HomeMy WebLinkAboutWQ0019188_Compliance Evaluation Inspection_20210304ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director William and Katherine Holbert 118 Goldfinch Ln Apex, NC 27523 Dear Mr. and Mrs. Holbert, NORTH CAROLINA Environmental Quality March 4, 2021 Subject: Permit No. WQ0019188 William and Katherine Holbert SFR Surface Irrigation System Chatham County On March 2, 2021, staff of the NC Division of Water Resources (DWR), inspected the subject single-family residence wastewater treatment and surface irrigation system. The purpose of the visit was to conduct a compliance inspection. I wish to thank Mr. Holbert for his assistance during the inspection. The following comments are highlighted as a result of the inspection (please refer also to the attached inspection report): 1. The septic tank was pumped on February 2, 2021. 2. All pumps and alarms were operational. 3. The UV disinfection unit was operating as designed. 4. The entire drip field was properly fenced and well maintained. If you have any questions concerning this inspection or the necessary corrective measures, you may contact Jane Bernard via email at jane.bernard@ncdenr.gov or at (919) 791-4233. Attachments Inspection Report cc: laser fiche Sincerely, q"°15 cii\ALIA.e7 Jane R. Bernard Environmental Specialist, Division of Water Resources, Water Quality Regional Operations Section North Carolina Department of Environmental Quality I Division of Water Resources Rakigh Regional Office 13800 Barrett Drive I Raleigh. North Carolina 27609 919.791.4200 Compliance Inspection Report Permit, W00019188 Effective: 06/22/16 Expiration: 05/31/21 Owner : William G Holbert SOC: Effective: Expiration: Facility: 118 Gold Finch Ln. SFR County: Chatham Region: Raleigh Contact Person: William G Holbert Title: Phone: Directions to Facility: US 64 West from Cary/Apex. Right on Hwy 751 for 3.5 miles. Right on Lewter Sr.op Rd. for 1.1 miles. Right on Thompson Rd. for 1 mile. Lefton Gold Finch Lane, address is 118. System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 03/02/2021 Entry Time 09:45AM Exit Time: 10:30AM Primary Inspector: Jane Berna�� Secondary Inspector(s): Phone: 919-791-4200 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Single -Family Residence Wastewater Irrigation Facility Status: Compliant ❑ Not Compliant Question Areas: ▪ Miscellaneous Questions O Sand Filter/Treatment Pods 1.1 Drip or Irrigation (See attachment summary) Permit Status Disinfection UV II 1.1 Septic Tank Pump Tank Page 1 of 4 Permit: W00019188 Owner - Facility: William G Holbert Inspection Date: 03/02/2021 Inspection Type :Compliance Evaluation Reason for Visit: Routine Inspection Summary: The following comments are highlighted as a result of the inspection: 1. The septic tank was pumped on February 2, 2021. 2. Ali pumps and alarms were operational. 3. The UV d.sinfection unit was operating as designed. 4. The entire drip Feld was properly fenced and well maintained. Page 2 of 4 Permit: WQ0019188 Owner - Facility: William G Holbert Inspection Date: 03/02/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Permit Status # Is the current resident in the home the Permittee? # If not, does the resident rent from the Permittee? Change of Ownership form needed? (Ma;I the form with the inspection letter) # Is there an inspection and maintenance agreement with a contractor? If YES, who is the contractor (include contact info)? Comment: Septic Tank *** The septic tank and filters should be checked annually and pumped/cleaned as needed. *** Is all wastewater from the home connected to the septic tank? # Does the permittee/resident know where the septic tank is located? Has the septic tank been pumped in the last 5 years? If YES, describe if known and proof (include date pumped): Reciept 2/18/21 # Does the septic tank have an EFFLUENT FILTER or SANITARY T? If FILTER, when was the filter cleaned and by who? Comment: Sand Filter!Treatrnent Pods **' Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be removed manually. *** # Is system something other than a sand filter? # If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.) # Does the permittee know where the sandfilter is located? Does the sandfilter require maintenance? If maintenace is required, explain: Comment: Disinfection UV ** UV unit shall be checked weekly. Lamps/sleeves should be cleaned/replaced as needed to ensure proper disinfection. *** Is UV working? • ❑ ❑ ❑ Has the UV Unit been serviced and bulbs cleaned? • ❑ ❑ ❑ # Who completes the weekly check for the UV? ( Non -Discharge) Permittee Comment: Yes No NA NE . 000 ❑ ❑ ❑ ❑ ❑ ❑ O 0E10 Yes No NA NE ▪ ❑❑❑ ■ ❑❑❑ 1110012 • ❑ ❑ ❑ 2/18/21 Permittee Yes No NA NE ❑ ❑ ❑ • ❑ ❑ ❑ ❑ ❑■❑ Yes No NA NE Pump Tank Yes No NA NE Ail pump and alarm sytems shall be inspected monthly. (Non -Discharge) *** Page 3 of 4 Permit: W00019188 Owner - Facility:William G Holbert Inspection Date: 030212021 Inspection Type :Compliance Evaluation Reason for Visit: Routine Is the pump working? Is the audible and visual high water alarm operational? # Does tl-e permittee know how to check the pump & high water alarm? # Last functtional test; Comment: Drip or Irrigation "' Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating as designed. '"' # Type of system (DRIP or IRRIGATION): # If IRRIGATION, number of sprinkler heads: Are buffers and setbacks adequate? is the site free of ponding and runoff? Does the application equipment appear to be working properly? Is there a minimum two wire fence surrounding the entire irrigation area? Comment: i❑❑❑ • ❑❑❑ • ❑❑❑ 2/18/21 Yes No NA NE Drip • ❑❑❑ MO ▪ ❑ ❑ ❑ • ❑ ❑ ❑ Page 4 of 4