Loading...
HomeMy WebLinkAboutNC0000892_Sampling Results_20210301 din Performance Applied RECEIVED MAR 01 2021 Arclin NCDEQIDWRINPDES 790 Corinth Road Moncure,NC 27559 February 19, 2021 NC Department of Environmental Quality Division of Water Resources Attn: Central Files 1617 Mail Service Center Raleigh,North Carolina 27699-1617 Re: January 21, 2021 PFAS Sampling Results Permit: NC0000892 Arclin USA,LLC Chatham County Class II Please find enclosed the PFAS Sampling Results Report for January 21, 2021,and the required PFAS Industrial Input Spreadsheet. This report is for the Arclin USA facility located at 790 Corinth Road, Moncure,North Carolina. If you have any questions,please contact Bowman Harvey at 919-545-5753. Sincerely, . Brian Reddy Arclin Plant Manager Pace Analytical Services,LLC aceAnalytical 6701 Conference Drive www.pacelalu.eom Raleigh,NC 27607 (919)834-4984 February 08, 2021 David Lorbacher Arclin-Dynea/Moncure 790 Corinth Road Chapel Hill, NC 27599 RE: Project: PFAS Pace Project No.: 92517799 Dear David Lorbacher: Enclosed are the analytical results for sample(s)received by the laboratory on January 21,2021. The results relate only to the samples included in this report. Analyses were performed at the Pace Analytical Services location indicated on the sample analyte page for analysis unless otherwise footnoted. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: •Pace Analytical Services-Charlotte If you have any questions concerning this report,please feel free to contact me. Sincerely, Tyriek Hooks tyriek.hooks@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Bowman Harvey,Acrlin-Dynea/Moncure Bowman Harvey,Arclin-Dynea/Moncure Chis Lamm,Arclin-Dynea/Moncure REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, without the written consent of Pace Analytical Services,LLC. Page 1 of 30 Pace Analytical Services,LLC ® www.pacelabs.cam 6701 Conference Drive Raleigh,NC 27607 aceAnalytical (919)834-4984 CERTIFICATIONS Project: PFAS Pace Project No.: 92517799 Pace Analytical Services Charlotte 9800 Kincey Ave.Ste 100,Huntersville,NC 28078 South Carolina Certification#:99006001 Louisiana/NELAP Certification#LA170028 Florida/NELAP Certification#:E87627 North Carolina Drinking Water Certification#:37706 Kentucky UST Certification#:84 North Carolina Field Services Certification#:5342 VirginiaNELAP Certification#:460221 North Carolina Wastewater Certification#:12 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, without the written consent of Pace Analytical Services,LLC. Page 2 of 30 Pace Analytical Services,LLC ace Analytical 6701 Conference Drive Raleigh,NC 27607 www.pacelabs.com (919)834-4984 SAMPLE ANALYTE COUNT Project: PFAS Pace Project No.: 92517799 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92517799003 Grab EPA 624 By SIM LMB 3 PASI-C PASI-C=Pace Analytical Services-Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, without the written consent of Pace Analytical Services,LLC. Page 3 of 30 Pace Analytical Services,LLC 6701 Conference Drive aceAnalytical www.pacelabs.com Raleigh,NC 27607 (919)834-4984 ANALYTICAL RESULTS Project: PFAS Pace Project No.: 92517799 Sample: Grab Lab ID: 92517799003 Collected: 01/21/21 11:50 Received: 01/21/21 12:45 Matrix:Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 624 Volatiles by SIM Analytical Method:EPA 624 By SIM Pace Analytical Services-Charlotte 1,4-Dioxane(p-Dioxane) ND ug/L 2.0 1 01/22/21 14:46 123-91-1 Surrogates Toluene-d8(S) 87 % 60-140 1 01/22/21 14:46 2037-26-5 1,2-Dichloroethane-d4(S) 87 % 60-140 1 01/22/21 14:46 17060-07-0 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 4 of 30 Pace Analytical Services,LLC aceAnalytical 670 ence Drive Raleigh,NC 27607 www.pacelabs.com (919)834-4984 QUALITY CONTROL DATA Project: PFAS Pace Project No.: 92517799 QC Batch: 594754 Analysis Method: EPA 624 By SIM QC Batch Method: EPA 624 By SIM Analysis Description: 624 MSV Volatiles by SIM Laboratory: Pace Analytical Services-Charlotte Associated Lab Samples: .92517799003 METHOD BLANK: 3137849 Matrix: Water Associated Lab Samples: 92517799003 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers 1,4-Dioxane(p-Dioxane) ug/L ND 2.0 01/22/21 11:36 1,2-Dichloroethane-d4(S) % 84 60-140 01/22/21 11:36 Toluene-d8(S) % 86 60-140 01/22/21 11:36 LABORATORY CONTROL SAMPLE: 3137850 Spike LCS LCS %Rec Parameter Units Conc. Result %Rec Limits Qualifiers 1,4-Dioxane(p-Dioxane) ug/L 20 19.3 97 60-140 1,2-Dichloroethane-d4(S) % 85 60-140 Toluene-d8(S) % 85 60-140 MATRIX SPIKE&MATRIX SPIKE DUPLICATE: 3137851 3137852 MS MSD 92517799003 Spike Spike MS MSD MS MSD %Rec Parameter Units Result Conc. Conc. Result Result %Rec %Rec Limits RPD Qual 1,4-Dioxane(p-Dioxane) ug/L ND 20 20 19.9 20.3 96 98 60-140 2 1,2-Dichloroethane-d4(S) % 82 83 60-140 Toluene-d8(S) % 82 81 60-140 Results presented on this page are In the units Indicated by the"Units"column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 5 of 30 Pace Analytical Services,LLC 6701 Conference Drive aceAnalytical Raleigh,NC 27607 www.pacelabs.ecm (919)834-4984 QUALIFIERS Project: PFAS Pace Project No.: 92517799 DEFINITIONS DF-Dilution Factor,if reported,represents the factor applied to the reported data due to dilution of the sample aliquot. ND-Not Detected at or above adjusted reporting limit. TNTC-Too Numerous To Count J-Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL-Adjusted Method Detection Limit. PQL-Practical Quantitation Limit. RL-Reporting Limit-The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S-Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270.The result for each analyte is a combined concentration. Consistent with EPA guidelines,unrounded data are displayed and have been used to calculate%recovery and RPD values. LCS(D)-Laboratory Control Sample(Duplicate) MS(D)-Matrix Spike(Duplicate) DUP-Sample Duplicate RPD-Relative Percent Difference NC-Not Calculable. SG-Silica Gel-Clean-Up U-Indicates the compound was analyzed for,but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 6 of 30 Pace Analytical Services,LLC ® 6701 Conference Drive aceAnal ical Raleigh,NC 27607 Yt 9 . www.pacelabs.com (919)834-4984 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: PFAS Pace Project No.: 92517799 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92517799003 Grab EPA 624 By SIM 594754 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full, Date:02/08/2021 12:21 PM without the written consent of Pace Analytical Services,LLC. Page 7 of 30 � I Document Name: Document Revised:October 28,2020 Sample Condition Upon Recelpt(SCUR) Page 1 of 2 aeeAnalytieal' Document No.: Issuing Authority: F-CAR-CS•033-Rev.07 Pace Carolinas quality Office Laboratory receiving samples: • Asheville❑ Eden❑ Greenwood❑ Huntersvi(le El Raleigh( ] Mechanicsville❑ Atlanta❑ KernersvilleEl SampleCon Condition Client Name-__ Project U: r W® r 92517799_ ____ °o teeit Courier: ['Fed Ex ❑UPS DUSPS ❑Cllent ( 111111 1111111111 0 Commercial Pace ['Other: 92517799 Custody Seal Present? Dyes No Seals Intact? Dyes QNo Date/Initials Person Examining Contents: ri/A-Z1-2./ Packing Material: ❑Bubble Wrap ['Bubble Bags ,None 0 Other Biological Tissue Frozen? Thermometer: ❑Yes ❑No jSdN/A ❑IR Gun ID: q1 7d0 T 5F4Wet ['Blue ONone ype of Ice: Correction Factor: Cooler Temp: �'v Add/Subtract(°C) Q. d Temp should be above freezing to 6°C ['Samples out of temp criteria.Samples on Ice,cooling process Cooler Temp Corrected('C): '7 - jj' hasbegun USDA Regulated Soil(�f N/A,water sample) It Did samples originate in a uarantine zone within the United States:CA,NY,or SC(check maps)? Did samples originate from a foreign source(Internationally, 1 ['Yes ❑No including Hawaii and Puerto Rico)?Oyes ❑No Comments/Discrepancy: Chain of Custody Present? I?'es Duo ON/A 1. Samples Arrived within Hold Time? ,+jYes ❑No IN/A 2, Short Hold Time Analysis(<72 hr.)? Dyes CjNo ON/A 3. Rush Turn Around Time Requested? DYes RN° ON/A 4, Sufficient Volume?. • j4Yes ❑Na ON/A 5. Correct Containers Used? ,Yes Duo ❑N/A 6, -Pace Containers Used? Yes Duo ON/A Containers Intact? gYes Duo ON/A 7. Dissolved analysis:Samples Field Filtered? Oyes Duo jjaN/A 8. Sample Labels Match COC? Dyes ❑No ❑N/A 9. • -Includes Date/Time/ID/Analysts Matrix: • Headspace in VOA Vials(>5-6mm)? Des ❑No ON/A 10. Trip Blank Present? :Yes ❑Na qN/A 11. I Trip Blank Custody Seals Present? []Yes ❑No WN/A COMMENTS/SAMPLE DISCREPANCY Field Data Required? Oyes ❑No i Lot ID of split containers: j ) CLIENT NOTIFICATION/RESOLUTION 1 � c . t : Person contacted: Date/Time: i i itProject Manager SCURF Review: Date: Project Manager SRF Review: Date: ? I I i # Page 8 of 30 I I Document Name: Document Revised:October 28,2020 i aceAnalyfical' Sample Condition Upon Receipt(SCUR) Page 2 of 2 • Document No.: Issuing Authority: F-CAR-CS•033-Rev,07 Pace Carolinas Quality Office "Check mark top half of box If pH and/or dechlorination is Project# i verified and within the acceptance range for preservation WO# : 92517799 samples. PM: TIN Due Date: 02/04/21 Exceptions;VOA,Coliform,TOC,Oil and Grease,DRO/8015(water)DOC,LLHg CLIENT: 91—Arcl 1nDyn Bottom half of box is to list number of bottles I �q,�q� is u b u a ^ Z Z j • V Y ? Q z z a .m Qi '^ z •N 'i • 4' 9 " ° E vv 4' iE. 2 CL\ 4 ` vZ - <v Za « a v = _ < < Ll a A .e ,,; " a a z I ' Z ? H '' 7 > > c 1,1 S z O v V = r� 2 Q ? O ? O t" Z 7 O c u Y u " L v a` 1. y a E x z O T Y Y m a �` . a a a A ro a ro o a E E .4 E '^ O < < < iv °' E c E a a a E � E ¢ ry O � �' ' J J J 6. J J � ¢ J ¢ J. > > � > N H J J J V7 < E E E y E E E E 6 v v E E r¢n E -' J 9 - -E E E J S n vs = Q1 0 m E E E E p E E rNa N .i N N ti �Ny .y r1 �ry ryN-�I N t O 4 I tV N Vat K( 2 O 2 bN U t07 M M ^ M Cn tp�� a' aw ~ -_,,� fxi 6 m m ' 0 gi X > X O # a a te7 ,his 2 1 1 \ \ j 2 \ \ 1-\\I ' . a \ \ 1 4 .\\ - \\ \\ , • I ' \ 7 \ \ , 8 \ \ 9 \ \ T 10 \ \ 1 • `• 11 \ 12 \ \\.\\ • • pH Adjustment Log for Preserved Samples Sample ID Type of Preservative_ pH upon receipt Date preservation adjusted Time preservation Amount of Preservative lot p adjusted added r• Note: Whenever there Is a discrepancy affecting North Carolina compliance samples,a copy of this form will be sent to the North Carolina DEHNR Certification Office(I.e. j ! Out of hold,incorrect preservative,out of temp,incorrect containers. i i 1 i 1i Page 9 of 30 PACE ANALYTICAL SERVICES, LLC aceAnalytical 106 Vantage Point Drive •West Columbia,SC 29172 Number L 1613 8 Telephone No.803-791-9700 Fax No.803-791-9111 www.pacelabs.com Client A Report to Contact Telephone o./E-mail Quote No. s'C-T �c�tlmck. �v9 (19)- `{$— G326) Address Sampler's S" t yj Analysis(Attach list it mom space is needed) `710 �ri( 'fo(• Page of City //�,�� (�/� S(ttattee1 Zip e Q X l Lot 0 Bar Code r -�on e.J..1 r ei 1 559 Printed Name (we use only) Project Name z!co(�c'. W x titoc� (,1� ?EA nN+ l A^ Project No. , . /� t PO.No. t Matrix No of Containers C° /Vt on -r 0 by Preservative Type 1 Sample ID/Dc\wription Collection Collection Time n 2 r 3 x Z 4$ (� r •y (Containers far each samara maybe combined on one Ana.) Dates) (IltiGrary) 7 z g 4 "`-' Remarks/Cooler LD• L S(�I! _IN tue.nk-- i141u 11:&t5 G % X oot Field jjcks-*- il2t 2t (1:440 2 X ®4z cab ( P2112t I(= 60 ' Li x 0.7 Turn Around Time Required(Prior lab approval resulted for expedited TAT.) Sample Disposal Possible Hazard Identification DC Requirements(Specify) 0 Standard u R h(Specify) 0 Return to Client El Disposal by Lab 0 Non-Hazard ElFlammable 0 Skin Irritant 0 Poison ❑Unknown i.RaJin ked fr&e€- Da Time i.Rocei by De a TAm i.off � 2 curt t�=y5 ,IZ i f 2 15 2.Relinquished by Dale Time 2. ecelvod by Date Time 3.Relinquished by Date Time 3.Received by Dale Time 4.Relinquished by Date Time 4.Laboratory received by Date Time Note:All samples are retained for four weeks from receipt LAB USE ONLY Term Blank D Y 0 N unless other arrangements are made. Received on ice(Circle) Yes No Ice Pack Receipt Temp.2 -46- 'C • -o co DISTRIBUTION:WHITE&YELLOW-Return to laboratory with Sampee(s);PINK-FieldfClient Copy Document Number:ME003N2.01 CD 0 0 C) ace Analytical Report of Analysis Pace Analytical Services, Inc. 9800 Kincey Avenue Suite 100 Huntersville, NC 28078 Attention: Tyriek Hooks Project Name: Savannah Wood Project Number: 92517799 Lot Number:WA23002 Date Completed:02/05/2021 02/05/2021 7:17 PM Approved and released by: Project Manager II: Karen L. Coonan s 'f; AliAB ANSI Nadm i/Accreditation Band .,. � ACCREDITED -1123133M-- TESTING LABORATORY The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced,except in its entirety,without the written approval of Pace Analytical Services, LLC. Pace Analytical Services, LLC(formerly Shealy Environmental Services, Inc.) 106 Vantage Point Drive West Columbia, SC 29172 Tel: 803-791-9700 Fax:803-791-9111 www.pacelabs.com Page 11 of 30 Page 1 of 20 PACE ANALYTICAL SERVICES, LLC SC DHEC No:32010001 NELAC No:E87653 NC DENR No:329 NC Field Parameters No:5639 Case Narrative Pace Analytical Services, Inc. Lot Number:WA23002 This Report of Analysis contains the analytical result(s)for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved The NELAC Institute (TNI) standards, the Pace Analytical Services, LLC ("Pace") Laboratory Quality Manual, standard operating procedures(SOPs), and Pace policies.Any exceptions to the TNI standards, the Laboratory Quality Manual, SOPs or policies are qualified on the results page or discussed below. If you have any questions regarding this report please contact the Pace Project Manager listed on the cover page. In the Matrix Spike and Matrix Spike Duplicate(MS/MSD) associated with sample-001, PFDOS recovered outside of the acceptance limits. The Laboratory Control Spike (LCS) recovered within the required acceptance limits; therefore, this demonstrates a matrix effect and data quality is not impacted. Pace Analytical Services,LLC(formerly Shealy Environmetal Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172(803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 12 of 30 Page 2 of 20 PACE ANALYTICAL SERVICES, LLC Sample Summary Pace Analytical Services, Inc. Lot Number: WA23002 Project Name: Savannah Wood Project Number: 92517799 Sample Number Sample ID Matrix Date Sampled Date Received 001 Effluent Aqueous 01/21/20211145 01/23/2021 002 Field Blank Aqueous 01/21/2021 1140 01/23/2021 (2 samples) Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 13 of 30 Page 3 of 20 PACE ANALYTICAL SERVICES, LLC Detection Summary Pace Analytical Services, Inc. Lot Number: WA23002 Project Name: Savannah Wood Project Number: 92517799 Sample Sample ID Matrix Parameter Method Result Q Units Page 001 Effluent Aqueous PFBS PFAS by ID 7.1 ng/L 5 001 Effluent Aqueous PFHxS PFAS by ID 5.9 ng/L 5 001 Effluent Aqueous PFBA PFAS by ID 9.6 ng/L 5 001 Effluent Aqueous PFHpA PFAS by ID 6.4 ng/L 5 001 Effluent Aqueous PFHxA PFAS by ID 12 ng/L 5 001 Effluent Aqueous PFOA PFAS by ID 15 ng/L 5 001 Effluent Aqueous PFPeA PFAS by ID 13 ng/L 5 001 Effluent Aqueous PFOS PFAS by ID 17 ng/L 5 (8 detections) Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 14 of 30 Page 4 of 20 PFAS by LC/MS/MS Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-001 Description:Effluent Matrix:Aqueous Date Sampled:01/21/2021 1145 Project Name:Savannah Wood Date Received:01/23/2021 Project Number:92517799 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SOP SPE PFAS by ID SOP 1 01/28/2021 1547 JJG 01/27/2021 1043 80843 CAS Analytical Parameter Number Method Result Q LOQ Units Run 9-chlorohexadecafluoro-3-oxanone-1-sulfonic acid(9CI-PF3ONS) 756426-58-1 PFAS by ID SOP ND 7.4 ng/L 1 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid(11CI-PF3...) 763051-92-9 PFAS by ID SOP ND 7.4 ng/L 1 1H,1H,2H,2H-perfluorodecane sulfonic acid(8:2 FTS) 39108-34-4 PFAS by ID SOP ND 7.4 ng/L 1 1H,1H,2H,2H-perfluorooctane sulfonic acid(6:2 FTS) 27619-97-2 PFAS by ID SOP ND 7.4 ng/L 1 1H,1H,2H,2H-perfluorododecane sulfonic acid(10:2 FTS) 120226-60-0 PFAS by ID SOP ND 7.4 ng/L 1 1H,1H,2H,2H-perfluorohexane sulfonic acid(4:2 FTS) 757124-72-4 PFAS by ID SOP ND 7.4 ng/L 1 Hexafluoropropylene oxide dimer acid(GenX) 13252-13-6 PFAS by ID SOP ND 7.4 ng/L 1 4,8-dioxa-3H-perfluorononanoic acid(ADONA) 919005-14-4 PFAS by ID SOP ND 7.4 ng/L 1 N-ethylperfluoro-1-octanesulfonamide(EtFOSA) 4151-50-2 PFAS by ID SOP ND 7.4 nglL 1 N-ethylperfluoro-l-octanesulfonamidoacetic acid(EtFOSAA) 2991-50-6 PFAS by ID SOP ND 7.4 ng/L 1 2-N-ethylperfluoro-1-octanesulfonamido-ethanol(EtFOSE) 1691-99-2 PFAS by ID SOP ND 7.4 ng/L 1 N-methylperfluoro-l-octanesulfonamide(MeFOSA) 31506-32-8 PFAS by ID SOP ND 15 ng/L 1 N-methylperfluoro-1-octanesulfonamidoacetic acid(MeFOSAA) 2355-31-9 PFAS by ID SOP ND 7.4 ng/L 1 2-N-methylperfluoro-1-octanesulfonamido-ethanol(MeFOSE) 24448-09-7 PFAS by ID SOP ND 7.4 ng/L 1 Perfluoro-1-butanesulfonic acid(PFBS) 375-73-5 PFAS by ID SOP 7.1 3.7 ng/L 1 Perfluoro-l-decanesulfonic acid(PFDS) 335-77-3 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-l-heptanesulfonic acid(PFHpS) 375-92-8 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-l-nonanesulfonic acid(PFNS) 68259-12-1 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-1-octanesulfonamide(PEOSA) 754-91-6 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-1-pentanesulfonic acid(PFPeS) 2706-91-4 PFAS by ID SOP ND 3.7 ng/L 1 Perfluorododecanesulfonic acid(PFDOS) 79780-39-5 PFAS by ID SOP ND 7.4 ng/L 1 Perfluorohexanesulfonic acid(PFHxS) 355-46-4 PFAS by ID SOP 5.9 3.7 ng/L 1 Perfiuoro-n-butanoic acid(PFBA) 375-22-4 PFAS by ID SOP 9.6 3.7 ng/L 1 Perfluoro-n-decanoic acid(PFDA) 335-76-2 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-n-dodecanoic acid(PFDoA) 307-55-1 PFAS by ID SOP ND 3.7 ng/L 1 Perfiuoro-n-heptanoic acid(PFHpA) 375-85-9 PFAS by ID SOP 6.4 3.7 ng/L 1 Perfluoro-n-hexadecanoic acid(PFHxDA) 67905-19-5 PFAS by ID SOP ND 7.4 ng/L 1 Perfluoro-n-hexanoic acid(PFHxA) 307-24-4 PFAS by ID SOP 12 3.7 nglL 1 Perfluoro-n-nonanoic acid(PFNA) 375-95-1 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-n-octadecanoic acid(PFODA) 16517-11-6 PFAS by ID SOP ND 7.4 ng/L 1 Perfluoro-n-octanoic acid(PFOA) 335-67-1 PFAS by ID SOP 15 3.7 ng/L 1 Perfiuoro-n-pentanolc acid(PFPeA) 2706-90-3 PFAS by ID SOP 13 3.7 ng/L 1 Perfluoro-n-tetradecanoic acid(PFTeDA) 376-06-7 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-n-tridecanoic acid(PFTrDA) 72629-94-8 PFAS by ID SOP ND 3.7 ng/L 1 Perfluoro-n-undecanoic acid(PFUdA) 2058-94-8 PFAS by ID SOP ND 3.7 ng/L 1 Perfluorooctanesulfonic acid(PFOS) 1763-23-1 PFAS by ID SOP 17 3.7 ng!L 1 Run 1 Acceptance Surrogate Q %Recovery Limits 13C2_4:2FTS 143 25-150 13C2 6:2FTS 121 25-150 13C2_8:2FTS 95 25-150 13C2 PFDoA 76 25-150 13C2 PFHxDA 37 25-150 13C2 PFTeDA 49 25-150 LOQ=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% H=Out of holding time W=Reported on wet weight basis Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 15 of 30 Page 5 of 20 PFAS by LC/MS/MS Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-001 Description:Effluent Matrix:Aqueous Date Sampled:01/21/2021 1145 Project Name:Savannah Wood Date Received:01/2312021 Project Number:92517799 Run 1 Acceptance Surrogate Q %Recovery Limits 13C3_PFBS 94 25-150 13C3_PFHxS 88 25-150 13C3-HFPO-DA 102 25-150 13C4_PFBA 58 25-150 13C4_PFHpA 111 25-150 13C5_PFHxA 106 25-150 13C5_PFPeA 99 25-150 13C6_PFDA 91 25-150 13C7_PFUdA 85 25-150 13C8_PFOA 95 25-150 13C8_PFOS 75 25-150 13C8_PFOSA 99 10-150 13C9_PFNA 95 25-150 d-EtFOSA 76 10-150 d5-EtFOSAA 85 25-150 d9-EtFOSE 78 10-150 d-MeFOSA 91 10-150 d3-MeFOSAA 99 25-150 d7-MeFOSE 87 10-150 LOQ=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% H=Out of holding time W=Reported on wet weight basis Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 16 of 30 Page 6 of 20 PFAS by LC/MS/MS Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-002 Description:Field Blank Matrix:Aqueous Date Sampled:01/21/2021 1140 Project Name:Savannah Wood Date Received:01/23/2021 Project Number:92517799 Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 SOP SPE PFAS by ID SOP 1 01/28/2021 1536 JJG 01/27/2021 1043 80843 CAS Analytical Parameter Number Method Result Q LOQ Units Run 9-chlorohexadecafluoro-3-oxanone-1-sulfonic acid(9CI-PF3ONS) 756426-58-1 PFAS by ID SOP ND 7.9 ng/L 1 11-chloroeicosafluoro-3-oxaundecane-1-sulfonic acid(11CI-PF3...) 763051-92-9 PFAS by ID SOP ND 7.9 ng/L 1 1H,1H,2H,2H-perfluorodecane sulfonic acid(8:2 FTS) 39108-34-4 PFAS by ID SOP ND 7.9 ng/L 1 1H,1H,2H,2H-perfluorooctane sulfonic acid(6:2 FTS) 27619-97-2 PFAS by ID SOP ND 7.9 ng/L 1 1 H,1 H,2H,2H-perfluorododecane sulfonic acid(10:2 FTS) 120226-60-0 PFAS by ID SOP ND 7.9 ng/L 1 1H,1H,2H,2H-perfluorohexane sulfonic acid(4:2 FTS) 757124-72-4 PFAS by ID SOP ND 7.9 ng/L 1 Hexafluoropropylene oxide dimer acid(GenX) 13252-13-6 PFAS by ID SOP ND 7.9 ng/L 1 4,8-dioxa-3H-perfluorononanoic acid(ADONA) 919005-14-4 PFAS by ID SOP ND 7.9 ng/L 1 N-ethylperfluoro-1-octanesulfonamide(EtFOSA) 4151-50-2 PFAS by ID SOP ND 7.9 ng/L 1 N-ethylperfluoro-1-octanesulfonamidoacetic acid(EtFOSAA) 2991-50-6 PFAS by ID SOP ND 7.9 ng/L 1 2-N-ethylperfluoro-1-octanesulfonamido-ethanol(EtFOSE) 1691-99-2 PFAS by ID SOP ND 7.9 ng/L 1 N-methylperfluoro-1-octanesulfonamide(MeFOSA) 31506-32-8 PFAS by ID SOP ND 16 ng/L 1 N-methylperfluoro-1-octanesulfonamidoacetic acid(MeFOSAA) 2355-31-9 PFAS by ID SOP ND 7.9 ng/L 1 2-N-methylperfluoro-1-octanesulfonamido-ethanol(MeFOSE) 24448-09-7 PFAS by ID SOP ND 7.9 ng/L 1 Perfluoro-1-butanesulfonic acid(PFBS) 375-73-5 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-1-decanesulfonic acid(PFDS) 335-77-3 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-1-heptanesulfonic acid(PFHpS) 375-92-8 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro=l-nonanesulfonic acid(PFNS) 68259-12-1 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-1-octanesulfonamide(PFOSA) 754-91-6 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-1-pentanesulfonic acid(PFPeS) 2706-91-4 PFAS by ID SOP ND 4.0 ng/L 1 Perfluorododecanesulfonic acid(PFDOS) 79780-39-5 PFAS by ID SOP ND 7.9 ng/L 1 Perfluorohexanesulfonic acid(PFHxS) 355-46-4 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-n-butanoic acid(PFBA) 375-22-4 PFAS by ID SOP ND 4.0 ng/L 1 1 Perfluoro-n-decanoic acid(PFDA) 335-76-2 PFAS byID SOP ND 4.0 ng/L 1 9 Perfluoro-n-dodecanoic acid(PFDoA) 307-55-1 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-n-heptanoic acid(PFHpA) 375-85-9 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-n-hexadecanoic acid(PFHxDA) 67905-19-5 PFAS by ID SOP ND 7.9 ng/L 1 Perfluoro-n-hexanoic acid(PFHxA) 307-24-4 PFAS byID SOP ND 4.0 ng/L 1 9 Perfluoro-n-nonanoic acid(PFNA) 375-95-1 PFAS by ID SOP ND 4.0 ng/L 1 Perfiuoro-n-octadecanoic acid(PFODA) 16517-11-6 PFAS by ID SOP ND 7.9 ng/L 1 Perfluoro-n-octanoic acid(PFOA) 335-67-1 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-n-pentanoic acid(PFPeA) 2706-90-3 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-n-tetradecanoic acid(PFTeDA) 376-06-7 PFAS by ID SOP ND 4.0 ng/L 1 -Perfluoro-n-tridecanoic acid(PFTrDA) 72629-94-8 PFAS by ID SOP ND 4.0 ng/L 1 Perfluoro-n-undecanoic acid(PFUdA) 2058-94-8 PFAS by ID SOP ND 4.0 ng/L 1 Perfluorooctanesulfonic acid(PFOS) 1763-23-1 PFAS by ID SOP ND 4.0 ng/L 1 Run 1 Acceptance Surrogate Q %Recovery Limits 13C2_4:2FTS 115 25-150 13C2 6:2FTS 109 25-150 13C2 8:2FTS 111 25-150 13C2 PFDoA 103 25-150 13C2 PFHxDA 35 25-150 13C2 PFTeDA 52 25-150 LOQ=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% H=Out of holding time W=Reported on wet weight basis Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 17 of 30 Page 7 of 20 PFAS by LC/MS/MS Client:Pace Analytical Services,Inc. Laboratory ID:WA23002-002 Description:Field Blank Matrix:Aqueous Date Sampled:01/21/2021 1140 Project Name:Savannah Wood Date Received:01/23/2021 Project Number:92517799 Run 1 Acceptance Surrogate Q %Recovery Limits 13C3 PFBS 101 25-150 13C3_PFHxS 103 25-150 13C3-HFPO-DA 107 25-150 13C4 PFBA 106 25-150 13C4_PFHpA 119 25-150 13C5_PFHxA 109 25-150 13C5_PFPeA 107 25-150 13C6 PFDA 101 25-150 13C7_PFUdA 104 25-150 13C8_PFOA 108 25-150 13C8_PFOS 102 25-150 13C8_P FOSA 107 10-150 13C9_PFNA 103 25-150 d-EtFOSA 89 10-150 d5-EtFOSAA 104 25-150 d9-EtFOSE 122 10-150 d-MeFOSA 94 10-150 d3-MeFOSAA 108 25-150 d7-MeFOSE 109 10-150 LOG=Limit of Quantitation B=Detected in the method blank E=Quantitation of compound exceeded the calibration range ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% H=Out of holding time W=Reported on wet weight basis Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 18 of 30 Page 8 of 20 QC Summary Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 19 of 30 Page 9 of 20 PFAS by LC/MS/MS - MB Sample ID:W080843-001 Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Parameter Result Q Dil LOQ Units Analysis Date 9CI-PF3ONS ND 1 8.0 ng/L 01/28/2021 1400 11CI-PF3OUdS ND 1 8.0 ng/L 01/28/2021 1400 8:2 FTS ND 1 8.0 ng/L 01/28/2021 1400 6:2 FTS ND 1 8.0 ng/L 01/28/2021 1400 10:2 FTS ND 1 8.0 ng/L 01/28/2021 1400 4:2 FTS ND 1 8.0 ng/L 01/28/2021 1400 GenX ND 1 8.0 ng/L 01/28/2021 1400 ADONA ND 1 8.0 ng/L 01/28/2021 1400 EtFOSA ND 1 8.0 ng/L 01/28/2021 1400 I EtFOSAA ND 1 8.0 ng/L 01/28/2021 1400 EtFOSE ND 1 8.0 ng/L 01/28/2021 1400 MeFOSA ND 1 16 ng/L 01/28/2021 1400 MeFOSAA ND 1 8.0 ng/L 01/28/2021 1400 MeFOSE ND 1 8.0 ng/L 01/28/2021 1400 PFBS ND 1 4.0 ng/L 01/28/2021 1400 PFDS ND 1 4.0 ng/L 01/28/2021 1400 PFHpS ND 1 4.0 ng/L 01/28/2021 1400 PFNS ND 1 4.0 ng/L 01/28/2021 1400 PFOSA ND 1 4.0 ng/L 01/28/2021 1400 PFPeS ND 1 4.0 ng/L 01/28/2021 1400 PFDOS ND 1 8.0 ng/L 01/28/2021 1400 PFHxS ND 1 4.0 ng/L 01/28/2021 1400 PFBA ND 1 4.0 ng/L 01/28/2021 1400 PFDA ND 1 4.0 ng/L 01/28/2021 1400 PFDoA ND 1 4.0 ng/L 01/28/2021 1400 PFHpA ND 1 4.0 ng/L 01/28/2021 1400 PFHxDA ND 1 8.0 ng/L 01/28/2021 1400 PFHxA ND 1 4.0 ng/L 01/28/2021 1400 PFNA ND 1 4.0 ng/L 01/28/2021 1400 PFODA ND 1 8.0 ng/L 01/28/2021 1400 PFOA ND 1 4.0 ng/L 01/28/2021 1400 PFPeA ND 1 4.0 ng/L 01/28/2021 1400 PFTeDA ND 1 4.0 ng/L 01/28/2021 1400 PFTrDA ND 1 4.0 ng/L 01/28/2021 1400 PFUdA ND 1 4.0 ng/L 01/28/2021 1400 PFOS ND 1 4.0 ng/L 01/28/2021 1400 Acceptance Surrogate Q %Rec Limit - 13C2_4:2FTS 110 25-150 13C2 6:2FTS 108 25-150 13C2_8:2FTS 108 25-150 13C2 PFDoA 100 25-150 13C2_PFHxDA 106 25-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% '=RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 20 of 30 Page 10 of 20 PFAS by LC/MS/MS - MB Sample ID:WQ80843-001 Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Acceptance Surrogate Q %Rec Limit 13C2_PFTeDA 102 25-150 13C3_PFBS 97 25-150 13C3_PFHxS 95 25-150 13C3-HFPO-DA 104 25-150 13C4_PFBA 103 25-150 13C4_PFHpA 119 25-150 13C5 PFHxA 103 25-150 13C5_PFPeA 103 25-150 13C6_PFDA 99 25-150 13C7_PFUdA 99 25-150 13C8_PFOA 106 25-150 13C8 PFOS 92 25-150 13C8_PFOSA 102 10-150 13C9_PFNA 101 25-150 d-EtFOSA 98 10-150 d5-EtFOSAA 100 25-150 d9-EtFOSE 123 10-150 d-MeFOSA 106 10-150 d3-MeFOSAA 103 25-150 d7-MeFOSE 116 10-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% =RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 21 of 30 Page 11 of 20 PFAS by LC/MS/MS - LCS Sample ID:WQ80843-002 Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Spike Amount Result %Rec Parameter (nglL) (ng/L) Q Dil %Rec Limit Analysis Date 9C1-PF3ONS 15 15 1 99 50-150 01/29/2021 1506 11CI-PF3OUdS 15 15 1 97 50-150 01/29/2021 1506 8:2 FTS 15 15 1 97 50-150 01/29/2021 1506 6:2 FTS 15 21 1 138 50-150 01/29/2021 1506 10:2 FTS 15 15 1 96 50-150 01/29/2021 1506 4:2 FTS 15 14 1 97 50-150 01/29/2021 1506 GenX 32 34 1 106 50-150 01/29/2021 1506 ADONA 15 16 1 104 50-150 01/29/2021 1506 EtFOSA 16 17 1 107 50-150 01/29/2021 1506 EtFOSAA 16 16 1 99 50-150 01/29/2021 1506 EtFOSE 16 16 1 99 50-150 01/29/2021 1506 MeFOSA 16 16 1 98 50-150 01/29/2021 1506 MeFOSAA 16 15 1 95 50-150 01/29/2021 1506 MeFOSE 16 17 1 104 50-150 01/29/2021 1506 PFBS 14 13 1 95 50-150 01/29/2021 1506 PFDS 15 15 1 97 50-150 01/29/2021 1506 PFHpS 15 16 1 107 50-150 01/29/2021 1506 PFNS 15 15 1 94 50-150 01/29/2021 1506 PFOSA 16 16 1 100 50-150 01/29/2021 1506 PFPeS 15 16 1 109 50-150 01/29/2021 1506 PFDOS 15 15 1 96 50-150 01/29/2021 1506 PFHxS 15 14 1 96 50-150 01/29/2021 1506 PFBA 16 17 1 103 50-150 01/29/2021 1506 PFDA 16 16 1 98 50-150 01/29/2021 1506 PFDoA 16 16 1 101 50-150 01/29/2021 1506 PFHpA 16 17 1 104 50-150 01/29/2021 1506 PFHxDA 16 16 1 102 50-150 01/29/2021 1506 PFHxA 16 16 1 102 50-150 01/29/2021 1506 PFNA 16 16 1 99 50-150 01/29/2021 1506 PFODA 16 15 1 97 50-150 01/29/2021 1506 PFOA 16 16 1 99 50-150 01/29/2021 1506 PFPeA 16 16 1 102 50-150 01/29/2021 1506 PFTeDA 16 16 1 100 50-150 01/29/2021 1506 PFTrDA 16 17 1 108 50-150 01/29/2021 1506 PFUdA 16 17 1 104 50-150 01/29/2021 1506 PFOS 15 14 1 92 50-150 01/29/2021 1506 Acceptance Surrogate Q %Rec Limit 13C2_4:2FTS 98 25-150 -I" 13C2_6:2FTS 102 25-150 13C2_8:2FTS 88 25-150 13C2_PFDoA 95 25-150 13C2_PFHxDA 97 25-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% •=RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 22 of 30 Page 12 of 20 PFAS by LC/MS/MS - LCS Sample ID:WQ80843-002 Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Acceptance Surrogate Q %Rec Limit 13C2_PFTeDA 93 25-150 13C3_PFBS 89 25-150 13C3_PFHxS 92 25-150 13C3-HFPO-DA 98 25-150 13C4_PFBA 98 25-150 13C4_PFHpA 100 25-150 13C5_PFHxA 99 25-150 13C5_PFPeA 99 25-150 13C6_PFDA 100 25-150 13C7_PFUdA 90 25-150 13C8_PFOA 95 25-150 13C8_PFOS 90 25-150 13C8_PFOSA 97 10-150 13C9_PFNA 99 25-150 d-EtFOSA 88 10-150 d5-EtFOSAA 93 25-150 d9-EtFOSE 94 10-150 d-MeFOSA 80 10-150 d3-MeFOSAA 94 25-150 d7-MeFOSE 97 10-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% •=RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 23 of 30 Page 13 of 20 11 PFAS by LC/MS/MS - MS Sample ID:WA23002-001MS Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Sample Spike Amount Amount Result %Rec Parameter (ng/L) (ng/L) (ng/L) Q Dil %Rec Limit Analysis Date 9C1-PF3ONS ND 14 11 1 79 50-150 01/28/2021 1558 11CI-PF3OUdS ND 14 8.4 1 61 50-150 01/28/2021 1558 8:2 FTS ND 14 15 1 109 50-150 01/28/2021 1558 6:2 FTS ND 14 13 1 93 50-150 01/28/2021 1558 10:2 FTS ND 14 12 1 83 50-150 01/28/2021 1558 4:2 FTS ND 14 12 1 88 50-150 01/28/2021 1558 GenX ND 29 28 1 96 50-150 01/28/2021 1558 ADONA ND 14 14 1 101 50-150 01/28/2021 1558 EtFOSA ND 15 12 1 85 50-150 01/28/2021 1558 EtFOSAA ND 15 13 1 86 50-150 01/28/2021 1558 EtFOSE ND 15 12 1 79 50-150 01/28/2021 1558 MeFOSA ND 15 14 1 94 50-150 01/28/2021 1558 MeFOSAA ND 15 12 1 82 50-150 01/28/2021 1558 MeFOSE ND 15 12 1 83 50-150 01/28/2021 1558 PFBS 7.1 13 18 1 82 50-150 01/28/2021 1558 PFDS ND 14 10 1 72 50-150 01/28/2021 1558 PFHpS ND 14 13 1 93 50-150 01/28/2021 1558 PFNS ND 14 12 1 85 50-150 01/28/2021 1558 PFOSA ND 15 14 1 93 50-150 01/28/2021 1558 PFPeS ND 14 15 1 110 50-150 01/28/2021 1558 PFDOS ND 14 6.5 N 1 46 50-150 01/28/2021 1558 PFHxS 5.9 13 17 1 85 50-150 01/28/2021 1558 PFBA 9.6 15 22 1 86 50-150 01/28/2021 1558 PFDA ND 15 14 1 98 50-150 01/28/2021 1558 PFDoA ND 15 13 1 88 50-150 01/28/2021 1558 PFHpA 6.4 15 19 1 89 50-150 01/28/2021 1558 PFHxDA ND 15 14 1 96 50-150 01/28/2021 1558 PFHxA 12 15 25 1 91 50-150 01/28/2021 1558 PFNA ND 15 15 1 100 50-150 01/28/2021 1558 PFODA ND 15 11 1 76 50-150 01/28/2021 1558 PFOA 15 15 27 1 82 50-150 01/28/2021 1558 PFPeA 13 15 25 1 83 50-150 01/28/2021 1558 PFTeDA ND 15 14 1 92 50-150 01/28/2021 1558 PFTrDA ND 15 12 1 81 50-150 01/28/2021 1558 PFUdA ND 15 13 1 92 50-150 01/28/2021 1558 PFOS 17 14 29 1 90 50-150 01/28/2021 1558 Acceptance Surrogate Q %Rec Limit 13C2_4:2FTS 138 25-150 _ 13C2_6:2FTS 113 25-150 13C2_8:2FTS 95 25-150 13C2 PFDoA 83 25-150 13C2_PFHxDA 44 25-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% •=RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 24 of 30 Page 14 of 20 PFAS by LC/MS/MS - MS Sample ID:WA23002-001MS Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Acceptance Surrogate Q %Rec Limit 13C2_PFTeDA 55 25-150 13C3_PFBS 91 25-150 13C3_PFHxS 85 25-150 13C3-HFPO-DA 97 25-150 13C4_PFBA 58 25-150 13C4_PFHpA 101 25-150 13C5_PFHxA 100 25-150 13C5_PFPeA 93 25-150 13C6 PFDA 88 25-150 13C7_PFUdA 87 25-150 13C8_PFOA 92 25-150 13C8_PFOS 84 25-150 13C8_PFOSA 99 10-150 13C9_PFNA 92 25-150 d-EtFOSA 82 10-150 d5-EtFOSAA 92 25-150 d9-EtFOSE 83 10-150 d-MeFOSA 87 10-150 d3-MeFOSAA 96 25-150 d7-MeFOSE 87 10-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOG N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% =RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 25 of 30 Page 15 of 20 PFAS by LC/MS/MS - MSD Sample ID:WA23002-001 MD Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Sample Spike Amount Amount Result %Rec %RPD Parameter (ng/L) (ng/L) (ng/L) Q Dil %Rec %RPD Limit Limit Analysis Date 9C1-PF3ONS ND 14 10 1 76 3.1 50-150 30 01/28/2021 1608 11CI-PF3OUdS ND 14 8.0 1 57 4.9 50-150 30 01/28/2021 1608 8:2 FTS ND 14 16 1 111 2.9 50-150 30 01/28/2021 1608 6:2 FTS ND 14 17 1 118 25 50-150 30 01/28/2021 1608 10:2 FTS ND 14 11 1 77 6.2 50-150 30 01/28/2021 1608 4:2 FTS ND 14 12 1 89 2.5 50-150 30 01/28/2021 1608 GenX ND 30 28 1 94 0.59 50-150 30 01/28/2021 1608 ADONA ND 14 14 1 99 1.4 50-150 30 01/28/2021 1608 EtFOSA ND 15 15 1 99 18 50-150 30 01/28/2021 1608 EtFOSAA ND 15 14 1 94 9.9 50-150 30 01/28/2021 1608 EtFOSE ND 15 14 1 94 19 50-150 30 01/28/2021 1608 MeFOSA ND 15 14 1 96 4.0 50-150 30 01/28/2021 1608 MeFOSAA ND 15 13 1 90 10 50-150 30 01/28/2021 1608 MeFOSE ND 15 14 1 91 11 50-150 30 01/28/2021 1608 PFBS 7.1 13 20 1 97 11 50-150 30 01/28/2021 1608 PFDS ND 14 11 1 74 4.7 50-150 30 01/28/2021 1608 PFHpS ND 14 12 1 86 6.6 50-150 30 01/28/2021 1608 PFNS ND 14 12 1 83 1.1 50-150 30 01/28/2021 1608 PFOSA ND 15 13 1 89 3.1 50-150 30 01/28/2021 1608 PFPeS ND 14 16 1 113 4.3 50-150 30 01/28/2021 1608 PFDOS ND 14 5.8 N 1 40 11 50-150 30 01/28/2021 1608 PFHxS 5.9 14 18 1 88 3.9 50-150 30 01/28/2021 1608 PFBA 9.6 15 23 1 92 4.4 50-150 30 01/28/2021 1608 PFDA ND 15 15 1 101 4.0 50-150 30 01/28/2021 1608 PFDoA ND 15 14 1 94 7.5 50-150 30 01/28/2021 1608 PFHpA 6.4 15 19 1 84 2.7 50-150 30 01/28/2021 1608 PFHxDA ND 15 14 1 95 1.1 50-150 30 01/28/2021 1608 PFHxA 12 15 29 1 112 12 50-150 30 01/28/2021 1608 PFNA ND 15 16 1 110 11 50-150 30 01/28/2021 1608 PFODA ND 15 10 1 69 9.1 50-150 30 01/28/2021 1608 PFOA 15 15 27 1 85 2.2 50-150 30 01/28/2021 1608 PFPeA 13 15 27 1 92 6.0 50-150 30 01/28/2021 1608 PFTeDA ND 15 14 1 93 2.0 50-150 30 01/28/2021 1608 PFTrDA ND 15 12 1 82 3.1 50-150 30 01/28/2021 1608 PFUdA ND 15 14 1 94 3.8 50-150 30 01/28/2021 1608 PFOS 17 14 28 1 82 3.4 50-150 30 01/28/2021 1608 Acceptance Surrogate Q %Rec Limit 13C2_4:2FTS 145 25-150 13C2_6:2FTS 109 25-150 13C2_8:2FTS 99 25-150 13C2_PFDoA 74 25-150 13C2_PFHxDA 35 25-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% •=RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 26 of 30 Page 16 of 20 PFAS by LC/MS/MS - MSD Sample ID:WA23002-001MD Matrix: Aqueous Batch:80843 Prep Method: SOP SPE Analytical Method:PFAS by ID SOP Prep Date: 01/27/2021 1043 Acceptance Surrogate Q %Rec Limit 13C2_PFTeDA 47 25-150 13C3_PFBS 88 25-150 13C3_PFHxS 88 25-150 13C3-HFPO-DA 97 25-150 13C4_PFBA 56 25-150 13C4_PFHpA 114 25-150 13C5_PFHxA 95 25-150 13C5_PFPeA 93 25-150 13C6_PFDA 89 25-150 13C7_PFUdA 86 25-150 13C8_PFOA 94 25-150 13C8_PFOS 71 25-150 13C8_PFOSA 99 10-150 13C9 PFNA 90 25-150 d-EtFOSA 83 10-150 d5-EtFOSAA 86 25-150 d9-EtFOSE 77 10-150 d-MeFOSA 88 10-150 d3-MeFOSAA 90 25-150 d7-MeFOSE 88 10-150 LOQ=Limit of Quantitation ND=Not detected at or above the LOQ N=Recovery is out of criteria P=The RPD between two GC columns exceeds 40% •=RSD is out of criteria +=RPD is out of criteria Note: Calculations are performed before rounding to avoid round-off errors in calculated results Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) QC Data for Lot Number:WA23002 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 27 of 30 Page 17 of 20 Chain of Custody and Miscellaneous Documents Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 28 of 30 Page 18 of 20 7 O co 0 N 0 m Li . L Jo 1..IV d 890Z43ieNSZ OO'tii'Luu-J-TIV-.Li S';;'$L=So-JL LLOZ'ZZrJ5tw1;^':;�_n,1 U _J I . CO I - t 70:.kraiuqui/AUNO all(ul nirmJtnn:?sr co-yxwiotr,7 soca apart or 5•..7;JoiL1wou pe.vr.NSUC2 S l,POJSan:O'ir ,7'd..u. E W -iti top;JU:�-S?U/uo QapinoJd aq Jou XSa ' irl0ii.fa r:p:i,'r araou s,..,9jJt,L/_, 'arts Su,•�dua3s ar,110 u--)u/u�ri ooJ )ig.nu,p;J,ra iu l j,-r Lu 3:0-y.,U. ,-apjv ui,,.,, 8 U1 7_ IUL S31tltu'er� ,-.. ..M a"3j "Ji:nia�e /'� 1... JD -._. • .T�....._...-..._, ,-L.__---... '- __ i1 1, lea hpa33ii3 I 3, Y` iJi yea un airlis aclula/Ial64j1 Ce • .,w4li•1 .cc,panic ti r - as - ae5-.., .w,J,alepi� AA Pas*+ »i� :.Lalsucll, [ I I] ,-,-,-. 0, I t on - I : I �E X 17 i 4_,j L r mR/�h; 6OCEZ.U.lSZ6I 6k•lt LT.oZILieL- Sd�_ _»•- yorca0m,i ri� _ 1 ° J 1 �,�,�,I i 1 I ?�I }( � I i I 1 L ' -AImiJ.I LOCO[i!/L,iSj 5v:lt LEUZ/Lf1L ^i.-Li I I'W2•1 2 O Q .1hNO E3ri v iI r i € -- "--b i --. .•.�: 4'. :•: �r j ,•. �— ° or Z 1 ! Hi-:.:-.4'".2.":4 1 '4FWil'1. - .,y -Crt,;1-I• .aii(ilaLF:SI ;:A.I, .y:._. •- �:il4uia L:A_i1• Q 1i s 1 i }11 e1 '.� {a: th lti- rlc asj•13 ti -- ; Y,�• W i zc.a i 1 . 1 i l�•:�lr`ltdr.O-S.?^'7'�g.:; _A E w U yI 4 r 1 ZiooCCiVM t • , f 1 ii ! s i E aseE �� .�L}5L 7lJ�l t:� J 1 O:L6-I.6L:c_'4B7 3CL71ar af.i19Z :IN'alllrsialunl I t6Z :.,S'aWu illo 3 i M COL a1r�3 •ItAV Aaaui>l��OSG a, E 4 g anud 11-4,1 O 1;t:/h 3'JL •9UarI U 1�=iL��trl�aa3� E o : i i 3g Y ZL 1 r.muLrq,i:.Ls2.M i•einAl2u v aa^.j srlool- ,,.;iiA I • o U r..,: ,:-i4_ ':,, ..-.$I: Guy p::::3.tUeZ;.. `-s.-. 1, .. M1waw.wgsyn�.�g .- '?l E.telfi�i. I LZOZ1bie :F-2 .' a i�r.bey$linsau 1.,3ZILZit :tYra Fe%s-•s:i-�. ?or,,, Jou/A° •,gauuen :g; aiLls•.' -)!oy{raivi f6v.,,i;76 'JaP- i-Sam - i I zie pi SSA : ,:e�sa �a� 8 ; ;jrJ•..;Li L L peelx-- Jd se,du:eS 0 ! .._..M�._. .. ... .4,0°,1';sno to 7.Tego. .162_suf a. :i;3Ei.iew ° LL sm . Q � U .p O ! tit' PACE ANALYTICAL SERVICES, LLC � Samples Receipt Checklist(SRC}{M60018C-15} i+Y JI;j /29/202D 911 /' .Pacerraly'tiaai :suingAuthority:PaceENV-WOOL \A23002 4ge1of1 Sample Receipt Checklist cklist SR ) � �f KLe'e Clierd:` Cooler Inspected by elate: �-' /j c' r-1 r.nl A Means of rceeipC-,El Pace ❑Client ❑UPS E-edt:x (_(Other: Yes aNc F,I.Were custody seals present on the cooler" Yes iNo Ell A.. If cus.tndy seals were present,were they'ileac:and unbroken? pH Strip ID: pal - Clllotine Strip ID:..._.__' G_. Tested by: t' -C._, 1 Original temperature upon leceilri l Derived(Corrected)temperature upon receipt %Solid Snap-Cup IC): _f 1 1-1, Svc-3''-.1 C'.._- v{. }flC,'•-•-Vic' YLt ` ,� I Method:❑femperatl:re Black❑Against Bottles 1K(inn ID: �� Ik(ion Correction factor °C Method of coolant: ❑Wct ice ❑ ice Packs ❑ Dry Ice ❑ None i II-temperature of any cooler exceeded 5.0°C,was Project Manager Notified? El Yes ❑No LJ NA PM was Notified by:phone i email/ fce.o-face(circle one). EYE (i No 'NA 4. Is the commercial courier's packing slip attached to this fo-n? —_ U Nu 5. Were proffer custody n:rieesLrres(reliny:ri.;hedireceivett)followed? Du'rs f No 5. Wore sairple lLs lisxd on the COC? ❑Nn 7. Were sample Ins listed on all sample Containers? ❑No W � 8. Was collection date&time 1is rl on the COO? II ❑No 9. Was collection date&time lined on all sample containers? j. }Ycs ❑NU 110.Did all container lobe:information(ID,date,time)agree with the COC? fl Yts ❑No 1:I. Were tests to be performed listed on the COC? '2. Did all samples anive in the proper containers for each test andior:n good condition ErYes ❑No, (unbroken,.ids on,etc_)? 4YC . L..JNoli 13.Was adequate sample volume ava=labte? es UNo: 14.Were all samples receivec within'A tlyi.....11kidst-M4 time or 48 hours,whichever comes first? 21es IJ Nal 15,Were any samples containers missidgxcess(elretc one)samp:es Not listed on COC? l 1' 16,far VOA an:l RSK-175 samples,wer TTthles present>' ea-:iv,e"(/h"tr Cinlin in diameter) ❑A Yec ❑Nn ?in any of the VOA vial:;? Yes LIND 17.Were all DROh sam ples mples received at a pH of<2:' Yes LI No W.T. I S.We:e ill cy-Lnido samples received at a i1-i>t2 in id S;11:I1.IC SUE:lnles received a:n pH>9? ❑Ycs ❑No " 19. Were all applicable NIG/TKNicyailde:pheyoI/623.1/i08.3 (<0.5mg,'L)samples tree a}' A residual chlorine? , ID yes ,/ 20.Were client remarks/requests(i.e.requested dilutions,MS NISI)designations,etc...) ❑No � -NA correctly transcribed from the COD into.he comment section in LAMS? RYca No 21. Was the quote r_urnbe.r listed on the container label?If yes,Quote _ _ Sample Preservation (Ivlust he completed for any sarnplc(s)incorrectly presetti:12d or with headspace — Samplc(s) _W-:' _______ were received incorrectty preserved and were adiusted accordingly in sample rcccivtng with mL of circle one:H2SO4,HNO3,HCI,NaOH using SR t` }' , Time of pres.sel-vt L]on , If more then one prescvvulive is needed,please note in the comments below. Sample(s) 'C!, were received with bdaules>6 mm in diameter, Samples(s) 1'1 - were received wits'1 1W>0.5 mg/L(if#l9 'is no)end were adjusted accordingly in sample receiving with sodium thiosulfate(N1•20;)with,Shealy ID: ,_(\ _ , SR barcode labels applied by; s Date: .�j� _t-'S'1- „), .---- ?Comments: -ei,,-,'\v?.c\ .1 %') r ,;..,..4.?(\.:..;‘, .,.r\o,--Ve_e_ . „(._\ t'‘N Pace Analytical Services,LLC (formerly Shealy Environmental Services,Inc.) 106 Vantage Point Drive West Columbia,SC 29172 (803)791-9700 Fax(803)791-9111 www.pacelabs.com Page 30 of 30 Page 20 of 20 A * Perfluoro-l-pentanesulfonic acid PFPeS 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluorododecanesulfonic acid PFDOS 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluorohexanesulfonic acid PFHxS 1/21/2021 5.9 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-butanoic acid PFBA 1/21/2021 9.6 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-decanoic acid PFDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-dodecanoic acid PFDoA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-heptanoic acid PFHpA 1/21/2021 6.4 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-hexadecanoic acid PFHxDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-hexanoic acid PFHxA 1/21/2021 12 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-nonanoic acid PFNA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluroro-n-octadecanoic acid PFODA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-octanoic acid PFOA 1/21/2021 15 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-pentanoic acid PFPeA 1/21/2021 13 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-tetradecanoic acid PFTeDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-tridecanoic acid PFTrDA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluoro-n-undecanoic acid PFUdA 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear Perfluorooctanesulfonic acid PFOS 1/21/2021 17 Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear 1,4 Dioxane p-Dioxane 1/21/2021 ND Influent Grab Permitee Raleigh Industrial NC0000892 Arclin USA Cape Fear