Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0042326_Application (FTSE)_20210216
TRANSMITTAL URBAN DESIGN PARTNERS To: Debbie Luckman Date: Mooresville Regional Office Water Quality Section 610 East Center Ave Ste 301 Mooresville, NC 28115 Phone: 704-663-1699 Project Name: 1454 Sardis Townes Fax: Project No: 20-CLT-037 1213 w morehead street, suite 450 P 704.334.3303 charlotte, nc 28208 urbandesignpartners.com RECEIVED/NCDEO/DWR FEB 1 6 2021 WOROS MOORESVILLE REGIONAL OFFICE 2/12/2021 Transmitted Via: Action: ❑ Overnight Courier Hand Mail Fax ❑ For Approval ® For Your Use ❑ As Requested ❑ For Review & Comment ❑ For Signature Number Date Description 1 Check for $480 1 Cover Letter Comments Let me know if you need anything else. Darvin Wilson darvin@urbandesignpartners.com Cc: RECEIVED/NCDEQ/DWR FEB 1 6 2021 WQROS MOORESVILLE REGIONAL OFFICE 1454 Sardis Townes Fast Track Application Cover Letter UDP PROJECT NO: 20-CLT-037 Applicant Kinger Homes, LLC Dhanesh Kumar 215 N. Pine Street, Unit 2011 Charlotte, NC 28202 (704) 659-6705 Project Location 1454 Sardis Rd. N, Charlotte, NC 28270 Engineer Urban Design Partners Brian D. Smith, P.E. 1213 W. Morehead St., Suite 450 Charlotte, NC 28208 (704) 334-3303 (704) 334-3305 (fax) Project Description Kinger Homes, LLC is constructing 2 buildings (13 townhomes) for multi -family residential use on the 0.87 acre site. The buildings will be served by a private sanitary sewer and water main. The private sewer and water lines connect to existing water and sewer mains along Sardis Road North. The private sanitary sewer project requested flow acceptance through Charlotte Water for the 13 townhomes in the amount of 2,470 gallons per day and was accepted. This project includes the installation of 17 LF of 2-inch PVC private domestic water from the meter to the backflow. An additional 66 LF of 2-inch domestic water line and 59 LF of 6-inch fire line will be installed to provide service to the buildings for sprinkler systems. The project also includes the installation of 208 LF of 8" PVC sanitary sewer line. See the attached utility plan for reference. 1213 w morehead street, suite 450 P 704.334.3303 charlotte, nc 28208 urbandesignpartners.com URBAN TRANSMITTAL DESIGN PARTNERS To: Barry Love - NCDEQ Date: Mooresville Regional Office Water Quality Section 610 East Center Ave, Ste 301 Mooresville, NC 28115 Phone: 704-663-1699 Project Name: 1454 Sardis Townes Fax: RECEIVD/NCDEQ/DWR JAN\IN7021 1 /26/2(��� WQROS lY1VORESVILLE REGIO L OFFICE Project No: 20-CLT-037 Transmitted Via: ❑ Overnight ❑ Courier ❑ Hand ❑ Mail ❑ Fax Action: For Approval ❑ For Your Use ❑ As Requested ❑ For Review & Comment ❑ For Signature RECEIVED/NCDEQ/DWR FEB 16 2021 WQROS MOORESVILLE REGIONAL OFFICE Number Date Description 1 01.26.2021 Cover Letter 2 01.26.2021 Fast Track Applications (1 original and 1 copy) 1 01.26.2021 CLT Water FA Letter and FTSE Letter 1 01.26.2021 Water Calculations Report 1 01.26.2021 Site Map 1 01.26.2021 Street Level Map 1 01.26.2021 Topo Map 2 01.26.2021 Full Size Private Sewer Utility Plan Comments Please let me know if you have any questions Darvin Wilson Cc: 1454 Sardis Townes Fast Track Application Cover Letter UDP PROJECT NO: 20-CLT-037 Applicant Kinger Homes, LLC Dhanesh Kumar 215 N. Pine Street, Unit 2011 Charlotte, NC 28202 (704) 659-6705 Project Location 1454 Sardis Rd. N, Charlotte, NC 28270 Engineer Urban Design Partners Brian D. Smith, P.E. 1213 W. Morehead St., Suite 450 Charlotte, NC 28208 (704) 334-3303 (704) 334-3305 (fax) Project Description Kinger Homes, LLC is constructing 2 buildings (13 townhomes) for multi -family residential use on the 0.87 acre site. The buildings will be served by a private sanitary sewer and water main. The private sewer and water lines connect to existing water and sewer mains along Sardis Road North. The private sanitary sewer project requested flow acceptance through Charlotte Water for the 13 townhomes in the amount of 2,470 gallons per day and was accepted. This project includes the installation of 17 LF of 2-inch PVC private domestic water from the meter to the backflow. An additional 66 LF of 2-inch domestic water line and 59 LF of 6-inch fire line will be installed to provide service to the buildings for sprinkler systems. The project also includes the installation of 208 LF of 8" PVC sanitary sewer line. See the attached utility plan for reference. uuuu..`iyl l CI IvelupC I0. JUL/0.0CJ / -L,or / -'+o r-,- / r-/ ru I I uMUOC4,- Division of Water Resources RECEIVED/NCDEQ/DWR . ICAI' .0300 - WORns ItbVILLE REGIONAL OFFI Application Number: State of North Carolina Department of Environmental Quality Division of Water Resources FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION (Ua4677kbe completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Kinger Homes, LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ individual ® Corporation ❑ General Partnership ❑ Federal ❑ State/County ❑ Municipal 3. Signature authority's name: Dhanesh Kumar per 15A NCAC 02T .0106(b) Title: Owner 4. Applicant's mailing address: 215 N. Pine Street, Unit 2011 City: Charlotte State: NC Zip: 28202- 5. Applicant's contact information: Phone number: (704) 659-6705 Email Address: Dhanesh@KingerHomes.com H. PROJECT INFORMATION: 1. Project name: 1454 Sardis Townes 2. Application/Project status: ® Proposed (New Permit) If a modification, provide the existing permit number: WQ00 RE • IVED/NCDEQ/DWR WQRO MOORESVILLE REGIO L OFFICE ❑ Privately -Owned Public U'lity R rVFO ❑ Other -E3182021 M©ORESVILWOROS LE REGIONAL 0 ❑ Existing Permit/Project and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.1384' Longitude: -80.7408' 5. Parcel ID (if applicable): 213-221-05 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Brian Smith License Number: 049245 Firm: Urban Design Partners Mailing address: 1213 W. Morehead St, Suite 450 City: Charlotte State: NC Zip: 28208- Phone number: (704) 334-3303 Email Address: Brian@UrbanDesignPartners.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek Permit Number: NC0024970, NC0024945, NC0024937 Owner Name: Keri Cantrell V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): inch FORM: FTA 04-16 Page 1 of 5 V UGU C11l`f.l l Cllvelope IL/. JL/LJO,Ca/-1,Dr 7-4oCr-/1L t r-1 ro I ivaooD,rr% VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ® Residential Leased ❑ Retail with food preparation/service ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Food and drink facilities ❑ Church ❑ Businesses / offices / factories ❑ Nursing Home ❑ Car Wash ❑ Hotel and/or Motels ❑ Swimming Pool /Clubhouse ❑ Swimming Pool/Filter Backwash ❑ Other (Explain in Attachment) 5. Nature of wastewater : 100 % Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) >ls there a Pretreatment Program in effect? ❑ Yes ® No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ® No ➢ If Yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow a,b No. of Units Flow Single Family Townhome Residential 190 gal/day/unit 13 2,470 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 2,470 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 2,470 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line El Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 uuVu.Dlyi l cI iv iupe lu. Jvuo�ca r -L or r -,+oc r-/1u r-r ru 1 I VyVoo'Ihi VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 208 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(11: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 uul.u.?lyll r-! ru 1 IU UDD4H IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): I. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ➢ 1 NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: ® Yes ❑ No Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I5A NCAC 02B .0200? ❑ Yes ❑ No ® N/A ➢ This would include Trout Buffered Streams per ISA NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch Yes ® No 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per I SA NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 LJUUU.D- IJ. I 1 CI I VCIUi)C IIJ. ru I I U.'IUDO9./'1 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version). and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: Brian Smith 1, (Professional Engineer's name from Application Item 111.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): Dhanesh Kumar I, (Signature Authority's name & title from Application Item I.3.) attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: r—DocuSigned by: Wal tA,s(t, v-uwtaY `— E464939456994C7... Date: 1/25/2021 FORM: FTA 04-16 Page 5 of 5 CHARLOTTE August 25, 2020 Mr. Darvin Wilson Urban Design Partners 1318 — E6 Central Avenue Charlotte, NC 28205 SUBJECT: WATER AND SEWER FLOW ACCEPTANCE 1454 SARDIS TOWNES 1454 SARDIS ROAD N., CHARLOTTE, NC 28270 CLTWATER TRACKING# 20204292 RECEIVED/NCOECV i JAN ' 7 'O21 MOOPESVILWROS LE REG ONAL OFFICE After analysis of the sanitary sewer associated with the proposed project, 20204292, 1454 SARDIS TOWNES, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 2,470 gallons per day (13 units x 190 gpd/unit) at the connection point(s) indicated on the submitted utility plan for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. Please see attached NCDEQ-FTSE form. Charlotte Water (CLTWater) agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986 and The Water Supply Management Plan, PWS ID # 0160010 on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. The applicant should understand that due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct or extend private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained and construction has not started within two (2) years of issuance of this flow acceptance, and payment for any service connections have not been received within two (2) years of issuance of this flow acceptance letter, this flow acceptance approval shall be rescinded and a new flow acceptance request must be made. If you have any questions, please do not hesitate to contact me at (704) 432-5801. Sincerely, wi,U, .rww- Awzo-Ca, Guillermo Anzola Engineering Assistant Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org Kt» Operated by the City of Charlotte RECEIVED/NCDEQ/DWR JAN 2 7 2021 WOROS MOORESVILLE REGIONAL OFFICE State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Urban Design Partners Project Name for which flow is being requested: 1454 Sardis Townes More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NC0024970, NC0024945, NC0024937 All flows are in MGD c. WWTP facility's permitted flow 99.00 d. Estimated obligated flow not yet tributary to the WWTP 10.273 e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used 73.817 0.00247 84.090 84.9% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station (Name or Permit Number) No. Firm Capacity, * MGD (A) Design Average Daily Flow** (Firm / pf), MGD (B) (C) Obligated, Approx. Not Yet Current Tributary Avg. Daily Daily Flow, Flow, MGD MGD (D)=(B+C) (E)=(A-D) Total Current Flow Plus Obligated Flow Available Capacity*** * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Sardis Road North Downstream Permit Number: 196-550 Page 1 of 6 FTSE 10-18 III. Certification Statement: Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature Chief Engineer Title of Signing Official 8/25/2020 Date Page 2 of 6 FTSE 10-18 Nc� a m 3 m 00 • a = s o • 3 3 m m a -o 0 m o N m a - 0 • ° o m o O • C' o o m -, (D N CD M • 7 < a ° m m o▪ _o • o o CD D) a 5' 3 � 3 ,< < O • _. a 7 a C !7 O (D a 3 D) (O 0 -. O O C O O N � O O_' -• 6 N n O ° C N co (D O d O " • O n3 cr (D o (D n O O p. 7 (D c °' — a (p (D a (D „ o. O N <-o (D D) m v o • 3 -oo co .0 • w m O-• O C 0 o O C _ � 3 `< (D N � CL • (j 3 • 03 pl m a o a• (° 0 0 O (D • ~ 03 qa C 0 0- O �j to co 0')0 c C O_ 3 (D CD O 3 0 Q (D N CO N . Date Printed: 1/20/2021 9:26:17 AM -1 a � N RECEIVED/NC?EQ!DWR JAN ' 'I 2U21 WATER CALCULATIONS WORDS MOORESVILLE REGIONAL OFFICE FOR ARMS I •WN 1454 Sardis Road North, Charlotte, North Carolina 28270 Kinger Homes, LLC 215 N. Pine Street, Unit 2011 Charlotte, NC 28202 Date: 11 /11 /2020 Revised: 1318 Central Avenue, Suite E6 Charlotte, NC 28205 NCBELS Firm #: P-0418 SC COA #: C-03044 Project No: 20-CLT-037 Calculations By: DJW 1454 Sardis Townes WATER CALCS UDP PROJECT No: 20-CLT-037 PROJECT LOCATION 1454 Sardis Rd. N, Charlotte, NC 28270 PROJECT DESCRIPTION Kinger Homes, LLC is constructing 2 buildings (13 townhomes) for multi -family residential use on the 0.87 acre site. The buildings will be served by a private sanitary sewer and water main. The private sewer and water lines connect to existing water and sewer mains along Sardis Road North. This project includes the installation of 17 LF of 2-inch PVC private domestic water from the meter to the backflow. An additional 66 LF of 2-inch domestic water line and 59 LF of 6-inch fire line will be installed to provide service to the buildings for sprinkler systems. The following water model calculations were performed by placing the fire flow plus peak demand at the furthest building to verify that the minimum pressure of 20 psi throughout the water distribution system was achieved. Water Layout PEA,l D M, ND WITH 1 E L W NODES.ti Head Pressure Elevation Base Demand Node ID ft GPM ft psi Junc 3 680.00 0.00 847.80 72.71 Junc 4 681.08 0.00 845.16 71.10 Junc 5 688.85 0.00 845.10 67.70 Junc 6 688.85 0.00 842.74 66.68 Junc BLDG2-6 689.33 1000.00 840.91 65.68 Junc BLDG2-2 689.33 2.63 845.09 67.49 Junc BLDG1-2 689.33 1.65 845.10 67.49 Junc BLDG1-6 689.33 0.00 842.74 66.47 Junc 2 678.00 0.00 849.31 74.23 Resvr 1 680.50 #N/A 680.50 0.00 j PIA � DWITHFi _ K Unit Headloss Friction Factor Flow ` Velocity Link ID GPM fps ft/Kft Pipe 2 803.42 9.12 57.35 0.022 Pipe 3 3.42 0.35 0.49 0.043 Pipe 4 1.32 0.13 0.09 0.051 Pipe 5 800.00 9.08 56.90 0.022 Pipe 6 0.00 0.00 0.00 0.000 Pipe 7 800.00 9.08 56.90 0.022 Pipe 8 2.10 0.21 0.20 0.046 Pipe 9 803.42 5.13 14.12 0.023 Pump 1 803.42 0.00 -168.81 0.000 Hydrant Number: 104403 Station: Station 29 Charlotte Fire Department Fire Hydrant Flow Request Form 500 Dalton Avenue Charlotte, NC 28206 (704) 336-2101 Hydrant Mfg.: AM DARLG Shift: C Address: 1300 SARDIS RD NO (Confirm numeric address is on correct side of street) -80.7423087 Map Y: 35.13849505 Map X: Type/Owner: PUBLIC Flow Test Data: Date Tested: 08/19/2020 07:30:00 Main Size: 8 Street Gate Value: Coefficient Static psi Res. PSI Flow PSI 2 1/2" Flow GPM Flow @ 20Res Flow @ ORes 9 120 60 36 1006.74 1326.53 1463.77 48hr High 48hr Low 48hr Average 134 98 118 Test Remarks Project Name: 1454 Sardis Rd N Project Address: 1454 Sardis Rd N, Charlotte Nc 28270 Company Requesting: Urban Design Partners Company Address: 1318 E-6 central Ave, Charlotte NC 28205 Name of Contact: Darvin Wilson Telephone Number: 704-334-3303 Cell Number: Email: darvin@urbandesignpartners.com Purpose Of Test: Single Hydrant Fire Flow/ 48Hrs Tested By: George Lutz Test Time: 07:15 HydrantPublicRelease Page 1 of 1 Created @ 8/19/2020 2:22:46 PM