NOR fH CA�in!.INA
14'torenwmta�a"1 919,707.9000
Mr. Larry S. Winters and Mrs. Pamela M. Winters
March 5, 2021
Page 2 of 2
The following permit conditions are new since the last permit issuance dated June 1, 2016:
➢ Condition IIL 12. — Metering equipment shall be tested and calibrated annually.
➢ Condition VL 10. —This permit shall not be renewed if the Permittee or any affiliation has not
paid the required annual fee.
If any parts, requirements, or limitations contained in this permit are unacceptable, the Permittee
has the right to request an adjudicatory hearing upon written request within 30 days following receipt of
this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North
Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service
Center, Raleigh, NC 27699-6714. Otherwise, this permit shall be final and binding.
If you need additional information concerning this permit, please contact Poonam Giri at (919)
707-3656 or poonam.girikncdenr.gov.
Sincerely,
S. Daniel Smith, Director
Division of Water Resources
cc: Wake County Health Department (Electronic Copy)
Raleigh Regional Office, Water Quality Regional Operations Section (Electronic Copy)
Laserfiche File (Electronic Copy)
Digital Permit Archive (Electronic Copy)
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENTAL QUALITY
RALEIGH
SINGLE-FAMILY RESIDENCE WASTEWATER IRRIGATION SYSTEM PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as
amended, and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Larry S. And Pamela M. Winters
Wake County
FOR THE
continued operation of a 480 gallon per day (GPD) single-family residence wastewater treatment and
irrigation facility consisting o£
a 1,250 gallon septic tank with an effluent filter; an 800 gallon AdvanTex recirculation tank with a 28 gallon
per minute (GPM) recirculation pump; a 3,500 gallon storage/pump tank with a 12.5 GPM pump and
audible/visual high-water alarms; an Orenco ultraviolet (UV) disinfection unit; a rain moisture sensor; a
0.30 acre drip irrigation area consisting of three zones with a minimum of 4,000 linear feet (LF) of tubing
(4,918 feet to account for blanking) and nominal spacing of two feet; and all associated piping, valves,
controls, and appurtenances
to serve the single-family residence at 2024 Boyce Bridge Rd., Creedmoor, NC 27522, with no discharge
of wastes to surface waters, pursuant to the application received December 17, 2020, and subsequent
additional information received March 1, 2021, and in conformity with the Division -approved plans and
specifications considered a part of this permit.
This permit shall be effective from June 1, 2021 through July 31, 2027, shall void Permit No. WQ0038378
issued June 1, 2016, and shall be subject to the following conditions and limitations:
L SCHEDULES
1. The Permittee shall request renewal of this permit on Division -approved forms no later than February
1, 2027. [15A NCAC 02T .0105(b), 02T .0109]
2. If a public or community sewage system is or becomes available, the Permittee shall connect to this
system, and shall request rescission of the single-family residence wastewater treatment and irrigation
facilities permitted herein. [15A NCAC 02T .0607]
WQ0038378 Version 2.0 Shell Version 200201 Page 1 of 7
IL PERFORMANCE STANDARDS
The Permittee shall maintain and operate the subject non -discharge facilities so there is no discharge to
surface waters, nor any contravention of groundwater or surface water standards. In the event the
facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper
operation and maintenance, or failure of the irrigation areas to assimilate the effluent, the Permittee
shall take immediate corrective actions, including Division required actions, such as the construction
of additional or replacement wastewater treatment or disposal facilities. [15A NCAC 02T
.0108(b)(1)(A)]
2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface
water resulting from the operation of this facility. [15A NCAC 02T .0108(b)(1)(A)]
3. The Permittee shall apply treated wastewater effluent at or below the following rates:
TABLE 1— APPLICATION LIMITATIONS
Field
Parameter
Hourly Rate
Yearly Max
Units
1
01284 — Non -Discharge Application Rate
0.213
21.51
inches
[15A NCAC 02T .06050)]
4. The Permittee shall only apply treated wastewater effluent to the following:
TABLE 2 — IRRIGATION AREA INFORMATION
Net
Dominant
Field
Owner
County
Latitude
Longitude
Acreage
Soil Series
Larry S. and Pamela M.
CrB- Creedmoor sandy
1
Wake
36.061413'
-78.705047'
0.30
Winters
loam, 2-6% slopes
[I5A NCAC 02T .0 1 08(b)(1)(A)]
5. The attached Operation and Maintenance Agreement shall be a condition of this permit.
Noncompliance with the terms of the Operation and Maintenance Agreement shall subject the Permittee
to all sanctions under G. S. 143-215.6A, G.S. 143-215.613, and G.S. 143-215.6C for violation of or
failure to act in accordance with the terms and conditions of this permit. [15A NCAC 02T .0604(h)]
6. The Permittee shall connect the irrigation system to a rain or moisture sensor designed to prevent
irrigation during precipitation events or wet conditions. [15A NCAC 02T .0605(o)]
7. The compliance boundary is the property boundary. Any exceedance of groundwater standards at or
beyond the compliance boundary shall require corrective action. Division -approved relocation of the
compliance boundary shall be noted in Condition IL4. Multiple contiguous properties under common
ownership and permitted for use as a disposal system shall be treated as a single property with regard
to determination of a compliance boundary. [15A NCAC 02L .0106(d)(2), 02L .0107(i), 02T .0105(h),
G.S. 143-215.1(1), G.S. 143-215.1(k)]
8. The review boundary is midway between the compliance boundary and the effluent disposal area. Any
exceedance of groundwater standards at or beyond the review boundary shall require preventative
action. [15A NCAC 02L .0106(d)(1), 02L .0108]
9. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to
any sale or transfer of property affecting a compliance boundary (i.e., parcel subdivision). [ 15A NCAC
02L .0107(c)]
WQ0038378 Version 2.0 Shell Version 200201 Page 2 of 7
10. The facilities herein were permitted per the following setbacks:
a. The irrigation sites were originally permitted June 1, 2016. The setbacks for drip irrigation sites
originally permitted or modified from September 1, 2006 to August 31, 2018 are as follows (all
distances in feet):
I. Each habitable residence or place of assembly under separate ownership: 1001
ii. Each habitable residence or place of assembly owned by the Permittee: 15
iii. Each private or public water supply source: 100
iv. Surface waters: 100
v. Groundwater lowering ditches: 100
vi. Surface water diversions: 25
vii. Each well with exception of monitoring wells: 100
viii. Each property line: 50
ix. Top of slope of embankments or cuts of two feet or more in vertical height: 15
x. Each water line: 10
xi. Subsurface groundwater lowering drainage systems: 100
xii. Each swimming pool: 100
xiii. Public right of way: 50
xiv. Nitrification field: 20
xv. Each building foundation or basement: 15
1 Habitable residences or places of assembly under separate ownership constructed after the
facilities herein were originally permitted or subsequently modified are exempt from this
setback.
2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the
Permittee is leasing, owns both parcels separated by the property line.
[15A NCAC 02T .0606(a), 02T .0606(d), 02T .0606(e)]
b. The storage and treatment units were originally permitted June 1, 2016. The setbacks for storage
and treatment units originally permitted or modified from September 1, 2006 to August 31, 2018
are as follows (all distances in feet):
I. Each habitable residence or place of assembly under separate ownership: 1001
ii. Each private or public water supply source: 100
iii. Surface waters: 50
iv. Each well with exception of monitoring wells: 100
v. Each property line: 50 Z
1 Habitable residences or places of assembly under separate ownership constructed after the
facilities herein were originally permitted or subsequently modified are exempt from this
setback.
2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the
Permittee is leasing, owns both parcels separated by the property line.
[15A NCAC 02T .0606(b), 02T .0606(d), 02T .0606(e)]
WQ0038378 Version 2.0 Shell Version 200201 Page 3 of 7
III. OPERATION AND MAINTENANCE REQUIREMENTS
1. The Permittee shall operate and maintain the subject facilities as anon -discharge system. [15A NCAC
02T .0600]
2. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC)
classification of the subject non -discharge facilities, the Permittee shall designate and employ a certified
operator in responsible charge (ORC), and one or more certified operators as back-up ORCs. The ORC
or their back-up shall operate and visit the facilities as required by the WPCSOCC. [15A NCAC 02T
.0117]
3. The Permittee shall maintain vegetative cover on the irrigation sites, such that crop health is optimal,
allows even effluent distribution, and allows inspection of the irrigation system. [15A NCAC 02T
.0608(a)]
4. The Permittee shall take measures to prevent effluent ponding in or runoff from the irrigation sites
listed in Condition IL4. [15A NCAC 02T .0608(b)]
5. The Permittee shall not irrigate treated effluent during inclement weather, or when the soil is in a
condition that will cause ponding or runoff. [15A NCAC 02T .0605(o)]
6. The Permittee shall only irrigate treated effluent from the single-family residence at 2024 Boyce Bridge
Rd., Creedmoor NC 27522 on the sites listed in Condition IL4. [15A NCAC 02T .0601]
7. The Permittee shall not allow vehicles or heavy machinery on the irrigation area, except during
equipment installation or maintenance activities. [15A NCAC 02T .0608(d)]
8. The Permittee shall prohibit public access to the wastewater treatment and irrigation facilities through
lockable treatment units, and fencing around the irrigation sites. [15A NCAC 02T .0605(i)]
9. The Permittee shall dispose or utilize generated residuals in a Division -approved manner. [15A NCAC
02T .1100].
10. The Permittee shall not divert or bypass untreated or partially treated wastewater from the subject
facilities. [15A NCAC 02T .0605(f)]
11. Pump tanks shall have audible and visual alarms external to any structure. [15A NCAC 02T .0605(n)]
12. Metering equipment shall be tested and calibrated annually. [15A NCAC 02T .0608(c)]
13. The Permittee is responsible for the operation and maintenance of the wastewater treatment and
irrigation system including the following:
a. Inspect the septic tank annually, and pump out solids as needed. Inspect and clean the septic tank
effluent filter annually.
b. Inspect the ultraviolet disinfection unit weekly. Clean or replace the lamps and quartz sleeves as
needed.
c. Inspect all storage tanks, pumps, and alarms monthly. Remove the floating scum layer in all
pump/storage tanks when pumping the septic tank solids out.
d. Inspect the drip irrigation system monthly to verify: proper operation of the drip lines; that there
are no leaks; that vegetative growth does not obstruct the drip emitters; that the irrigated wastewater
is not ponding in or running off the designated irrigation area; and that there are no objectionable
odors.
[15A NCAC 02T .0608]
WQ0038378 Version 2.0 Shell Version 200201 Page 4 of 7
IV. MONITORING AND REPORTING REQUIREMENTS
The Permittee shall conduct and report any Division required monitoring necessary to evaluate this
facility's impact on groundwater and surface water. [15A NCAC 02T .0108(c)]
2. Noncompliance Notification:
The Permittee shall report to the Raleigh Regional Office, telephone number (919) 791-4200, within
24 hours of first knowledge of the following:
a. Any process unit failure (e.g., mechanical, electrical, etc.) rendering the facility incapable of
adequate wastewater treatment.
b. Any facility failure resulting in a discharge to surface waters.
c. Any time self -monitoring indicates the facility has gone out of compliance with its permit
limitations.
d. Ponding in or runoff from the irrigation sites.
Emergencies requiring reporting outside normal business hours shall call the Division's Emergency
Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. All
noncompliance notifications shall file a written report to the Raleigh Regional Office within five days
of first knowledge of the occurrence, and this report shall outline the actions proposed or taken to ensure
the problem does not recur. [15A NCAC 02T .0108(b)(1)(A)]
V. INSPECTIONS
1. The Permittee shall perform inspections and maintenance to ensure proper operation of the wastewater
treatment and irrigation facilities. [15A NCAC 02T .0608(f)]
2. The Permittee shall inspect the wastewater treatment and irrigation facilities to prevent malfunctions,
facility deterioration, and operator errors that may result in discharges of wastes to the environment,
threats to human health, or public nuisances. The Permittee shall maintain an inspection log that
includes the date and time of inspection, observations made, and maintenance, repairs, or corrective
actions taken. The Permittee shall maintain this inspection log for a period of five years from the date
of the inspection, and this log shall be made available to the Division upon request. [15A NCAC 02T
.0608(e), 02T .0608(f)]
Division authorized representatives may, upon presentation of credentials, enter and inspect any
property, premises, or place related to the wastewater treatment and irrigation facilities permitted herein
at any reasonable time for determining compliance with this permit. Division authorized
representatives may inspect or copy records maintained under the terms and conditions of this permit,
and may collect groundwater, surface water, or leachate samples. [G.S. 143-215.3(a)(2)]
WQ0038378 Version 2.0 Shell Version 200201 Page 5 of 7
VI. GENERAL CONDITIONS
1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to a
Division enforcement action. [G.S. 143-215.6A, 143-215.613, 143-215.6C]
2. This permit is effective only with respect to the nature and volume of wastes described in the permit
application, and Division -approved plans and specifications. [G.S. 143-215.1(d)]
3. Unless specifically requested and approved in this permit, there are no variances to administrative codes
or general statutes governing the construction or operation of the facilities permitted herein. [15A
NCAC 02T .0105(n)]
4. The issuance of this permit does not exempt the Permittee from complying with all statutes, rules,
regulations, or ordinances that other jurisdictional government agencies (e.g., local, state, and federal)
may require. [15A NCAC 02T .0105(c)(6)]
5. If the permitted facilities change ownership, or the Penmittee changes their name, the Permittee shall
submit a permit modification request on Division -approved forms. The Permittee shall comply with
all terms and conditions of this permit until the permit is transferred to the successor -owner. [G.S. 143-
215.1(d3)]
6. The Permittee shall retain a set of Division -approved plans and specifications for the life of the facilities
permitted herein. [15A NCAC 02T .0105(o)]
7. The Permittee shall maintain this permit until the proper closure of all facilities permitted herein, or
until the facilities permitted herein are permitted by another authority. [15A NCAC 02T .01050)]
8. This permit is subject to revocation or modification upon 60-day notice from the Division Director, in
whole or part for:
a. violation of any terms or conditions of this permit or Administrative Code Title 15A Subchapter
02T;
b. obtaining a permit by misrepresentation or failure to disclose all relevant facts;
c. the Permittee's refusal to allow authorized Department employees upon presentation of credentials:
I. to enter the Permittee's premises where a system is located or where any records are required
to be kept;
ii. to have access to any permit required documents and records;
iii. to inspect any monitoring equipment or method as required in this permit; or
iv. to sample any pollutants;
d. the Permittee's failure to pay the annual fee for administering and compliance monitoring; or
e. a Division determination that the conditions of this permit are in conflict with North Carolina
Administrative Code or General Statutes.
[15A NCAC 02T .0110]
WQ0038378 Version 2.0 Shell Version 200201 Page 6 of 7
9. Unless the Division Director grants a variance, expansion of the facilities permitted herein shall not
occur if any of the following apply:
a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of
environmental crimes under G.S. 143-215.6B, or under Federal law that would otherwise be
prosecuted under G.S. 143-215.6B, and all appeals of this conviction have been abandoned or
exhausted.
b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned
a wastewater treatment facility without properly closing the facility.
c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil
penalty, and all appeals of this penalty have been abandoned or exhausted.
d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant
with any compliance schedule in a permit, settlement agreement, or order.
e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual
fee.
[15A NCAC 02T .0120(b), 02T .0120(d)]
10. This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee.
[15A NCAC 02T .0120(c)]
Permit issued this the 5 h day of March 2021
NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION
S. Daniel Smith, Director
Division of Water Resources
By Authority of the Environmental Management Commission
Permit Number WQ0038378
WQ0038378 Version 2.0 Shell Version 200201 Page 7 of 7
State of North Carolina
DWI
Department of Environmental Quality
Division of Water Resources
SINGLE-FAMILY RESIDENCE WASTEWATER MIGATION SYSTEM
flan of Water Recce OPERATION AND MAINTENANCE AGREEMENT
FORM: SFRWWIS-O&M 09-18
Permit No. WQ0038378
County. Wake
Pernuttee: Larry and Pam Winters (i.e., all deeded property owners)
The Permittee agrees to operate and maintain the single-family residence wastewater treatment and irrigation system as
follows:
1. Inspect the septic tank annually, and pump out solids as needed.
2. Inspect and clean the septic tank effluent filter annually. (if applicable)
3. Inspect the tablet chlorinator weekly, Add wastewater grade chlorine tablets (e.g., calcium hypochlorite) as needed.
Swimming pool grade chlorine tablets are not acceptable. (if applicable)
4. Inspect the ultraviolet disinfection unit weekly. Clean or replace the lamps and quartz sleeves as needed. (if
applicable)
5. Inspect all storage tanks, pumps, and alarms monthly. Remove the floating scum layer in all pump/storage tanks
when pumping the septic tank solids out.
6. Inspect the spray irrigation system monthly to verify., proper operation of the spray heads; that there are no leaks;
that vegetative growth does not obstruct the spray heads; that the irrigated wastewater is not ponding in or running
off the designated irrigation area; and that there are no objectionabte odors. (if applicable)
7. Inspect the drip irrigation system monthly to verify: proper operation of the drip lines; that there are no leaks; that
vegetative growth does not obstruct the drip emitters; that the irrigated wastewater is not ponding in or running off
the designated irrigation area; and that there are no objectionable odors. [if applicable}
8. Maintain a set of Division -approved engineering plans and speciFications.
9. Pay the required annual fee.
10. Request renewal of this permit on Division -approved forms no later than 180 days prior to expiration.
11. Sign and provide a Chai�ge cif t��vsiershi p applicaii��ri to any future owner of the single-family residence wastewater
treatment and irrigation system for their completion and submission to the Division of Water Resources.
We understand the above requirements and agree to these ternls as part of the issued permit.
Signature: LarKy Winters Date: 1.211712020
Signature: Pam Winters
Signature:
Date: 121 1712020
Date:
Signature:
Date:
All deeded Property owners shall si n this D eration and Maintenance Agreement