Loading...
HomeMy WebLinkAboutNCG030617_2021 DMR_20210226NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0617 Person Collecting Samples: Michael Kilpatrick (Pace Analytical) Facility Name: CORMETECH, Inc. Laboratory Name: Pace Analytical Facility County: Mecklenburg Laboratory Cert. No.: 329 Discharge during this period: ✓❑ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions this sample period for any benchmark exceedances? ❑ Yes ❑✓ No If so, which Tier (I, II, or III)? SEE NOTES A copy of this DMR has been uploaded electronically via https://edocs.deg.nc.gov/Forms/SW-DMR ❑✓ Yes ❑ No Date Uploaded: 02/26/2021 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 001 Outfall 002 Outfall 003 Outfall Outfall Code N/A Receiving Stream Class Class C Class C Class C N/A Date Sample CollectedMM/DD/YYYY 02/11/2021 02/11/2021 02/11/2021 46529 24-Hour Rainfall in inches 0.56 0.56 0.56 C0530 TSS in mg/L (100 or 50*) 14 NO Flow 48 00400 pH in standard units (6.0-9.0) 6.4 No Flow 6.2 01119 Copper, total recoverable in mg/L <0.010 No Flow 0.032 (0.010) 01051 Lead, total recoverable in mg/ L <0.010 No Flow <0.010 (0.075) 01094 Zinc, total recoverable in mg/ L 0.029 No Flow 0.075 (0.126) 78141 Total Toxic Organics (TTO) in mg/L(!', Not Applicable Not Applicable Not Applicable (if required) 00552 Non -Polar Oil & Grease in mg/L i `=ti•) <5.0 No Flow <5.0 Additional parameters for outfalls in drainage areas that use >55 gallons per month of new hydraulic oil on average NCO Estimated New Motor/Hydraulic Oil Not Applicable Not Applicable Not Applicable Usage in gal/month Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of . All other water classifications have a benchmark of 100 mg/L Notes (optional): See letter from Zahid Khan attached. (Relief from Monthly Monitoring for Copper and Zinc) "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Permittee or Delegbted Authorized Individual Email Address C =�LC�Le_i'- CL —Fn L�Oc�l Date Phone Number Total Toxic Organics Certification: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no leak, spill, or dumping of concentrated toxic organics into the stormwater or onto areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the Solvent Management Plan included in the Stormwater Pollution Prevention Plan." Signature of Permittee or DelegAed Authorized Individual Email Address �� i 1 � i' � LC1r- fY,)ff+([ i).. CDm aT1 aua Date Phone Number 1-6 } i Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY October 5, 2016 CoaLogix SCR -Tech Attention: Mr. Brad Cummock, Owner/Contact Person 11707 Steele Creek Road Charlotte, North Carolina 28273 Dear Mr. Cummock: PAT MCCRORY Governor DONALD R. VAN DER VAART Secrctaty TRACY DAVIS Director Subject: Relief from Monthly Monitoring NPDES Stormwater Permit NCG030000 Certificate of Coverage # NCG030617 11707 Steele Creek Road, Mecklenburg County, North Carolina We received a request for relief from monthly monitoring regarding levels of zinc and copper in stormwater from this site exceeding the benchmark limits of the NCG030000 general permit. The facility was inspected on September 28, 2016 by staff of this office accompanied by Ms. Lanette Plyler. Based on our inspection and the investigation of potential sources are not attributed by CoaLogix SCR -Tech, and Division is granting regulatory relief from the Tier Two response for copper and zinc benchmark exceedances. Upon receipt of this letter, the subject facility may continue the semi-annual analytical monitoring schedule as specified in the general permit for the remainder of the current permit term. Your current permit is set to expire on October 31, 2017. Please note that this monitoring relief applies only to zinc and copper. Any benchmark limit exceedance of other parameters required by the permit will trigger the tiered response actions as described within the general permit. You must notify this office, in writing, within 5 business days if you become aware of any other significant source of copper or zinc at your facility that has potential to affect stormwater from the facility. The relief granted in this letter is contingent upon the current practices at this facility. If any practices should deviate from current activities and create significant stormwater exposure risk, this office reserves the right to withdraw this decision and reinstate the permit specified tiered response that may be warranted by any new circumstances. State of North Carolina I Environmental Quality I Energy, Mineral and Land Resources Mooresville Regional Office 1 610 East Center Ave Ste 301 1 Mooresville, NC 28115 704 663 1699 T Relief from Monthly Monitoring CoaLogix SCR -Tech October 5, 2016 Page 2 of 2 Please retain and append this letter to your Stormwater Pollution Prevention Plan (SPPP) or permit. If you have any questions, comments, or concerns please contact our office at 704-663-1699. Sincerely, s-1 /�-' Zahid S. Khan, CPM, CPESC, CPSWQ Regional Engineer Land Quality Section Enclosure: Inspection Report cc: Ms. Lanette Plyler, 11707 Steele Creek Road, Charlotte, NC 28273 Mr. Bradley Bennett, Stormwater Permitting Program, Certificate of Coverage NCG Compliance inspection Report Permit: NCG030617 Effective: 12/12/12 Expiration: 10/31/17 Owner: Brad Cummock SOC: Effective: Expiration: Facility: CoaLogix SCR -Tech County: Mecklenburg 11707 Steele Creek Rd Region: Mooresville Charlotte NC 28273 Contact Person: Brad Cummock Title: Phone: 704-414-4614 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 09/28/2016 Primary Inspector: Holliday Keen Secondary Inspector(s): Certification: Phone: EntryTime: 11:OOAM Exit Time: 12:OOPM Phone: Zahid S Khan Phone : Reason for Inspection: Other Inspection Type: Technical Assistance Permit Inspection Type: Metal Fabrication Stormwater Discharge COC Facility Status: Compliant Not Compliant Question Areas: ® Storm Water (See attachment summary) Page: 1 Permit: NCG030617 Owner - Facility: Brad Cummock Inspection Date: 09/28/2016 Inspection Type: Technical Assistance Reason for Visit: Other Inspection Summary: This inspection was conducted per request for technical assistance from Lanette Plyler. In November of 2015, analytical monitoring resulted in copper and zinc levels exceeding the benchmark limits specified in the general permit for NCG030000. These exceedances put Coalogix in Tier Two monitoring and monthly analytical monitoring began in December of 2015. After investigation, Coalogix was unable to locate the source causing the stormwater to exceed the benchmark limits. During our inspection, we found that the site was well maintained and we were unable to locate the source of the copper and zinc causing exceedances in the analytical monitoring. Because site conditions reflect compliance with all stipulations of general permit NCG030000, this site may return to Tier One montioring requirements. Page: 2 Permit: NCG030617 Owner - Facility: Brad Cummock Inspection Date: 09/28/2016 Inspection Type : Technical Assistance Reason for Visit: Other Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ■ ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ N ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 ❑ ❑ ❑ Comment: Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? E ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? M ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑ ❑ ❑ # Is the Plan reviewed and updated annually? R ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? E ❑ ❑ ❑ Comment Page: 3