Loading...
HomeMy WebLinkAboutWQ0014306_Monitoring - 01-2021_20210225Monitoring Report Submittal ............................................................................................................................................ Permit Number #* WQ0014306 Name of Facility:* Eagle Creek Month:* January Report Information Type * NDMR, NDAR-1, NDAR-2, NDMLR Confirmation Email Address:* Name of Submitter:* Signature: Date of submittal: Initial Review Year:* 2021 Upload Document* Eagle Creek Binder.pdf 331.41 KB PDF= Only Please upload one PDF containing all applicable monitoring reports (i.e., NDMR, NDAR-t, NDAR-2, NDMLR, GW-59). rmanning@envirolinkinc.com Rebecca Manning Reviewer: Williams, Kendall 2/25/2021 This will be filled in automatically Is the project number correct? * WQ0014306 Is the monitoring report r Yes r No accepted?* Regional Office * Washington Accepted Date: 2/25/2021 FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: W00014306 Facility Name: Sandler Utilities, LLC-Eagle Creek County: Currituck Month: January Year: 2021 PPI: 001 Flow Measuring Point: ❑ Influent 0 Effluent [7] No Flow generated Parameter Monitoring Point: El Influent Effluent ❑Groundwater Lowering ❑Surface Water Parameter Code 10 50050 00310 00010 50060 31616 00610 00625 00620 00600 00400 00665 00630 00530 00076 00615 2 L G7 L C) O W I= a..1 F N U 0 0 LL f7 m i 7 N i Q E N ,� Y :G i N L U E L 6,i w LL 0 U 0 E Q L C N Y O :° Z F Y i Z C Y F O Z = N i 0 Y L ~ 0 s a } Y Y - Z Z N F 0 N N 7 F y Z 24-hr hrs GPD mg/L I °C mg/L #/100 mL mg/L mg/L mg/L mg/L su mg/L mg/L mg/L NTU mg/L 1 60,200 2 2 60,200 2 3 60,200 2 4 08:00 7 56,400 11.9 7.5 2.48 5 08:30 7.5 56,800 11.8 7.4 2.59 6 09:00 6 55,800 12.3 7.4 2.62 7 09:30 5 45,200 12.6 7.3 2.57 8 45,200 2.5 9 45,200 2.5 10 45,200 2.4 11 10:00 6.3 48,300 11.5 7.4 2.44 12 10:30 6.5 31,900 11.2 7.6 2.31 13 09:30 6 11,400 10.6 7.5 2.66 14 10:00 6 57,700 10.8 7.8 2.7 15 57,700 2.5 16 57,700 2.5 17 57,700 2 18 09:00 7.5 59,517 13.3 7.3 2.1 19 09:00 7.5 82,912 13.1 7.3 2.11 20 10:00 7 59,750 12.1 7.6 2.26 21 08:30 7 26,223 30 12 >2420 17.5 15.7 0.3 15.7 7.5 6.06 0.03 12 2.52 221 08:30 6 55,867 11.7 7.4 2.41 23 55,867 2.3 24 55,867 2.3 25 08:30 6 40,900 11.4 7.6 2.44 26 07:30 5 65,428 12 7.4 2.23 27 08:30 6 65,423 10.6 7.3 2.06 28 08:00 5 64,489 8 10.2 >2420 14.8 14.9 0.07 15 7.2 2.55 0.07 4 1.94 29 08:00 2 38,475 9.8 7.1 1.06 30 08:00 1.5 43,260 9.4 7.2 1.03 31 09:30 2 36,000 9.4 7.2 0.997 Average: 51,703 19.00 11.39 1.00 16.15 15.30 0.19 15.35 4.31 0.05 8.00 #REF! Daily Maximum: 82,912 30.00 13.30 0.00 17.50 15.70 0.30 15.70 7.80 6.06 0.07 12.00 #REF! Daily Minimum: 11,400 8.00 9.40 0.00 14.80 14.90 0.07 15.00 7.10 2.55 0.03 4.00 #REF! Sampling Type: Recorder Composite Grab Grab Grab Composite Composite Composite Composite Grab Composite Composite Composite Recorder Monthly Limit: 59,720 10 14 4 7 3 5 Daily Limit: 15 25 6 6-9 10 10 Sample Frequency: Continuous 2 X Month 5 X Week 5 X Week 2 X Month 2 X Month 2 X Month 2 X Month 2 X Month 5 X Week 2 X Month 3 X Year 2 X Month Continuous FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page ___ of Permit No.: WQ0014306 Facility Name: Sandler Utilities, LLC-Eagle Creek County: Currituck Month: January Flow Measuring Point: 71 Influent 7� Effluent No flow generated Parameter Monitoring Point: Influent Effluent Groundwater Lowering Surface Water • • more FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page of Permit No.: WQ001 4306 Facility Name: Sandier Utilities, LLC-Eagle Creek County: Currituck Month: January Flow Measuring Point: Influent Effluent No flow generated Parameter Monitoring Point: El Influent Effluent Groundwater Lowering Surface Water FORM: NDMR 05-16 NON -DISCHARGE MONITORING REPORT (NDMR) Page ___ of Sampling Person(s) Certified Laboratories Name: John Pruitt Name: Environmental Chemists #94 Name: Chris Allen Name: Does all monitoring data and sampling frequencies meet the requirements in Attachment A of your permit? ❑ Compliant VNon-Compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. EXCEEDED BOD, AMMONIA, AND TSS Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: John Pruitt Permittee: Sandler Utilities at Mill Run, LLC. - Eagle Creek Certification No.: 26021 Signing Official: Rebeca Manning Grade: WW-4 Phone Number: 910-539-9322 Signing Official's Title: Envirolink, Inc. Compliance Coordinator Has the ORC changed since the previous NDMR? ❑ Yes ❑ No Phone Number: 984-365-9155 Permit Expiration: 9/30/2020 n,.a... 2/23/2021 2/23/2021 Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 FORM: NDAR-1 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page of Permit No.: WQ0014306 Faci I ity Name: Sandler Utilities, LLC-Eagle Creek County: Currituck Month: January • irrigation occur at this facility? YES NO .. .. .. .. �0®©��00 • •• • •• 00 • •• • •• 00 • •• •• 00 • •• • •• FORM: NDAR-1 10-13 NON -DISCHARGE APPLICATION REPORT (NDAR-1) Page of Did the application rates exceed the limits in Attachment B of your permit? ❑ compliant ❑ Non -compliant Were adequate measures taken to prevent effluent ponding in or runoff from the sites? ❑ compliant ❑ Non -compliant Was a suitable vegetative cover maintained on all sites as specified in your permit? ❑ compliant ❑ Non -compliant Were all setbacks listed in your permit maintained for every application to each permitted site? ❑ compliant ❑ Non -compliant Were all freeboards maintained in accordance with the specified freeboard heights in your permit? ❑ compliant ❑ Non -compliant If the facility is non -compliant, please explain in the space below the reason(s) the facility was not in compliance. Provide in your explanation the date(s) of the non-compliance and describe the corrective action(s) taken. Attach additional sheets if necessary. Operator in Responsible Charge (ORC) Certification Permittee Certification ORC: John Pruitt Permittee: Sandler Utilities at Mille Run, LLC -Eagle Creek Certification No.: 26021 Signing Official: Rebecca Manning Grade: WW4 Phone Number: 910-53-9322 Signing Official's Title: Envirolink, Inc. Compliance Coordinator Has the ORC changed since the previous NDAR-1? ❑ Yes ❑ No Phone Number: 984-365-9155 Permit Exp.: 9/30/20 2/25/2021 2/25/2021 Signature Date Signature Date By this signature, I certify that this report is accurrate and complete to the best of my knowledge. I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that all qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations. Mail Original and Two Copies to: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617