Loading...
HomeMy WebLinkAboutNCG030075_2021 DMR_20210218wood. Wood Environment & Infrastructure Solutions, Inc. February 10, 2021 Mr. Jack Martindale BorgWarner Turbo Systems Post Office Box 15075 Asheville, North Carolina 28813 Subject: Report of January 2021 Stormwater Discharge Sampling BorgWarner Emissions, Thermal, and Turbo Systems Arden, North Carolina Wood Project 6252-16-0240.06 Dear Mr. Martindale: 1308-C Patton Avenue Asheville, NC 28806 USA T:828-252-8130 www.woodpic.com Wood Environment & Infrastructure Solutions, Inc. (Wood) is pleased to submit this Report of January 2021 Stormwater Discharge Sampling for the BorgWarner Emissions, Thermal, and Turbo Systems facility located on Brevard Road in Arden, North Carolina. This sampling was performed to comply with requirements contained in the General Permit for Stormwater Discharge (Permit NCG030000 effective November 1, 2018 issued by the North Carolina Department of Environmental Quality (NCDEQ). BorgWarner's certificate of coverage under this permit is NCG030075. Background Information Seven stormwater outfalls are located at the site, as shown on the attached Figure 1. In 2015, NCDEQ approved a request for representative outfall status, whereby outfalls OF-1 and OF-3 are the only outfalls to be sampled. The outfalls discharge directly and indirectly into Clayton Creek prior to Clayton Creek's confluence with the French Broad River. According to NCDEQ's water quality classification of the French Broad River basin, Clayton Creek and the adjacent portion of the French Broad River are not currently classified as the following sensitive receiving waters: Outstanding Resource Waters, High Quality Waters, Primary Nursery Areas and Trout Waters. Therefore, the more protective benchmark value listed in the General Permit for total suspended solids (50mg/L) does not apply to stormwater discharges at the site — the applicable benchmark value for total suspended solids is 100 mg/L. A rain gauge is present at the site North Carolina Corporate Engineering License No. F-1253; Geology No. C-247 0 BorgWarner Emissions, Thermal, and Turbo Systems January 2021 Stormwater Discharge Sampling Report Wood Project 6252-16-0240.06 February 10, 2021 approximately six feet above ground in an open area at a distance of at least twice the height of surrounding structures. Because of consecutive detections of zinc above the NCDEQ benchmark value, a Tier Two response was implemented at outfall OF-3 in early 2020. In addition to semi-annual stormwater sampling, Wood conducted investigative sampling in March and September in relation to the exceedances of zinc at OF-3. The results of the investigative sampling were included in separate investigative reports. In summary, the old dock roof, new dock roof, Coolant Room roof, and likely the Steam Room roof each appear to be a potential source of zinc in stormwater ultimately detected at the downstream outfall OF-3 location. In response to the results of the investigative sampling, BorgWarner painted the old dock roof. This report addresses the monthly sampling component of the Tiered response for outfall OF-3 and is the first sampling event since painting the old dock roof. January 2021 Stormwater Sampling Activities Wood personnel were onsite to perform stormwater sampling during a measureable storm event on January 25, 2021. The storm event occurred between approximately 6:00 AM and 9:00 AM on January 25, 2021. Wood personnel performed stormwater sampling of the discharge starting at approximately 6:30 AM when constant measureable discharge was produced. Total rainfall for this event was 0.68 inches as measured at the on -site rain gauge the same day after the samples were collected. Rainfall sufficient to produce a measureable discharge was not recorded during the 72 hours prior to this measurable storm event. Within about 30 minutes of constant measurable discharge, the pH of the stormwater was measured with a calibrated pH meter, and a stormwater sample was collected from outfall OF-3. The sample was packed in an ice -chilled cooler and delivered with chain -of -custody via overnight courier to Pace Analytical in Mt. Juliet, Tennessee (a North Carolina -accredited laboratory) for analysis. The outfall sample was submitted for analysis of total lead, total zinc, and total copper according to Standard Method 6020B, total suspended solids (TSS) according to Standard Method 2540D, and non -polar oil and grease according to EPA Method 1664B (SGT-HEM). BorgWarner Emissions, Thermal, and Turbo Systems January 2021 Stormwater Discharge Sampling Report Wood Project 6252-16-0240.06 February 10, 2021 In addition to analytical monitoring, Wood performed qualitative monitoring at stormwater discharge outfall OF-3. The qualitative monitoring included the observation of the following discharge characteristics: color, odor, clarity, floating solids, suspended solids, foam, oil sheen, erosion or deposition, and other obvious indicators of stormwater pollution. The completed Stormwater Discharge Outfall Qualitative Monitoring Report is attached to this report. Field analysis of the stormwater samples indicated pH readings were within the NCDEQ benchmark range. Laboratory analytical results indicated the concentration of zinc exceeded the NCDEQ benchmark value (benchmark) of 0.126 milligrams per liter (mg/L) in the sample collected from outfall OF-3 (0.279 mg/L). The concentration of copper (0.0162) exceeded the benchmark of 0.010 mg/L. The remaining monitored parameters were below their respective NCDEQ benchmark values. The analytical results for the outfall samples are reported on the attached NCDEQ Semi -Annual Stormwater Discharge Monitoring Report. The laboratory analytical report and chain of custody records are attached to this report. Based on the January 2021 sampling results, a continued Tier Two and a Tier Three response is warranted at outfall OF-3. Wood recommends contacting the NCDEQ regional office contact, as per the Tier Three response requirements in relation to the eighth consecutive detection of zinc and sixth detection of copper within this permit period above the benchmark value at OF-3. The NCDEQ regional office contact may complete the following in relation to the Tier Three response: • Require that the permittee revise, increase, or decrease the monitoring and reporting frequency for some or all of the parameters herein; • Require sampling of additional or substitute parameters; • Require the permittee to install structural stormwater control measures; • Require the permittee to implement other best management practices; • Require the permittee to perform upstream and downstream monitoring to characterize impacts on receiving waters; or • Require the permittee implement site modifications to qualify for a No Exposure Exclusion; 0 Require the permittee to continue Tier Three obligations through the permit renewal process. BorgWarner Emissions, Thermal, and Turbo Systems January 2021 Stormwater Discharge Sampling Report Wood Project 6252-16-0240.06 February 10, 2021 The painting of the old dock roof appears to have improved zinc concentrations for this initial sampling event; however, the results indicate additional mitigation may still be required to reduce zinc concentrations to below benchmark values. The investigative sampling events also indicate that the roofs are not contributing to the elevated copper concentrations occasionally detected at outfall OF-3. The copper concentration detected in a surface runoff sample indicates the copper concentration is likely a ground surface source. Wood recommends submitting this documentation of stormwater sampling, along with the attached Stormwater Discharge Outfall Monitoring Report, to NCDEQ for their files. We appreciate the opportunity to provide water resource services on this project. If you should have any questions, or need additional information, please do not hesitate to contact us at (828) 252-8130. Sincerely, Wood Environment & Infrastructure Solutions, Inc. Gregory L. Hutchins. Technical Professional II GLH/MEW:glh w4u 4-. (liduc— Matthew E. Wallace, P.E. Principal Engineer Attachments: Figure 1: Site Drainage Plan NCDEQ Stormwater Discharge Monitoring Report Qualitative Monitoring Report Laboratory Analytical Report and Chain -of -Custody Soso M O9+Z - I oeiz "eta._ t. ; -5'�� `'+._ •. °<<z LL _ O 0 m O � Z C uMl N tip N� to N I 01 u O. E °+ _ a 0 N o Q N Ln N n Ol M _ Q N Q `1 OD ."I Ol 00 V 00 ry Q H — to to to to to Ln to C O LV m fV o0 fV a0 fV m fV 00 N 00 N 00 y C\ 00 N Ol M Ol Il1 a •m- v v a v c q M M M Ln I M m tll l0 n w J- o ,� uR1fM[ Lot cNt Ii e h 1� t_ a 10 IF O"a Ov" 10 0 o , �r �aa�� is w � O � m � J om yo 3 N N o U t 2 Q U Tl V Q Q N � a m T � ILU 0 Li c O o n T � C �- Ol 9 M1 O LL LL C�oocn N M ? # LO (0 # N o rn 10 N aL rn 10 N N N w w m Ol m 01 l0 N N v v w m C C C S s C C C c d o a! ; v « ? J 7 3 o c o c Y Li U d E U N 0.1 O U u U m _ :% 3 c m 'mac Li E E ° T O m U rn U O (n U CO 1W Di vironmen t al Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https://deq.nc.gov/about/divisions/energy-mineral-land- resources/ npdes-stormwater-gps Permit No.: N/C/G/0/3/0/0/0/0 or Certificate of Coverage No.: N/C/G/0/3/0/0/7/5 Facility Name: BorgWarner Emissions, Thermals, and Turbo Systems County: Buncombe Inspector Date of Inspection: Time of Inspection Hutchins — Wood E& 1 /25/21 Total Event Precipitation (inches): 6:30 Phone No. (828)252-8130 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. OF-3 Structure (pipe, ditch, etc.): Pipe Receiving Stream: Clayton Creek Describe the industrial activities that occur within the outfall drainage area: Manufacturing of turbo parts, assembly of turbos, and shipping and receiving of materials. Page 1 of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): None 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 O 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids inthe stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: O 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 O 3 4 5 7. Is there any foam in the stormwater discharge? C Yes 8. Is there an oil sheen in the stormwater discharge? oYes 9. Is there evidence of erosion or deposition at the outfall? C 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/O1/2018 aceAnalytical a ANALYTICAL REPORT l — National Center for Testing & Innovation February 02, 2021 i >& Wood E&I Solutions Inc. - Asheville, NC Sample Delivery Group: L1310306 Samples Received: 01/26/2021 Project Number: 6252-16-0240.03 Description: BorgWarner Site: NCG030075 Report To: Gregory Hutchins 1308-C Patton Avenue Asheville, NC 28806 Entire Report Reviewed By: Heather J Wagner Project Manager Results relate only to the items tested or calibrated and are reported as rounded values. This test report shall not be reproduced, except in full, without written approval of the laboratory. Where applicable, sampling conducted by Pace Analytical National is performed per guidance provided in laboratory standard operating procedures ENV-SOP-MTJL-0067 and ENV-SOP-MTJL-0068. Where sampling conducted by the customer, results relate to the accuracy of the information provided, and as the samples are received, 1! ACCOUNT: PROJECT: SDG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville, NC 6252-16-0240.03 L1310306 02/02/21 13:18 1 of 12 TABLE OF CONTENTS ONE LAB. NATIONWIDE. Tc: Table of Contents 2 FP Ss: Sample Summary 3 Cn: Case Narrative 4 Sr: Sample Results 5 FS OF-3 L1310306-01 5 Qc: Quality Control Summary 6 Fn Gravimetric Analysis by Method 2540 D-2011 6 Fr Wet Chemistry by Method 1664B 7 Metals (ICPMS) by Method 6020E 8 MC GI: Glossary of Terms 10 Al: Accreditations & Locations 11 GI Sc: Sample Chain of Custody 12 VAI BSc ACCOUNT: PROJECT: S DG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville, NC 6252-16-0240.03 L1310306 02/02/21 13:18 2 of 12 SAMPLE SUMMARY ONE LAB. NATIONWIDE. OF-3 L1310306-01 GW Collected by Gregory Hutchins Collected date/time 01/25/2106:30 Received date/time 01/26/2109:00 E Method Batch Dilution Preparation Analysis Analyst Location date/time date/time FC Gravimetric Analysis by Method 2540 D-2011 WG1613861 1 01/30/2109:57 01/30/2111:39 CAT Mt. Juliet, TN Wet Chemistry by Method 1664E WG1614627 1 01/29/2109:28 02101/2110:25 ERK Mt, Juliet, TN Metals (ICPMS) by Method 6020B WG1612282 1 02/01/2103:29 02101/2113:00 LAT Mt. Juliet, TN Metals (ICPMS) by Method 6020E WG1612282 5 02/01/2103:29 02/01/2115:44 LAT Mt. Juliet, TN Fn Fr r-QC1 F F FC ACCOUNT: PROJECT: SDG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville, NC 6252-16-0240.03 L1310306 02/02/21 13:18 3 of 12 CASE NARRATIVE ONE LAB. NATIONWIDE. All sample aliquots were received at the correct temperature, in the the FP proper containers, with appropriate preservatives, and within method specified holding times, unless qualified or notated within the report. Where applicable, all MDL (LOD) and RDL (LOQ) values reported for environmental samples F have been corrected for the dilution factor used in the analysis. All Method and Batch Quality Control are within established criteria except where addressed in this case narrative, a non-conformance form or properly qualified within the sample results. By my digital signature below, I affirm to the best of my E knowledge, all problems/anomalies observed by the laboratory as having the potential to affect the quality of the data have been identified by the laboratory, and no information or data have been knowingly withheld that would affect the quality of the data. 0 E RC Fil Heather J Wagner Project Manager E BSc ACCOUNT: PROJECT: SDG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville, NC 6252-16-0240.03 L1310306 02/02/2113:18 4 of 12 OF-3 SAMPLE RESULTS - 01 ONE LAB. NATIONWIDE. Collected date/time: 01/25/21 06:30 L1310306 Gravimetric Analysis by Method 2540 D-2011 r Result Qualifier RDL Dilution Analysis Batch Analyte ug/I ug/1 date / time Suspended Solids 49500 12500 1 01/30/202111:39 WG1613861 Wet Chemistry by Method 1664B Result Qualifier RDL Dilution Analysis Batch Analyte ug/I ug/I date / time TPH - Oil & Grease ND 5000 1 02/01/20211025 WG1614627 Sample Narrative: L1310306-01 WG1614627: Total Oil&Grease is non -detect. Extract was not processed through silica gel. Metals (ICPMS) by Method 6020B Result Qualifier RDL Dilution Analysis Batch Analyte ug/I ug/I date / time Copper 16.2 B 5.00 1 02101/202113:00 WG1612282 Lead 4.34 2.00 1 02/01/202113:00 WG1612282 Zinc 279 125 5 02/01/202115:44 WG1612282 ACCOUNT: PROJECT: SDG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville. NC 6252-16-0240.03 L1310306 02/02/21 13:18 5 of 12 D 0 C O (Z Q y O_ O_ 0 O y Q E UO C u (N O c� O cm O J d tD O m � O o N m 0 N � O m - 0 m m a o m o0 a � � N C io C:) c o O m o O � N N O m 0 N O a o o -o m v J � c � M _v Q cn O Q E M V) C_ C1 O N 0 Ln It O co J G U J_ O_ E co Ln O C O U O M O M .J * EEEZEZEE ui 0 2 Z O F=- Q z ro Q J W Z O ( V 3 0 V) U J v u Q 0 Q E ro v ! 0 U ?+ O i 0 J cn U J_ Q 0 L c 0 U O O J E J U C U O J o Q LO N O � v N O O m V ,J O � V m ° o ip � o m U a amo U J O Q O N Y _ O O O N O N V a� o v v m u m a o a � LO C, o Q N J ui z Z O Q Z O] Q J LL Z O CQ CG G I� v / J O� o o N o_ Z "2 N pJ U a _ w w 0 m m > O O � J J Q D X M_ J J o o � � O O o M Ol N ; o o � o W W � 0 o 00 • cn G L�"1 rL O O J OD OD J a Q) x N N Y � w p p N J O O � C) �l1 J 111 V% J V V V O m J 5 J i5 O O y Q. Q Q co l0 O LO M _ E V Y _ O O CQ C Y _ OO) N LNO of O � of O O - N of O O .N-. — .L N m N m _ 76 N O N C C)o a 0 o 0 o c c N N �E co c� Lo �, v r' fl m m m ItN � O m O N co 00 V C4 -0 °C2 O O O co O to m m C) rn L a, L � a O m O Of v O v m n N d] c U fO 0 U m c m Q U ? Q N J J Q U3 J J Q iv J �E J CL CL o O O a � o n c o a U Lii O a o eo 00 W t N W N H O Q � 0 N O LO O O 0 N J * F 9 F —u— I Fu) I Mu Fu'� I M F 9 1 F; i I Fc -o I W Z O H Q Z m g w z O ry LL Q` cG L D Cf)1 J OZ o O SCf) O v Zm 0— M U L) Q �- zi Q U) X (y L (V'1 � U) O 0- U) X U) O co a) O Q o E ID co a N 0 t � ' N � � 00 O N 2 O Tl- a � 0 u O ( O � J 0 0 p N m J GLOSSARY OF TERMS ONE LAB. NATIONWIDE. Guide to Reading and Understanding Your Laboratory Report The information below is designed to better explain the various terms used in your report of analytical results from the Laboratory. This is not Ed intended as a comprehensive explanation, and if you have additional questions please contact your project representative. Results Disclaimer- Information that may be provided by the customer, and contained within this report, include Permit Limits, Project Name, TC Sample ID, Sample Matrix, Sample Preservation, Field Blanks, Field Spikes, Field Duplicates, On -Site Data, Sampling Collection Dates/Times, and Sampling Location. Results relate to the accuracy of this information provided, and as the samples are received. Abbreviations and Definitions FS MDL ND Method Detection Limit. Not detected at the Reporting Limit (or MDL where applicable). Fn RDL Reported Detection Limit. Rec. Recovery. RPD Relative Percent Difference. FSr SDG U Sample Delivery Group. Rc Not detected at the Reporting Limit (or MDL where applicable). Analyte The name of the particular compound or analysis performed. Some Analyses and Methods will have multiple analytes reported. If the sample matrix contains an interfering material, the sample preparation volume or weight values differ from the Dilution standard, or if concentrations of analytes in the sample are higher than the highest limit of concentration that the laboratory can accurately report, the sample may be diluted for analysis. If a value different than 1 is used in this field, the aAl result reported has already been corrected for this factor. These are the target % recovery ranges or % difference value that the laboratory has historically determined as normal Limits for the method and analyte being reported. Successful QC Sample analysis will target all analytes recovered or duplicated within these ranges. e Original Sample The non -spiked sample in the prep batch used to determine the Relative Percent Difference (RPD) from a quality control SC sample. The Original Sample may not be included within the reported SDG. This column provides a letter and/or number designation that corresponds to additional information concerning the result Qualifier reported. If a Qualifier is present, a definition per Qualifier is provided within the Glossary and Definitions page and potentially a discussion of possible implications of the Qualifier in the Case Narrative if applicable. The actual analytical final result (corrected for any sample specific characteristics) reported for your sample. If there was no measurable result returned for a specific analyte, the result in this column may state "ND" (Not Detected) or "BDL" Result (Below Detectable Levels). The information in the results column should always be accompanied by either an MDL (Method Detection Limit) or RDL (Reporting Detection Limit) that defines the lowest value that the laboratory could detect or report for this analyte. Uncertainty (Radiochemistry) Confidence level of 2 sigma. A brief discussion about the included sample results, including a discussion of any non -conformances to protocol Case Narrative (Cn) observed either at sample receipt by the laboratory from the field or during the analytical process. If present, there will be a section in the Case Narrative to discuss the meaning of any data qualifiers used in the report. Quality Control This section of the report includes the results of the laboratory quality control analyses required by procedure or Summary (Qc) analytical methods to assist in evaluating the validity of the results reported for your samples. These analyses are not being performed on your samples typically, but on laboratory generated material. This is the document created in the field when your samples were initially collected. This is used to verify the time and Sample Chain of date of collection, the person collecting the samples, and the analyses that the laboratory is requested to perform. This Custody (Sc) chain of custody also documents all persons (excluding commercial shippers) that have had control or possession of the samples from the time of collection until delivery to the laboratory for analysis. This section of your report will provide the results of all testing performed on your samples. These results are provided Sample Results (Sr) by sample ID and are separated by the analyses performed on each sample. The header line of each analysis section for each sample will provide the name and method number for the analysis reported. Sample Summary (Ss) This section of the Analytical Report defines the specific analyses performed for each sample ID, including the dates and times of preparation and/or analysis. Qualifier Description B The same analyte is found in the associated blank. J The identification of the analyte is acceptable; the reported value is an estimate. ACCOUNT: PROJECT: SDG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville, NC 6252-16-0240.03 L1310306 02/02/2113:18 10 of 12 ACCREDITATIONS & LOCATIONS ONE LAB. NATIONWIDE. .� Pace National is the only environmental laboratory accredited/certified to support your work nationwide from one location. One phone call, one point of contact, one laboratory. No other lab is as accessible or prepared to handle your needs throughout the country. Our capacity and capability from our single location laboratory is comparable to the collective totals of the network laboratories in our industry. The most significant benefit to our one location design is the design of our laboratory campus. The model Is conducive to accelerated productivity, decreasing tum-around time, and preventing cross contamination, thus protecting sample Integrity. Our focus on premium quality and prompt service allows us to be YOUR LAB OF CHOICE. ' Not all certifications held by the laboratory are applicable to the results reported in the attached report. ` Accreditation is only applicable to the test methods specified on each scope of accreditation held by Pace National. Pace Analytical National 12065 Lebanon Rd Mount Juliet, TN, 37122 Alabama 40660 Nebraska NE-OS-15-05 Alaska 17-026 Nevada TNO00032021-1 Arizona AZ0612 New Hampshire 2975 Arkansas 88-0469 New Jersey—NELAP TNO02 California 2932 New Mexico' TN00003 Colorado TN00003 New York 11742 Connecticut PH-0197 North Carolina Env375 Florida E87487 North Carolina DW21704 Georgia NELAP North Carolina' 41 Georgia' 923 North Dakota R-140 Idaho TN00003 Ohio—VAP CL0069 Illinois 200008 Oklahoma 9915 Indiana C-TN-01 Oregon TN200002 Iowa 364 Pennsylvania 68-02979 Kansas E-10277 Rhode Island LA000356 Kentuckytfi KY90010 South Carolina 84004002 Kentucky' 16 South Dakota n/a Louisiana A130792 Tennessee'" 2006 Louisiana LA018 Texas T104704245-20-18 Maine TN00003 Texas' LAB0152 Maryland 324 Utah TN000032021-11 Massachusetts M-TNO03 Vermont VT2006 Michigan 9958 Virginia 110033 Minnesota 047-999-395 Washington C847 Mississippi TNO0003 West Virginia 233 Missouri 340 Wisconsin 998093910 Montana CERT0086 Wyoming A2LA A2LA— ISO 17025 1461.01 AIHA-LAP,LLC EMLAP 100789 A21-A— ISO 17025 a 1461.02 DOD 1461.01 Canada 1461.01 USDA P330-15-00234 EPA—Crypto TN00003 Pace Analytical National 1313 Point Mallard Parkway SE Suite B Decatur, AL, 35601 Alabama 40160 ANSI National Accreditation Board L2239 Pace Analytical National 660 Bercut Dr. Ste. C Sacramento, CA, 95811 California 2961 Oregon CA300002 Minnesota 006-999465 Washington C926 North Dakota R-214 Pace Analytical National 6000 South Eastern Avenue Ste 9A Las Vegas, NV, 89119 Nevada NVO094120214 Pace Analytical National 1606 E. Brazos Street Suite D Victoria, TX, 77901 Texas T104704328-20-18 ' Drinking Water ' Underground Storage Tanks 3 Aquatic Toxicity `ChemicallMicrobiological a Mold 5 Wastewater n/a Accreditation not applicable ACCOUNT: PROJECT: SDG: DATE/TIME: PAGE: Wood E&I Solutions Inc. - Asheville, NC 6252-16-0240.03 L1310306 02/02/21 13:18 11 of 12 00 - '• l C11 7 n N z o In 7 O rc CO CU .. t. U •• u U b 'O W ' i, 4 JO a Sm c Hmmmm ••U� a � a u 0 r a O QO " a u lmi .ai c F mU U L.-:3i roUui Q Cal m m V 0 -j o O, 17 i, O v L 2 a N m A O ro N U W m y ro ci U U O O r^ O •' G U �] ? O d O w u° CN _ SaadON 3ddH-1 l SSl lDH-1MAD-IL X3HD0Hdl y 7 £ONH-3d(]HILuOSZ OZ09 Aq uZ,gd `n:) a u — WLj J u Z > c -- O Qe V O G7 Y = > C) O co C ry -C Z o W a, YO 11 Q o o a Vc _ C) > Cl — � n L Q E l7 o u On'—---' , s = Z o _ 0 rq M LL ` U- _— Y W C( a E c U Co ;n ci U I. r m 1 m u l�l 421 co c Ln 3 ~-`.-` = liJ o0 r s CT y C, 07�o C7 O FD C c O Cov c°� �� O ^c�3o0 cc c NCDEQ Division of Energy, Mineral and Land Resources Stormwater Discharge Monitoring Report (DMR) Form for NCG030000 Metal Fabrication Click here for instructions Complete, sign, scan and submit the DMR via the Stormwater NPDES Permit Data Monitoring Report (DMR) Upload form within 30 days of receiving sampling results. Mail the original, signed hard copy of the DMR to the appropriate DEMLR Regional Office. Certificate of Coverage No. NCG03 0 0 7 5 Person Collecting Samples: Gregory Hutchins, Wood E&IS Facility Name: BorgWarner Emissions, Thermal, and Turbo Systems Laboratory Name: Pace Analytical Facility County: Buncombe 0 Laboratory Cert. No.: ENV 375 Discharge during this period: ❑■ Yes ❑ No (if no, skip to signature and date) Has your facility implemented mandatory Tier response actions for any benchmark exceedances? U Yes U No If so, which Tier (I, II, or III)? II I 0 Analytical Monitoring Requirements for Outfalls with Industrial Activities — Benchmarks in (Red) Parameter Parameter Outfall 03 Outfall Outfall Outfall Outfall Code N/A Receiving Stream Class C N/A Date Sample Collected MM/DD/YYYY 1/25/2021 46529 24-Hour Rainfall in inches 0.68 00552 Non -Polar Oil & Grease in mg/L (15) <5.000 C0530 TSS in mg/L (100 or 50*) 49.500 00400 pH in standard units (6.0-9.0) 7.58 NCOIL New Motor/Hydraulic Oil Usage in <55 gal/month 01119 Copper, total recoverable in mg/L 0.0162 (0.010 FW, 0.005 SW) 01051 Lead, total recoverable in mg/ L 0.00434 (0.075 FW, 0.220 SW) 01094 Zinc, total recoverable in mg/ L (0.126 0.279 FW, 0.095 SW) 78141 Total Toxic Organics (TTO) in mg/L(1) NA * Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HOW), Trout Waters (Tr) and Primary Nursery Areas (PNA) have a benchmark TSS limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L. Notes (optional): "I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing 94olations." Zj(-z, ZI Signature ofl5ermittee or De,16& fed Authorised Individual Date