Date of Report: Dec 04, 2020
Manteo Report #: 20M-2070
27959 Report #: 2020-19642
Customer ID: 09020021
Project ID: Pond Ave. Dewatering
Lab ID
20-49993
Test
Sample ID:
Site: Pond Header Pipe
Collect Date/Time Matrix Sampled by
11/17/2020 10:35 AM Water Client
Method Results Date Analyzed
Ammonia Nitrogen
Chloride
Total Phosphorus
Total Nitrogen (Calc)
Total Kjeldahl Nitrogen (TKN)
Nitrate+Nitrite-Nitrogen
Total Nitrogen
EPA 350.1
SM 4500 CI E
SM 4500 P F
EPA 351.2
EPA 353.2
Total Nitrogen
4.0 mg/L
56 mg/L
0.56 mg/L
4.1 mg/L
< 0.02 mg/L
4.1 mg/L
11/25/2020
11/23/2020
12/01/2020
11/30/2020
11/24/2020
12/01/2020
Lab ID
20-49994
Test
Sample ID: M-3614
Site: Pond Header Pipe
Collect Date/Time Matrix Sampled by
11/17/2020 10:35 AM Water Client
Method Results Date Analyzed
Fecal Coliform
Idexx Coldert-18
<1 MPN/100m1 11/17/2020
Comment:
Reviewed by: �•-ied
Report #::2020-19642 Page 1 of 1
Environmental Chemist, Inc., Wilmington, NC Lab #94
Client:
Sample Receipt Checklist
Date: 1 I 1 2-0 Report Number:
6602 Windmill Vb
Wilmington, NC 284
910.392.02
Receipt of sample: ECHEM Pickup 0 Client Delivery 0 IUPSJ FedEx 0 Other 0
❑ YES ❑ NO N/A 1. Were custody seals present on the cooler?
❑ YES I❑ NO N/A 2. If custody seals werepresent,were theyintact unbroken?
intact/unbroken?
temperature upon receipt 2, _, °C Corrected temperature upon receipt °t
How temperature taken: 0 Temperature Blank I Against Bottles
IR Gun ID: Thomas Traceable S/N 192511657
IR Gun Correction Factor °C: 0.0
❑ NO 3. If temperature of cooler exceeded 6°C, was Project Mgr./QA notified?
YES ❑ NO 4. Were proper custody procedures (relinquished/received) followed?
❑ NO 5. Were sample ID's listed on the COC?
YES I❑ NO 16. Were samples ID's listed on sample containers?
YES j❑ NO 17. Were collection date and time listed on the COC?
YES I❑ NO J 8. Were tests to be performed listed on the COC?
YES ❑ NO 9. Did samples arrive in proper containers for each test?
YES I❑ NO I10. Did samples arrive in good condition for each test?
YES I❑ NO I11. Was adequate sample volume available?'
YES I❑ NO j12. Were samples received within proper holding time for requested tests?
YES ❑ NO 13. Were acid preserved samples received at a pH of <2? *
YES 0 NO 14. Were cyanide samples received at a pH >12?
O YES 0 NO 15. Were sulfide samples received at a pH >9?
YES 0 NO 16. Were NH3/TKN/Phenol received at a chlorine residual of <0.5 m/L? **
❑ YES 0 NO 17. Were Sulfide/Cyanide received at a chlorine residual of <0.5 m/L?
❑ YES 0 NO 18. Were orthophosphate samples filtered in the field within 15 minutes?
* TOC/Volatiles are pH checked at time of analysis and recorded on the benchsheet.
** Bacteria samples are checked for Chlorine at time of analysis and recorded on the benchsheet.
Sample Preservation: (Must be completed for any sample(s) incorrectly preserved or with headspace)
Sample(s) were received incorrectly preserved and were adjusted accordingly
by adding (circle one): H2504 HNO3 HCI NaOH
Time of preservation: If more than one preservative is needed, notate in comments below
Note: Notify customer service immediately for incorrectly preserved samples. Obtain a new sample or
notify the state lab if directed to analyzed by the customer. Who was notified, date and time:
Volatiles Sample(s) were received with headspace
COMMENTS:
DOC. QA.002 Rev 1
-
:.'•
.-e
.
co
.-.1
IllY1 ILE - DEUHLORINATION : Samples for Ammonia, TICN, Cyanide., Phenol, end Bacteria must be dechlorinatecl (0.2 ppm or less) in the field at
the time of collection. See reverse side for instructions.
i
)
5
)
g
•
4
.
•
. .
• .
... . .
t .1 • ....
-.-: • 1..
.
• ... . .
, .-: . •
:,. .
, t
,...,
....li•-,,
-, •,---
.. 7•:,
1 z41 '-•.!•'• ''•-Th•••
, i • ' C12' •
. , ..
.....
co
co
= 6.•
5 1-
et
ra E
r,-
..,. i'•
CI
...^
CD
..
=
..2
Co-
•-•
ro
.
•
'S
.0 ))
LQ
5
...C.,
=
LAB ED
NuresFai. 11
•
''.:.....
--ar•
....z
..—.
........,
—
ti
t-7
::::
P-f•
n
E7 u
t)
=
,
.
e,
,z
.,
TEMP
LI,
......
.._
8'
-C.,
-
-
---
TD.
)-3
-
.
Sample
Type
onqL)n-carpc-Inq)ncic“")cmnon4-1(n
Conaposite ci]
or C
Grab 11
Q
,
,...,
„
,..,
,_,
c
,.0
c
,..
c
,v
c
,_
c
,.1
c
,z
c
,...
•cr]
Contaiaer .s.„..
(Par G-)
,.......;,,AAp
3
Received By:
•
.
tn
Chlorine blii
mga, r4
F
_
C.
ii
.
•
..,_,,.„0„..-.
::,. .
. _..
.
• :.
g
rip. •
\`•-
ENTOo
4
.
•
•
...
NaOH
TRIO
0
Date/Time
•
0.1:1012.
J
•
.
.
.._ L)
ik •
.
k.
•
..i
....\
..1:1
C.
"...-
r-4"'"•,,
;
ris
7 roi •
g
. .. tr.
01'4
1'.4 c
E