Dear Mr. Roper:
NORTH CAROLINA
En fr nmerttoi Qualify
February 16, 2021
Subj ect: Compliance Evaluation Inspection
Duke Energy Allen Steam Station
NPDES Permit No. NC0004979
Gaston County
Enclosed is a copy of the Compliance Evaluation Inspection for the inspection conducted at the subject
facility on February 8, 2021, by Ori Tuvia. Michael Gantt's cooperation during the site visit was much
appreciated. Please advise the staff involved with this NPDES Permit by forwarding a copy of the enclosed repot.
The report should be self-explanatory; however, should you have any questions concerning this report,
please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuvia@ncdenr.gov.
Sincerely,
—DocuSigned by:
—A14CC681AF27425...
W. Corey Basinger
Regional Supervisor
Mooresville Regional Office
Division of Water Resources
Attachment: CEI report
Cc: MRO Files (Laserfiche) , Michael Gantt (E-copy)
State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704 663 1699
United States Environmental Protection Agency
E PA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection
1 u 2 1s 1 3 I NC0004979 111 121 21/02/08 117
Type
18 [ i
I I I I I
Inspector Fac Type
19 i G I 201
211111 I I I I I I II I I I I I I I I I I I I I I I I I
I II
I I I I I 166
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
6711.0 I 7° I4 I 71 IN I 72 I N I 73I I 174
L� 1 751
180
1 11111
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES permit Number)
Plant Allen Steam Station
253 Plant Allen Rd
Belmont NC 28012
Entry Time/Date
09:OOAM 21/02/08
Permit Effective Date
20/03/01
Exit Time/Date
10:35AM 21/02/08
Permit Expiration Date
23/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Michael R Gantt/ORC/704-829-2587/
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Allen Stowe,526 S Chruch St Charlotte NC 282011002//704-382-4309/7043829840
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling Dispos Facility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and
Ori A Tuvia
Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers
Date
2/16/2021
,-DocuSigned by:
DWR/MRO WQ/704-663-1699/
RRO 7A7rlF(1174QP
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger DWR/Division of Water Quality/704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
,—DocuSigned by:
2/16/2021
`—A14CC681AF27425...
Page# 1
31
NPDES yr/mo/day
NC0004979 111 121 21/02/08
117
Inspection Type
18 [j
(Cont.)
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
The new permit has the following new areas:
In anticipation of decreased use, Outfall 002 (the ash pond) has two (2) separate effluent limitations
pages; one under normal/decanting stage and one for dewatering.
New outfall 006 — the new outfall will receive all the effluent from the active coal pond, the coal pile coal
yard sump, powerhouse sumps, WFGD, and WWT effluent. The discharge prior to reaching the
effluent pipe will pass through a splitter box that could divert flow to either/both primary basins, each
with 1.5 MGAL capacity. The effluent from both primary retention basins will than combine in a
secondary retention basin with a 12.3 Mgal capacity, and finally an effluent retention structure (where
final pH adjustments can be made). New Outfall 007 — New outfall is the emergency spillway of the
new retention basin (listed under outfall 006) Four new toe drain discharges — 103, 104, 108 and 108 B
Submerged Flight Conveyor (SFC) system was put into service to handle the station's bottom ash in a
dry manner. The system was necessary due to the fact that all station inputs to the ash basin will no
longer be decanting/dewatering operations. Prior to the SFC system being put into service, bottom ash
was sluiced to the ash basin via a system of pumps and piping. The SFC system is an ash handling
system. The water in the system is reused and recirculated in a closed loop system. pH is monitored
and adjusted using soda ash to maintain the system water pH to minimize corrosion to the piping and
components. The bottom ash is collected at the ash hopper of the boiler and transported via piping and
pumps to the SFC. Once the bottom ash and water reaches the SFC, the bottom ash collects in the
lower portion of the tank and the conveyor removes the bottom ash and deposits it to the storage area.
Once the bottom ash is in the storage are, it can then be loaded into trucks and transported to the
station landfill.
Page# 2
Permit: NC0004979
Inspection Date: 02/08/2021
Owner - Facility: Plant Allen Steam Station
Inspection Type: Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Comment: The subject permit will expire on 7/31/2023.
See Summary
Record Keeping
Are records kept and maintained as required by the permit?
Is all required information readily available, complete and current?
Are all records maintained for 3 years (lab. reg. required 5 years)?
Are analytical results consistent with data reported on DMRs?
Is the chain -of -custody complete?
Dates, times and location of sampling
Name of individual performing the sampling
Results of analysis and calibration
Dates of analysis
Name of person performing analyses
Transported COCs
Are DMRs complete: do they include all permit parameters?
Has the facility submitted its annual compliance report to users and DWQ?
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc
on each shift?
Is the ORC visitation log available and current?
Is the ORC certified at grade equal to or higher than the facility classification?
Is the backup operator certified at one grade less or greater than the facility classification'
Is a copy of the current NPDES permit available on site?
Facility has copy of previous year's Annual Report on file for review?
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
❑ • ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
• ❑ ❑ ❑
• ❑ ❑ ❑
•
•
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
Comment: Inspection conducted durinq Covid-19 restrictions. A full file review was not conducted.
Requested lab results and COCs for the month of October 2020. These were sent via email
in a timely manner and were complete.
Laboratory Yes No NA NE
Page# 3
Permit: NC0004979
Inspection Date: 02/08/2021
Owner - Facility: Plant Allen Steam Station
Inspection Type: Compliance Evaluation
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
❑ ❑ • ❑
Comment: The facility is certified to perform on -site field analyses (pH and temperature) under
laboratory certification #5134. The remaining permit -required effluent analyses are
performed by Duke Energy's Environmental Services Laboratory (Certification #248) and the
contracted services of Prism Labs (low level mercury), Shealy Labs, Pace Labs, and ETS,
Inc. (toxicity)
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Comment: The subject permit requires effluent grab samples.
Upstream / Downstream Sampling
Is the facility sampling performed as required by the permit (frequency, sampling type, anc
sampling location)?
Comment:
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Yes No NA NE
❑ ❑ • ❑
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ • ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
Page# 4
Permit: NC0004979
Inspection Date: 02/08/2021
Owner - Facility: Plant Allen Steam Station
Inspection Type: Compliance Evaluation
Operations & Maintenance Yes No NA NE
Comment: The facility was not generating electricity at the time of the inspection. The FGD WWTS is
connected to a computer monitoring system to assist the on -site staff in the operation of the
treatment units/processes. since the previous inspection a Submerged Flight Conveyor
(SFC) system was put into service and handles the station's bottom ash in a dry manner.
The system will replace the decanting/dewatering operations from the ash basin. (see
summary for more details)
Equalization Basins
Is the basin aerated?
Is the basin free of bypass lines or structures to the natural environment?
Is the basin free of excessive grease?
Are all pumps present?
Are all pumps operable?
Are float controls operable?
Are audible and visual alarms operable?
# Is basin size/volume adequate?
Comment:
Secondary Clarifier
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Comment:
Chemical Feed
Is containment adequate?
Is storage adequate?
Yes No NA NE
❑ ❑ • ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ • ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 5
Permit: NC0004979
Inspection Date: 02/08/2021
Owner - Facility: Plant Allen Steam Station
Inspection Type: Compliance Evaluation
Chemical Feed
Are backup pumps available?
Is the site free of excessive leaking?
Comment: Static mixers are used.
Flow Measurement - Influent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Comment: The FGD WWTS effluent is measured by an in -line flow meter
Flow Measurement - Effluent
# Is flow meter used for reporting?
Is flow meter calibrated annually?
Is the flow meter operational?
(If units are separated) Does the chart recorder match the flow meter?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ • ❑
Yes No NA NE
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
❑ ❑ • ❑
Comment: Flow measurements for Outfalls 001, 003, and 004 are based on pump curves/logs. Outfall
002 and 006 discharges are measured by a staff guage/ultrasonic level indicator and weir.
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
❑ ❑ ❑ •
❑ ❑ ❑ •
❑ ❑ ❑ •
• ❑ ❑ ❑
Comment: The FGD WWTS is equipped with three operational filter presses.The gypsum material from
the FGD system is stored.
Bottom ash from the SFC collects in the lower portion of the tank and the conveyor removes
the bottom ash and deposits it to the storage area. Once the bottom ash is in the storage
are, it can then be loaded into trucks and transported to the station landfill.
Effluent Pipe
Is right of way to the outfall properly maintained?
•
Yes No NA NE
❑ ❑ ❑
Page# 6
Permit: NC0004979
Inspection Date: 02/08/2021
Owner - Facility: Plant Allen Steam Station
Inspection Type: Compliance Evaluation
Effluent Pipe
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Yes No NA NE
• ❑ ❑ ❑
❑ ❑ • ❑
Comment: The effluent from Outfall 006 appered clear with no floatable solids or foam.
Page# 7