HomeMy WebLinkAboutNC0000892_Sampling Results_20210301 din
Performance Applied
RECEIVED
MAR 01 2021
Arclin NCDEQIDWRINPDES
790 Corinth Road
Moncure,NC 27559
February 19, 2021
NC Department of Environmental Quality
Division of Water Resources
Attn: Central Files
1617 Mail Service Center
Raleigh,North Carolina 27699-1617
Re: January 21, 2021 PFAS Sampling Results
Permit: NC0000892
Arclin USA,LLC
Chatham County
Class II
Please find enclosed the PFAS Sampling Results Report for January 21, 2021,and the required PFAS
Industrial Input Spreadsheet. This report is for the Arclin USA facility located at 790 Corinth Road,
Moncure,North Carolina.
If you have any questions,please contact Bowman Harvey at 919-545-5753.
Sincerely, .
Brian Reddy
Arclin
Plant Manager
Pace Analytical Services,LLC
aceAnalytical 6701 Conference Drive
www.pacelalu.eom Raleigh,NC 27607
(919)834-4984
February 08, 2021
David Lorbacher
Arclin-Dynea/Moncure
790 Corinth Road
Chapel Hill, NC 27599
RE: Project: PFAS
Pace Project No.: 92517799
Dear David Lorbacher:
Enclosed are the analytical results for sample(s)received by the laboratory on January 21,2021. The results relate only to
the samples included in this report.
Analyses were performed at the Pace Analytical Services location indicated on the sample analyte page for analysis unless
otherwise footnoted.
The test results provided in this final report were generated by each of the following laboratories within the Pace Network:
•Pace Analytical Services-Charlotte
If you have any questions concerning this report,please feel free to contact me.
Sincerely,
Tyriek Hooks
tyriek.hooks@pacelabs.com
(704)875-9092
Project Manager
Enclosures
cc: Bowman Harvey,Acrlin-Dynea/Moncure
Bowman Harvey,Arclin-Dynea/Moncure
Chis Lamm,Arclin-Dynea/Moncure
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
without the written consent of Pace Analytical Services,LLC. Page 1 of 30
Pace Analytical Services,LLC
®
www.pacelabs.cam 6701 Conference Drive Raleigh,NC 27607
aceAnalytical
(919)834-4984
CERTIFICATIONS
Project: PFAS
Pace Project No.: 92517799
Pace Analytical Services Charlotte
9800 Kincey Ave.Ste 100,Huntersville,NC 28078 South Carolina Certification#:99006001
Louisiana/NELAP Certification#LA170028 Florida/NELAP Certification#:E87627
North Carolina Drinking Water Certification#:37706 Kentucky UST Certification#:84
North Carolina Field Services Certification#:5342 VirginiaNELAP Certification#:460221
North Carolina Wastewater Certification#:12
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
without the written consent of Pace Analytical Services,LLC. Page 2 of 30
Pace Analytical Services,LLC
ace Analytical 6701 Conference Drive
Raleigh,NC 27607
www.pacelabs.com (919)834-4984
SAMPLE ANALYTE COUNT
Project: PFAS
Pace Project No.: 92517799
Analytes
Lab ID Sample ID Method Analysts Reported Laboratory
92517799003 Grab EPA 624 By SIM LMB 3 PASI-C
PASI-C=Pace Analytical Services-Charlotte
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
without the written consent of Pace Analytical Services,LLC. Page 3 of 30
Pace Analytical Services,LLC
6701 Conference Drive
aceAnalytical
www.pacelabs.com Raleigh,NC 27607
(919)834-4984
ANALYTICAL RESULTS
Project: PFAS
Pace Project No.: 92517799
Sample: Grab Lab ID: 92517799003 Collected: 01/21/21 11:50 Received: 01/21/21 12:45 Matrix:Water
Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual
624 Volatiles by SIM Analytical Method:EPA 624 By SIM
Pace Analytical Services-Charlotte
1,4-Dioxane(p-Dioxane) ND ug/L 2.0 1 01/22/21 14:46 123-91-1
Surrogates
Toluene-d8(S) 87 % 60-140 1 01/22/21 14:46 2037-26-5
1,2-Dichloroethane-d4(S) 87 % 60-140 1 01/22/21 14:46 17060-07-0
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 4 of 30
Pace Analytical Services,LLC
aceAnalytical 670 ence Drive
Raleigh,NC 27607
www.pacelabs.com (919)834-4984
QUALITY CONTROL DATA
Project: PFAS
Pace Project No.: 92517799
QC Batch: 594754 Analysis Method: EPA 624 By SIM
QC Batch Method: EPA 624 By SIM Analysis Description: 624 MSV Volatiles by SIM
Laboratory: Pace Analytical Services-Charlotte
Associated Lab Samples: .92517799003
METHOD BLANK: 3137849 Matrix: Water
Associated Lab Samples: 92517799003
Blank Reporting
Parameter Units Result Limit Analyzed Qualifiers
1,4-Dioxane(p-Dioxane) ug/L ND 2.0 01/22/21 11:36
1,2-Dichloroethane-d4(S) % 84 60-140 01/22/21 11:36
Toluene-d8(S) % 86 60-140 01/22/21 11:36
LABORATORY CONTROL SAMPLE: 3137850
Spike LCS LCS %Rec
Parameter Units Conc. Result %Rec Limits Qualifiers
1,4-Dioxane(p-Dioxane) ug/L 20 19.3 97 60-140
1,2-Dichloroethane-d4(S) % 85 60-140
Toluene-d8(S) % 85 60-140
MATRIX SPIKE&MATRIX SPIKE DUPLICATE: 3137851 3137852
MS MSD
92517799003 Spike Spike MS MSD MS MSD %Rec
Parameter Units Result Conc. Conc. Result Result %Rec %Rec Limits RPD Qual
1,4-Dioxane(p-Dioxane) ug/L ND 20 20 19.9 20.3 96 98 60-140 2
1,2-Dichloroethane-d4(S) % 82 83 60-140
Toluene-d8(S) % 82 81 60-140
Results presented on this page are In the units Indicated by the"Units"column except where an alternate unit is presented to the right of the result.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 5 of 30
Pace Analytical Services,LLC
6701 Conference Drive
aceAnalytical Raleigh,NC 27607
www.pacelabs.ecm (919)834-4984
QUALIFIERS
Project: PFAS
Pace Project No.: 92517799
DEFINITIONS
DF-Dilution Factor,if reported,represents the factor applied to the reported data due to dilution of the sample aliquot.
ND-Not Detected at or above adjusted reporting limit.
TNTC-Too Numerous To Count
J-Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL-Adjusted Method Detection Limit.
PQL-Practical Quantitation Limit.
RL-Reporting Limit-The lowest concentration value that meets project requirements for quantitative data with known precision and
bias for a specific analyte in a specific matrix.
S-Surrogate
1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270.The result for each analyte is
a combined concentration.
Consistent with EPA guidelines,unrounded data are displayed and have been used to calculate%recovery and RPD values.
LCS(D)-Laboratory Control Sample(Duplicate)
MS(D)-Matrix Spike(Duplicate)
DUP-Sample Duplicate
RPD-Relative Percent Difference
NC-Not Calculable.
SG-Silica Gel-Clean-Up
U-Indicates the compound was analyzed for,but not detected.
Acid preservation may not be appropriate for 2 Chloroethylvinyl ether.
A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA
Method 8260.
N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for
each analyte is a combined concentration.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 6 of 30
Pace Analytical Services,LLC
® 6701 Conference Drive
aceAnal ical Raleigh,NC 27607
Yt 9 .
www.pacelabs.com (919)834-4984
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Project: PFAS
Pace Project No.: 92517799
Analytical
Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch
92517799003 Grab EPA 624 By SIM 594754
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced,except in full,
Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 7 of 30
� I
Document Name: Document Revised:October 28,2020
Sample Condition Upon Recelpt(SCUR) Page 1 of 2
aeeAnalytieal' Document No.: Issuing Authority:
F-CAR-CS•033-Rev.07 Pace Carolinas quality Office
Laboratory receiving samples:
•
Asheville❑ Eden❑ Greenwood❑ Huntersvi(le El Raleigh( ] Mechanicsville❑ Atlanta❑ KernersvilleEl
SampleCon Condition Client Name-__ Project U: r W® r 92517799_ ____
°o teeit
Courier: ['Fed Ex ❑UPS DUSPS ❑Cllent ( 111111 1111111111
0 Commercial Pace ['Other:
92517799
Custody Seal Present? Dyes No Seals Intact? Dyes QNo
Date/Initials Person Examining Contents: ri/A-Z1-2./
Packing Material: ❑Bubble Wrap ['Bubble Bags ,None 0 Other Biological Tissue Frozen?
Thermometer: ❑Yes ❑No jSdN/A
❑IR Gun ID:
q1 7d0 T
5F4Wet ['Blue ONone ype of Ice:
Correction Factor:
Cooler Temp: �'v Add/Subtract(°C) Q. d Temp should be above freezing to 6°C
['Samples out of temp criteria.Samples on Ice,cooling process
Cooler Temp Corrected('C): '7 - jj' hasbegun
USDA Regulated Soil(�f N/A,water sample) It
Did samples originate in a uarantine zone within the United States:CA,NY,or SC(check maps)? Did samples originate from a foreign source(Internationally, 1
['Yes ❑No including Hawaii and Puerto Rico)?Oyes ❑No
Comments/Discrepancy:
Chain of Custody Present? I?'es Duo ON/A 1.
Samples Arrived within Hold Time? ,+jYes ❑No IN/A 2,
Short Hold Time Analysis(<72 hr.)? Dyes CjNo ON/A 3.
Rush Turn Around Time Requested? DYes RN° ON/A 4,
Sufficient Volume?. • j4Yes ❑Na ON/A 5.
Correct Containers Used? ,Yes Duo ❑N/A 6,
-Pace Containers Used? Yes Duo ON/A
Containers Intact? gYes Duo ON/A 7.
Dissolved analysis:Samples Field Filtered? Oyes Duo jjaN/A 8.
Sample Labels Match COC? Dyes ❑No ❑N/A 9.
•
-Includes Date/Time/ID/Analysts Matrix:
•
Headspace in VOA Vials(>5-6mm)? Des ❑No ON/A 10.
Trip Blank Present? :Yes ❑Na qN/A 11.
I
Trip Blank Custody Seals Present? []Yes ❑No WN/A
COMMENTS/SAMPLE DISCREPANCY Field Data Required? Oyes ❑No
i
Lot ID of split containers: j )
CLIENT NOTIFICATION/RESOLUTION 1
� c
.
t :
Person contacted: Date/Time: i
i
itProject Manager SCURF Review: Date:
Project Manager SRF Review: Date: ? I I
i #
Page 8 of 30
I
I
Document Name: Document Revised:October 28,2020 i
aceAnalyfical' Sample Condition Upon Receipt(SCUR) Page 2 of 2 •
Document No.: Issuing Authority:
F-CAR-CS•033-Rev,07 Pace Carolinas Quality Office
"Check mark top half of box If pH and/or dechlorination is Project# i
verified and within the acceptance range for preservation WO# : 92517799
samples. PM: TIN Due Date: 02/04/21
Exceptions;VOA,Coliform,TOC,Oil and Grease,DRO/8015(water)DOC,LLHg CLIENT: 91—Arcl 1nDyn
Bottom half of box is to list number of bottles
I
�q,�q�
is
u b u a ^ Z Z j
•
V Y ? Q z z a .m Qi '^
z •N 'i
•
4' 9 " ° E vv 4' iE. 2 CL\ 4 ` vZ - <v Za « a v = _ < <
Ll a A .e ,,; " a a z I ' Z ? H
''
7 > > c 1,1 S z O v V = r� 2 Q ? O ? O t" Z 7 O c
u Y u " L v a` 1. y a E x z O T Y Y m a �` .
a a a A ro a ro o a E E .4 E '^ O < < < iv °' E c E
a a a E � E ¢ ry O � �'
' J J J 6. J J � ¢ J ¢ J. > > � > N H J J J V7 <
E E E y E E E E 6 v v E E r¢n E -' J 9 - -E E E J
S n vs = Q1 0 m E E E E p E E
rNa N .i N N ti �Ny .y r1 �ry ryN-�I N t
O 4 I
tV N Vat K( 2 O 2 bN U t07 M M ^ M Cn tp�� a' aw ~ -_,,� fxi 6 m m ' 0 gi X > X O # a a te7 ,his 2
1 1 \ \ j
2 \ \
1-\\I ' .
a \ \ 1
4 .\\ -
\\
\\ , •
I ' \
7 \ \ ,
8
\ \
9 \ \ T
10 \ \ 1 •
`•
11 \
12 \ \\.\\
•
•
pH Adjustment Log for Preserved Samples
Sample ID Type of Preservative_ pH upon receipt Date preservation adjusted Time preservation Amount of Preservative lot p
adjusted added
r•
Note: Whenever there Is a discrepancy affecting North Carolina compliance samples,a copy of this form will be sent to the North Carolina DEHNR Certification Office(I.e. j !
Out of hold,incorrect preservative,out of temp,incorrect containers.
i
i
1
i
1i
Page 9 of 30
PACE ANALYTICAL SERVICES, LLC
aceAnalytical 106 Vantage Point Drive •West Columbia,SC 29172 Number L 1613 8
Telephone No.803-791-9700 Fax No.803-791-9111
www.pacelabs.com
Client A Report to Contact Telephone o./E-mail Quote No.
s'C-T �c�tlmck. �v9 (19)- `{$— G326)
Address Sampler's S" t yj Analysis(Attach list it mom space is needed)
`710 �ri( 'fo(• Page of
City //�,�� (�/� S(ttattee1 Zip e Q X l Lot 0 Bar Code
r -�on e.J..1 r ei 1 559 Printed Name (we use only)
Project Name z!co(�c'. W x
titoc� (,1� ?EA nN+
l A^
Project No. , . /� t PO.No. t Matrix No of Containers C°
/Vt on
-r 0 by Preservative Type 1
Sample ID/Dc\wription Collection Collection Time n 2 r 3 x Z 4$ (� r •y
(Containers far each samara maybe combined on one Ana.) Dates) (IltiGrary) 7 z g 4 "`-' Remarks/Cooler LD• L S(�I!
_IN tue.nk-- i141u 11:&t5 G % X oot
Field jjcks-*- il2t 2t (1:440 2 X ®4z
cab ( P2112t I(= 60 ' Li x 0.7
Turn Around Time Required(Prior lab approval resulted for expedited TAT.) Sample Disposal Possible Hazard Identification DC Requirements(Specify)
0 Standard u R h(Specify) 0 Return to Client El Disposal by Lab 0 Non-Hazard ElFlammable 0 Skin Irritant 0 Poison ❑Unknown
i.RaJin ked
fr&e€- Da Time i.Rocei by De a TAm
i.off
� 2 curt t�=y5 ,IZ i f 2 15
2.Relinquished by Dale Time 2. ecelvod by Date Time
3.Relinquished by Date Time 3.Received by Dale Time
4.Relinquished by Date Time 4.Laboratory received by Date Time
Note:All samples are retained for four weeks from receipt LAB USE ONLY Term Blank D Y 0 N
unless other arrangements are made. Received on ice(Circle) Yes No Ice Pack Receipt Temp.2 -46- 'C •
-o
co DISTRIBUTION:WHITE&YELLOW-Return to laboratory with Sampee(s);PINK-FieldfClient Copy Document Number:ME003N2.01
CD
0
0
C)
ace Analytical
Report of Analysis
Pace Analytical Services, Inc.
9800 Kincey Avenue
Suite 100
Huntersville, NC 28078
Attention: Tyriek Hooks
Project Name: Savannah Wood
Project Number: 92517799
Lot Number:WA23002
Date Completed:02/05/2021
02/05/2021 7:17 PM
Approved and released by:
Project Manager II: Karen L. Coonan
s 'f; AliAB
ANSI Nadm i/Accreditation Band
.,. � ACCREDITED
-1123133M--
TESTING LABORATORY
The electronic signature above is the equivalent of a handwritten signature.
This report shall not be reproduced,except in its entirety,without the written approval of Pace Analytical Services, LLC.
Pace Analytical Services, LLC(formerly Shealy Environmental Services, Inc.)
106 Vantage Point Drive West Columbia, SC 29172
Tel: 803-791-9700 Fax:803-791-9111 www.pacelabs.com
Page 11 of 30
Page 1 of 20
PACE ANALYTICAL SERVICES, LLC
SC DHEC No:32010001 NELAC No:E87653 NC DENR No:329 NC Field Parameters No:5639
Case Narrative
Pace Analytical Services, Inc.
Lot Number:WA23002
This Report of Analysis contains the analytical result(s)for the sample(s) listed on the Sample Summary
following this Case Narrative. The sample receiving date is documented in the header information
associated with each sample.
All results listed in this report relate only to the samples that are contained within this report.
Sample receipt, sample analysis, and data review have been performed in accordance with the most
current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace")
Laboratory Quality Manual, standard operating procedures(SOPs), and Pace policies.Any exceptions to
the TNI standards, the Laboratory Quality Manual, SOPs or policies are qualified on the results page or
discussed below.
If you have any questions regarding this report please contact the Pace Project Manager listed on the
cover page.
In the Matrix Spike and Matrix Spike Duplicate(MS/MSD) associated with sample-001, PFDOS
recovered outside of the acceptance limits. The Laboratory Control Spike (LCS) recovered within the
required acceptance limits; therefore, this demonstrates a matrix effect and data quality is not impacted.
Pace Analytical Services,LLC(formerly Shealy Environmetal Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172(803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 12 of 30
Page 2 of 20
PACE ANALYTICAL SERVICES, LLC
Sample Summary
Pace Analytical Services, Inc.
Lot Number: WA23002
Project Name: Savannah Wood
Project Number: 92517799
Sample Number Sample ID Matrix Date Sampled Date Received
001 Effluent Aqueous 01/21/20211145 01/23/2021
002 Field Blank Aqueous 01/21/2021 1140 01/23/2021
(2 samples)
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 13 of 30
Page 3 of 20
PACE ANALYTICAL SERVICES, LLC
Detection Summary
Pace Analytical Services, Inc.
Lot Number: WA23002
Project Name: Savannah Wood
Project Number: 92517799
Sample Sample ID Matrix Parameter Method Result Q Units Page
001 Effluent Aqueous PFBS PFAS by ID 7.1 ng/L 5
001 Effluent Aqueous PFHxS PFAS by ID 5.9 ng/L 5
001 Effluent Aqueous PFBA PFAS by ID 9.6 ng/L 5
001 Effluent Aqueous PFHpA PFAS by ID 6.4 ng/L 5
001 Effluent Aqueous PFHxA PFAS by ID 12 ng/L 5
001 Effluent Aqueous PFOA PFAS by ID 15 ng/L 5
001 Effluent Aqueous PFPeA PFAS by ID 13 ng/L 5
001 Effluent Aqueous PFOS PFAS by ID 17 ng/L 5
(8 detections)
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 14 of 30
Page 4 of 20
PFAS by LC/MS/MS
Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-001
Description:Effluent Matrix:Aqueous
Date Sampled:01/21/2021 1145 Project Name:Savannah Wood
Date Received:01/23/2021 Project Number:92517799
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 SOP SPE PFAS by ID SOP 1 01/28/2021 1547 JJG 01/27/2021 1043 80843
CAS Analytical
Parameter Number Method Result Q LOQ Units Run
9-chlorohexadecafluoro-3-oxanone-1-sulfonic acid(9CI-PF3ONS) 756426-58-1 PFAS by ID SOP ND 7.4 ng/L 1
11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid(11CI-PF3...) 763051-92-9 PFAS by ID SOP ND 7.4 ng/L 1
1H,1H,2H,2H-perfluorodecane sulfonic acid(8:2 FTS) 39108-34-4 PFAS by ID SOP ND 7.4 ng/L 1
1H,1H,2H,2H-perfluorooctane sulfonic acid(6:2 FTS) 27619-97-2 PFAS by ID SOP ND 7.4 ng/L 1
1H,1H,2H,2H-perfluorododecane sulfonic acid(10:2 FTS) 120226-60-0 PFAS by ID SOP ND 7.4 ng/L 1
1H,1H,2H,2H-perfluorohexane sulfonic acid(4:2 FTS) 757124-72-4 PFAS by ID SOP ND 7.4 ng/L 1
Hexafluoropropylene oxide dimer acid(GenX) 13252-13-6 PFAS by ID SOP ND 7.4 ng/L 1
4,8-dioxa-3H-perfluorononanoic acid(ADONA) 919005-14-4 PFAS by ID SOP ND 7.4 ng/L 1
N-ethylperfluoro-1-octanesulfonamide(EtFOSA) 4151-50-2 PFAS by ID SOP ND 7.4 nglL 1
N-ethylperfluoro-l-octanesulfonamidoacetic acid(EtFOSAA) 2991-50-6 PFAS by ID SOP ND 7.4 ng/L 1
2-N-ethylperfluoro-1-octanesulfonamido-ethanol(EtFOSE) 1691-99-2 PFAS by ID SOP ND 7.4 ng/L 1
N-methylperfluoro-l-octanesulfonamide(MeFOSA) 31506-32-8 PFAS by ID SOP ND 15 ng/L 1
N-methylperfluoro-1-octanesulfonamidoacetic acid(MeFOSAA) 2355-31-9 PFAS by ID SOP ND 7.4 ng/L 1
2-N-methylperfluoro-1-octanesulfonamido-ethanol(MeFOSE) 24448-09-7 PFAS by ID SOP ND 7.4 ng/L 1
Perfluoro-1-butanesulfonic acid(PFBS) 375-73-5 PFAS by ID SOP 7.1 3.7 ng/L 1
Perfluoro-l-decanesulfonic acid(PFDS) 335-77-3 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-l-heptanesulfonic acid(PFHpS) 375-92-8 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-l-nonanesulfonic acid(PFNS) 68259-12-1 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-1-octanesulfonamide(PEOSA) 754-91-6 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-1-pentanesulfonic acid(PFPeS) 2706-91-4 PFAS by ID SOP ND 3.7 ng/L 1
Perfluorododecanesulfonic acid(PFDOS) 79780-39-5 PFAS by ID SOP ND 7.4 ng/L 1
Perfluorohexanesulfonic acid(PFHxS) 355-46-4 PFAS by ID SOP 5.9 3.7 ng/L 1
Perfiuoro-n-butanoic acid(PFBA) 375-22-4 PFAS by ID SOP 9.6 3.7 ng/L 1
Perfluoro-n-decanoic acid(PFDA) 335-76-2 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-n-dodecanoic acid(PFDoA) 307-55-1 PFAS by ID SOP ND 3.7 ng/L 1
Perfiuoro-n-heptanoic acid(PFHpA) 375-85-9 PFAS by ID SOP 6.4 3.7 ng/L 1
Perfluoro-n-hexadecanoic acid(PFHxDA) 67905-19-5 PFAS by ID SOP ND 7.4 ng/L 1
Perfluoro-n-hexanoic acid(PFHxA) 307-24-4 PFAS by ID SOP 12 3.7 nglL 1
Perfluoro-n-nonanoic acid(PFNA) 375-95-1 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-n-octadecanoic acid(PFODA) 16517-11-6 PFAS by ID SOP ND 7.4 ng/L 1
Perfluoro-n-octanoic acid(PFOA) 335-67-1 PFAS by ID SOP 15 3.7 ng/L 1
Perfiuoro-n-pentanolc acid(PFPeA) 2706-90-3 PFAS by ID SOP 13 3.7 ng/L 1
Perfluoro-n-tetradecanoic acid(PFTeDA) 376-06-7 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-n-tridecanoic acid(PFTrDA) 72629-94-8 PFAS by ID SOP ND 3.7 ng/L 1
Perfluoro-n-undecanoic acid(PFUdA) 2058-94-8 PFAS by ID SOP ND 3.7 ng/L 1
Perfluorooctanesulfonic acid(PFOS) 1763-23-1 PFAS by ID SOP 17 3.7 ng!L 1
Run 1 Acceptance
Surrogate Q %Recovery Limits
13C2_4:2FTS 143 25-150
13C2 6:2FTS 121 25-150
13C2_8:2FTS 95 25-150
13C2 PFDoA 76 25-150
13C2 PFHxDA 37 25-150
13C2 PFTeDA 49 25-150
LOQ=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range
ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40%
H=Out of holding time W=Reported on wet weight basis
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 15 of 30
Page 5 of 20
PFAS by LC/MS/MS
Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-001
Description:Effluent Matrix:Aqueous
Date Sampled:01/21/2021 1145 Project Name:Savannah Wood
Date Received:01/2312021 Project Number:92517799
Run 1 Acceptance
Surrogate Q %Recovery Limits
13C3_PFBS 94 25-150
13C3_PFHxS 88 25-150
13C3-HFPO-DA 102 25-150
13C4_PFBA 58 25-150
13C4_PFHpA 111 25-150
13C5_PFHxA 106 25-150
13C5_PFPeA 99 25-150
13C6_PFDA 91 25-150
13C7_PFUdA 85 25-150
13C8_PFOA 95 25-150
13C8_PFOS 75 25-150
13C8_PFOSA 99 10-150
13C9_PFNA 95 25-150
d-EtFOSA 76 10-150
d5-EtFOSAA 85 25-150
d9-EtFOSE 78 10-150
d-MeFOSA 91 10-150
d3-MeFOSAA 99 25-150
d7-MeFOSE 87 10-150
LOQ=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range
ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40%
H=Out of holding time W=Reported on wet weight basis
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 16 of 30
Page 6 of 20
PFAS by LC/MS/MS
Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-002
Description:Field Blank Matrix:Aqueous
Date Sampled:01/21/2021 1140 Project Name:Savannah Wood
Date Received:01/23/2021 Project Number:92517799
Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch
1 SOP SPE PFAS by ID SOP 1 01/28/2021 1536 JJG 01/27/2021 1043 80843
CAS Analytical
Parameter Number Method Result Q LOQ Units Run
9-chlorohexadecafluoro-3-oxanone-1-sulfonic acid(9CI-PF3ONS) 756426-58-1 PFAS by ID SOP ND 7.9 ng/L 1
11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid(11CI-PF3...) 763051-92-9 PFAS by ID SOP ND 7.9 ng/L 1
1H,1H,2H,2H-perfluorodecane sulfonic acid(8:2 FTS) 39108-34-4 PFAS by ID SOP ND 7.9 ng/L 1
1H,1H,2H,2H-perfluorooctane sulfonic acid(6:2 FTS) 27619-97-2 PFAS by ID SOP ND 7.9 ng/L 1
1 H,1 H,2H,2H-perfluorododecane sulfonic acid(10:2 FTS) 120226-60-0 PFAS by ID SOP ND 7.9 ng/L 1
1H,1H,2H,2H-perfluorohexane sulfonic acid(4:2 FTS) 757124-72-4 PFAS by ID SOP ND 7.9 ng/L 1
Hexafluoropropylene oxide dimer acid(GenX) 13252-13-6 PFAS by ID SOP ND 7.9 ng/L 1
4,8-dioxa-3H-perfluorononanoic acid(ADONA) 919005-14-4 PFAS by ID SOP ND 7.9 ng/L 1
N-ethylperfluoro-1-octanesulfonamide(EtFOSA) 4151-50-2 PFAS by ID SOP ND 7.9 ng/L 1
N-ethylperfluoro-1-octanesulfonamidoacetic acid(EtFOSAA) 2991-50-6 PFAS by ID SOP ND 7.9 ng/L 1
2-N-ethylperfluoro-1-octanesulfonamido-ethanol(EtFOSE) 1691-99-2 PFAS by ID SOP ND 7.9 ng/L 1
N-methylperfluoro-1-octanesulfonamide(MeFOSA) 31506-32-8 PFAS by ID SOP ND 16 ng/L 1
N-methylperfluoro-1-octanesulfonamidoacetic acid(MeFOSAA) 2355-31-9 PFAS by ID SOP ND 7.9 ng/L 1
2-N-methylperfluoro-1-octanesulfonamido-ethanol(MeFOSE) 24448-09-7 PFAS by ID SOP ND 7.9 ng/L 1
Perfluoro-1-butanesulfonic acid(PFBS) 375-73-5 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-1-decanesulfonic acid(PFDS) 335-77-3 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-1-heptanesulfonic acid(PFHpS) 375-92-8 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro=l-nonanesulfonic acid(PFNS) 68259-12-1 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-1-octanesulfonamide(PFOSA) 754-91-6 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-1-pentanesulfonic acid(PFPeS) 2706-91-4 PFAS by ID SOP ND 4.0 ng/L 1
Perfluorododecanesulfonic acid(PFDOS) 79780-39-5 PFAS by ID SOP ND 7.9 ng/L 1
Perfluorohexanesulfonic acid(PFHxS) 355-46-4 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-n-butanoic acid(PFBA) 375-22-4 PFAS by ID SOP ND 4.0 ng/L 1
1 Perfluoro-n-decanoic acid(PFDA) 335-76-2 PFAS byID SOP ND 4.0 ng/L 1
9
Perfluoro-n-dodecanoic acid(PFDoA) 307-55-1 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-n-heptanoic acid(PFHpA) 375-85-9 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-n-hexadecanoic acid(PFHxDA) 67905-19-5 PFAS by ID SOP ND 7.9 ng/L 1
Perfluoro-n-hexanoic acid(PFHxA) 307-24-4 PFAS byID SOP ND 4.0 ng/L 1
9
Perfluoro-n-nonanoic acid(PFNA) 375-95-1 PFAS by ID SOP ND 4.0 ng/L 1
Perfiuoro-n-octadecanoic acid(PFODA) 16517-11-6 PFAS by ID SOP ND 7.9 ng/L 1
Perfluoro-n-octanoic acid(PFOA) 335-67-1 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-n-pentanoic acid(PFPeA) 2706-90-3 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-n-tetradecanoic acid(PFTeDA) 376-06-7 PFAS by ID SOP ND 4.0 ng/L 1
-Perfluoro-n-tridecanoic acid(PFTrDA) 72629-94-8 PFAS by ID SOP ND 4.0 ng/L 1
Perfluoro-n-undecanoic acid(PFUdA) 2058-94-8 PFAS by ID SOP ND 4.0 ng/L 1
Perfluorooctanesulfonic acid(PFOS) 1763-23-1 PFAS by ID SOP ND 4.0 ng/L 1
Run 1 Acceptance
Surrogate Q %Recovery Limits
13C2_4:2FTS 115 25-150
13C2 6:2FTS 109 25-150
13C2 8:2FTS 111 25-150
13C2 PFDoA 103 25-150
13C2 PFHxDA 35 25-150
13C2 PFTeDA 52 25-150
LOQ=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range
ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40%
H=Out of holding time W=Reported on wet weight basis
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 17 of 30
Page 7 of 20
PFAS by LC/MS/MS
Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-002
Description:Field Blank Matrix:Aqueous
Date Sampled:01/21/2021 1140 Project Name:Savannah Wood
Date Received:01/23/2021 Project Number:92517799
Run 1 Acceptance
Surrogate Q %Recovery Limits
13C3 PFBS 101 25-150
13C3_PFHxS 103 25-150
13C3-HFPO-DA 107 25-150
13C4 PFBA 106 25-150
13C4_PFHpA 119 25-150
13C5_PFHxA 109 25-150
13C5_PFPeA 107 25-150
13C6 PFDA 101 25-150
13C7_PFUdA 104 25-150
13C8_PFOA 108 25-150
13C8_PFOS 102 25-150
13C8_P FOSA 107 10-150
13C9_PFNA 103 25-150
d-EtFOSA 89 10-150
d5-EtFOSAA 104 25-150
d9-EtFOSE 122 10-150
d-MeFOSA 94 10-150
d3-MeFOSAA 108 25-150
d7-MeFOSE 109 10-150
LOG=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range
ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40%
H=Out of holding time W=Reported on wet weight basis
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 18 of 30
Page 8 of 20
QC Summary
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 19 of 30
Page 9 of 20
PFAS by LC/MS/MS - MB
Sample ID:W080843-001 Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Parameter Result Q Dil LOQ Units Analysis Date
9CI-PF3ONS ND 1 8.0 ng/L 01/28/2021 1400
11CI-PF3OUdS ND 1 8.0 ng/L 01/28/2021 1400
8:2 FTS ND 1 8.0 ng/L 01/28/2021 1400
6:2 FTS ND 1 8.0 ng/L 01/28/2021 1400
10:2 FTS ND 1 8.0 ng/L 01/28/2021 1400
4:2 FTS ND 1 8.0 ng/L 01/28/2021 1400
GenX ND 1 8.0 ng/L 01/28/2021 1400
ADONA ND 1 8.0 ng/L 01/28/2021 1400
EtFOSA ND 1 8.0 ng/L 01/28/2021 1400 I
EtFOSAA ND 1 8.0 ng/L 01/28/2021 1400
EtFOSE ND 1 8.0 ng/L 01/28/2021 1400
MeFOSA ND 1 16 ng/L 01/28/2021 1400
MeFOSAA ND 1 8.0 ng/L 01/28/2021 1400
MeFOSE ND 1 8.0 ng/L 01/28/2021 1400
PFBS ND 1 4.0 ng/L 01/28/2021 1400
PFDS ND 1 4.0 ng/L 01/28/2021 1400
PFHpS ND 1 4.0 ng/L 01/28/2021 1400
PFNS ND 1 4.0 ng/L 01/28/2021 1400
PFOSA ND 1 4.0 ng/L 01/28/2021 1400
PFPeS ND 1 4.0 ng/L 01/28/2021 1400
PFDOS ND 1 8.0 ng/L 01/28/2021 1400
PFHxS ND 1 4.0 ng/L 01/28/2021 1400
PFBA ND 1 4.0 ng/L 01/28/2021 1400
PFDA ND 1 4.0 ng/L 01/28/2021 1400
PFDoA ND 1 4.0 ng/L 01/28/2021 1400
PFHpA ND 1 4.0 ng/L 01/28/2021 1400
PFHxDA ND 1 8.0 ng/L 01/28/2021 1400
PFHxA ND 1 4.0 ng/L 01/28/2021 1400
PFNA ND 1 4.0 ng/L 01/28/2021 1400
PFODA ND 1 8.0 ng/L 01/28/2021 1400
PFOA ND 1 4.0 ng/L 01/28/2021 1400
PFPeA ND 1 4.0 ng/L 01/28/2021 1400
PFTeDA ND 1 4.0 ng/L 01/28/2021 1400
PFTrDA ND 1 4.0 ng/L 01/28/2021 1400
PFUdA ND 1 4.0 ng/L 01/28/2021 1400
PFOS ND 1 4.0 ng/L 01/28/2021 1400
Acceptance
Surrogate Q %Rec Limit
- 13C2_4:2FTS 110 25-150
13C2 6:2FTS 108 25-150
13C2_8:2FTS 108 25-150
13C2 PFDoA 100 25-150
13C2_PFHxDA 106 25-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
'=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 20 of 30
Page 10 of 20
PFAS by LC/MS/MS - MB
Sample ID:WQ80843-001 Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Acceptance
Surrogate Q %Rec Limit
13C2_PFTeDA 102 25-150
13C3_PFBS 97 25-150
13C3_PFHxS 95 25-150
13C3-HFPO-DA 104 25-150
13C4_PFBA 103 25-150
13C4_PFHpA 119 25-150
13C5 PFHxA 103 25-150
13C5_PFPeA 103 25-150
13C6_PFDA 99 25-150
13C7_PFUdA 99 25-150
13C8_PFOA 106 25-150
13C8 PFOS 92 25-150
13C8_PFOSA 102 10-150
13C9_PFNA 101 25-150
d-EtFOSA 98 10-150
d5-EtFOSAA 100 25-150
d9-EtFOSE 123 10-150
d-MeFOSA 106 10-150
d3-MeFOSAA 103 25-150
d7-MeFOSE 116 10-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 21 of 30
Page 11 of 20
PFAS by LC/MS/MS - LCS
Sample ID:WQ80843-002 Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Spike
Amount Result %Rec
Parameter (nglL) (ng/L) Q Dil %Rec Limit Analysis Date
9C1-PF3ONS 15 15 1 99 50-150 01/29/2021 1506
11CI-PF3OUdS 15 15 1 97 50-150 01/29/2021 1506
8:2 FTS 15 15 1 97 50-150 01/29/2021 1506
6:2 FTS 15 21 1 138 50-150 01/29/2021 1506
10:2 FTS 15 15 1 96 50-150 01/29/2021 1506
4:2 FTS 15 14 1 97 50-150 01/29/2021 1506
GenX 32 34 1 106 50-150 01/29/2021 1506
ADONA 15 16 1 104 50-150 01/29/2021 1506
EtFOSA 16 17 1 107 50-150 01/29/2021 1506
EtFOSAA 16 16 1 99 50-150 01/29/2021 1506
EtFOSE 16 16 1 99 50-150 01/29/2021 1506
MeFOSA 16 16 1 98 50-150 01/29/2021 1506
MeFOSAA 16 15 1 95 50-150 01/29/2021 1506
MeFOSE 16 17 1 104 50-150 01/29/2021 1506
PFBS 14 13 1 95 50-150 01/29/2021 1506
PFDS 15 15 1 97 50-150 01/29/2021 1506
PFHpS 15 16 1 107 50-150 01/29/2021 1506
PFNS 15 15 1 94 50-150 01/29/2021 1506
PFOSA 16 16 1 100 50-150 01/29/2021 1506
PFPeS 15 16 1 109 50-150 01/29/2021 1506
PFDOS 15 15 1 96 50-150 01/29/2021 1506
PFHxS 15 14 1 96 50-150 01/29/2021 1506
PFBA 16 17 1 103 50-150 01/29/2021 1506
PFDA 16 16 1 98 50-150 01/29/2021 1506
PFDoA 16 16 1 101 50-150 01/29/2021 1506
PFHpA 16 17 1 104 50-150 01/29/2021 1506
PFHxDA 16 16 1 102 50-150 01/29/2021 1506
PFHxA 16 16 1 102 50-150 01/29/2021 1506
PFNA 16 16 1 99 50-150 01/29/2021 1506
PFODA 16 15 1 97 50-150 01/29/2021 1506
PFOA 16 16 1 99 50-150 01/29/2021 1506
PFPeA 16 16 1 102 50-150 01/29/2021 1506
PFTeDA 16 16 1 100 50-150 01/29/2021 1506
PFTrDA 16 17 1 108 50-150 01/29/2021 1506
PFUdA 16 17 1 104 50-150 01/29/2021 1506
PFOS 15 14 1 92 50-150 01/29/2021 1506
Acceptance
Surrogate Q %Rec Limit
13C2_4:2FTS 98 25-150
-I" 13C2_6:2FTS 102 25-150
13C2_8:2FTS 88 25-150
13C2_PFDoA 95 25-150
13C2_PFHxDA 97 25-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
•=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 22 of 30
Page 12 of 20
PFAS by LC/MS/MS - LCS
Sample ID:WQ80843-002 Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Acceptance
Surrogate Q %Rec Limit
13C2_PFTeDA 93 25-150
13C3_PFBS 89 25-150
13C3_PFHxS 92 25-150
13C3-HFPO-DA 98 25-150
13C4_PFBA 98 25-150
13C4_PFHpA 100 25-150
13C5_PFHxA 99 25-150
13C5_PFPeA 99 25-150
13C6_PFDA 100 25-150
13C7_PFUdA 90 25-150
13C8_PFOA 95 25-150
13C8_PFOS 90 25-150
13C8_PFOSA 97 10-150
13C9_PFNA 99 25-150
d-EtFOSA 88 10-150
d5-EtFOSAA 93 25-150
d9-EtFOSE 94 10-150
d-MeFOSA 80 10-150
d3-MeFOSAA 94 25-150
d7-MeFOSE 97 10-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
•=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 23 of 30
Page 13 of 20
11
PFAS by LC/MS/MS - MS
Sample ID:WA23002-001MS Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Sample Spike
Amount Amount Result %Rec
Parameter (ng/L) (ng/L) (ng/L) Q Dil %Rec Limit Analysis Date
9C1-PF3ONS ND 14 11 1 79 50-150 01/28/2021 1558
11CI-PF3OUdS ND 14 8.4 1 61 50-150 01/28/2021 1558
8:2 FTS ND 14 15 1 109 50-150 01/28/2021 1558
6:2 FTS ND 14 13 1 93 50-150 01/28/2021 1558
10:2 FTS ND 14 12 1 83 50-150 01/28/2021 1558
4:2 FTS ND 14 12 1 88 50-150 01/28/2021 1558
GenX ND 29 28 1 96 50-150 01/28/2021 1558
ADONA ND 14 14 1 101 50-150 01/28/2021 1558
EtFOSA ND 15 12 1 85 50-150 01/28/2021 1558
EtFOSAA ND 15 13 1 86 50-150 01/28/2021 1558
EtFOSE ND 15 12 1 79 50-150 01/28/2021 1558
MeFOSA ND 15 14 1 94 50-150 01/28/2021 1558
MeFOSAA ND 15 12 1 82 50-150 01/28/2021 1558
MeFOSE ND 15 12 1 83 50-150 01/28/2021 1558
PFBS 7.1 13 18 1 82 50-150 01/28/2021 1558
PFDS ND 14 10 1 72 50-150 01/28/2021 1558
PFHpS ND 14 13 1 93 50-150 01/28/2021 1558
PFNS ND 14 12 1 85 50-150 01/28/2021 1558
PFOSA ND 15 14 1 93 50-150 01/28/2021 1558
PFPeS ND 14 15 1 110 50-150 01/28/2021 1558
PFDOS ND 14 6.5 N 1 46 50-150 01/28/2021 1558
PFHxS 5.9 13 17 1 85 50-150 01/28/2021 1558
PFBA 9.6 15 22 1 86 50-150 01/28/2021 1558
PFDA ND 15 14 1 98 50-150 01/28/2021 1558
PFDoA ND 15 13 1 88 50-150 01/28/2021 1558
PFHpA 6.4 15 19 1 89 50-150 01/28/2021 1558
PFHxDA ND 15 14 1 96 50-150 01/28/2021 1558
PFHxA 12 15 25 1 91 50-150 01/28/2021 1558
PFNA ND 15 15 1 100 50-150 01/28/2021 1558
PFODA ND 15 11 1 76 50-150 01/28/2021 1558
PFOA 15 15 27 1 82 50-150 01/28/2021 1558
PFPeA 13 15 25 1 83 50-150 01/28/2021 1558
PFTeDA ND 15 14 1 92 50-150 01/28/2021 1558
PFTrDA ND 15 12 1 81 50-150 01/28/2021 1558
PFUdA ND 15 13 1 92 50-150 01/28/2021 1558
PFOS 17 14 29 1 90 50-150 01/28/2021 1558
Acceptance
Surrogate Q %Rec Limit
13C2_4:2FTS 138 25-150
_ 13C2_6:2FTS 113 25-150
13C2_8:2FTS 95 25-150
13C2 PFDoA 83 25-150
13C2_PFHxDA 44 25-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
•=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 24 of 30
Page 14 of 20
PFAS by LC/MS/MS - MS
Sample ID:WA23002-001MS Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Acceptance
Surrogate Q %Rec Limit
13C2_PFTeDA 55 25-150
13C3_PFBS 91 25-150
13C3_PFHxS 85 25-150
13C3-HFPO-DA 97 25-150
13C4_PFBA 58 25-150
13C4_PFHpA 101 25-150
13C5_PFHxA 100 25-150
13C5_PFPeA 93 25-150
13C6 PFDA 88 25-150
13C7_PFUdA 87 25-150
13C8_PFOA 92 25-150
13C8_PFOS 84 25-150
13C8_PFOSA 99 10-150
13C9_PFNA 92 25-150
d-EtFOSA 82 10-150
d5-EtFOSAA 92 25-150
d9-EtFOSE 83 10-150
d-MeFOSA 87 10-150
d3-MeFOSAA 96 25-150
d7-MeFOSE 87 10-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOG N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 25 of 30
Page 15 of 20
PFAS by LC/MS/MS - MSD
Sample ID:WA23002-001 MD Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Sample Spike
Amount Amount Result %Rec %RPD
Parameter (ng/L) (ng/L) (ng/L) Q Dil %Rec %RPD Limit Limit Analysis Date
9C1-PF3ONS ND 14 10 1 76 3.1 50-150 30 01/28/2021 1608
11CI-PF3OUdS ND 14 8.0 1 57 4.9 50-150 30 01/28/2021 1608
8:2 FTS ND 14 16 1 111 2.9 50-150 30 01/28/2021 1608
6:2 FTS ND 14 17 1 118 25 50-150 30 01/28/2021 1608
10:2 FTS ND 14 11 1 77 6.2 50-150 30 01/28/2021 1608
4:2 FTS ND 14 12 1 89 2.5 50-150 30 01/28/2021 1608
GenX ND 30 28 1 94 0.59 50-150 30 01/28/2021 1608
ADONA ND 14 14 1 99 1.4 50-150 30 01/28/2021 1608
EtFOSA ND 15 15 1 99 18 50-150 30 01/28/2021 1608
EtFOSAA ND 15 14 1 94 9.9 50-150 30 01/28/2021 1608
EtFOSE ND 15 14 1 94 19 50-150 30 01/28/2021 1608
MeFOSA ND 15 14 1 96 4.0 50-150 30 01/28/2021 1608
MeFOSAA ND 15 13 1 90 10 50-150 30 01/28/2021 1608
MeFOSE ND 15 14 1 91 11 50-150 30 01/28/2021 1608
PFBS 7.1 13 20 1 97 11 50-150 30 01/28/2021 1608
PFDS ND 14 11 1 74 4.7 50-150 30 01/28/2021 1608
PFHpS ND 14 12 1 86 6.6 50-150 30 01/28/2021 1608
PFNS ND 14 12 1 83 1.1 50-150 30 01/28/2021 1608
PFOSA ND 15 13 1 89 3.1 50-150 30 01/28/2021 1608
PFPeS ND 14 16 1 113 4.3 50-150 30 01/28/2021 1608
PFDOS ND 14 5.8 N 1 40 11 50-150 30 01/28/2021 1608
PFHxS 5.9 14 18 1 88 3.9 50-150 30 01/28/2021 1608
PFBA 9.6 15 23 1 92 4.4 50-150 30 01/28/2021 1608
PFDA ND 15 15 1 101 4.0 50-150 30 01/28/2021 1608
PFDoA ND 15 14 1 94 7.5 50-150 30 01/28/2021 1608
PFHpA 6.4 15 19 1 84 2.7 50-150 30 01/28/2021 1608
PFHxDA ND 15 14 1 95 1.1 50-150 30 01/28/2021 1608
PFHxA 12 15 29 1 112 12 50-150 30 01/28/2021 1608
PFNA ND 15 16 1 110 11 50-150 30 01/28/2021 1608
PFODA ND 15 10 1 69 9.1 50-150 30 01/28/2021 1608
PFOA 15 15 27 1 85 2.2 50-150 30 01/28/2021 1608
PFPeA 13 15 27 1 92 6.0 50-150 30 01/28/2021 1608
PFTeDA ND 15 14 1 93 2.0 50-150 30 01/28/2021 1608
PFTrDA ND 15 12 1 82 3.1 50-150 30 01/28/2021 1608
PFUdA ND 15 14 1 94 3.8 50-150 30 01/28/2021 1608
PFOS 17 14 28 1 82 3.4 50-150 30 01/28/2021 1608
Acceptance
Surrogate Q %Rec Limit
13C2_4:2FTS 145 25-150
13C2_6:2FTS 109 25-150
13C2_8:2FTS 99 25-150
13C2_PFDoA 74 25-150
13C2_PFHxDA 35 25-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
•=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 26 of 30
Page 16 of 20
PFAS by LC/MS/MS - MSD
Sample ID:WA23002-001MD Matrix: Aqueous
Batch:80843 Prep Method: SOP SPE
Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043
Acceptance
Surrogate Q %Rec Limit
13C2_PFTeDA 47 25-150
13C3_PFBS 88 25-150
13C3_PFHxS 88 25-150
13C3-HFPO-DA 97 25-150
13C4_PFBA 56 25-150
13C4_PFHpA 114 25-150
13C5_PFHxA 95 25-150
13C5_PFPeA 93 25-150
13C6_PFDA 89 25-150
13C7_PFUdA 86 25-150
13C8_PFOA 94 25-150
13C8_PFOS 71 25-150
13C8_PFOSA 99 10-150
13C9 PFNA 90 25-150
d-EtFOSA 83 10-150
d5-EtFOSAA 86 25-150
d9-EtFOSE 77 10-150
d-MeFOSA 88 10-150
d3-MeFOSAA 90 25-150
d7-MeFOSE 88 10-150
LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria
P=The RPD between two GC columns exceeds 40%
•=RSD is out of criteria +=RPD is out of criteria
Note: Calculations are performed before rounding to avoid round-off errors in calculated results
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 27 of 30
Page 17 of 20
Chain of Custody
and
Miscellaneous Documents
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 28 of 30
Page 18 of 20
7
O
co
0
N
0
m
Li
.
L Jo 1..IV d 890Z43ieNSZ OO'tii'Luu-J-TIV-.Li S';;'$L=So-JL LLOZ'ZZrJ5tw1;^':;�_n,1
U
_J
I .
CO I -
t 70:.kraiuqui/AUNO all(ul nirmJtnn:?sr co-yxwiotr,7 soca apart or 5•..7;JoiL1wou pe.vr.NSUC2 S l,POJSan:O'ir ,7'd..u.
E
W -iti top;JU:�-S?U/uo QapinoJd aq Jou XSa ' irl0ii.fa r:p:i,'r araou s,..,9jJt,L/_, 'arts Su,•�dua3s ar,110 u--)u/u�ri ooJ )ig.nu,p;J,ra iu l j,-r Lu 3:0-y.,U. ,-apjv ui,,.,, 8
U1 7_ IUL S31tltu'er� ,-.. ..M a"3j "Ji:nia�e /'� 1... JD
-._. • .T�....._...-..._, ,-L.__---... '- __ i1 1, lea hpa33ii3 I 3, Y` iJi yea un airlis aclula/Ial64j1
Ce
• .,w4li•1 .cc,panic ti r - as
-
ae5-.., .w,J,alepi� AA Pas*+ »i� :.Lalsucll,
[ I I] ,-,-,-. 0,
I t on
- I : I �E X 17 i 4_,j L r mR/�h; 6OCEZ.U.lSZ6I 6k•lt LT.oZILieL- Sd�_ _»•- yorca0m,i ri� _ 1 °
J 1 �,�,�,I i 1 I ?�I }( � I i I 1 L ' -AImiJ.I LOCO[i!/L,iSj 5v:lt LEUZ/Lf1L ^i.-Li I I'W2•1 2 O
Q .1hNO E3ri v iI r i € -- "--b i --. .•.�: 4'. :•: �r j ,•. �— ° or
Z 1 ! Hi-:.:-.4'".2.":4
1 '4FWil'1. - .,y -Crt,;1-I• .aii(ilaLF:SI ;:A.I, .y:._. •- �:il4uia L:A_i1•
Q 1i s 1 i }11 e1 '.� {a: th lti- rlc asj•13 ti -- ; Y,�•
W i zc.a i 1 . 1 i l�•:�lr`ltdr.O-S.?^'7'�g.:; _A E w
U yI
4 r
1 ZiooCCiVM t • , f
1 ii ! s
i E aseE �� .�L}5L 7lJ�l t:�
J 1 O:L6-I.6L:c_'4B7 3CL71ar af.i19Z :IN'alllrsialunl I
t6Z :.,S'aWu illo 3 i M COL a1r�3 •ItAV Aaaui>l��OSG a, E
4 g anud 11-4,1 O 1;t:/h 3'JL •9UarI U 1�=iL��trl�aa3� E o
: i i 3g Y ZL 1 r.muLrq,i:.Ls2.M i•einAl2u v aa^.j srlool- ,,.;iiA I • o U
r..,: ,:-i4_ ':,, ..-.$I: Guy p::::3.tUeZ;.. `-s.-. 1, .. M1waw.wgsyn�.�g .- '?l E.telfi�i.
I LZOZ1bie :F-2 .' a i�r.bey$linsau 1.,3ZILZit :tYra Fe%s-•s:i-�. ?or,,,
Jou/A° •,gauuen :g; aiLls•.' -)!oy{raivi f6v.,,i;76 'JaP- i-Sam -
i I zie pi SSA : ,:e�sa �a� 8 ;
;jrJ•..;Li L L peelx-- Jd se,du:eS 0
! .._..M�._. .. ... .4,0°,1';sno to 7.Tego. .162_suf a. :i;3Ei.iew ° LL
sm
. Q �
U .p
O
! tit'
PACE ANALYTICAL SERVICES, LLC
� Samples Receipt Checklist(SRC}{M60018C-15} i+Y JI;j /29/202D
911
/' .Pacerraly'tiaai :suingAuthority:PaceENV-WOOL \A23002 4ge1of1
Sample Receipt Checklist cklist SR )
� �f KLe'e
Clierd:` Cooler Inspected by elate: �-' /j c' r-1 r.nl A
Means of rceeipC-,El Pace ❑Client ❑UPS E-edt:x (_(Other:
Yes aNc F,I.Were custody seals present on the cooler"
Yes iNo Ell A.. If cus.tndy seals were present,were they'ileac:and unbroken?
pH Strip ID: pal - Clllotine Strip ID:..._.__' G_. Tested by: t' -C._,
1 Original temperature upon leceilri l Derived(Corrected)temperature upon receipt %Solid Snap-Cup IC): _f 1
1-1, Svc-3''-.1 C'.._- v{. }flC,'•-•-Vic' YLt ` ,� I
Method:❑femperatl:re Black❑Against Bottles 1K(inn ID: �� Ik(ion Correction factor °C
Method of coolant: ❑Wct ice ❑ ice Packs ❑ Dry Ice ❑ None i
II-temperature of any cooler exceeded 5.0°C,was Project Manager Notified?
El Yes ❑No LJ NA PM was Notified by:phone i email/ fce.o-face(circle one).
EYE (i No 'NA 4. Is the commercial courier's packing slip attached to this fo-n?
—_
U Nu 5. Were proffer custody n:rieesLrres(reliny:ri.;hedireceivett)followed?
Du'rs f No 5. Wore sairple lLs lisxd on the COC?
❑Nn 7. Were sample Ins listed on all sample Containers?
❑No W � 8. Was collection date&time 1is rl on the COO?
II ❑No 9. Was collection date&time lined on all sample containers?
j. }Ycs ❑NU 110.Did all container lobe:information(ID,date,time)agree with the COC?
fl Yts ❑No 1:I. Were tests to be performed listed on the COC?
'2. Did all samples anive in the proper containers for each test andior:n good condition
ErYes ❑No,
(unbroken,.ids on,etc_)?
4YC . L..JNoli 13.Was adequate sample volume ava=labte?
es UNo: 14.Were all samples receivec within'A tlyi.....11kidst-M4 time or 48 hours,whichever comes first?
21es IJ Nal 15,Were any samples containers missidgxcess(elretc one)samp:es Not listed on COC?
l 1' 16,far VOA an:l RSK-175 samples,wer TTthles present>' ea-:iv,e"(/h"tr Cinlin in diameter)
❑A Yec ❑Nn ?in any of the VOA vial:;?
Yes LIND 17.Were all DROh sam
ples mples received at a pH of<2:'
Yes LI No W.T. I S.We:e ill cy-Lnido samples received at a i1-i>t2 in id S;11:I1.IC SUE:lnles received a:n pH>9?
❑Ycs ❑No " 19. Were all applicable NIG/TKNicyailde:pheyoI/623.1/i08.3 (<0.5mg,'L)samples tree a}'
A residual chlorine?
,
ID yes ,/ 20.Were client remarks/requests(i.e.requested dilutions,MS NISI)designations,etc...)
❑No � -NA correctly transcribed from the COD into.he comment section in LAMS?
RYca No 21. Was the quote r_urnbe.r listed on the container label?If yes,Quote
_ _ Sample Preservation (Ivlust he completed for any sarnplc(s)incorrectly presetti:12d or with headspace
— Samplc(s) _W-:' _______ were received incorrectty preserved and were adiusted accordingly
in sample rcccivtng with mL of circle one:H2SO4,HNO3,HCI,NaOH using SR t` }' ,
Time of pres.sel-vt L]on , If more then one prescvvulive is needed,please note in the comments below.
Sample(s) 'C!, were received with bdaules>6 mm in diameter,
Samples(s) 1'1 - were received wits'1 1W>0.5 mg/L(if#l9 'is no)end were
adjusted accordingly in sample receiving with sodium thiosulfate(N1•20;)with,Shealy ID: ,_(\ _ ,
SR barcode labels applied by; s Date: .�j� _t-'S'1- „), .----
?Comments: -ei,,-,'\v?.c\ .1 %') r ,;..,..4.?(\.:..;‘, .,.r\o,--Ve_e_ . „(._\ t'‘N
Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.)
106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com
Page 30 of 30
Page 20 of 20
A
*
Perfluoro-l-pentanesulfonic acid PFPeS 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluorododecanesulfonic acid PFDOS 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluorohexanesulfonic acid PFHxS 1/21/2021 5.9 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-butanoic acid PFBA 1/21/2021 9.6 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-decanoic acid PFDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-dodecanoic acid PFDoA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-heptanoic acid PFHpA 1/21/2021 6.4 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-hexadecanoic acid PFHxDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-hexanoic acid PFHxA 1/21/2021 12 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-nonanoic acid PFNA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluroro-n-octadecanoic acid PFODA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-octanoic acid PFOA 1/21/2021 15 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-pentanoic acid PFPeA 1/21/2021 13 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-tetradecanoic acid PFTeDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-tridecanoic acid PFTrDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluoro-n-undecanoic acid PFUdA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
Perfluorooctanesulfonic acid PFOS 1/21/2021 17 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear
1,4 Dioxane p-Dioxane 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear