Loading...
HomeMy WebLinkAboutSW8950202_Current Permit_200801250 WATF9 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen H. SulIins Director Division of Water Quality Mr. R. Allen Rippy R & R Company of Wilmington 4951 New Center Drive Wilmington, NC 28403 January 25, 2008 Subject: Stormwater Permit No. SW8 950202 Renewal Rippy Cadillac Olds High Density Project New Hanover County Dear Mr. Rippy: The Wilmington Regional. Office received a complete Stormwater Management Permit Application for Rippy Cadillac Olds on September 6, 2007. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 950202 dated January 25, 2008, for the construction and operation of the subject project. This permit shall be effective from the date of issuance until January 25, 2018, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. The reissuance of this -stormwater permit does not imply that the site is currently in compliance with the terms and conditions of this state stormwater permit. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within sixty (60) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact David Cox, or me at (910) 796-7215. Since y, E ward eck Regional Supervisor Surface Water Protection Section ENB/dwc: S:IWQSISTORMWATERIPERMIT1970828Ren.nov07 cc: New Hanover County Building Inspections City of Wilmington Development Services Beth E. Wetherill, New Hanover County Engineering Wilmington Regional Office No"AhC-arol' a Central Files natural North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: www.ncwaterguality.org Fax (910) 350-2004 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer - 50% Recycledl10% Post Consumer Paper . State Stormwater Management Systems Permit No. SW8 950202 Renewal STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Mr. R. Allen Rippy & R & R Company of Wilmington Rippy Cadillac Olds New Hanover County FOR THE construction, operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until January 25, 2008, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.6 on page 3 of this permit. The stormwater control has been designed to handle the runoff from 58,049 square feet of impervious area. 3. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. 6. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: Page 2 of 7 State Stormwater Management Systems Permit No. SW8 950202 Renewal a. Drainage Area, 9cres: Onsite, ft : Offsite, ft2: b. Total Impervious Surfaces, ft2: C. Design Storm, inches: d. Pond Depth, feet: e. TSS removal efficiency: f. Permanent Pool Elevation, FMSL: g. Permanent Pool Surface Area, ft2: h. Permitted Storage Volume, ft3: Temporary Storage Elevation, FMSL: j. Controlling Orifice: k. Receiving Stream/River Basin I. Stream Index Number: M. Classification of Water Body: II. SCHEDULE OF COMPLIANCE 10.01 436,036 0 353,425 4 90 38 31,119 32,477 39 3" O pipe Burnt Mill / Cape Fear 19-74-63-2 "C Sw" 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all time provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and re -vegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. Page 3 of 7 State Stormwater Management Systems Permit No. SW8 950202 Renewal 5. The facilities shall be constructed as shown on the approved plans. This permit shall become void unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 6. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 7. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 8. Access to the stormwater facilities shall be maintained via appropriate easements at all times. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, lease or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the -site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. Page 4of7 State Stormwater Management Systems Permit No. SW8 950202 Renewal r III. GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director. In the event of a change of ownership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and re -issuance or termination does not stay any permit condition. 7. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 25th day of January, 2008. NORT AROLINA ENVIRONMENTAL MANAGEMENT COMMISSION for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Page 5 of 7 State Stormwater Management Systems Permit No. SW8 950202 Renewal Furr Retail Stormwater Permit No. SW8 950202 Renewal New Hanover County Designer's Certification 1, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL Page 6 of 7 State Stormwater Management Systems Permit No. SW8 950202 Renewal Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the. system. 4. All roof drains are located such that the runoff is directed into the system. 5. The outlet/bypass structure elevations are per the approved plan. 6. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet/bypass structure. 8. All slopes are grassed with permanent vegetation. 9. Vegetated slopes are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. 12. Required drawdown devices are correctly sized per the approved plans. 13. All required design depths are provided. 14. All required parts of the system are provided, such as a vegetated shelf, and a forebay. .15. The required system dimensions are provided per the approved plans. cc: NCDENR-DWQ Regional Office New Hanover County Building Inspections Page 7 of 7 f cC� % 1— ro /1A �F W A FFA r 0 7/6 f Michael F. Easley, Governor y William G. Ross Jr., Secretary r North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director �Division of Water Quality SURFACE WATER PROTECTION SECTION COASTAL STORMWATER PERMIT RENEWAL APPLICATION FORM L CURRENT PERMIT INFORMATION: 1. Stormwater Management Permit Number: SW8 950202 + " ; W og 2. Permit Holder's name: R & R Company of Wilmington (company, partnership, corporation, LLC, or individual) 3. Signing official's name: R. Allen Rippv Title: Partner (person legally responsible for permit) 4. Mailing address: 4951 New Centre Drive City: Wilmington State: NC ZipCode: 28403 Phone(910) 799-2421 FAX: (910) 799-0361 5. Project Name: Rippv Cadillac Olds (Area Code and Number) (Area Code and Number) 6. Location of Project: (street address) 4951 New Centre Drive 7. Directions to Project (from nearest major intersection) from Intersection of US 17 Business and NC 132, take US 17 Business south to the intersection of New Centre Drive Turn left onto New Centre Drive. The site is on the left. at 4951 New Centre Drive II. PERMIT INFORMATION 1. Specify the type of stormwater treatment (wet pond, infiltration, etc.): Wet Pond 2. List any changes (from project that was originally approved, attach additional pages if needed) N/A 3. Do you have a copy of the original Operation and Maintenance Agreement? (]Y SIN Applicant's Certification: I, (print) R. Allen Rippv , certify that the information included on this permit renewal application, is to the best of my knowledge, correct and complete. Signature: Date: 5 • �`% Submit this completed form along with an application fee of $505.00 and a copy of the designer's certification to the address listed below. NooLCarolina ® Natmnz(lry North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: www.newateruuality.org Fax (910)350-2004 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer- 50% Recycledl10% Post Consumer Paper J. Phillip Norris, P.E. John S. Tunstall, P.E. NORRIS, KUSKE & TUNSTALL John A. Kuske, III, P.E. James T. Pyrtle, P.E. CONSULTING ENGINEERS ent P. Harrell, P.E. Philip Bev, Jr., P.E. , INC.. J.A.James L. Lewis, Jr., P.E. J.A. Kuske, P.E. 902 Market Street • Wilmington, NC 28401-4733 a Phone (910) 343-9653 a Fax (910) 343-9604 E-Mail: office@nkteng.com L€TTER OF TRANSMITTAL To: Mr. R. Allen Rippy Date: August 29, 2007 11 Job No. 07161 Rippy Cadillac Olds subject: Storm water Permit Renewal 4951 New Centre Drive Wilmington, NC 28403 WE ARE SENDING YOU VIA ® ATTACHED ❑ UNDER SEPARATE COVER ❑ SHOP DRAWINGS [--]PRINTS ❑ TRACINGS ❑ SPECIFICATIONS ❑ DISKS ❑ COPY OF LETTER ❑ FAX TRANSMITTAL: NUMBER OF PAGES INCLUDING T HiS TRANSMITTAL Call 910-343-9653 if you have any difficulty receiving this message. COPIES DATE NO. DESCRIPTION 1 Permit Application 1 Wet Detention Basin Operation & Maintenance Agreement 1 nesigner's Certification 1 Your check S ® PLEASE SIGN AND FORWARD ❑ FOR REVIEW AND COMMENT ❑ FOR APPROVAL ❑ FOR YOUR USE ❑ FOR BIDS DUE ❑ YOUR PRINTS LOANED TO US REMARKS: Please sign and have notarized as indicated on the Wet Detention Basin Operation and Maintenance Agreement. Forward the entire package to: NorthCarolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 CC: SIGNED J. Phillip Norris, P.E. / neh CONFIDENTIAL AND PRIVILEGED: Information contained in this document is privileged and confidential, intended for the sole use of the addressee. If you are not the addressee or the person responsible for delivering it to the addressee you are hereby notified that any dissemination, distribution or copying of this document is strictly prohibited. If you have received this document in error please immediately notify the sender and return to the address above. p� VVATFR (-,o c_ j + 1 — IV %�071&/ Michael F. Ea y William G. Ross Jr., Secretary S- North Carolina Department of Environment and Natural Resources SfS6 ZDZ, Ga 'C Alan W. Klimek, P.E. Director Division of Water Quality SURFACE WATER PROTECTION SECTION COASTAL STORMWATER PERMIT RENEWAL APPLICATION FORM I. CURRENT PERMIT INFORMATION: 1. Stormwater Management Permit Number: SW8 950202 2. Permit Holder's name: R & R Companv of Wilmington (company, partnership, corporation, LLC, or individual) 3. Signing official's name: R. Allen Rippv Title: Partner (person legally responsible for permit) 4. Mailing address: 4951 New Centre Drive City: Wilmington State: NC ZipCode: 28403 Phone(910) 799-2421 FAX; (910) 799-0361 (Area Code and Number) (Area Code and Number) 5. Project Name: Rippv Cadillac Olds 6. Location of Project: (street address) 4951 New Centre Drive 7. Directions to Project (from nearest major intersection) from Inter NC 132. take US 17 Business south to the intersection II. PERMIT INFORMATION Specify the type of stormwater treatment (wet pond, infiltration, etc.): Wet Pond 2. List any changes (from project that was originally approved, attach additional pages if needed) N/A siness and 3. Do you have a copy of the original Operation and Maintenance Agreement? DY RN Applicant's Certification: I, (print) R. Allen Rippv , certify that the information included on this permit renewal application, is to the best of my knowledge, correct and complete. Signature: q .— Date: �b •?- a� Submit this completed form along with an application fee of $505.00 and a copy of the designer's certification to the address listed below. ]VorthCarolina lVaturai�I, J North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: wwtiv.ncwaterauali�t.org Fax (910)350-2004 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer- 50% Recycled/10% Post Consumer Paper Michael F. Easley, Governor William G. Ross Jr., Secretary of Environment and Natural Resources Colecn H. Sullins, P.E. Director Division of Water Quality COASTAL STORMWATER PERMIT RENEWAL APPLICATION FORM I. CURRENT PERMIT INFORMATION: 1. Stormwater Management Permit Number:_ 6 A 2. Permit Holder's name:__ 1,6 9P er,.-" 0 A4,J - ��'�1 �� 0 V4 3. Signing official's name: Title: 4. r ermit) (person legally responsible f4157 Mailing address: 415 'Ale yJ ec- Al?�rc B %City: 1�p,�%gel �01 lly--• �ipCodet;?qfl/(J StallJPhonegjo 7 t?Jaw) FAX: i-1 a ®V1Q tee . t 5. ber) (Area Coded Number) (Area Code and Nre"id Project Name: �e-u��; o C- L" M F� 6. Location of Project: (street address Tb%% ; �/ AZe 7. Directions to Project (from nearest major intersection) /3,,4,' d U,/ ' ,5 G7�-sir "A o II. PERMIT INFORMATION Specify the type of stormwater treatment (wet pond, infiltration, etc.): i� �' i� C A)C/ 2. List any changes (from project that was originally approved, attach additional pages if needed) zy dr �. Do you have a copy of the original Operation and Maintenance Agreement? Yes —No ✓ Applicant's Certification: P 1, (print) f;"-Rt-c/ 4, 40e V- certify that the information included on this permit renewal p cation, is o he best of my knowledge, correct and complete. Signature: Date:' J®" 67 Submit this 6ompleted form along with an application fee of $420.00 and a copy of the desiqner's certification to the address listed below. 5 14WO ]ina �J/►V/ �([� North Carolina Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Phone (910) 796-7215 Customer Service Wilmington Regional Office Internet: www.ncwaterguality.om Fax (910) 350-2004 1-977-623-6748 NKT #07161 WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT Maintenance activities shall be performed as follows: 1. After every significant runoff producing rainfall event and at least monthly: a. Inspect the wet detention basin system for sediment accumulation, erosion, trash accumulation, vegetated cover, and general condition. b. Check and clear the orifice of any obstructions such that drawdown of temporary pool occurs within 2 to 5 days as designed. 2. Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash as needed. 3. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to maintain proper functioning. 4. Remove accumulated sediment from the wet detention basin system semi-annually or when depth is reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed of in an appropriate manner and shall be handled in a manner that will not adversely impact water quality (i.e. stockpiling near a wet detention basin or stream, etc.) The measuring device used to determine the sediment elevation shall be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the permanent pool depth reads When the permanent pool depth reads Sediment Removal El. 35.00 1 7 -----------f--- Bottom El vation 34.00 x FOREBAY 3.0 feet in the main pond, the sediment shall be removed. 3.0 feet in the forebay, the sediment shall be removed. BASIN DIAGRAM ill in the blanks) Permanent Pool Elevation 38.00 Sediment Removal Elevation 35.00 175% Bottom Elevation 34.00 MAIN POND 5. Remove cattails and other indigenous wetland plants when they cover 50% of the basin surface. These plants shall be encouraged to grow along the vegetated shelf and forebay berm. 6. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent practical. 7. All components of the wet detention basin system shall be maintained in good working order. • .L 8. Remove all trees and heavy woody vegetation from the basins and dike walls. I acknowledge and agree by my signature below that I am responsible for the performance of the seven maintenance procedures listed above. I agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print name: R. Allen Ripov Title: Partner Address: 4951 New Centre Drive, Wilmington, NC 28403 Phone: (910) 799-2421 Signature: (!QZ . Date: Ck'%4,- Orl Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. I,a Notary Public for the State of 1�a�ca.pc� County of :::R, A" , do hereby certify that Personally appeared before me this -1 day of , and acknowledge the due Execution of the foregoing wet detention basin maintenance requirements. Witness my hand and official seal. �,,aauuu•�,� za ARy``cc��`• 01 r Signature My commission expires �� 1 .01 Stormwater Proje Number SW8 V /r Project,Name W' Q& p e'404�6 ., i 3l County Designer's Certification I, JD/1A rfjil a►�� as a duly registered 44-55tonJ seer in the State of North Carolina, having been authorized to observe (period' IIy -weel ff+rrre) the construction of the project, (Project) -c . J for le + 1n%IAlln Project Owner) hereby state that, to the best of my abi sties, due care and d igence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. Required Items to be checked for this certification to be considered complete are on page 2 of this form. Noted deviations from approved plans and specifications: Signature Registration Number (JJW l Z i— A 11M Date j62 - 'L.AI - Page 1 of 2 Designer Certification Requirements: yt� The drainage area to the system contains approximately the permitted acreage. wZ'- The drainage area to the system contains no more than the permitted amount of built -upon area. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4 The outlet/bypass structure elevations are per the approved plan. The outlet structure is located per the approved plans. Trash rack is provided on the outlet/bypass structure. 7 All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. The inlets are located per the approved plans and do not cause short-circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. 11. Required drawdown devices are correctly sized per the approved plans. 12. I required design depths are provided. 13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 4. The dimensions of the system, per the approved plans, are provided. cc: NCDENR-DWQ County Building Inspections Page 2 of 2 WA�9Q Michael F. Easley, Governor �O� William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality July 11, 2007 Mr. R. Allen Rippy R & R Company Rippy Cadillac Olds 4951 New Centre Drive Wilmington, NC 28403 Subject:: Stormwater Permit No. SW8950202 Rippy Cadillac Olds New Hanover County Dear Mr. Rippy: The Division of Water Quality issued a Coastal Stormwater Management Permit, Number SW8950202 to R & R Company for a High Density pond to serve Rippy Cadillac Olds on 8/21/1996. This permit expired on 8/21/2006. Section .1003(h) of 15 A NCAC 2H .1000 (the storm water rules) requires that applications for permit renewals shall be submitted 180 days prior to the expiration of a permit and must be accompanied by a processing fee, which is currently set at $420.00. If this is still an active project please complete and submit the enclosed renewal application in a timely manner. If this project has not been constructed and a permit is no longer needed, please submit a request to have the permit rescinded. If you have sold the project, or are no longer the permittee, please provide the name, mailing address and phone number of the person or entity that is now responsible for this permit. Enclosed is a form for change of ownership, which should be completed and submitted if the property has changed hands. Your permit requires that upon completion of construction and prior to operation of the permitted treatment units a certification of completion be submitted to the Division from an appropriate designer for the system installed. This is to certify that the permitted facility has been installed in accordance with the permit, the approved plans, specifications and supporting documentation. Please include a copy of the certification with your permit renewal request and processing fee. Enclosed is a copy of a sample certification. Also enclosed is a new Operation and Maintenance agreement that should be completed and submitted along with your renewal application. You should be aware that failure to provide the Designer's Certification and the operation of a stormwater treatment facility without a valid permit, are violations of NC General Statute 143-215.1 and may result in appropriate enforcement action including the assessment of civil penalties of up to $10, 000 per day. If you have any questions, please feel free to contact staff in the stormwater group at 910-796-7215. Sin ely, Ed Beck, Regional Supervisor Surface Water Protection Section Wilmington Regional Office Enclosures cc: Wilmington Regional Office North Carolina Division of Water Quality Internet: www riewaterqualitv.org 127 Cardinal drive Extension Phone (910) 796-7215 Wilmington, NC 28403 Fax (910) 350-2004 NoithCarohna ;Vaturallty An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper A&K 96u6i DIVISION OF ENVIRONMENTAL MANAGEMENT NORTH CAROLINA STORMWATER MANAGEMENT PERMIT APPLICATION I. GENERAL INFORMATION 1. Project Name Rippy Olds Cadillac Parking Lot Expansion 2_ Vocation, directions to project (include County, Address, State Road) Attach map. New Hanover County, 4951 New Centre Drive, Wilmington, NC 28403 3. Owner's Name R. Allen Rippy, R&R Company Phone 4. Owner's Mailing Address 4951 New Centre Drive City Wilmington State 5. Application date 910-799-2421 NC Zip 28403 Fee enclosed $385.00 6. Nearest Receiving Stream UT Surnt Mill Creek Class C-swamp 7. Project description Parking lot expansion at existing car dealership." II. PERMIT INFORMATION 1. Permit No. cr. be fawa i. by pEhn 2. Permit Type New Renewal C x _ Modification (existing Permit No.) SW8 950202 3. Prcj Type _ Low Density x Detention _ Infiltration Other Redevelop _ Gen'l Dir Cert 4. Other State/Federal Permits/Approvals Required (awk appr ;.. blot.) CAMA Major Sedimentation/Erosion Control )( 404 Permit III. BUILT UPON AREA ctI.... NCAC z1.1005 ft. .1007 far ap U.W. densky OWI) Classification Allowable Impervious Area Total Project Area Proposed Impervious Area % Impervious Area Dra nave Ovid Total *Breakdown of Inervious Area Basin Ram (Pk= fadaft tomw nt deOp mptMous anca) C-SW C-SW Buildings Z9.940 �S�ts 3 Zc� 53 l 10.01 AC 4.01-A& 10. 01AC p g(9 2.89 AC-5. 22 Are 8.11 AC Other 28. 87% r2 5 - 81. 02% Totals 8.11 AC/353, 425 SF IV. STORMWATER TREATMENT cDw -whowffieiunwwmben *See calculations. The stormwater will be treated in a wet detention pond designed to meet 90% TSS removal. The existing detention pond is being expanded to treat the additional stormwater generated by the expansion. V. DEED RESTRICTIONS AND PROTECTIVE COVENANTS Deed restrictions and protective covenants are required to be recorded for all low density projects and all subdivisions prior to the sale of any lot. Please see Attachment A for the specific items that must be recorded for the type of project applied for. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the items required by the permit, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the covenant cannot be changed or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. III. OWNER'S CERTIFICATION I, R. Allen Rippy , certify that the information included on this permit (PI-e plat Q type — d-ly) application form is correct, that the project will be constructed in conformance with the approved plans, that the deed restrictions will be recorded with all required permit conditions, and that to the best of my knowledge, the proposed project complies with the requirements of 15A NCAC 2II.1000. I authorize the below named person or firm to submit stormwater plans on my behalf. VII. AGENT AUTHORIZATION (MUSS s$ COMR M) cc: Person Or firm name Andrew & Kuske Consulting Engineers , Inc. Mailing Address 202 North Fifth Avenue City Wilmington Mate NC Zip 28401 Phone 910-343-9653 Please submit application, fee, plans and calculations to the appropriate Regional Office. Applicant/WiRO/Central Files �T D E C E I V E JUN 261996 D PROJ #&—FY—V 26Z ,It