Loading...
HomeMy WebLinkAboutNC0086827_Renewal (Application)_20210220 a��srA ROY COOPER •I ,,t, ,I,.. .,_, SGovernor ra MICHAEL S.REGAN ` _^;0•, ' Secretary S.DANIEL SMITH NORTH CAROLINA Director Environmental Quality February 20, 2021 Brenntag Mid-South, Inc. Attn: David Grenoble, District Manager 2000 E Petigrew St Durham, NC 27703-4049 Subject: Permit Renewal • Application No. NC0086827 Brenntag/ Durham remediation Durham County Dear Applicant: The Water Quality Permitting Section acknowledges the February 19, 2021 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150E-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit.The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely, _sUI ,+ 4: Wren Th-•ford Administrative Assistant Water Quality Permitting Section cc: James Shilliday-ARCADIS ec: WQPS Laserfiche File w/application D E --\ -"---------- North Cs. D.pertrnentofEnv:ronrn=ntelQ until v I Div�s:onoflYsterR sou roes ✓��) fila;ah fieaansl nffe_ 38DD Berrett Drrva I el�h,North Csrcl:ns 276C9 is ''' .:' m u 919-M1-4200 1Rc1DJS Arcadis G&M of North Carolina, Infrastructure, environment, buildings Inc. 5420 Wade Park Boulevard, Ms.Wren Thedford Suite 350 NC DEQ—Division of Water Resources Raleigh NPDES Unit North Carolina 27607 1617 Mail Service Center Tel 919.415.2302 Fax 919.233.1125 Raleigh, NC 27699-1617 g www.arcadis-us.com Subject. ENVIRONMENT NPDES Permit Renewal Application(NPDES Permit NC0086827), Groundwater Remediation System, Brenntag Mid-South, Inc., Durham, North Carolina. Dear Ms. Thedford: Date: February 19, 2021 On behalf of Brenntag Mid-South, Inc. (Brenntag),Arcadis G&M of North Carolina, Inc. (Arcadis)is submitting the attached National Pollutant Discharge Elimination Contact. System(NPDES)permit renewal application for the continued discharge of effluent Jim Shilliday from a groundwater remediation system at the Brenntag facility(former Southchem facility)in Durham, North Carolina(NPDES Permit NC0086827). Treated Phone: groundwater from the remediation system is discharged to an on-site storm sewer 919.415.2302 that, in turn, discharges to a drainage ditch located along the southern boundary of Email: the site. This drainage ditch conveys surface water to an unnamed tributary of Third Jim.Shilliday@arcadis.com Fork Creek. No changes have been implemented to the groundwater remediation system since issuance of the previous NPDES Permit on November 1, 2016. our ref: 30065852 We have one requested revision to the NPDES Permit. We would like to remove bis(2-ethylhexyl)phthalate from the required parameter list. This compound is problematic for a variety of reasons as noted below. We reviewed the effluent results all the way back to when we first started collecting NPDES samples in 2002, and it does not appear that we have ever detected this compound above the current discharge limit of 1.2 micrograms per liter(pg/L). We have included with this submittal Table 1 which provides a summary of the treatment system effluent results for the period of November 2016 through December 2020(the effective period of the existing NPDES Permit). As can be seen on Table 1, bis(2-ethylhexyl)phthalate has been detected twice during this 4 year period, and both detections were estimated values(0.68J and 0.11J pg/L)occurring below the discharge limit of 1.2 pg/L. In addition,the laboratory that performs all the analyses for our NPDES samples (Eurofins TestAmerica)has detected bis(2-ethylhexyl)phthalate in the method blanks for samples collected in the past. In communications with Eurofins TestAmerica, they have confirmed that bis(2-ethylhexyl)phthalate is a problematic analyte. They provided several references documenting that bis(2-ethylhexyl)phthalate can be an artifact resulting from both sample collection and/or analysis procedures due to its ubiquitous presence in plastics and a variety of other consumer and industrial products. Our concern is that any future detection of bis(2-ethylhexyl)phthalate Imagine the result ARCADIS Ms.Wren Thedford February 19, 2021 would most likely be an artifact of sample collection or sample analysis procedures, and yet this is often very difficult to prove. So for the reasons noted above,we would like to request the elimination of bis(2-ethylhexyl)phthalate)from future permit monitoring requirements. Please note that sludge is neither generated nor discharged by the groundwater remediation system;therefore, a sludge management plan has not been included with this application. Any solids(e.g. silt, iron and manganese precipitate)generated during the groundwater extraction and/or treatment processes are filtered from the treatment stream using bag filters and granular activated carbon units. The treated effluent is sampled on a monthly basis for total suspended solids in accordance with the monitoring requirements for the site. Other items enclosed with this letter in support of the NPDES permit renewal application include the following: • Table 1 —summary of the effluent sampling results for a 4 year period between January 2017 through December 2020 supporting the requested reduction of sampling parameters discussed in this letter; • Figure 1 - USGS topographic map of the project area that depicts the location of the system outfall; • Figure 2-site map that depicts the route of the treated water to the discharge point. If you have any questions regarding the information presented in the NPDES permit application or any of the supporting material, please call me at(919)415-2302. Sincerely, Arcadis G&M of North Carolina, Inc. G ames E. Shilliday, Ill, L.G. Principal Scientist, Project Manager Copies: Mr. David Grenoble(Brenntag Mid-South) Page: 2/2 NPDES PERMIT APPLICATION - SHORT FORM C - GW For discharges associated with groundwater treatment facilities. Mail the complete application to: N. C. Department of Environment and Natural Resources Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number NC0086827 If you are completing this form in computer use the TAB key or the up-down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise,please print or type. 1. Contact Information: Owner Name David Grenoble Facility Name Brerintag Mid-South, Inc. Mailing Address 2000 East Pettigrew Street City Durham State / Zip Code North Carolina 27703 Telephone Number (270)869-5806 Fax Number ( ) e-mail Address dgrenoble@brenntag.coin 2. Location of facility producing discharge: Check here if same as above Street Address or State Road City State / Zip Code County 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Arcadia (attn: Jim Shilliday) Mailing Address 5420 Wade Park Boulevard, Suite 350 City Raleigh State / Zip Code North Carolina 27607 Telephone Number (919)415 2302 Fax Number (919)233 1125 4. Ownership Status: Federal ❑ State ❑ Private® Public ❑ Page 1 of 3 GGW 03105 NPDES PERMIT APPLICATION = SHORT FORM C - GW For discharges associated with groundwater treatment facilities. 5. Products recovered: Gasoline ❑ Diesel fuel D Solvents ® Other chlorinated and nonchlorinated solvents 6. Number of separate discharge points: 1 Outfall Identification number(s) 001 7. Frequency of discharge: Continuous ® Intermittent ❑ If intermittent: Days per week discharge occurs: Duration: 8. Treatment System Design flow 0.0144 MGD 9. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Unnamed Tributary(Intermittent) of Third Fork Creek 35 58 45.76N 78 52 56.38W 10. Please list all additives to the treatment system,including chemicals or nutrients, that have the potential to be discharged. No chemical additives are addeded to the treatment system 11. Is this facility located on Indian country? (check one) Yes ❑ No Ei 12. Additional Information All applicants (including renewals): > A USGS topographical map (or copy of the relevant portion)which shows all outfalls ➢ A summary of the most recent analytical result s (effluent data, if available) containing the maximum values for each chemical detected NEW Applicants only: > Engineering Alternative Analysis ➢ Description of remediation treatment system components, capacities, and removal efficiency for detected compounds. > If the treatment system will discharge to a storm sewer, written approval from the municipality responsible for the sewer. > A list of any chemicals found in detectable amounts at the site,with the maximum observed concentration reported for each chemical (the most recent sample must be collected less than one year prior to the date of this application) > For petroleum-contaminated sites-Analyses for Volatile Organic Compounds (VOC) should be performed. Analyses for any fuel additives likely to be present at the site and for phenol and lead should also be performed. Page 2 of 3 C-GW 03/05 NPDES PERMIT APPLICATION - SHORT FORM C - GW For discharges associated with groundwater treatment facilities. For sites contaminated with solvents or other contaminants - EPA Method 624/625 analysis should be performed. 13. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. David Grenoble District SRO Manager Printed name of Person Signing Title February 18, 2021 Sigrtlof A�p¢�cant Date North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 3 of 3 C-GW 03/05 Table 1.Historic Effluent Sampling Results,Brenntag Mid-South(Former Southchem)Facility,Durham,North Carolina. NPDES permit NC0086827 Frequency: Monthly Parameters Quarterly Parameters Method: 2540D 4500 8260D 8270E 1664A VOCs 8260D Bis(2- Oil& Chronic Constituents: TSS pH Acetone ethylhexyl) Grease Benzene 1,1-DCE PCE Toluene TCE VC Xylenes Toxicity Comments phthalate Units: mq/L SU mq,/L uq/L mq/L uq/L uq/L uq/L uq/L uq/L uq/L uq/L pass/fail Limits: 30 6.0-9.0 2.0 1.2 -- -- - - - - - - PIP(90%) 11/16/2016 1.0 8.1 0.720 <0.98 NA <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <2.0 NA 12/21/2016 <1.0 8.2 0.032 <1.0 NA NA NA NA NA NA NA NA NA 1/31/2017 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 2/21/2017 1.3 7.7 0.011 <0.97 <4.9 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 3/24/2017 2.1 7.7 0.025 <0.49 NA NA NA NA NA NA NA NA NA 4/25/2017 2.3 7.6 0.040 <0.96 <4.8 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 fall 5/9/2017 <1.0 7.8 0.025 <0.96 NA NA NA NA NA NA NA <1.0 pass 6/27/2017 <1.0 8.1 <0.010 <0.97 NA NA NA NA NA NA NA NA pass 7/25/2017 4.4 8.3 <0.010 <0.95 <4.8 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 8/21/2017 3.9 7.8 <0.010 <1.1 NA NA NA NA NA NA NA NA NA 9/21/2017 1.4 8.7 <0.010 <0.95 NA NA NA NA NA NA NA NA NA 10/31/2017 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 11/30/2017 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 12/11/2017 <1.0 8.3 0.150 <0.95 <4.6 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 NA 1/31/2018 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 2/28/2018 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 3/9/2018 1.2 8.0 <0.010 <0.96 <4.7 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 NA 4/24/2018 2.6 8.0 0.021 <0.95 <5.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 5/25/2018 2.9 7.9 <0.010 <1.0 NA NA NA NA NA NA NA NA NA 6/27/2018 2.2 8.3 <0.010 <0.95 NA NA NA NA NA NA NA NA NA 7/24/2018 1.2 8.1 0.079 <1.1 <4.7 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 8/29/2018 <1.0 8.0 <0.010 <0.96 NA NA NA NA NA NA NA NA NA 9/25/2018 3.1 7.9 0.010 <0.96 NA NA NA NA NA NA NA NA NA 10/31,2018 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 11'30,2018 NS NS NS NS NS NS NS NS NS NS NS NS NS No FI-- 12/17/2018 <1.0 8.3 0.110 <0.95 <4.7 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 NA 1/29/2019 <2.0 8.4 0.053 <0.94 <4.6 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 2/25/2019 2.8 8.4 0.018 <0.56 NA NA NA NA NA NA NA NA NA 3/27/2019 5.6 8.3 0.014 <0.54 NA NA NA NA NA NA NA NA NA 4/23/2019 1.0 8.0 0.052 <0.54 <4.8 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 5/30/2019 18 8.2 0.033 <10 NA NA NA NA NA NA NA NA NA 6/27/2019 11 8.1 <0.010 0.68 J NA NA NA NA NA NA NA NA NA 7/23/2019 <3.3 8.3 <0.010 <0.53 <4.8 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 8/27/2019 <1.0 7.9 0.019 <0.64 NA NA NA NA NA NA NA NA NA 9/19/2019 5.2 8.0 <0.010 <0.54 NA NA NA NA NA NA NA NA NA 10/22/2019 <1.0 8.4 0.064 <0.55 <1.3 <0.43 <0.36 <0.74 <0.48 <0.48 <0.50 <0.23 pass 11/26/2019 1.5 8.6 0.250 <0.53 NA <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <2.0 NA 12/17/2019 1.0 8.7 <0.010 <9.7 NA NA NA NA NA NA NA NA NA 1/31/2020 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 2/28/2020 NS NS NS NS NS NS NS NS NS NS NS NS NS No Flow 3/24/2020 1.0 8.1 1.200 <0.54 NA <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 NA 4/21/2020 2.6 8.2 0.088 <0.58 <4.9 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 5/18/2020 <1.0 7.9 0.087 0.11 J NA NA NA NA NA NA NA NA NA 6/22/2020 1.3 7.8 0.180 <1.0 NA NA NA NA NA NA NA NA NA 7/28/2020 1.1 7.2 3.2 <0.96 <4.7 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 8/27/2020 <1.0 7.6 0.100 <0.93 NA NA NA NA NA NA NA NA NA 9/30/2020 2.1 7.5 0.140 <0.93 NA NA NA NA NA NA NA NA NA 10/27/2020 1.6 7.5 <0.01 <2.0 <5.2 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 pass 11/24/2020 1.7 7.5 <0.025 <0.94 NA <1.0 <1.0 <1.0 <1.0 <1.0 <1.0 <2.0 12/31/2020 NS NS NS NS NS NS NS NS NS NS NS NS N' . - --• --' .,•• •• -•••-• 3 I ••••.''r- I 2'raw-- *•,,,oi- s' "" 'ill I ; ' '• 3°- :-.1+1 •' '''1 -&-.- .:‘14—:17-64P11:444:itf' .4/2'141,4 ..1...:,0:*,S117,,,,311111 i •r•1111; ‘)- ilY1-dk-IP' I/ /°(' ,:-.:.,-'7. ,Itir-''.04A-. f 4',..'' pAlM, .di4rtNqy ( g Trr . -- —1m ia 1, - —, 4",1%•....•v6.,:k,..v=.7,;-:.,'!i!i..,e,.1• );, ( 0,4.v t N-m4.,1-mit,,,wirlitterts: !Firip)-0.......74m1,- 1.4.4.irtiett24::,;:- .T, / , g < I,-'-*I.i:-Nl-.4k.i..,.-j,iE1r41;'nA•N',-•'s•-‘,‘p..6.,,L..•,.•,%Ei•,,,._c(,l f!.4‘1'i''.‹1$0N„4 ,‘\\kiVial.i li.i.i.al;cp•s)a%..l.,i7:d,.,0 11.1;!A 61m,,•.,,, *,- *,,',, ,k0, 1,'.',\a-1,-,'a111"''*‘M1.1''1'''1 E-1L. 'r.vA-71-t.ri,'.i16...;1'.0A•tt/4l1.arM„O 4OiPfif".. J.:'?0,11.4•r1 ' ff-ai cm4'.r 1\—•4--Y 1',:-•0--.``t&'N•i'ir\_•,-_4;o_k:..,.t`.'-.' b 4 SITE LOCATION r4 % ; .4-r:tP/.',iim ,. gl-li sVtf' iv\ -\ , ,.:Wif, VIFIT*It ,v16 * Z N144.167Wartilae 111 • ' -7 s„ i'' , 4k, —., -.r,, .,cm N-AO ikt,a .',,., * . A'fAi„.. ., it...4.iii g' ,,, fa" ,, r, / Litiii\\•,, , . _ ,k._ 1 EA-alrf'4.7 -d..- -- - •L . kb`\ It7/.- \Vi''--, ,1470404/:.ilir. ---*--.1' je \ --;, / • 1 -4—'8, '/A.-- 4, ''11 4,, ...44 t "%.• . 0 ...'- , :'.-INC../01161,1611141,,;(,5-11A. $75...k fl'":;,-jc I ....--_‘./. li -144i4i--'•:14/(V.-4 $ % .- - ' '''. 4. `Iii'' ., I 144114-7./e , F1' • - y.,15 I','‘ . -:,-',/* ‘\3. 1\_/'----"- ,,,_ ilerte:..,p;•,. .-.7 Cf4,Arr ' C' ,,, i ,,1,--:'-_-:,-' ,...... /1 ';io-4s._ /Pik* ' ,•KR-f---- ti? ,..-/ i-'4:11-1.': Y+ - ..... .." 4 0, ---,-- 4 i , ...., \ •••.91riailiti4r4.,,,4, ity#.5-4,4 A:-4, (,, ,,....,,,Als,,,i,. ,_ /., , 1,.7._•ma,„,114, _.._._ i ,4,1741 ),,A,-- ,e1, if .`' -...-41q,,. 41111:,:nr 4,-\ ,. . .4iiri.if /,, 41--, , N rw„,......„-liw __A --,,,,f) •,,..71114, As \,-‘,,, =240i-, e;difir sp,..,...„, __,,,/ f do,.... .1 P - - - •-• __'o "I.•- ..) r -..) ma ''' in•. ,1., 4-.1 I, , 1)L, -,-,, , 01. --:-.:',.';',er,'',•;-' ‘1 \i.` -WI' i_.-/ I 's • pii, , Discharge Point •, ..-7-4-,--i _.-1 ,ita—,,,:i 'Sks, 'N-,,, --- ,Z.•),,in't-. 7) -,` 4 , 7' §L,1-1-r--N'-; ).-kiy le i ? I • 11011....._ ', fr•-1,,,,- *el • Yi ) r i•- , */4,-, ' - `,.. ..\,0, ii Hiky4'4-, , r,:z-)-•-\_./±'.I . `. - -- -- J • if ) hull fin g 14 •,--- --1 ' ,,, --, /A - \ , ,/ ,.N ' '!'_. .,i, a r.', :.- ) X w ,• --.- ,../ .6i-t 'a ,-- • il i i ' • '''''s \ ,••• N . .• k- ,-. . 111,2 V, , 4/V 'alth 460.01V16'''''. : - 4 I kV-kit .11 7•4 V /V ( 7:":" , 1 gp *.'.., , _ \- iss-,-, Ai( 7',. 14trlinin Are'r ''%\ . , "'a 'I ,-,A / •• -- . , ._„- I •: -tw• iatiiii, ace`i.,, .,,..44.,-,,ipi...._ .1 , if..-1,--. -- ..- , 71-141, ( I; -'. • L 4 . ,:. ---; , „... • 1 i st,,,,j! i II -r s r•-••,-;._, .I•••, , . i #.44.11 -1.P-,i 'A 1-'7 ' \ Si, A, .,_40..\:.`-'if.: : r i/0 4,1,„ , '',111, , , ,r-• - fdvc, ..r..: ,:ji/ 1,. , r,....-,', '• ••• -,*• i. k',,/,:rit.., \ • Li___A‘?'11''''''. I OF , , --,.‘ ,.• ., k , lir . . j 0,Itc.) eti......,,,"....,. \t.. .. , . •\• , \---\.___:.%' 6,71 ad"r , , 5.7 s- s., I . jiiiii. tei7"'".-4'.•••".'1Y •.03 V Wit(• 1/{;.-- ‘,- - ,if k•ril \• , at,'// ,) • 1 41."4 rdi 16 '-•. \ 1.L. 4. ' •,,* la • v, • ,4ir, _.,, N ' -_, 44 4 omk..N_\\.1 • o ( v ..--_-,,,, Nit, .. , ,-,..-_ - 4., , - ,,,-„ •., -4,___ Ir r . .. ,,,.... ,, ,/ , . , L ,•\- ,...„4,..4 aely,Tas,acat j.,:it 7,,t ri k;•:,• 0.7) ,r., (,. <-/ „T.I:117:. -1\ -''DE-I --'\.? , /_ _. ..",,JiTiZr 4V s9.fre-*":• : _ . • 1 ') ' T-',' - '\ 801 Corporate Center Drive, ..) 0 ARCAD1S Suite 300 Raleigh,NC 27607 919-854-1282 G&M of North Carolina, Inc. QUADRANGLE LOCATION REV. DRAWING DATE: ACAD FILE: 1/29/16 SCALE , — N SITE LOCATION 0 2000 4000 IIIIIMIN CLIENT: BRENNTAG MID-SOUTH, INC. PM: JS LOCATION: FORMER SOUTHCHEM FACILITY PE/RG: SOURCE:TOPOGRAPHY TAKEN FROM USGS 7.5 MINUTE QUADRANGLE DURHAM, NORTH CAROLINA SOUTHEAST DURHAM AND SOUTHWEST DURHAM DESIGNED: DETAILED: PROJECT NO: FIGURE: DT NC000368.0025 1 1