Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
dean.hunkele
Coastal SWRule
Permitted Flow
6,700
Facility
Facility Name
Division Drive Commerce Park Private Sewer
Location Address
Owner
Owner Name
Bluebill Development LLC
Dates/Events
Scheduled
Orig Issue App Received Draft Initiated Issuance
10/13/2020 2/12/2021
Central Files: APS _ SWP _
2/18/2021
Permit Tracking Slip
Status
Project Type
In review
Major modification
Version
Permit Classification
B
Individual
Permit Contact Affiliation
Major/Minor Region
Minor Wilmington
County
New Hanover
Facility Contact Affiliation
Owner Type
Non -Government
Owner Affiliation
Robert M. High
324 Greenville Ave
Public Notice Issue Effective
_4ct- "3 —3—a i
NC 28403
Expiration
NORMS & TUNSTALL
CONSULTING ENGINEERS P.C.
2602 Iron Gate Drive, Suite 102
Wilmington, NC 28412
(910) 343-9653
(910) 343-9604 Fax
John S. Tunstall, P.E.
T. Jason Clark, P.E.
February 11, 2021
NC DEQ
Division of Water Resources
Water Quality Regional Operations Section
Wilmington Regional Office
127 Cardinal Drive Extension
Wilmington, NC 28405
Re: Gravity Sewer Extension
Division Commerce Park
149 Division Drive
New Hanover County
N&T Project No. 20036
Dear Sir or Madam:
1429 Ash -Little River Road
Ash, NC 28420
(910) 287-5900
(910) 287-5902 Fax
J. Phillip Norris, P.E.
Joseph K. Bland, P.E.
Thomas J. Scheetz, E.I.
'-kRp220i,
Fast -Track Permit Application Modification (WQ0042011)
Enclosed is one (1) original application form, one (1) copy of the Sewer Narrative, one (1) original
Flow Tracking / Acceptance Form (FTSE 10-18) from the Cape Fear Public Utility Authority, one
(1) 8'/2 x 11 color USGS Topographic Map, one (1) site plan (ledger size) and a $480.00 check
for the processing fee.
Please review this information for approval and contact us with any questions or comments you
may have. Thank you for your assistance on this project.
Sincerely,
NORRIS & TUNSTALL
CONSULTING ENGINEERS, P.C.
�vtt .S . at'1�3-lw
Jo n S. Tunstall, P.E.
JST/asn
20036 02-11-21-s-swr-mod-ltr
Enclosures
cc: Robert High / Bluebill Development, LLC (by E-Mail Only)
NCBELS Liccnse C-3641
SEWER NARRATIVE
DIVISION COMMERCE PARK
149 Division Drive
Wilmington, North Carolina
For
Bluebill Development, LLC
324 Greenville Avenue
Wilmington, NC 28403
(910)790-9490
SEAL r
030869
✓SON •G�PQ`
Revised February 2021 (Owner Revision)
July 2020
Prepared by:
NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C.
2602 Iron Gate Drive, Suite 102
Wilmington, North Carolina 28412
(910) 343-9653
(910)343-9604 (Fax)
License # C-3641
N&T Project # 20036
NARRATIVE
SEWER SYSTEM:
ORIGINAL 2020 DESIGN:
This private gravity system is designed to service a six (6) building office / warehouse
site with approximately 268 employees. A total of 408 LF of 8-inch sewer line will be
designed to serve the site. This new system will not require a pump station. It will
connect into an existing manhole in an existing public utility easement adjacent to
Division Drive.
THIS SUBMITTAL - FEBRUARY 2021:
This submittal modifies State Sewer Permit WQ0042011, issued 10-13-2020. This
submittal is for building office/warehouse site with approximately 76 employees with a
total flow of 1,900 GPD. A total of 147 LF of 8-inch Gravity Sewer Line will serve the
site.
These revisions reflect a reduction in flow from 6,700 GPD to 1,900 GPD and a
reduction in 8-inch Gravity Sewer Line from 408 LF to 147 LF.
This will be Private Sewer and will connect into an existing manhole in an existing public
utility easement adjacent to Division Drive.
This system will be served by the Cape Fear Public Utility Authority.
DWR
Division of Water Resources
State of North Carolina
Department of Environmental Quality
Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number:
(to be completed by DWR)
All items must be completed or the aoulication will be returned
L APPLICANT INFORMATION:
1. Applicant's name: Bluebill Development. LLC. (company, municipality, HOA, utility, etc.)
2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ❑ State/County ❑ Municipal ❑ Other
3. Signature authority's name: Robert M. High per 15A NCAC 02T .0106(b)
Title: Member
4. Applicant's mailing address: 324 Greenville Avenue
City: Wilmington State: NC Zip: 28403-
5. Applicant's contact information:
Phone number: (910) 790-9490 Email Address: robert@roberthighdevelopment.com
II. PROJECT INFORMATION:
1. Project name: Division Commerce Park
2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Project
If a modification, provide the existing permit number: W00042011 and issued date: 10-13-2020
If new construction but part of a master plan, provide the existing permit number: W000
3. County where project is located: New Hanover
4. Approximate Coordinates (Decimal Degrees): Latitude: 34.00 Longitude: -77.00
5. Parcel ID (if applicable): R04100-004-007-000
(or Parcel ID to closest downstream sewer)
III. CONSULTANT INFORMATION:
1. Professional Engineer: T. Jason Clark, P.E. License Number: 030869
Firm: Norris & Tunstall Consulting Engineers, P.C.
Mailing address: 2602 Iron Gate Drive, Suite 102
City: Wilmington State: NC Zip: 28412-
Phone number: (NO) 343-9653 Email Address: iclark@ntengineers.com & anorris@ntengineers.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: James A. Loughlin (Northside WWTP) Permit Number: NC 0023965
Owner Name: Cane Fear Public Utility Authority
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ_
System Wide Collection System Permit Number(s) (if applicable): WQCS
Owner Name(s): Cape Fear Public Utility Authority
FORM: FTA 04-16 Page 1 of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes [-]No ®N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes []No ®N/A
3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached?
❑ Yes [-]No ®N/A
4. Origin of wastewater: (check all that apply):
❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
® Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial % Commercial
% Industrial (See 15A NCAC 02T .0103(20))
"Is there a Pretreatment Program in effect? ❑ Yes [-]No
6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? []Yes ❑ No
➢ If Yes, provide a copy of flow reduction approval letter
7. Summarize wastewater generated by project:
Establishment Type (see 021.0114(fl)
Daily Design Flow °,b
No. of Units
Flow
Office / Warehouse (19 Units = 76 Emp)
25 gal/Employee
76
1,900 GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
1,900 GPD
a See 15A NCAC 02T .0114(bb1. (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0I 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 1 900 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
❑ Flow has already been allocated in Permit Number:
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers):
I. Summarize gravity sewer to be permitted:
Size (inches) Length (feet) Material
8" 147 PVC
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIII. PUMP STATION DESIGN CRITERIA (If Applicable)-02T.0305 & MDC (Pump Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name:
2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - °
3. Design flow of the pump station: millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): _ gallons per minute at feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches) Length (feet) Material
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B)_
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)):
1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g)
➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
® Yes [-]No
Setback Parameter"
Separation Required
Storm sewers and other utilities not listed below vertical
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feet
*"Any private or public water supply source, including any wells, WS-I waters of Class I or
Class lI impounded reservoirs used as a source of drinking water
100 feet
*"Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
"Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Draina e systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved.
➢ "*Stream classifications can be identified using the Division's NC Surface Water Classifications webnage
➢ If noncompliance with 02T.0305(f) or (g). see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No
➢ See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No
➢ This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No
➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters
➢ Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)?
® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ® No
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
I. Does the submitted system comply with 15A NCAC 021, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the ¢mvity $ewer Minimum Design Criteria (latest version) as applicable?
® Yes ❑ No
If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for
review. Anproval of the request Is required Prior to submittal of the Fast Track Application and supporting documents
2. Professional Engineer's Certification:
_ _ attest that this application for
IN.,, f on Application Item III.I.)
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the besi
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed Oils material and
havejudged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143.215.6A and 143.215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
North Carolina Professional Engineer's seal, signature, and data
yr : 7
SEAL
IN
i gSON G
3. Applicant's Certification per 15A NCAC 02T .0106(b):
t attest that this application for
name & htle from Application Item I. J
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from Otis non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated, I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE. — In accordance with Gcneral Statutes 143.215.6A and 143-215.6D, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation.
Signature: Date: 2-/ 4/2-/
FORM: FTA 04.16 Page 5 of 5
N� Q o031� (� i)
State of North Carolina
[MR
Department of Environmental Quality
Division of Water Resources
Division of water Resources Flow Tracking for Sewer Extension Applications
(FTSE 10-18)
Entity Requesting Allocation: Bluebill Development, LLC
Project Name for which flow is being requested: Division Commerce Park
More than one FTSE maybe required jar a single project if the owner of the WWTP is not responsible for all pump
stations along the route of the proposed wastewater flow.
I. Complete this section only if you are the owner of the wastewater treatment plant.
a. WWTP Facility Name: James A. Loughlin (Northside) WWTP
b. WWTP Facility Permit #: NPDES NC 0023965
All flows are in MGD
c. WWTP facility's permitted flow 16.000
d. Estimated obligated flow not yet tributary to the WWTP 3.598
e. WWTP facility's actual avg. flow 10.661
f. Total flow for this specific request 0.001900
g. Total actual and obligated flows to the facility 14.261
h. Percent of permitted flow used 89.1
II. Complete this section for each pump station you are responsible for along the route of this proposed
wastewater flow.
List pump stations located between the project connection point and the WWTP:
(A)
(B)
(C)
(D)=(B+C)
(E)=(A-D)
Design
Obligated,
Pump
Pump
Average
Approx.
Not Yet
Total Current
Station
Station
Firm
Daily Flow**
Current
Tributary
Flow Plus
(Name or
Permit
Capacity, *
(Firm / pf),
Avg. Daily
Daily Flow,
Obligated
Available
Number)
No.
MGD
MGD
Flow, MGD
MGD
Flow
Capacity***
44
N/A
0.864
0.346
0.053
0.147
0.199
0.146
* The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow
that can be achieved with the largest pump taken out of service.
** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor
(pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria.
*** A Planning Assessment Addendum shall be attached for each pump station located
between the project connection point and the WWTP where the Available Capacity is < 0.
Downstream Facility Name (Sewer): Cape Fear Public Utility Authority
Downstream Permit Number:
Page 1 of 6
FTSE 10-18
III. Certification Statement:
I Jeff Theberge, CFPUA Eng. Mgr certify to the best of my knowledge that the addition of
the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving
wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity
related sanitary sewer overflows or overburden any downstream pump station en route to the receiving
treatment plant under normal circumstances, given the implementation of the planned improvements
identified in the planning assessment where applicable. This analysis has been performed in accordance
with local established policies and procedures using the best available data. This certification applies to
those items listed above in Sections I and II plus all attached planning assessment addendums for which I
am the responsible party. Signature of this form certifies that the receiving collection system or treatment
works has adequate capacity to transport and treat the proposed new wastewater.
2/8/2021
Official Signature Date
Engineering Manager
Title of Signing Official
Page 2 of 6