Loading...
HomeMy WebLinkAboutNCG120085_Inspection_20210303ROY COOPER Governor MICHAEL S. REGAN Secretary BRIAN WRENN Director March 3, 2021 Union County C&D Landfill Attention: Chris Medlin 2125 Austin Chaney Road Wingate, North Carolina 28174 NORTH CAROLINA Environmental Quality Subject: Compliance Evaluation Inspection Union County C&D Landfill NPDES Certificate of Coverage — NCG120085 Union County, North Carolina Dear Mr. Medlin, Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection we conducted at the Union County C&D Landfill on February 24, 2021. Please note that in the stormwater inspection report summary we ask that you conduct monthly analytical monitoring and prepare a case for monitoring relief. The report should be self-explanatory; however, should you have any questions, please do not hesitate to contact me at (704) 663-1699 or by E-mail at james.moore@ncdenr.gov. Sincerely, es Moore Assistant Regional Engineer Enclosure c: Laserfiche Q.1�1� NORTH CAROUNA omwMent m Fnwraunenm auw� North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115 704.663.1699 Compliance Inspection Report Permit: NCG120085 Effective: 11/01/18 Expiration: 05/31/21 Owner: Union County SOC: Effective: Expiration: Facility: Union County Solid Waste Mgmt. Facility (C & [ County: Union 2125 Austin Chaney Rd Region: Mooresville Wingate NC 28174 Contact Person: Chris Medlin Title: Phone: 704-989-1949 Directions to Facility: System Classifications: SWNC, Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 02/24/2021 Primary Inspector: Lily C Kay Secondary Inspector(s): Entry Time 01:30PM Reason for Inspection: Routine Permit Inspection Type: Landfill Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Certification: Phone: Exit Time: 03:OOPM Phone: 704-663-1699 Inspection Type: Compliance Evaluation Page 1 of 3 Permit: NCG120085 Owner - Facility: Union County Inspection Date: 02/24/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: The facility appeared to be well maintained and operated with the proper documentation of monitoring. Tier II response with monthly monitoring is required along with documentation of other sources of fecal coliform bacteria before monitoring relief can be considered. If you have any questions, please contact me at Lily.Kay@ncdenr.gov or by phone at (704) 235-2137. Page 2 of 3 Permit: NCG120085 Owner - Facility: Union County Inspection Date: 02/24/2021 Inspection Type : Compliance Evaluation Reason for Visit: Routine Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 El Comment: The facility has conducted and recorded semiannual qualitative monitoring Analytical Monitorinq Yes No NA NE Has the facility conducted its Analytical monitoring? ■ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? 0 El 0 ❑ Comment: The facility has conducted and recorded analytical monitoring but the outlets are consistently over the benchmark limitations for fecal coliform bacteria. There were several si ns of wildlife at the facility and a farm uses chicken manure for fertilizer on fields above the site Evidence of these occurrences need to be documented to present for a monitoring relief requeest The facility also needs to conduct Tier II monitoring and prepare the proper Tier responses TSS also needs to be reviewed to determine if a Tier response is necessary for consequetive exceedances of the 100 mg/1 benchmark limitation Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? N El ❑ El # Were all outfalls observed during the inspection? ■ El D ❑ # If the facility has representative outfall status, is it properly documented by the Division? El ❑ 0 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? El❑ 0 ❑ Comment: Sediment basins used for the transfer station construction project are being utilized for stormwater. One of the front sediment basins needs to be cleaned and it is recommended to install a forebaV for sediment accumulation and easy clean out Some outlets could be improvec with minor BMPs like street sweeping and installing silt sacks in yard inlets and rock check dams in swales leading to outlets. Page 3 of 3