Loading...
HomeMy WebLinkAboutWQ0042272_Application (FTSE)_20210302Central Files: APS _ SWP 1/28/2021 Permit Number W00042272 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow Facility Facility Name Pine Forest Plantation Amenity Center Pump Station Location Address Owner Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County Brunswick Facility Contact Affiliation Owner Name Owner Type Brunswick County Government - County Owner Affiliation John Nichols PE PO Box 249 Dates/Events Bolivia NC 2842202, Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 1/26/2021��� pARAMOUNTE t E N G 1 N E E Ft I N G. I N C�. JAN 2 6 2021 1 2 2 C I N E M A D R I V E W I L M I N G T O N N C 2 8 4 0 3 '�'•- 9 1 0- 7 9 1- 6 7 0 7( O) 9 1 0- 7 9 1- 6 7 6 0 ( F) L E T T E R O F T R A N S M I T T A 1. To: NCDEQ Date 1 1/25/21 127 N. Cardinal Drive Wilmington, NC 28405 Re: Pine Forest Plantation Amenity 910 796-7215 Fast Track Sewer Attn: Dean Hunkele Project No. I 16313.PE e are sendin ® Originals ® Prints ❑ Shop Drawings ❑ Calculations ❑ Correspondence ❑ Plans ❑ Specifications ❑ Other as listed below he following items: Quantity Date Dwg. No. Description 2 Fast Track Sewer Permit FTA 04-16 (original and 1 co 2 Flow Tracking/Acceptance Sewer Extension Application FTSE 04-16 (original and 1 co 1 Brunswick County Approval Letter 1 Sanitary Sewer Narrative 1 Vicinity Ma 1 Site Plan 1 $480 check Issue Status: ® For Approval ❑ As Requested ❑ Construction ❑ Bid ❑ For Your Use ® For Review and Comment ❑ Approved as Noted ❑ See Remarks ction Taken: ❑ No Exceptions Taken ❑ Make Corrections Noted ❑ Amend & Resubmit ❑ Rejected - See Remarks ❑ Approved as Submitted ❑ Other emarks: Enclosed is the submittal for the Pine Forest Amenitv Cc: Signed: Tim Clinkscales, PE, PLS PROJECT NARRATIVE Pine Forest Plantation is proposing the sewer for the amenity center. In previous approvals, the Affinity Health at Pine Forest Private Pump Station (WQ0040826 dated 6/3/19) was to tie to the constructed forcemain along Pine Forest Drive. This pump station was designed in this manner because of timing of master pump station for the Pine Forest neighborhood. Since the master pump station was constructed and certified before the Affinity Health facility, sewer from this facility now gravity drains to a manhole that goes to the master pump station. With this information and discussion with county, we are proposing a county owned pump station as provided. This pump station is the only pump on the forcemain therefore is not part of an alternate sewer system. The pump station will operate 20 GPM @ 160 TDH. State of North Carolina DWR Department of Environmental Quality Division of Water Resources Division of Water Resources 15A NCAC 02T.0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING 'I DOCUMENTATION Application Number: W� `�� Ito be completed by DWP,) All items must be comolerad or the lication will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Brunswick Count (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State/County Cl Municipal ❑ Other 3. Signature authority's name: William Pinnix per 15—ANCAC 02T 010 tht Title: Director o_ f Engineering 4. Applicant's mailing address: PO Box_ 249 Bld31 City: Bolivia State: NC Zip: 2 422-_ 5. Applicant's contact information: Phone number: (2LOJ 253- 500 Email Address: william l innix(abrunswickc_ ountvnc,Loy It. PROJECT INFORMATION: I. Project name: Pine Forest Amenity 2. Applicatiow'Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00__ and issued date: _ If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Brunswick 4. Approximate Coordinates (Decimal Degrees): Latitude: 33,9684' Longitude: -7 0988° 5. Parcel ID (if applicable): 2030001714 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: I, Professional Engineer: Tim Clinkscales License Number: 28847 Finn: Pamnountc Engineering. Inc Mailing address: 122 Cinema Drive City: M11MLmIton State: NC Zip: 28403-_ Phone number: (2n)191-6707 Email Address: dwithers(o,paramounte onz cone IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: Facility Name: West Brunswick Regional WWTF Permit Number: W0002369-3 Owner Name: Brunswick Cot my V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): L Permit Number(s): WQ0039g 9 Downstream (Receiving) Sewer Size: ( g) 2 inch System WideCan System Permit Number(s) hf iip licable): WQCS 0284 Owner Name(s): Brunswick Chanty FORM: FTA 04-16 Page I of5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached'? ❑ Yes []No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached'? ❑ Yes []No ®NIA 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached'? ❑ Yes ❑No ®NIA 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ® Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming PooliFilter Backwash ❑ 13usinesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater : % Domestic/Commercial 100 % Commercial _ % Industrial (Sec 15A NCAC 02T .0103(20)) "is there a Pretreatment Program in effect? ❑ Ycs ❑ No 6. Hasa flow reduction been approved under ISA NCAC 02T .01 14(f)'? [:]Yes ®No - If yes, Provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(11) Daily Design Flow' ° No. of Units Flow Clubhouse 5.5 gal/seat 20 110 GPD Pool Area I I gal/person 70 770 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 880 GPD a See 15A NCAC 02T .0114(b). (d). (c)(I) and (c)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or cast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified (in table ISA NCAC 02'r.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 880 GPD (per ISA NCAC 02T .0114) Y Do not include future flows or previously permitted at locations If permitted flow is zero, indicate why: ❑ Punyp Station or Gravity Scwcr where Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: _ ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): _ FORM: FTA 04-16 Page 2 of 5 VI1. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T.0305 & tvIDC (Gravity Sewers): I. Summarize gravity sewer to be permitted: Size (Inches) Length (feet) Material ➢ Section 11 & Ill of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section Ill contains information related to minimum slopes for gravity sewer(s) `r Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T.0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Pine Forest Amenity 2. Approximate Coordinates (Decimal Degrees): Latitude: 33.9684" Longitude: -] Ot 88' 3. Design flow of the pump station: 0.0009 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 20 gallons per minute at 1600 feet total dynamic head (TDI{) 5. Summarize the force train to be permitted (for this Pump Station): Size (inches) Length (feet) Material 2 150 CTS Tubing, SDR 9 6, Power reliability in accordance with ISA NCAC 02T 0305(h)(I): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(Q): D Required for all pump stations with an average daily now greater than or equal to 15,000 gallons per day 9 Must be permanent to facility Or if the pump station has an average daily now less than 15,000 gallons per day: ❑ Portable power source with manuat activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C)' ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the pot -table power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel tinteframes, shall be provided in the case of a multiple station power outage, FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(Q): I. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ® Yes ❑ No > 15A NCAC 02T.0305(f) contains minimum separations that shall be nreviderl fnr sewer svetems- Setback Parameter* Separation Rc uircd Storm sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches IS inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inclics Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class 1 or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands sec item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Anv building foundation 5 lect Any basement 10 feet Top sloe of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches > 15A NCAC 02T.0305(g) contains alternatives where separations in 021'.0305(f) cannot be achieved. > **Stream classifications can be identified using the Division's NC Surface Water Classifications webpege > If noncompliance with 027-.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Ycs ❑ No ❑ N/A )r Seethe Division's draft separation requirements for situations where separation cannot be meet 'v No variance is required if the alternative design criteria specified is utilized in design and construction > As built documents should reterenee the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .02002 ❑ Yes ❑ No ®N/A Y This would include Trout Buffered Streams per I SA NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or []Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0IQ5(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certificution upplications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance ol'dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" menns "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to sn'eambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ NtA > If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittec or its representative at least once every six -months and inspections documented per ISA NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 page 4 of 5 X. CERTIFICATIONS: I. Docs the submilatest tted system comply with 15A NCAC 02T, the and Force Mains (versionl and theGravity Sewer Minin ® Yes If No, complete and submit the Variance/Alternative Design review. Annrnvalnfn,...e ,.e.t 2. Professional Engineer's Certification: as applicable? ❑ No nest application (VADC 10-14) and supporting documents to, — ..-. . . (Pro essional Engineet's name from Application Item III I J attest that this application for P/Nl- FDRCST /� Mom✓/ %rjj has been reviewed by tile and is accurate, complete and consistent witlf tl'C information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. 1 further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. _..... ........ ... ............. North Carolina Professional Engineer's seal, signature, and date: ".. ,,,,,,,,,'.. AI. r YG CL1N� 3. ...._............. Applicant's Certification per ISA NCAC 02T.0106(b): 1, M PNiv/X P� ZYROK 0F_ CGQii) �'/ attest that this application for (Signature Au(hortry s name & title from Applicatio Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledg . I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments arc not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete, NOTE — In accordance with General Statutes 143-215 6A and 43-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a finenotto exceed Sl0,000 as well as civil penalties up to $25,000 per violation. /-/ Signature: VV/t/v!^2_ Date: FORM: PTA 04-16 Page 5 of 5 ,_,J,,, er i ov IV,a, .. .... 1...!rc�s State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Brunswick County Project Name for which flow is being requested: Pine Forest Amenity Center More than one FTSE nmy be required for a single project if the owner of the WWTP is not responsible for all punip stations along the route of theproposed wastewater flow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: WESTBRUNSWICKWWRF b. WWTP Facility Permit #: WQ 0023693 Ali flows are in MGD c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used R 11/ 0.1321 3.507 0.00088 3.640 60.6% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pf), Avg. Daily Daily Flow, Obligated Available Number) No, MGD MGD Flow, MGD MGD Flow Capacity*** The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Pine Forest Blvd Public FM Downstream Permit Number: WQ0039819 Page 1 of 6 FTSE 10-18 III. Certification Statement: I William L. Pinnix, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Official Signature Date —!:))12 TOlz OF Title of Signing Official Page 2 of 6 FTSF. 10-1 R COUNTY OF BRUNSWICK ENGINEERING SERVICES January 5, 2021 Mr. Tim Clinkscales, P.E. Paramounte Engineering, Inc. 122 Cinema Drive Wilmington, North Carolina 28403 OeJ�gple O`yJL J Re: Pine Forest Amenity Center Duplex Grinder Pump Station Dear Mr. Clinkscales, PO BOX 249 BOLIVIA, NC 28422 BUILDING I (910) 253-2500 Office (910) 253-2704 FAX Our office has reviewed the proposed plans and specifications for the new duplex grinder pump station and has determined that this project will meet Brunswick County's minimum standards and specifications if the project is constructed as designed. Brunswick County has a sufficient treatment capacity to provide sewer service for this project. This letter hereby grants authorization for the plan submittal to the North Carolina Department of Environmental Quality / Division of Water Quality for review and approval. Your signed permit application and FTSE 10-18 is enclosed. Please send a copy of this letter to the State along with Your plans specifications and permit application. Do not hesitate to contact our office if you have any questions. Sincerely, bgkekyn E by Wm. L. Pinnix. P.E. ON C 9 'bl 1®p nswl<kWV+lync pov, Wm. L. Pinnix P E "a IACm Iy, Nonll Calolba', i P O.P.e ch Cowry L. Plneemg OapaN(ehl CN-'Wm L Pinnix, 0E' ._.. 101.OSU19a90500' William L. Pinnix, PE Director of Engineering Services /ba xc: Sherri Phipps North Carolina Department of Environmental Quality Pat McCrory Governor October 7, 2015 William L. Pinnix, Director of Engineering Brunswick County PO Box 249 Bolivia, NC 28422 Subject: Variance Request Approval Permit Number: WQCS00284 New/Existing Commercial & Multifamily Pump Stations with Limited Flow Brunswick County Dear Mr. Pinnix: Donald R. van der Vaart Secretary The Division of Water Resources (Division) has reviewed the submitted variance request, as well as the additional information submitted October 1, 2015. The request involved deviation from the requirements of 15A NCAC 02T.0305 for pump stations with low flows that serves multifamily and commercial facilities within the county's service area with the following conditions: 1) This variance only applies to facilities meeting flow rates less than or equal to 1,680 gallons per day (gpd) 2) Pump Stations shall: a) Meet the pump reliability requirement per 15A NCAC 02T.0305(h)(1), (meet peak flow with largest pump out of service) b) Provide 24-hours' worth of wastewater storage (installed or upgraded) c) Install/maintain alarms per 15A NCAC 02T.0305(h)(1)(F) in an area that is noticeable to the general public or onsite staff d) Install/maintain signage per 15ANCAC 02T.0305(h)(2) 3) in accordance with the provision for alternative design covered under 15A NCCA 02T.0105(n), facilities meeting the above conditions are exempt from: a) Requirement to install a standby power source or pump per 15A NCAC 02T.0305 (h)(1)(B) b) Requirement to install/maintain a telemetry system per 15A NCAC 02T.0305(h)(1)(E) c) Requirement to inspect these facilities every day per 15A NCAC 02T.0305(a)(4) and WQCS00284 (Condition V.2), however still required to Inspect the facility at least once per week Regardless of the variance approval, in the event that the wastewater collection facilities fail to perform satisfactorily, Including the creation of nuisance conditions, the Permittee shall take immediate corrective action, Including those as may be required by this Division, such as the construction of additional or replacement facilities. All other facilities shall be constructed in accordance with all applicable rules and statues including, 15A NCAC 2T; the Division of Water Resources' (Division) Gravity Sewer Minimum Design Criteria adopted February 12,1996 as applicable; and the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable. Approval of the variance request does not constitute approval of the permit. Submission and approval of permit applications are still required in accordance with applicable rules and regulations. 1601 Mall Service Center, Raleigh, Nodh Carolina 27699-1601 Phone: 919-707-86001Internet: www.ncdonr.gov An Equal Opportunity 1 Atfrmalive Action Employer — Made in part by recycled paper Variance Request Approval October 7, 201S If you have any questions, please contact Michael Leggett, P.E. at 919-807-6312 or via email at michael.leggett@ncdenr eov. Sincerely, for Jay Zimmerman, P.G. Director, Division of Water Resources by Deborah Gore, PERCS Supervisor Division of Water Resources, NCDEQ enclosures (all) cc: WilliamL.Pinnix,PE — Director of Engineering Services (Wil Ila m.pInnIxP brunswickcountvncgov) James Murray, Engineering Technician / Plan Reviewer (lames.murrayPbrunswickcountvnc ¢ov) Wilmington Regional Office, Water Quality Section Regional Operations Water Quality Central Files — WQCS00184 PERCS Files (electronic copy) Coversheet Page I of 2 Brunswick County Board of Commissioners ACTION AGENDA ITEM 2014 Utilities - Request for Approval of Grinder Pump Maintenance Policy - (Jerry Pierce, Director of Public Utilities) From: Action Item # Vill. - 3. Jerry Pierce, P.E. Date: 7/2/2014 Issue/Action Requested: Request that the Board of Commissioners approve an amendment to the Grinder Pump Maintenance Policy to allow the county to assume maintenance responsibilities for grinder pump stations that provide sewer service to new and existing multifamily projects and to new and existing commercial properties provided the properties meet the terms of the Grinder Pump Maintenance Policy as amended. Background/Purpose of Request: In 2008, the Brunswick County Board of Commissioners approved a Grinder Pump Maintenance Policy. Under the terms of the policy, the county assumed maintenance responsibility for grinder pump stations that provide sewer service to single-family homes. The North Carolina Department of Environment and Natural Resources (NC DENR) permit for the low pressure sewer system had to be in the county's name prior to the county assuming maintenance responsibility. To cover the cost of maintaining the grinder pump stations. A monthly $5.00 grinder maintenance fee was added to the sewer service charges for all customers who had a grinder pump station covered by the policy. The policy did not include maintenance of grinder pump stations associated with multifamily projects and commercial projects. Some multifamily projects and commercial properties were located in the Calabash and Sunset Beach Special Assessment Districts. As such, the county installed duplex grinder pump stations at those locations and assumed maintenance responsibilities as the NC DENR Permit was in the county's name. The county has recently received a request from a multifamily project in St. James that the county assume maintenance responsibility for their duplex grinder pump stations. The proposed Grinder Pump Maintenance Policy Amendment outlines the requirements and terms by which the county will assume maintenance responsibility for multifamily projects and commercial properties. The major requirements are as follows: 1. For all projects, the NC DENR Permit has to be in the county's name. 2. For all projects, plans and specifications have to be submitted to the Engineering Department for review and approval and all construction must be inspected and approved by the Engineering Department. 3. For multifamily projects, the grinder maintenance fee will be charge per unit and for commercial projects the grinder maintenance fee will be based upon the Residential Equivalent Unit (REU) flow associated with the commercial property's use. 4. For existing multifamily and commercial properties, the existing duplex grinder pump station has to be rehabbed to meet the current Brunswick County standards. 5. The permitted sewer flow for new and existing commercial properties cannot exceed 1,680 gpd. 6. For existing multifamily projects, at least 50% of the owners of the units in the building served by the duplex pump station must sign a petition requesting Brunswick County to assume maintenance responsibility for their duplex grinder pump statlon. For multifamily and commercial projects, the owners would have the option to maintain the duplex grinder pump station themselves. The county would not install the duplex grinder pump station and would maintain the duplex grinder pump station only if requested by the property owner(s) or Property Owners Association (POA). County staff recommends that the Board of Commissioners approve the Grinder Pump Maintenance Policy Amendment to allow county maintenance of duplex grinder pump stations at multifamily projects and commercial projects provided they meet the terms of the policy. Fiscal Impact: Reviewed By Director of Fiscal Operations Approved By County Attorney: http://brunswick.novtisagenda.com/agendaptiblic/CoverSheet. aspx?iteml D=783 &MectitigID=71 7/22/2014 Coversheet Page 2 of 2 Yes Advisory Board Recommendation: Approved by Utility Board June 9, 2014 County Manager's Recommendation: Recommend that the Board of Commissioners approve an amendment to the Grinder Pump Maintenance Policy to allow the county to assume maintenance responsibilities for grinder pump stations that provide sewer service to new and existing multifamily projects and to new and existing commercial properties provided the properties meet the terms of the Grinder Pump Maintenance Policy as amended. ATTACHMENTS Description 0 Utilities - Utility Hoard Droll Minutes 6-9-14 - Attach I 0 Utilities - Existing Grinder Pump Maintenance Policy - Attach 2 0 Utilities - Proposed Amendment I to Grinder Punm Maintenance Policy - Attach 3 http://briinswi ck.iioviisagetida.com/agendaptibl is/CoverShect. aspx?ltemID=783 &MectitigID=71 7/22/2014 Amend the existing Grinder Pump Maintenance Policy to add the following sections: MULTIFAMILY NEW CONSTRUCTION The county will provide maintenance for low pressure duplex grinder pump stations installed at new multifamily projects provided the following criteria are met: 1. The NC DENR Authorization to Construct Permit that includes the installation of the duplex grinder pump stations is issued to Brunswick County, 2. The duplex grinder pump stations are installed in accordance with Brunswick County Standard Specifications and Details. The county staff has inspected and approved the installation of the duplex grinder pump station, control panel, and low pressure force main from the pump station to the county - maintained force main or gravity manhole. 3. A blanket easement or a dedicated easement must be provided for the location of the pump station and force main that allows county crews access to maintain the pump station and force main. 4. A duplex grinder pump station must be installed for each building. If the number of units in the building exceeds eight units, additional duplex grinder pump stations may be required, 5. Any telemetry or standby power capability required to meet NC DENR requirements will be the responsibility of the owner or Property Owners Association (POA). If the units are individually billed for sewer service, a grinder maintenance fee will be added to the bill for sewer service. If the multifamily project receives one sewer bill for the entire project, a grinder maintenance fee equal to the number of units served times the grinder maintenance fee will be added to the bill for sewer service. EXISTING CONSTRUCTION The county will assume maintenance responsibility for low pressure duplex grinder pump stations installed at existing multifamily projects provided the following criteria are met: 1. The NC DENR Authorization to Construct Permit that includes the installation of the duplex grinder pump stations is transferred to Brunswick County. 2. The existing duplex grinder pump stations and control panel are upgraded to meet current Brunswick County Standard Specifications and Details. 3. The county staff has approved the plans for the upgrade of the pump station and panel and approves the final constructed upgrade of the duplex grinder pump station and control panel. 4. The county receives a petition signed by a majority of the owners of the units in the buildings served by the grinder pump station requesting that the county assume maintenance of the grinder pump station or a resolution of the POA if allowed by the POA covenants. S. A blanket easement or a dedicated easement must be provided for the location of the pump station and force main that allows county crews access to maintain the pump station and force main. 6. Any telemetry or standby power capability required to meet NC DENR requirements will be the responsibility of the owner or POA. If the units are individually billed for sewer service, a grinder maintenance fee will be added to the bill for sewer service. If the multifamily project receives one sewer bill for the entire project, a grinder maintenance fee equal to the number of units served times the grinder maintenance fee will be added to the bill for sewer service. COMMERCIAL PROPERTIES NEW The county will provide maintenance responsibility for duplex grinder pump stations installed at new commercial projects provided the following criteria are met: 1. The NC DENR Authorization to Construct Permit that Includes the installation of the duplex grinder pump stations is issued to Brunswick County. 2. The projected flow from the project Is less than 1,680 gallons per day as determined by the NC DENR Wastewater Design Flow Rate Regulation. 3. The duplex grinder pump stations are installed in accordance with Brunswick County Standard Specifications and Details. 4. The county staff has inspected and approved the installation of the duplex grinder pump station, control panel, and force main from the pump station to the county -maintained force main or gravity manhole. S. A blanket easement or a dedicated easement must be provided for the location of the pump station and force main that allows county crews access to maintain the pump station and force main. 6. Any telemetry or standby power capability required to meet NC DENR requirements will be the responsibility of the owner. The grinder maintenance fee based upon the REU for the use will be added to the sewer service bill for the commercial business, EXISTING The county will assume maintenance responsibility for duplex grinder pump stations installed at existing commercial projects provided the following criteria are met: 1. The NC DENR Authorization to Construct Permit that includes the installation of the duplex grinder pump stations is transferred to Brunswick County, 2. The projected flow from the project is less than 1,680 gallons per day as determined by the NC DENR Wastewater Design Flow Rate Regulation. 3. The existing duplex grinder pump stations and control panel are upgraded to meet current Brunswick County Standard Specifications and Details. 4. The county staff has approved the plans for the upgrade of the pump station and panel and approves the final constructed upgrade of the duplex grinder pump station and control panel. 5. A blanket easement or a dedicated easement must be provided for the location of the pump station and force main that allows county crews access to maintain the pump station and force main. 6, Any telemetry or standby power capability required to meet NC DENR requirements will be the responsibility of the owner. The grinder maintenance fee based upon the REU for the use will be added to the sewer service bill for the commercial business intivea Imap Legena Wrfte a description for your map. Mdway Trading Post Lei k Aw i i . . e SOUfhp — aSE� N Google Earth 2000 ma _ 2000 fi