Loading...
HomeMy WebLinkAboutWI0600228_Permit (Issuance)_20210219RECEIVED FEB 0 5 2021 1&ina Department of Environmental Quality — Division of Water Resources F'!R7'mtJn'R+�. NOTIFICATION OF INTENT (NOI) TO CONSTRUCT OR OPERATE INJECTION WELLS The following are "permitted by rule" and do not require an individual permit when constructed in accordance with the rules of I5A NCAC 02C .0200. This forma shall be submitted at least 2 WEEKS prior to iniectiion. AQUIFER TEST WELLS (isit NCAC 02C 0220) These wells are used to inject uncontaminated fluid into an aquifer to determine aquifer hydraulic characteristics. IN SITU REMEDIATION [15A NCAC 02C .122Sl or TRACER WELLS (I5A NCAC 02C. 0229): 1) Passive Injection Systems - In -well delivery systems to diffuse injectants into the subsurface. Examples include ORC socks, iSOC systems, and other gas infusion methods. 2) Small -Scale Injection Operations — Injection wells located within a land surface area not to exceed 10,000 square feet for the purpose of soil or groundwater remediation or tracer tests. An individual permit shall be required for test or treatment areas exceeding 10,000 square feet. 3) Pilot Tests - Preliminary studies conducted for the purpose of evaluating the technical feasibility of a remediation strategy in order to develop a full scale remediation plan for future implementation, and where the surface area of the injection zone wells are located within an area that does not exceed five percent of the land surface above the known extent of groundwater contamination. An individual permit shall be required to conduct more than one pilot test on any separate groundwater contaminant plume. 4) Air Injection Was - Used to inject ambient air to enhance in -situ treatment of soil or groundwater. Print Clearly or Type Information. Illegible Submittals Will Be Returned As Incomplete. DATE: 1-18 20 21 PERMIT NO. W I0600228 (to be filled in by DWR) A. WELL TYPE TO BE CONSTRUCTED OR OPERATED (1) Air Injection Well..: , ,,,,...:..<;..,;.;..,,,..... ....Complete sections B through F, K, N (2) Aquifer Test Well.;. ,.,,. e., .Complete sections B through F, K, N (3) X Passive Injection System..... .Complete sections B through F, H-N (4) Small -Scale Injection Operation.......... ; ......... Complete sections B through N (5) Pilot Test Complete sections B through N (6) Tracer Injection Well ............... ....... .:... Complete sections B through N B. STATUS OF WELL OWNER: Business/Organization C. WELL OWNER(S) — State name of Business/Agency, and Name and Title of person delegated authority to sign on behalf of the business or agency: Name(s): SECU RE Southeast : Attn: Michael Canadv Mailing Address: 651 Executive Place City: Fayetteville State: NC Zip Code: 28305 County: Moore Day Tele No.: (910) 483-6124 Cell No.: .: (910) 483-6124 EMAIL Address: Michael.canady@ncsecu.orj _ Fax No.: Deemed Permitted GW Remediation NO! Rev. 3-1-2016 Page 1 D. PROPERTY OWNER(S) (if different than well owner) Name and Title: same Company Name Mailing Address: City: Raeford State: NC Zip Code: County Day Tele No.: Cell No.: EMAIL Address; Fax No.: E. PROJECT CONTACT (Typically Environmental Engineering Finn) Name -and .Title: Thomas W. Witner. P.G. Environmental Group Leader.. Company Name Shield Engineering, Inc,,._ Mailing Address: 4301 Taggart Creek Road City: Charlotte State: NC Zip Code:.28208 County: Mecklenburg Day Tele No.: (704) 394-6913 Cell No.: (704) 576-5889 EMAIL Address: twitnerAshieldengineering.com Fax No.: F. PHYSICAL LOCATION OF WELL SITE (1) Facility Name & Address: 4994 Philippi Church Road City: Raeford: County: Hoke Zip Code: 28376 (2) Geographic Coordinates: Latitude**: " or 34 °.9700- :N Longitude**: ° " or 79 °.0985 S Reference Date: Accuracy: Method of Collection: Google Earth **FOR AIR INJECTION AND AQUIFER TEST WELLS ONLY: A FACILITY SITE MAP WITH PROPERTY BOUNDARIES MAY BE SUBMITTED IN LIEU OF GEOGRAPHIC COORDINATES. G. TREATMENT AREA Land surface area of contaminant plume: square feet Land surface area of inj. well network: square feet (< 10,000 ft2 for small-scale injections) Percent of contaminant plume area to be treated: (must be < 5% of plume for pilot test injections) H. INJECTION ZONE MAPS — Attach the following to the notification. (Figures 1, 2, and 3) Contaminant plume map(s) with isoconcentration lines that show the horizontal extent of the contaminant plume in soil and groundwater, existing and proposed monitoring wells, and existing and proposed injection wells; and Cross-section(s) to the known or projected depth of contamination that show the horizontal and vertical extent of the contaminant plume in soil and groundwater, changes in lithology, existing and proposed monitoring wells, and existing and proposed injection wells. Potentiometric surface map(s) indicating the rate and direction of groundwater movement, plus existing and proposed wells. Deemed Permitted GW Remediation NOI Rev. 3-1-2016 Page 2 I. DESCRIPTION OF PROPOSED INJECTION ACTIVITIES — Provide a brief narrative regarding the purpose, scope, and goals of the proposed injection activity. This should include the rate, volume, and duration of injection over time. A release -of approximately 110 gallons of home _heating, oil from :i damaged suPp v line froth an exterior ho nie> heating oil aboveground storage tank located on the property has impacted subsurfacegroundwater above the 15A NCAC 2L .0202:groundwater _quality standards, The use of OSOXTM (Calcium peroxide or equivalent). in MW-1 is planned to enhance the degradation of petroleum contaminant levels in the groundwater. J. APPROVED INJECTANTS — Provide a MSDS for each injectant. Attach additional sheets if necessary. NOTE: Only injectants approved by the NC Division of Public Health, Department of Health and Human Services can be injected Approved injectants can be found online at:"httpf/deg:ne:gov/about/divisions/water- resourcesfwaterresources-permit/wastewater-branehlgroundywater rotection//round-water-approved4n[ectants.. All other substances must be reviewed by the DHHS prior to use. Contact the UIC Program for more info (919-807-6496). Injectant:. Calcium Peroxide .in solid .fprrn .by sock of chemical in.monitor wells, for oxygen Volume of injectant: Varies, by diffusion. .1.74...lb:EHC-OTM or. 0.261.lb-.Oxygen . per well ..-.....:. Concentration at point of injection: 10-40 mg/1.. Percent if in a mixture with other injectants: Calcium peroxide 45 70%, Calcium I3v ll'oxide .`10 20%n, Sodium, Calcium Aluminosilicate.. Hydrated 20-30% Injectant: Volume of injectant:: Concentration at point of injection: Percent if in a mixture with other injectants: Injectant: Volume of injectant: Concentration at point of injection: Percent if in a mixture with other injectants: K. WELL CONSTRUCTION DATA (1) Number of injection wells: Proposed 1 Existing (provide GW-1s) (A (2) For Proposed wells or Existing wells not having GW-1 s, provide well construction details for each injection well in a diagram or table format. A single diagram or line in a table can be used for multiple wells with the same construction details. Well construction details shall include the following (indicate if construction is proposed or as -built): (a) Well type as permanent, Geoprobe/DPT, or subsurface distribution infiltration gallery (b) Depth below land surface of casing, each grout type and depth, screen, and sand pack (c) Well contractor name and certification number Deemed Permitted GW Remediation NOI Rev. 3-1-2016 Page 3 Well MW-1 Date Installed 2/8/2008 Grout Type (ft-bls) Permanent Monitoring Well 0-1ft Portland Bentonite Screen (ft-bls) 5-15ft Casing - Length (ft-bls) 2in PVC 0-5ft Well Contractor Geologic Exploration, INC. Cert. # 28625 L. SCHEDULES — Briefly describe the schedule for well construction and injection activities. Passive oxygen releasing 0S0XsTM will be placed into the existing well MW-1 following receipt of the notification permit .number from NCDEO to prornote efforts: in elevating D0: levels. M. MONITORING PLAN — Describe below or in separate attachment a monitoring plan to be used to determine if violations of groundwater quality standards specified in Subchapter 02L result from the injection activity. The injection of oxygen is not expected to result in violations of the 2L Standards. The monitor wells will be. .samgied on.a regular basis:.. N. SIGNATURE OF APPLICANT AND PROPERTY OWNER APPLICANT: "I hereby certify, under penalty of law, that I am familiar with the information submitted in this document and all attachments thereto and that, based on my inquiry of those individuals immediately responsible for obtaining said information, I believe that the information is true, accurate and complete. I am aware that there are significant penalties, including the possibility of fines and imprisonment, for submitting false information. I agree to construct, operate, maintain, repair, and if applicable, abandon the injection well and all related ar urIerzances in, ance with the 1 SA MCA' 02C 0200 Rules." 't!P So.rf'l,2es. C6-w44E /h. �� SEC w- Signature of Appli t Print or Type Fidi Name and Title Pl OPERTY OWNER (if the propel is hammed by the permit trppldarft) ; "As owner of the property on which the injection well(s) are to be constructed and operated, I hereby consent to allow the applicant to construct each injection well as outlined in this application and agree that it shall be the responsibility of the applicant to ensure that the injection well(s) conform to the Well Construction Standards (ISA NCAC 02C .0200)." "Owner" means any person who holds the fee or other property rights in the well being constructed. A well is real property and its construction on land shall be deemed to vest ownership in the land owner, in the absence of contrary agreement in writing. Signature* of Property Owner (if different from applicant) Print or Type Full Name and Title *An access agreement between the applicant and property owner may be submitted in lieu ofa signature on this form. RECEIVED FEB 0 5 2021 NC DEQ/DWR Central Office Submit the completed notification package to: DWR — UIC Program 1636 Mail Service Center Raleigh, NC 27699-1636 Telephone: (919) 807-6464 Deemed Permitted GW Remediation NOI Rev. 3-1-2016 Page 4 z 0 1 a / Z O 4L 7• o Oo CZ wu W t RECEIVED aFEB 0 5 2021 / MW-5 (NS) WATER SUPPLY WELL (ABANDONED) MW-4 — (NS) MW-1 (23:3) MW-3® (t4S) Si• MW-6, (Ns) ATER ETER x—� HEATING \013 OIL AST rt MW-Z4 (NS) LEGEND • MONITORING WELL TEMPORARY MONITORING WELL WATER SUPPLY WELL - ABANDONED us&L MICROGRAMS PER LITER 23.3 RED VALUE EXCEEDS NCDEQ NCAC 2L STANDARDS (NS) NOT SAMPLED NAPHTHALENE ISOCONCENTRATION. (ug/L) NOTE: 1. GROUNDWATER SAMPLES COLLECTED ON 09/03/2020. 2. ALL LOCATIONS ARE APPROXIMATE. 3. MW-1 TO BE USED AS INJECTION WELL. GRAPHIC SCALE SCALE: Yin. = 20 R. SHIE ENGINEERING, INC. (*MK ROAD akr:ngraienv com CONTAMINANT OF CONCERN CONCENTRATION MAP - GROUNDWATER: KRIS KELTON RESIDENCE 4994 PHILIPPI CHURCH ROAD RAEFORD, NORTH CAROLINA 'SHIESILD11 40728S0 DATE : ___ 11/13/20 DRAWN BY : KJC SCALE : AS SHOWN FIGURE : 1 NC DEQ/DWR Central Office 0 z 0 J W m 3 0 A MW-6 GROUND SURFACE MW-3 MW-1 • —•TD 15' TAN# BROWN FINE TO MEDDIUM:SAND • GRAY, ORANGE, TAN CLAYEY SAND TAN, ORANGE FINE TO MEDIUM SAND WATER SUPPLY WEIL (ABANDONED) A -A' PROFILE LOCATION 14 ETER GRAPHIC SCALE 10 10' 30 40 SCALE: 1 In. > 40 It. TD 15' • TD 15' LEGEND___ . STATIC WATER LEVEL (9.3-20) MW-1 MONITORING WELL LOCATION SCREENED INTERVAL EXTENT OF NAPHTHALENE PLUME NOTE: 1. MONITORING WELL MW-1 IS PROPOSED INJECTION WELL. 10' 10' SCALE A' gilt SHIELD N4 CREEK ENGINEERING, INC., �w.n roQao, G,wum CROSS SECTION A -A' KRIS KELTON RESIDENCE 4994 PHILIPPI CHURCH ROAD RAEFORD, NORTH CAROLINA SHIELD # 4072B50 DATE : 12/01/20 DRAWN BY : KJC r SCALE : AS SHOWN FIGURE : 2 GROUNDWATER MW-5 • (95.24) WATER SUPPLY WELL (ABANDONED) MW-6 (93.21) MW-4 (97.46) W3"�• (94.97) 1 ATER ETER / MW-2 (94.56) / x HEATING OIL AST -13 l P� V. N LEGEND (19 MONITORING WELL TEMPORARY MONITORING WELL FENCE WATER SUPPLY WELL - ABANDONED 0 (98.40) (NM) GROUNDWATER ELEVATION (FEET) GROUNDWATER ELEVATION CONTQUF LINE (FEET) GENERAL GROUNDWATER FLOW DIRECTION NOT MEASURED NOTE: 1. INJECTION WELL LOCATIONS MEASURED BY SHIELD PERSONNEL IN THE FIELD. 2. ALL LOCATIONS ARE APPROXIMATE. 3. CONTOUR INTERVAL - 1 FOOT. 4. GROUNDWATER ELEVATIONS MEASURED 09/03/20. GRAPHIC SCALE SCALE: 1 in. = 20 ft. I illitSHIELD1041044013 8CREEK �� ENGINEERING.INC. 704-304•0114e ma "" 0101denottoesin°°^ GROUNDWATER ELEVATION CONTOUR MAP t09/03/20) KRIS KELTON RESIDENCE 4994 PHILIPPI CHURCH ROAD RAEFORD, NORTH CAROLINA SMEW it 4072850 DATE : 09/11/20 DRAWN BY : KJC SCALE : AS SHOWN FIGURE 3