Loading...
HomeMy WebLinkAbout20120682 Ver 1_CAMA Permit Application_20120712July 10 2012 MEMORANDUM TO FROM SUBJECT Applicant Project Location Proposed Project Karen Higgins Webscape Unit Supervisor Division of Water Quality Raleigh Doug Huggett Major Permits Processing Coordinator CAMA Permit Application Review NC Aquarium on Roanoke Island 374 Airport Road Manteo Dare County 201 2068 2 Resources Dee Freeman Secretary L 2 2012 1 DENR e8 "8 �ATgR nwA, !4111y Pier gazebo educational platform, kayak launch walkways storage Please indicate below your agency's position or viewpoint on the proposed project and return this form by 07/31/12 to 400 Commerce Avenue, Morehead City, NC 28557 If you have any questions regarding the proposed project please contact Kelly Russell at (252) 264 3901 When appropriate in depth comments with supporting data are requested REPLY This agency has no objection to the project as proposed This agency has no comment on the proposed project This agency approves of the project only if the recommended changes are incorporated See attached This agency objects to the project for reasons described in the attached comments SIGNED DATE 1367 US 17 South Elizabeth City NC 27909 Phone 252 264 3901 1 FAX 252 264 3723 Internet www nccoastalmanagement net NorthCarollna An Equal Opportunity 1 Affirmative Action Employer AaAmallb, 1 2 3 4 DIVISION OF COASTAL MANAGEMENT FIELD INVESTIGATION REPORT APPLICANT'S NAME NC Aquarium on Roanoke Island LOCATION OF PROJECT SITE NC Aquarium Airport Rd Manteo Dare County on the Croatan Sound Photo Index — 2006 181 -7272 F 7) 1984 142 1575 (0 20) State Plane Coordinates X 2975800 INVESTIGATION TYPE CAMA 2000 181 2169 (R 19) 1989 54 -4 (F 10) Y 804500 INVESTIGATIVE PROCEDURE Dates of Site Visit — 6/26/2012 Was Applicant Present no 5 PROCESSING PROCEDURE Application Received Complete - 6/22/2012 Office - Elizabeth City 6 SITE DESCRIPTION (A) Local Land Use Plan - Dare Land Classification From LUP conservation (B) AEC(s) Involved Estuarine Waters Public Trust Estuarine Shoreline (C) Water Dependent yes (D) Intended Use public (E) Wastewater Treatment Existing — LPP individual system Planned -none (F) Type of Structures Existing — aquarium and associated structures and parking area rip rap Planned - public access pier storage building (G) Estimated Annual Rate of Erosion n/a Source — n/a 7 HABITAT DESCRIPTION [AREA] DREDGED FILLED Shaded (A) Estuarine Waters Public Trust Area (EW PTA) 625 sq ft (temporary impacts) 4676 sq ft (B) Estuarine Shoreline (ES) 2450 sq ft (D) Total Area Disturbed 7751 sq ft (E) Primary Nursery Area no (F) Water Classification SA Open no 8 PROJECT SUMMARY The NC Aquarium proposes to construct a 220 ft by 8 ft pier with 3 268 sq ft of platform area The applicant also proposes to construct a 450 sq ft storage building and approximately 2000 sq ft of concrete walkways more than 30 ft away from NWL Field Investigation Report NC Aquarium Page 2 Project Setting The North Carolina Aquarium on Roanoke Island is located on approximately 25 acres of land between Airport Road and the Croatan Sound on the northern end of the Island The property is approximately 10 ft above normal water level (NWL) and is vegetated mostly with typical lawn grasses common landscaping plants and pine trees The Aquarium site consists of the Aquarium building several support warehouses and a paved parking area The tract has approximately 1298 ft of shoreline that is stabilized with rip rap There are no known areas of archaeological significance associated with the project site No submerged aquatic vegetation was observed in the project area Water depths in the Croatan Sound in the area range from -2 ft nearshore to -3 8 ft approximately 180 ft offshore In the area of this project the Croatan Sound is classified as SA by the NC Division of Environmental Management and is closed to shellfish harvesting Development Proposal The North Carolina Aquarium proposes to construct a 220 ft by 8 ft pier to improve public access and to be used for educational programs fishing and other specials events The pier would consist of a 44 ft by 8 ft sectional over land and over the existing rip rapped shoreline leading to a 176 ft by 8 ft section over water The pier would have six platform areas totaling 3 268 sq ft The platform areas consist of a 3 ft by 60 ft kayak launch a 17 ft by 11 ft floating dock a 25 ft by 33 ft educational platform a 37 ft by 16 ft and 26 ft by 16 ft platform at the end of the pier two T platforms both of which are 28 ft by 8 ft and 11 ft by 11 ft and three bump out sections of platform area each of which are 4 ft by 22 ft In order to construct the pier an approximately 25 ft area of rip rap will have to be temporarily removed along the shoreline to allow for the pilings to be driven The rip rap will be mechanically removed and stored 30 ft away from NWL until the pilings are driven and then will be put back in place The proposal also includes the construction of a 450 sq ft storage building and an 8 ft wide concrete walkway leading to the storage building pier and back to the existing brass sea turtle statue all of which total approximately 2000 sq ft and are more than 30 ft away from NWL The site plan also references a 1792 sq ft turtle exhibit building and 950 sq ft of paved parking areas and walkways that are proposed in a 2 "d phase of the construction and are all well outside of any areas of environmental concern Anticipated Impacts The proposed project will shade 4 676 sq ft of Public Trust Area (PTA) and Estuarine Water (EW) Areas of Environmental Concern (AEC) The project will also temporarily disturb approximately 625 sq ft of shallow bottom PTA and EW AEC due to the removal and then replacement of the rip rap along the shoreline The upland development will fill approximately 2 450 sq ft of Estuarine Shoreline (ES) AEC Temporary water turbidity will occur in the project location Submitted by Kelly Russell Date 7/6/2012 MAJOR PERMIT FEE MATRIX Applicant N c AFL AR f K 4'1 R a A N o KC T s 6A iv-Z> Selection Development Type Fee DCM % DWQ % (14300 1601 435100093 1625 6253) (24300 1602 435100095 2341) I Private non commercial development that does not $250 100%($250) 0%($0) involve the filling or excavation of any wetlands or open water areas II Public or commercial development that does not $400 100%($400) 0%($0) involve the filling or excavation of any wetlands or open water areas III For development that involves the filling and /or excavation of up to 1 acre of wetlands and /or open water areas determine if A B C or D below applies III(A) Private non commercial development if $250 100%($250) 0%($0) General Water Quality Certification No 3490 (See attached ) can be applied III(B) Public or commercial development if General $400 100%($400) 0%($0) Water Quality Certification No 3490 (See attached) can be applied III(C) If General Water Quality Certification No $400 60%($240) 40%($160) 3490 (see attached) could be applied but DCM staff determined that additional review and written DWQ concurrence is needed because of concerns related to water quality or aquatic life III(D) If General Water ❑ Quality Certification No $400 60%($240) 40%($160) 3490 (see attached) cannot be applied IV For development that El involves the filling and /or $475 60%($285) 40%($190) excavation of more than one acre of wetlands and /or o en water areas North Carolina Aquarium on Roanoke Island Pier & Gazebo Addition Narrative SCO Project # 10- 08739 -01 A June 2012 The North Carolina Aquarium on Roanoke Island intends to construct a 220 foot long pier with a Gazebo lower educational platform fishing areas and kayak launch in the Croatan Sound west of the existing Aquarium facility The pier will be used for interpretation educational programs fishing special events and other programs administered by the NC Aquarium staff and others The project will also include a small storage building to contain items used for educational programs including kayaks dip nets PFD s paddles and other program related materials The project will include removal and replacement of some existing armor stone in order to install wooden pilings for the pier foundation This armor stone will be carefully removed using mechanical equipment and stored on the upland area near the new storage budding until it can be replaced upon completion of the piling installation These are large (550 #) clean stones with little to no fine materials expected to be excavated The pier will have interpretive stations benches and a gazebo It will also have two branching fishing areas with ADA compliant benches at each end The pier will have a lower- platform to be -used for educational programs and ADA compliant kayak and - water access This will include a small floating dock and a kayak launch Listed below are the sizes of the various platforms • Gazebo platform • Lower platform • Floating dock • Fishing tees • Benches • Total Platform Area 1004 s f 825 s f 187sf 476sf x(2) =952sf 40sf x(3) =120sf 3 088 sf The pier will be open to the general public during the Aquariums hours of operation and it will also be utilized for weddings and special events held after normal hours of operation The pier and lower platform is not intended to be used for mooring by the Land Planning - Engineenng - Environmental - Construction Management P O Box 3989 115 W Saint Clair St Kill Devil Hills North Carolina 27948 North Carolina License No C 1027 Phone 252 441 2113 www AlbemarleAssoaates corn Fax 252 4410965 North Carolina Aquarium on Roanoke Island Pier & Gazebo Addition Narrative SCO Project # 10-0739 -01A June 2012 Page 2 of 2 general public but will accommodate Aquarium organized kayak tours of the Sound and surrounding waters The pier will be constructed of wood piles girders Joists and decking The pier will have power water electrical services and WIFI capability The kayak launch is a narrow wooden pile supported chute which will assist in getting kayaks from the top of the bank to the water It is not intended for pedestrian use and kayaks will be raised and lowered to the water using ropes This chute is intended to protect the kayaks from damage while placing them into and out of the water and to avoid having to use the pier itself for kayak transfers The water ward end will terminate at the normal water level Stormwater management for the storage shed and the onshore improvements will utilize the existing stormwater management basin permeable pavers and infiltration areas along the proposed pathway o- � �6 Q ICE NFLI APPLICATIONfor Major Development Permit Cow, (last revised 12127106) E L I L � B F H t i North Carolina DIVISION OF COASTAL MANAGEMENT 1 Primary Applicant Landowner Information Business Name Project Name (if applicable) North Carolina Aquarium On Roanoke Island NC Aquanum on Roanoke Island Pier Albemarle & Associates Ltd Applicant 1 First Name MI Last Name Agentl Contractor 1 First Name Maylon L White Director Applicant 2 First Name MI Last Name DeLucia PE If additional applicants please attach an additional page(s) with names listed Agent/ Contractor 2 First Name Mailing Address Last Name PO Box 967 PO Box Crry State 967 Manteo NC ZIP Country Phone No NC FAX No 27954 0967 Dare 252 473 3494 ext 252 473 1980 Street Address (if different from above) City State ZIP 374 Airport Rd Manteo NC 27954 Email 252 441 0965 White Maylon L [ maylon white @ncaquanums com] Street Address (if different from above) 2 AgentContractor Information Business Name Albemarle & Associates Ltd Agentl Contractor 1 First Name MI Last Name John M DeLucia PE Agent/ Contractor 2 First Name MI Last Name Mailing Address PO Box State PO Box 3989 EKdI vil Hills NC ZIP ZIP Phone No 1 Phone No 2 252 441 2113 ext ext FAX No Contractor # 252 441 0965 Street Address (if different from above) City State ZIP 115 West St Clair Kill Devil Hills NC 27948 Email )ohnd @albemadeassociates corn <Form continues on back> Form DCM MP 1 (Page2Lof1) YO- 11ATION f r Major Development Pern it 3 Project Location a Total length of shoreline on the tract (ft) b Size of entire tract (sq It ) 1298 730718 County (can be multiple) Street Address COATI Dare 374 Airport Road L 4Z§ UY Subdivision Name City State Zip buildings storage buildings and equipment which supports the Aquarium Manteo NC 27954 Phone No Lot No (s) (if many attach additional page with list) 252 —473 3494 ext j Is the proposed project consistent with the applicable zoning? a In which NC river basin is the project located? b Name of body of water nearest to proposed project Pasquotank Croatan Sound c Is the water body identified in (b) above natural or manmade? d Name the closest major water body to the proposed project site ®Natural []Manmade ❑Unknown Croatan Sound 1 e Is proposed work within city limits or planning jurisdiction? f If applicable list the planning jurisdiction or city limit the proposed ®Yes []No work falls within Dare 4 Site Descnption a Total length of shoreline on the tract (ft) b Size of entire tract (sq It ) 1298 730718 c Size of individual lot(s) d Approximate elevation of tract above NHW (normal high water) or NWL (normal water level) (If many lot sizes please attach additional page with a list) 10 ❑NHW or ®NWL e Vegetation on tract Landscaping and Native Flora f Man made features and uses now on tract North Carolina Aquarium on Roanoke Island consists of the Aquarium building parking lots outdoor exhibits support buildings storage buildings and equipment which supports the Aquarium g Identify and describe the existing land uses adjacent to the proposed project site N Residential S Dare County Airport E Dare County (Undeveloped) W Croatan Sound h How does local government zone the tract? j Is the proposed project consistent with the applicable zoning? 11 (Attach zoning compliance certificate jf applicable) ®Yes []No []NA I Is the proposed activity part of an urban waterfront redevelopment proposal? ❑Yes ®No k Hasa professional archaeological assessment been done for the tract? If yes attach a copy ❑Yes ®No ❑NA If yes by whom? I is the proposed project located in a National Registered Historic District or does d involve a ❑Yes ®No ❑NA National Register listed or eligible property? <Form continues on next page> Form DCM MP 1 (Pase oft) �- r ,� P ATION f M Major Developmen Perrr it m (i) Are there wetlands on the site? IY_es._ ®No (o) Are there coastal wetlands on the site? YjRj� 70NO '-'IrilT EI I'f r' H CITY (in) If yes to either (i) or (u) above has a delineation been conducted? ❑Yes []No (Attach documentation if available) n Describe existing wastewater treatment facilities Secondary Treatment ninth LPP Drainfield Subsurface Disposal o Describe existing drinking water supply source County Water System p Describe existing storm water management or treatment systems Existing BMP s and State SWpermd SW7971022 5 Activities and Impacts a Will the project be for commercial public or private use? ❑Commercial ®PubliclGovemment ❑Pnvate /Community b Give a brief description of purpose use and daily operations of the project when complete To be used for eductional passive recreatioanal active recreatioanal and specad events Pier will be multifunctional but will not be used for docking or mooring boats other than educational program related kayaks and small boats Pier will be used for fishing and crabbing c Describe the proposed construction methodology types of construction equipment to be used during construction the number of each type of equipment and where it is to be stored Driven wood piles with heavy wood frame constrcution fo the pier decking and gazebo d List all development activities you propose Clearing grading concrete paving underground utilities pier construction e Are the proposed activities maintenance of an existing project new work or both? New f What is the approximate total disturbed land area resulting from the proposed project? 3000 ®Sq Ft or ❑Acres g Will the proposed project encroach on any public easement public accessway or other area ❑Yes ®No ❑NA that the public has established use of? h Describe location and type of existing and proposed discharges to waters of the state None i Will wastewater or stormwater be discharged into a wetland? ❑Yes ®No []NA If yes will this discharged water be of the same salinity as the receiving water? ❑Yes []No []NA j Is there any mitigation proposed? ❑Yes ®No ❑NA If yes attach a mitigation proposal <Form continues on back> Form DCM MP 1 (Pagevofv) -- — - LICA ION for Mayor Deve pme it Permit 6 Additional Information In addition to this completed application form (MP 1) the following items below if applicz ble must _ b r i ► the appin ation package to be complete Items (a) — (t) are always applicable to any major development instruction booklet on how to properly prepare the required items below a A project narrative b An accurate dated work plat (including plan view and cross - sectional drawings) drawn to scale Please give the present status of the proposed project is any portion already complete? if previously authorized work clearly indicate on maps plats drawings to distinguish between work completed and proposed c A site or location map that is sufficiently detailed to guide agency personnel unfamiliar with the area to the site d A copy of the deed (with state application only) or other instrument under which the applicant claims title to the affected properties e The appropriate application fee Check or money order made payable to DENR f A list of the names and complete addresses of the adjacent waterfront (riparian) landowners and signed return receipts as proof that such owners have received a copy of the application and plats by certified mad Such landowners must be advised that they have 30 days in which to submit comments on the proposed project to the Division of Coastal Management Name Dare County Phone No 252 475 5000 Address PO Box 1000 Manteo NC 27954 Name Larry & Maxine Thonasson Phone No 252 473 2234 Address 359 Airport Rd Manteo NC 27954 Name Phone No Address g A list of previous state or federal permits issued for work on the project tract Include permit numbers permittee and issuing dates SW7971022 Stormwater DWQ h Signed consultant or agent authorization form d applicable i Wetland delineation if necessary I A signed AEC hazard notice for projects in oceanfront and inlet areas (Must be signed by property owner) k A statement of compliance with the N C Environmental Policy Act (N C G S 113A1 10) if necessary If the project involves expenditure of public funds or use of public lands attach a statement documenting compliance with the North Carolina Environmental Policy Act 7 Certification and Permission to Enter on Land I understand that any permit issued in response to this application will allow-only the development-described in the application The project will be subject to the conditions and restrictions contained in the permit I certify that I am authorized to grant and do in fact grant permission to representatives of state and federal review agencies to enter on the aforementioned lands in connection with evaluating information related to this permit application and follow up monitoring of the project I further certify that the information provided in this application is truthful to the best of my knowledge Date 30 ZU i - Print Name 1(119YCOA) Z- 76 Signature Please indicate application attachments pertaining to your proposed project ❑DCM MP 2 Excavation and Fill Information ❑DCM MP 5 Bridges and Culverts ®DCM MP 3 Upland Development ®DCM MP-4 Structures Information Form DCM MP -3 I , UPLAND DEVELOPMENT �-- (Construction and/or land disturbing activities) Attach this form to Joint Application for CAMA Mayor Permit Form DCM MP 1 Be sure to complete all other sections of the Joint Application that relate to this proposed project Please include all supplemental information GENERAL UPLAND DEVELOPMENT a Type and number of buildings facilities units or structures proposed 450 sf Storage Burlidng to be used to store teaching aids for programs on the new pier c Density (give the number of residential units and the units per acre) N/A e If the proposed project will disturb more than one acre of land the Division of Land Resources must receive an erosion and sedimentation control plan at least 30 days before land- disturbing activity begins (i) If applicable has a sedimentation and erosion control plan been submitted to the Division of Land Resources? ❑Yes []No ®NA (u) If yes list the date submitted g Give the percentage of the tract within the coastal shoreline AEC to be covered by impervious and /or built upon surfaces such as pavement budding rooftops or to be used for vehicular driveways or parking 832% i Give the percentage of the entire tract to be covered by impervious and /or built upon surfaces such as pavement budding rooftops - -- -or to be used for vehicular dnveways or parking -- -- 34 2% I Describe proposed method of sewage disposal Exisrtng Secondary Treatment system with LPP Subsurface Disposal I Describe location and type of proposed discharges to waters of the state (e g surface runoff sanitary wastewater industrial/ commercial effluent "wash down and residential discharges) None b Number of lots or parcels 1 d Size of area to be graded filled or disturbed including roads ditches etc 3000SF f List the materials (such as marl paver stone asphalt or concrete) to be used for impervious surfaces Paverstones and Concrete h Projects that require a CAMA Mayor Development Permit may also require a Stormwater Certification (i) Has a site development plan been submitted to the Division of Water Quality for review? ❑Yes ®No ❑NA (n) If yes list the date submitted k Have the facilities described in Item (i) received state or local approval? ®Yes ❑No ❑NA If yes attach appropriate documentation m Does the proposed project include an innovative stormwater design? []Yes ®No [_]NA If yes attach appropriate documentation C -J--- Z '64 V);1 �qJ .)a" ,�-1 ( rte; ,. - e m Describe proposed drinking water supply source (e g well community public system etc) Public Water Supply o When was the lot(s) platted and recorded? �zZ //Z Date 1 , �iGv- Prolect Namet NRYLOA) G CJ�rT� Applicant Name ApplicanfSi*&ture n (i) Will water be impounded? (u) If yes how many acres? J-) r- �, _,. t - taL . Vo ❑NA J r� T L p If proposed development is a subdivision will additional utilities be installed for this upland development? ❑Yes []No ®NA Form DCM MP-4 STRUCTURES (Construction within Public Trust Areas) i rn —k Attach this form to Joint Application for CAMA Major Permit Form DCM MP 1 Be sure to complete all other sections of the Joint Application that relate to this proposed project Please include all supplemental information 1 DOCKING FACILITY /MARINA CHARACTERISTICS a (i) Is the docking facility /manna ❑Commercial ®Public/Govemment ❑Pnvate /Community c (i) Dock(s) and /or pier(s) (ii) Number 1 (iii) Length 220 Total ( 176 over water) (n►) Width 80 (v) Floating ❑Yes ®No e (i) Are Platforms included? ®Yes [_-]No If yes (ii) Number Severa See Narrativel (iii) Length 3,088 SF (m) Width See Plan (v) Floating ®Yes ®No Note Roofed areas are calculated from dnphne dimensions g (i) Number of slips proposed 0 (ii) Number of slips existing 0 i Check the proposed type of siting ❑ Land cut and access channel ❑Open water dredging for basin and /or channel ®Open water no dredging required []Other please describe El This section not apphcab/e b (i) Will the facility be open to the general public? ®Yes []No d (i) Are Finger Piers included? []Yes ®No If yes (u) Number (in) Length (iv) Width (v) Floating ❑Yes []No f (i) Are Boatlifts included? []Yes ®No If yes (ii) Number (in) Length (iv) Width h Check all the types of services to be provided ❑ Full service including travel lift and /or rail repair or maintenance service ❑ Dockage fuel and marine supplies ❑ Dockage (`beet slips ) only number of slips ❑ Dry storage number of boats ❑ Boat ramp(s) number of boat ramps ® Other please describe _ Aquarium Teaching /fishing pier I Describe the typical boats to be served (e g open runabout charter boats sail boats mixed types) Kayaks k Typical boat length 12 1 (1) Will the facility be open to the general public? J Fr " ?" - --W" SAP -�* is r -,- Cgr -, -J �ia,. �, , q e) m (i) Will the facility have tie pilings? ®Yes ❑No (n) If yes number of he pilings? 5 to support floating platform only r r, E r r- , ) ®Yes ❑No y t ,M 2 DOCKING FACILITY /MARINA OPERATIONS [I This section not applicable a Check each of the following sanitary facilities that will be included in the proposed project ❑ Office Toilets ® Toilets for patrons Number Location Provided within Aquarium ❑ Showers ❑ Boatholdmg tank pumpout Give type and location b Describe treatment type and disposal location for all sanitary wastewater No wastewter is intended for the pier or storage budding c Describe the disposal of solid waste fish offal and trash Trash Receptacles will be used at the Storage Budding and on the pier d How will overboard discharge of sewage from boats be controlled? Not Permitted e (i) Give the location and number of No Sewage Discharge signs proposed N/A (u) Give the location and number of Pumpout Available signs proposed f Describe the special design if applicable for containing industrial type pollutants such as paint sandblasting waste and petroleum products N/A g Where will residue from vessel maintenance be disposed of? N/A h Give the number of channel markers and No Wake signs proposed N/A I Give the location of fuel handling facilities and describe the safety measures planned to protect area water quality N/A 1 What will be the manna policy on overnight and live- aboard dockage? Not Permitted k Describe design measures that promote boat basin flushing? N/A I If this project is an expansion of an existing marina what types of services are currently provided - T No m Is the manna/docking facility proposed within a primary or seconds area? ❑Yes ®No secondary nursery n Is the manna/docking facility proposed within or adjacent to any shellfish harvesting area? []Yes ®No o Is the manna/docking facility proposed within or adjacent to coastal wetlands /marsh (CW) submerged aquatic vegetation (SAV) shell bottom (SB) or other wetlands (WL)? If any boxes are checked provide the number of square feet affected ❑CW ❑SAV ❑SB OWL ®None p Is the proposed manna/docking facility located within or within close proximity to any shellfish leases? []Yes ®No If yes give the name and address of the leaseholder(s) and give the proximity to the lease 3 BOATHOUSE (including covered lifts) ®This section not applicable a (i) Is the boathouse structure(s) ❑Commercial ❑PubliclGovernment ❑Private /Community (u) Number (m) Length (iv) Width Note Roofed areas are calculated from dnplrne dimensions 4 GROIN (e g wood sheetprle etc If a rock groin use MP 2 Excavation and Fill) ID This section not applicable a (Q Number (u) Length (m) Width 5 BREAKWATER (e g wood sheetprle etc) ®This section not applicable a - Length -- -- — - - - -- - — - — — - - -b- Average distance from NHW NWL or wetlands--- - - - -- c Maximum distance beyond NHW NWL or wetlands 6 MOORING PILINGS and BUOYS ®This section not applicable .. u uic au ua,iwc \ar ❑Commercial ❑Public/Government ❑Pnvate /Community c Distance to be placed beyond shoreline Note This should be measured from marsh edge if present b Number d Description of buoy (color inscription size anchor etc) m e Arc of the swing 7 GENERAL a Proximity of structure(s) to adjacent riparian property lines 427 to South PL & 759 to North PL Note For buoy or mooring piling use arc of swing including length of vessel c Width of water body 19,000 ft e (i) Will navigational aids be required as a result of the project? ❑Yes []No [DNA (n) If yes explain what type and how they will be implemented f I b Proximity of structure(s) to L,--n"decking-faddies- 490 Emergency Ferry Dock to south d Water depth at waterward end of structure at NLW or NWL 4 5 NWL 8 OTHER [I This section not applicable a Give complete description This pier will be used for educationsi recreational and fishing opportunities and will pnmanliy be used by patrons of the Aquarium or those leasing the facility for private events t✓C12 ZA z-- Date Project Name YLM yyo AJ L GJK� T� Applicant Name � / Y, /J� 7 ::._ L) Applicant Signature ROANOKE, ISLAND AQUARIUNI. BOARDWALK, PIER, & GAZE�B 1 if - III COV COVER SHEET A -1.41 PLAN: PIER BUILDING ELEVATIONS: PIER GAZEBO & STORAGE BUILDING S-1.01 PIER PILE PFJ1 PIER DETAILS NO SCALE north VICINITY MAP NO SCALE ALEMARLE & ASSOCIATES, Ltd. Civil / Structural 115 West St. Clair Street Kill Devil Hills, NC 27948 252.441.2113 SGE SOLUTIONS PC 215 Glenwood Ave., Suite A Raleigh NC 27603 919 -821 -3886 CONSULTANTS north Plumbing / Electrical XX COLUMN LINE PLAN EQUIPMENT SYMBOL X Ax.xx X INTERIOR ELEVATION SEE CHAPTER 100 DRAW111GS SEE CHAPTER 400 DRAWINGS T -0 TOILET ACCESSORY NOTE X SEE CHAPTER 200 DRAWdNGS D ## ROOF DETAIL REFERENCE ROOM NUMBER SEE CHAPTER 300 DRAWINGS SEE CHAPTER 600 DRAWNGS FOR ROOM FINISH SCHEDULE xOOtX DOOR NUMBER zx BUILDING ELEVATION SEE CHAPTER 600 DRAWl.'A"GS FOR DOOR SEE CHAPTER 400 DRAWINGS SCHEDULE HM —# HOLLOW METAL FRAME: NUMBER SEE CHAPTER 600 DRAW1fG5 X X BUILDING SECTION AX.XX AX.XX SEE CHAPTER 500 DRAWINGS XX ALUMINUM FRAME NUMBER SEE CHAPTER 600 DRAVffiGS 000.00 ELEVATION A xx WALL SECTION SEE CHAPTER 500 DRAWINGS 00.00 FFE FINISH FLOOR ELEVATION X CASEWORK ELEVATION A7.OX SPOT ELEVATION SEE CHAPTER 700 DRAWINGS 00.00 (),RT It -CAROL IN A, , . AU5 SCO ID #: 10-08739-01A 01 JUNE 2012 s anson +steVYal i architects, p.a. 400 west morgan st., suite 204 raleigh, north carolina 27603 (t) 919.326.8820 (e) BarryS @SandSarchitects.com 01 JUNE 2012 Q N N N N O N N N cr 3 z Q a w T- 0 i 0) i� 0 0 Q C) i U) 0 CL O r7 O E O D- a z 0 0 V .V 0 n N U Q v VyyJq q � ADDITION -iy 1 TURTLE y A14 p ( r �y� ) ' \ q ��� SO C, BY OTHERS _ \• • .. N.T.S. IX SEPTIC, j f p u r + u ' \ ( V r— f PLw HaJSE q °� �L �`- ;'� PROPOSED 10' WIDE 1. OWNER: NORTH CAROLINA PUBLIC AQUARIUM r / s \ D q PROPOSED WATER AND CONCRETE ACCESS DRIVES �' �( GaNGRETE q D ELECTRIC SERVICES ,, 0 (BY OTHERS) 2. PROPERTY ADDRESS: 374 AIRPORT ROAD � ` D 1 ' ,q p q ! \ � a MANTEO, N ° C 27954 q . p / '`•�- 3. THE OWNER INTENDS TO CONSTRUCT A SOUNDFRONT PIER WITH GAZEBO AND \0 V) D l A BOAT STORAGE BUILDING AND ASSOCIATED IMPROVEMENTS. 10 • Ex �n t 4. PROPERTY RECORDED IN D.B. 200, PG. 397 \ :T a. i> q 3 q • ° {, p D �Q 4 q x 9 `tJ\RTLE STA�TL� E . ��,r p ;� . .� . / —\ p K Q ^ q • D' ° °® D q i qD i q /� %\ DARE COUNTY PIN #: 9870 11 55 5186 q p q ° q q D D — p 4 � E X GONGREM D . D 4 5. PROPERTY ZONED: INDUSTRIAL DISTRICT (I 6. SETBACKS PER CURRENT ZONING: FRONT 15 / . D q 4 q Vp q i ATCH EXISTING D q REAR 10' SIDES 20' PROPifSED PAVER + ADJOINING RESIDENTIAL 75' * "° r wor AREA \o D PROPOSED 7. PROPERTY LOCATED IN A FLOOD ZONE AE (7) AND SHADED X AS PER FIRM ° ` "•\ \�.\' r';; t` EXISTING PINE STORAGE _ _ _ r4 –� TO BE REMOVED BUILDING _ — 9_ �h+V \��; + MAP 3720987000J, DATED SEPTEMBER 20, 2006. _ ' y , ' "\ _ %��% 4 ? _ a _ — _ — FFE - a s'— / PROPOSED KAYAK \` \� ' � _ _ — �� PRACTICE OSPREY � (SUBJECT TO CHANGE BY FEMA -lo- �-�_: �a �a ._.._..- � :,:. \ \; \s \\y ,;:,,. �,; CE AREA NEST _ _ _ — — a.,� `«, ", >,� ✓% - _ m IIMrrY MA N.T.S. GRAPHIC SCALE 20 0 10 20 40 :0 (IN FEET) 1 INCH = 20 FT. + /40 + /0 N + + + + i1 n1� PROPOSED PIER o + PROPOSED ADA COMPLIANT FISHING AREAS (TYP) 0 0 PROPOSED GAZEBO /mt?� + + a 0 1 0 a aqo + a + + Nw RW MONUMENT FOUND in + S r 'y EXISTING TREELINE 145 PK NAIL SET X EXISTING FENCE qw IRON ROD FOUND 4J y --10- NEW TRAFFIC FLOW ARROWS gc.�,r CONCRETE MONUMENT FOUND & + qpt= i rx EXISTING FIRE HYDRANT PROPOSED h RIGHT OF WAY LANDING = 4.66' + EXISTING WATER VALVE + + /40 + /0 N + + + + i1 n1� PROPOSED PIER o + PROPOSED ADA COMPLIANT FISHING AREAS (TYP) 0 0 PROPOSED GAZEBO /mt?� + + a 0 1 0 a aqo + a + + Nw RW MONUMENT FOUND ' ' 'y ' "_ -1'..v `,'r_l EXISTING TREELINE 145 PK NAIL SET X EXISTING FENCE qw IRON ROD FOUND 4J y --10- NEW TRAFFIC FLOW ARROWS gc.�,r CONCRETE MONUMENT FOUND & NEW HANDICAP PARKING SPACE qpt= IRON PIN FOUND rx EXISTING FIRE HYDRANT — — RIGHT OF WAY X EXISTING WATER VALVE BOUNDARY LINE ❑ EXISTING WATER METER EXISTING POWER POLE Qo /o EXISTING SANITARY CLEANOUT EXISTING GUY WIRE gRa EXISTING IRRIGATION VALVE OVERHEAD ELECTRIC EXISTING DRAINAGE PIPE O EXISTING TELEPHONE PEDESTAL "-------- - - - -'- EXISTING DITCH /SWALE /POND EXISTING LIGHT POLE d , EXISTING CONTOURS a. a` EXISTING CONCRETE \klvi EXISTING SPOT ELEVATIONS :: EXISTING PAVEMENT 9&flf"-] no] iv, I k a CAI j 9 f a � be'nnarle & ASSOCIATES, LTD. Engineering - Environmental -Land Planning 115 West Saint Clair St. Phone: (252) 441.2113 P.O. Box 3989 Fax: (252) 441 -0965 Kill Devil Hills, NC 27948 w .AlbemarleAssociates.com Certificate of Licensure No. C -1027 SCALE: 1 " = 20' 01 Un��1�ii►� VERTICAL CEMENT BOARD SIDING (PAINTED) O I 0 I d- M O I i� N IN O I M 0 I i� N O I 107 MEN WEST ELEVATION (EAST REVERSED): STORAGE BUILDING WOOD BRACKETS (PAINTED) CEMENT BOARD CORNER BOARDS & TRIM (PAINTED) CEMENT BOARD SIDING (PAINTED) WOOD LOUVERS (PTD.) OVER FIBERGLASS SCREENING I I 1 12 VERTICAL CEMENT (� BOARD SIDING, 9 CORNER BOARDS & _ TRIM (PAINTED) ASPHALT SHINGLES ON ROOFING PAPER ON 3/4" MARINE GRADE PLYWOOD 24 "x24" CASED - OPENING 03 SOUTH ELEVATION (NORTH REVERSED): PIER GAZEBO ASPHALT SHINGLES ON ROOFING PAPER ON PRESSURE TREATED WOOD 2X6 T &G ROOF DECK WOOD KNEE BRACEEI (PAINTED) SCALE: 1/4"=l'-O" i a1 AQUARIUM EXCHIBIT DISPLAY STAND ATTACHED TO PIER RIM JOIST. SEE DETAIL A- 4.01/XX FOR ADDITIONAL INFORMATION. 02 REMOVABLE PROJECT WORK TABLE LOCATION. 0 SEE DETAIL A- 4.01/XX FOR ADDITIONAL INFORMATION. 03 BUILT -IN WOOD BENCH. SEE DETAILS A- 4.01 /XX FOR ADDITIONAL INFORMATION. 04 - -- � 05 - -- as - -- EQUIPMENT LEGEND 1. ALTERNATE BID ITEMS ARE SUMMARIZED IN THE PROJECT MANUAL, 2. ALL EXTERIOR CONCRETE SIDEWALKS AND /OR SURFACES SHALL BE FLUSH WITH FINISHED FLOOR ELEVATIONS AND SLOPE AWAY FROM THE BUILDING AT MINIMUM OFY4" PER FOOT FORA MINIMUM OF 8' -0 ", FROM THIS 8' -0" DISTANCE TO THE END OF THE SURFACE, THE MINIMUM SLOPE SHALL BE %" PER FOOT TO A MAXIMUM OF Y2" PER FOOT. REFER TO CIVIL DRAWINGS FOR EXTENT OF PAVED AREAS AND SPOT ELEVATIONS. 3. PIER PLAN DIMENSIONS ARE SHOWN TO INSIDE FACE OF RIM JOISTS. SEE CIVIL /STRUCTURAL DRAWINGS FOR SECTIONS AND DETAILED PLAN DIMENSIONS. 4. BOATHOUSE EXTERIOR PLAN DIMENSIONS ARE TYPICALLY SHOWN TO EXTERIOR FACE OF FRAMING. INTERIOR PLAN DIMENSIONS ARE TYPICALLY SHOWN FROM INSIDE FACE OF FRAMING TO INSIDE FACE OF FRAMING. ALL DIMENSIONS SHOWN ARE NOMINAL, 5. SEE COVER SHEET FOR SYMBOL LEGEND. 6. SEE CIVIL & STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION. 7. SEE ELECTRICAL AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. 02 GENERAL PLAN NOTES RAWINGS LAYOUT & LOCATION PLAN: SOUNDSIDE PIER 11 SCALE: 1/8 " =1' -0" 01 Q N N Ln 00 N O N O On 3 a z Q J d X W 0- Z QO O t7 Q0 O 1 U _U Li O O U C tT N Q) O a i O Q0 O E 0 a Q U z I O LO 0 U N O li N U Q Y B C D E F G H I J K L M N 0 P TQ R TS T U TV W TX 1' 8' -0" 8' -0" 8' -0" 8' -0" 7' -Q" 8' -6" 10' -0" 10' -0" 10' -0" 10' -0'" 10' -Q" 1 Q' -Q" 10' -0" 101-011 10' -0" 10' -Q" 10' -0" 10' -0" 10' -Q" 10' -0" 10' -0" 10' -0" 10' -0" 2' -0" 10"0 PILES �.01 NTS PLAN: SOUNDSDE PIER ❑o 'IER ELEV. 8.6' be marle & ASSOCIATES, LTD. Engineenng - Environmental - Land Planning 115 West Saint Clair St. Phone: (252) 441 -2113 north P.C. Box 3989 Fax: (252) 441.0965 Kill Devil Hills, NC 27948 www.Albemar]eAssociates.com Certificate of Licensure No. C -1027 (I SCALE: 1/8 " =1' -0" 01 Q N 0 M 00 N 0 N e z Q I CL w a i _ c0 0 0 0 0 Q U c N 0 i T_ CD 0 r7 c0 0 L. O 6 Q U z i 0 0 U N O L d qJ U a a y STRUCTURAL NOTES 1. WHERE A DETAIL IS SHOWN ON STRUCTURAL DRAWINGS FOR ONE COR iTION, IT SHALL APPLY TO ALL SIMILAR OR LIKE CONDITIONS UNLESS NOTED OF SHOWN OTHERWISE ON PLANS. 2. ALL ITEMS SHALL BE TIGHTLY ANCHORED OR ATTACHED SQUARE, PLUMB /'.ND TRUE, OR IN OTHER PLANES AND SHAPES AS SHOWN ON THE DRAWINGS. JOIK7S SHALL BE TIGHT, EVEN AND FREE OF OFFSETS. NO FIELD ALTERING OF ANY MEMEEERS WILL BE ALLOWED THAT WILL CAUSE THEM NOT TO BE IN ACCORDANCE 'KITH THE DRAWINGS AND SPECIFICATIONS WITHOUT WRITTEN APPROVAL OF THE PROJECT ENGINEER. 3. IF THE CONTRACTOR FINDS A DIFFERENCE BETWEEN THESE DRAWINGS AND EXISTING ELEVATIONS OR OTHER CONDITIONS THAT PROHIBIT EXECUTION OF THE WORK AS DIRECTED IN THESE DRAWINGS, THE CONTACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY. 4. TIMBER PILES SHALL BE A MINIMUM OF 2.5 CCA UC58 AND SHALL MEET OR EXCEED AWPA STANDARDS (C -18) FOR PRESERVATION TREATMENT AS APPLICABLE. PILES SHALL ACHIEVE A MINIMUM OF 18' PENETRATION INTO SUITABLE SUBSURFACE MATERIAL. 5. STRUCTURAL FRAMING BE #2 SYP, TREATMENT AS SHOWN, AND SHALL (MEET OR EXCEED AWPA STANDARDS (UC4C) FOR PRESERVATION TREATMENT AS APPLICABLE. 6. DECKING SHALL BE #1 SYP, TREATMENT AS SHOWN, AND SHALL MEET OR EXCEED AWPA STANDARDS (UC4B) FOR PRESERVATION TREATMENT AS APPLICABLE. 7. ALL CROSS BRACING SHALL BE #2 GRADE MATERIAL WITH A MINIMUM OF 2.5 CCA UC5B (MOISTURE CONTENTS <19 %) AND SECURED WITH (2) 1 "0 HDG BOLTS IN PRE - DRILLED HOLES. 8. ALL FASTENERS SHALL BE HIP -DIP ZINC COATED IN ACCORDANCE WITH AST,1 A 153. WOOD BENCHES (NOT SHOWN) (2) 1" HDG MARINE BOLTS 6x6 HAUCH BRACES UC513 (1) 1" HDG _ MARINE BOLT 14" 6x6 LEDGER W/ (3) 1" HDG MARINE BOLTS �--- -- 7' -0" -� 1 PIER SECTION NTS 30'-'0"0 TIP CLASS B TIMBER PILIN (18' MIN. PENETRATION) ALL PILES "0 BE TREATED Tn 1) 5 C(".'. 1 1C5R PFR MC: 2 "x6" CAP Rim M7-AL NTS RECESS UPPER RAIL BETWEEN POSTS WHERE HANDRAIL IS PROVIDED 4.1(C)(6) -RAMP HANDRAILS 12�� SHALL BE 1j" TO 14" IN. 1 WIDTH OR DIAMETER WITH THE OUTSIDE FACE OF THE HANDRAIL A MAXIMUM 3j" FROM THE WALL OR BUILDING 7j" FACE HANDRAIL 2" X 8" 34" MIN. TO 38" MAX TO FINISHED RAMP WALKING SURFACE ALL SURFACES ON HANDRAIL TO BE ROUTED AND SANDED STAGGER 2x12 JOIN *TS 2x8 2x6 2x4 TIES !,EACH GIRDER (TYP) CAD 8" O.C. 12 STAGGER 3 JOINTS 2x10 SET INTO POLE UC48 ON LAND UC5B BELOW 1.0' MSL PION ADA COMPLIANT RAMP WITH HANDRAILS 2 "x6" #1 DECKING UC413 DETAIL) SCREWED W /3" STAINLESS STEEL DECK SCREWS (2 /JOISTS) 3' 4" 2 "x8" JOISTS ELEV. = 4.66' I 2x8 BAND 12" O.C. UCB4 2x8 BAND ELEV. = 3.00' o- i ®i 2 "x6" #1 DECKING UC4B SCREWED W /3" STAINLESS STEEL DECK SCREWS (2 /JOISTS) 2 "x10" JOISTS 12" O.C. i m i -5' -4" (4) 2"02" GIRDERS UC4B TWO ON EACH SIDE OF PILING W/ (3) 1 " HDG MARINE BOLTS EACH PILING (SEE DETAIL) NORMAL WATER LEVEL ±1.0' 4x8 CROSS BRACING UC58 (2) 3/a" HDG MARINE BOLTS EACH BENT 0 EACH CONNECTION N5' L_ i-• 7'-0" --) 30' -10 "0 TIP CLASS B TIMBER PILING (18' MIN. PENETRATION) ALL PILES TO BE TREATED TO 2.5 CCA UC5B PER NC BUILDING CODE PRESCRIPTION 18' -28' i : i 18" 6' -11" SIMPSON H10 HURRICANE ® EACH TRUSS 2x6 STUDS ® 16" O.C. HORIZONTAL BRIDGING 0 EACH COURSE 8" CMU N4" ALLTHREAD W /IN 24" OF EACH CORNER AND SPACED ® 48" MAXIMUM IN GROUTED CELLS #3 GR60 REBAR ® 32" O.C. i (3) #4 GR60 REBAR (CONTINUOUS) 2 "x6" #1 DECKING UC4B ELECTRIC AND SCREWED W /3" STAINLESS WATER SERVICE STEEL DECK SCREWS (2 /JOISTS) CONDUITS —L XIV JVIJIJ I 12" O.C. UC411 -5' -4" (4) 2"x12" GIRDERS UC4B TWO ON EACH SIDE OF PILING W/ (3) 1 " HDG MARINE • BOLTS EACH PILING (SEE DETAIL) 7N X7 NORMAL WATER LEVEL ±1.0' 4x8 CROSS BRACING UC513 (2) 3/a" HDG MARINE BOLTS EACH BENT 9 EACH CONNECTION -5' BOTTOM MEN • . 30' -10 "0 TIP CLASS B TIMBER PILING (18' MIN. PENETRATION) n ALL PILES TO BE TREATED 30 2.5 CCA UC5B PER NC BUILDING CODE PRESCRIPTION N28' 3 PER SECTION I r I e NTS &ASSOCIATES, LTD. Engineering - Environmental -Land Planning 115 West Saint Clair St. Phone: (252) 441 -2113 P.O. Box 3989 Fax: (252) 441-0965 Kill Devil Hills, NC 27948 www.AlbemarleAssociates.com Certificate of Licensure No. C -1027 SCALE: AS SHOWN 01 16 APRIL 2012