Loading...
HomeMy WebLinkAboutNC0033553_CEI_20210302 SENT VIA ELECTRONIC MAIL ONLY: NO HARD COPY WILL BE MAILED March 02, 2021 Aaron Greene, Superintendent Email: agreene@polkschools.org Polk County Board of Education SUBJECT: Compliance Inspection Report Polk Central School NPDES WW Permit No. NC0033553 Polk County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Polk Central School on 2/10/2021. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in NPDES WW Permit No. NC0033553. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact me at 828-296-4686 or via email at mikal.willmer@ncdenr.gov. Sincerely, Mikal Willmer, Environmental Specialist II Water Quality Regional Operations Section Asheville Regional Office Division of Water Resources, NCDEQ ATTACHMENTS: Inspection Report Ec: LF Deborah Bradley, ORC DocuSign Envelope ID: D2C18E74-3CB1-4C44-B6F3-EBC32534E2FB EPA United States Environmental Protection Agency Washington, D.C. 20460 Water Compliance Inspection Report Form Approved. OMB No. 2040-0057 Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 N 52 NC0033553 21/02/10 C S31112171819 20 21 66 Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 QA ----------------------Reserved------------------- N67707172 73 74 75 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include POTW name and NPDES permit Number) Polk Central School 576 NC Hwy 9 S Mill Spring NC 28756 Entry Time/Date Permit Effective Date Exit Time/Date Permit Expiration Date 08:30AM 21/02/10 18/11/01 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) /// Deborah M Bradley/ORC/828-859-5626/ Other Facility Data 09:05AM 21/02/10 23/07/31 Name, Address of Responsible Official/Title/Phone and Fax Number Aaron Greene,PO Box 638 Columbus NC 287220638/Superintendent/828-894-3051/Contacted No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Self-Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s)Agency/Office/Phone and Fax Numbers Date Mikal Willmer DWR/Division of Water Quality/828-296-4686/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page#1 DocuSign Envelope ID: D2C18E74-3CB1-4C44-B6F3-EBC32534E2FB 3/2/2021 3/2/2021 NPDES yr/mo/day 21/02/10 Inspection Type C3111218 1 Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Mikal Willmer, with the Asheville Regional Office, conducted a compliance evaluation inspection of the Polk Central WWTP on February 2, 2021. This inspection was conducted to determine whether the facility is being operated and maintained in compliance with NPDES Permit No. NC0033553. Deborah Bradley, ORC, was present and assisted in the inspection. Overall, the facility appeared to be in compliance. The operator logbook was reviewed, and the ORC was taking pH, temp and chlorine readings at the time of the inspection and estimating flow. The school contracts Triple A Septic to pump the tanks onsite. Sand filter beds appeared to be raked and free of vegetation and ponding. Drain valves were closed at the end of the perforated drain lines and there was no indication of overloading occurring across the beds. ORC indicated School staff usually remove any weeds/vegetation from the sand filter beds. No issues reported with effluent numbers due to increased cleaning protocols since Covid. Ms. Bradley stated the School was obtaining quotes to replace the media of the sand filter beds. The School may also pursue upgrading the wastewater treatment facility if budget allows. The sample location is downstream of all treatment components; however, the sample port size makes sampling and flow estimation more difficult. Recommend increasing the size of the sampling port if/when the facility is next upgraded, since the effluent pipe is across the highway and a field. Currently there is not a spigot near the wastewater system. It is recommended the school provide a means to rinse down any treatment components for routine cleaning for operations and maintenance staff. NC0033553 17 (Cont.) Page#2 DocuSign Envelope ID: D2C18E74-3CB1-4C44-B6F3-EBC32534E2FB Permit:NC0033553 Inspection Date:02/10/2021 Owner - Facility: Inspection Type: Polk Central School Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Facility consists of a grease trap, septic tank, dosing tank, effluent tank, surface sand filter, tablet chlorinator and dechlor. Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? All tanks are locked and the sand filter is fenced off.Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? Is flow meter calibrated annually? Is the flow meter operational? (If units are separated) Does the chart recorder match the flow meter? Permit only requires instantaneous flow. See summary for details.Comment: De-chlorination Yes No NA NE Type of system ?Tablet Is the feed ratio proportional to chlorine amount (1 to 1)? Is storage appropriate for cylinders? # Is de-chlorination substance stored away from chlorine containers? Comment: Are the tablets the proper size and type? Are tablet de-chlorinators operational? Number of tubes in use?2 Comment: Septic Tank Yes No NA NE Page#3 DocuSign Envelope ID: D2C18E74-3CB1-4C44-B6F3-EBC32534E2FB Permit:NC0033553 Inspection Date:02/10/2021 Owner - Facility: Inspection Type: Polk Central School Compliance Evaluation Septic Tank Yes No NA NE (If pumps are used) Is an audible and visual alarm operational? Is septic tank pumped on a schedule? Are pumps or syphons operating properly? Are high and low water alarms operating properly? Tanks are gravity fed.Comment: Sand Filters (Low rate)Yes No NA NE (If pumps are used) Is an audible and visible alarm Present and operational? Is the distribution box level and watertight? Is sand filter free of ponding? Is the sand filter effluent re-circulated at a valid ratio? # Is the sand filter surface free of algae or excessive vegetation? # Is the sand filter effluent re-circulated at a valid ratio? (Approximately 3 to 1) Surface sand filter bed covered with gravel with PVC distribution lines.Comment: Effluent Sampling Yes No NA NE Is composite sampling flow proportional? Is sample collected below all treatment units? Is proper volume collected? Is the tubing clean? # Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees Celsius)? Is the facility sampling performed as required by the permit (frequency, sampling type representative)? Permit only requires grab samples. Samples are collected below the effluent weir. See summary for details. Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? Are the receiving water free of foam other than trace amounts and other debris? If effluent (diffuser pipes are required) are they operating properly? Effluent pipe terminates into South Branch Little White Oak Creek across the highway. See summary for details. Comment: Page#4 DocuSign Envelope ID: D2C18E74-3CB1-4C44-B6F3-EBC32534E2FB Certificate Of Completion Envelope Id: D2C18E743CB14C44B6F3EBC32534E2FB Status: Completed Subject: Please DocuSign: NC0033553_CEI_20210302.pdf, NC0033553_CEI_20210302.ltr.docx Source Envelope: Document Pages: 5 Signatures: 3 Envelope Originator: Certificate Pages: 2 Initials: 0 Mikal Willmer AutoNav: Enabled EnvelopeId Stamping: Enabled Time Zone: (UTC-05:00) Eastern Time (US & Canada) 217 W. Jones Street Raleigh, NC 27699 Mikal.willmer@ncdenr.gov IP Address: 149.168.204.10 Record Tracking Status: Original Mar 2, 2021 | 13:02 Holder: Mikal Willmer Mikal.willmer@ncdenr.gov Location: DocuSign Security Appliance Status: Connected Pool: StateLocal Storage Appliance Status: Connected Pool: North Carolina Department of Environmental Quality Location: DocuSign Signer Events Signature Timestamp Mikal Willmer mikal.willmer@ncdenr.gov Environmental Specialist North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 149.168.204.10 Sent: Mar 2, 2021 | 13:04 Viewed: Mar 2, 2021 | 13:04 Signed: Mar 2, 2021 | 13:04 Electronic Record and Signature Disclosure: Not Offered via DocuSign Daniel Boss daniel.boss@ncdenr.gov Environmental Specialist North Carolina Department of Environmental Quality Security Level: Email, Account Authentication (None) Signature Adoption: Pre-selected Style Using IP Address: 149.168.204.10 Sent: Mar 2, 2021 | 13:04 Viewed: Mar 2, 2021 | 13:05 Signed: Mar 2, 2021 | 13:12 Electronic Record and Signature Disclosure: Not Offered via DocuSign In Person Signer Events Signature Timestamp Editor Delivery Events Status Timestamp Agent Delivery Events Status Timestamp Intermediary Delivery Events Status Timestamp Certified Delivery Events Status Timestamp Carbon Copy Events Status Timestamp Witness Events Signature Timestamp Notary Events Signature Timestamp Envelope Summary Events Status Timestamps Envelope Summary Events Status Timestamps Envelope Sent Hashed/Encrypted Mar 2, 2021 | 13:04 Certified Delivered Security Checked Mar 2, 2021 | 13:05 Signing Complete Security Checked Mar 2, 2021 | 13:12 Completed Security Checked Mar 2, 2021 | 13:12 Payment Events Status Timestamps