HomeMy WebLinkAboutNC0031836_Compliance Evaluation Inspection_20210202ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. DANIEL SMITH NORTH CAROLINA
Director Environmental Quality
February 2, 2021
Andy Smith, Operations Manager/Water Resources
City of Statesville
Post Office Box 1111
Statesville, North Carolina 28687
Subject: Compliance Evaluation Inspection
City of Statesville/ 4th Creek WWTP
NPDES Permit No. NC0031836
Iredell County
Dear Mr. Smith:
Enclosed is a copy of the Compliance Evaluation Inspection Report for the inspection conducted at the subject
facility on January 28, 2021, by Mr. Wes Bell of this Office. Please inform the facility's Operator -in -Responsible
Charge (ORC) of our findings by forwarding a copy of the enclosed report.
Should you have any questions concerning this letter, please do not hesitate to contact Mr. Bell at (704) 235-
2192, or via email at wes.bell@ncdenr.gov.
Enclosure:
Inspection Report
D_E
NORTH CAROLINA
Department el EnNrumimbl Qualpy
Sincerely,
p—DocuSigned by:
`—A14CC681 AF27425...
W. Corey Basinger, Regional Supervisor
Water Quality Regional Operations Section
Division of Water Resources, NCDEQ
North Carolina Department of Environmental Quality I Division of Water Resources
Mooresville Regional Office 1610 East Center Avenue, Suite 301 I Mooresville, North Carolina 28115
704.663.1699
United States Environmental Protection Agency
EPA Washington, D.C. 20460
Water Compliance Inspection Report
Form Approved.
OMB No. 2040-0057
Approval expires 8-31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code
1 IN I 2 IL I
21 1 1 1 1 1
NPDES yr/mo/day Inspection
3 I NC0031836 111 121 21/01/28 117
Type
1810I
I I 1 1 1
Inspector Fac Type
191 S I 2011
1 1 1 1 11 1 1 1 I I I 1 1 1 1 1 1 I I I I I
1 11
1 1 1 I 1 P6
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA Reserved
67I2.0 I 70I4 I 71IN I 72 I N I 73I 1 74 751
I I 1
I I I I I I I80
l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
POTW name and NPDES oermit Number)
Fourth Creek WWTP
693 Bell Farm Rd
Statesville NC 28687
Entry Time/Date
09:20AM 21/01/28
Permit Effective Date
19/03/01
Exit Time/Date
02:05PM 21/01/28
Permit Expiration Date
23/03/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s)
///
Brian Mack Dishman//704-875-6443 /
Kenneth Andrew Galloway/ORC//
Other Facility Data
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Ron Smith,PO Box 1111 Statesville NC 286871111/City Manager/704-878-3584/
No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Flow Measurement Operations & Maintenar Records/Reports
Self -Monitoring Progran Sludge Handling DispoFacility Site Review Effluent/Receiving Wate
Laboratory
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
(See attachment summary)
Name(s) and Signature(s)
Wes Bell
of Inspector(s) Agency/Office/Phone and Fax Numbers Date
�Docusigned by: DWR/MRO WQ/704-663-1699 Ext.2192/ 2/2/2021
"-A61696D90CC3437...
Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date
W. Corey Basinger DWR/Division of Water Quality/704-235-2194/
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
DocuSigned by:
2/2/2021
A14CC681AF27425...
Page# 1
NPDES yr/mo/day
31 NC0031836 111 121 21/01/28
I17
Inspection Type
18 [j
1
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Page# 2
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Permit
(If the present permit expires in 6 months or less). Has the permittee submitted a new
application?
Is the facility as described in the permit?
# Are there any special conditions for the permit?
Is access to the plant site restricted to the general public?
Is the inspector granted access to all areas for inspection?
Yes No NA NE
❑ ❑ • ❑
▪ ❑ ❑ ❑
Comment: The City implements a Division -approved Industrial Pretreatment Program.
Gravity belt thickener should be removed from the facility description during the next permit
renewal process.
The last compliance evaluation inspection at this facility was performed by DWR staff on
2/8/2019.
Record Keeping Yes No NA NE
Are records kept and maintained as required by the permit? • ❑ ❑ ❑
Is all required information readily available, complete and current? • ❑ ❑ ❑
Are all records maintained for 3 years (lab. reg. required 5 years)? • ❑ ❑ ❑
Are analytical results consistent with data reported on DMRs? • ❑ ❑ ❑
Is the chain -of -custody complete? • ❑ ❑ ❑
Dates, times and location of sampling •
Name of individual performing the sampling •
Results of analysis and calibration •
Dates of analysis •
Name of person performing analyses •
Transported COCs •
Are DMRs complete: do they include all permit parameters? • ❑ ❑ ❑
Has the facility submitted its annual compliance report to users and DWQ? • ❑ ❑ ❑
(If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operatc • ❑ ❑ ❑
on each shift?
Is the ORC visitation log available and current? • ❑ ❑ ❑
Is the ORC certified at grade equal to or higher than the facility classification? • ❑ ❑ ❑
Is the backup operator certified at one grade less or greater than the facility classification' • ❑ ❑ ❑
Is a copy of the current NPDES permit available on site? • ❑ ❑ ❑
Facility has copy of previous year's Annual Report on file for review? • ❑ ❑ ❑
Page# 3
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Record Keeping Yes No NA NE
Comment: The records reviewed during the inspection were organized and well maintained. Discharge
Monitoring Reports (eDMRs) were reviewed for the period January 2020 through December
2020. All monitoring frequencies were correct. Effluent monthly average flow violations
were reported for February, May and August 2020. These violations have been previously
addressed by the Division through the issuances of Notice of Deficiencies (NODs) and
Notice of Violations (NOVs).
Laboratory
Are field parameters performed by certified personnel or laboratory?
Are all other parameters(excluding field parameters) performed by a certified lab?
# Is the facility using a contract lab?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Incubator (Fecal Coliform) set to 44.5 degrees Celsius+/- 0.2 degrees?
Incubator (BOD) set to 20.0 degrees Celsius +/- 1.0 degrees?
Yes No NA NE
• ❑ ❑ ❑
▪ El El El
• ❑ ❑ ❑
Comment: Influent and effluent analyses are performed under the City of Statesville's municipal
laboratory (4th Creek) certification #181. Pace Analytical Services, Meritech, Inc., StatesvillE
Analytical and ETT Environmental have also been contracted to provide analytical support.
Influent Sampling
# Is composite sampling flow proportional?
Is sample collected above side streams?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is sampling performed according to the permit?
Comment: The subject permit requires influent BOD and TSS composite samples.
Effluent Sampling
Is composite sampling flow proportional?
Is sample collected below all treatment units?
Is proper volume collected?
Is the tubing clean?
# Is proper temperature set for sample storage (kept at less than or equal to 6.0 degrees
Celsius)?
Is the facility sampling performed as required by the permit (frequency, sampling type
representative)?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
▪ ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Page# 4
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Effluent Sampling Yes No NA NE
Comment: The subject permit requires composite and grab effluent samples.
Upstream / Downstream Sampling Yes No NA NE
Is the facility sampling performed as required by the permit (frequency, sampling type, anc ❑ ❑ • ❑
sampling location)?
Comment: The instream monitoring requirements have been conditionally waived due to the City's
participation in the Yadkin -Pee Dee River Basin Association.
Operations & Maintenance
Is the plant generally clean with acceptable housekeeping?
Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable
Solids, pH, DO, Sludge Judge, and other that are applicable?
Yes No NA NE
Comment: The wastewater treatment facility appeared to be properly operated and well maintained.
The ORC and staff incorporate a comprehensive process control program with all
measurements being documented and maintained on -site. In-depth operation and
maintenance records were also being maintained on -site. The facility is equipped with a
SCADA System that is accessible at multiple locations.
Bar Screens Yes No NA NE
Type of bar screen
a.Manual ❑
b.Mechanical •
Are the bars adequately screening debris? • ❑ ❑ ❑
Is the screen free of excessive debris? • ❑ ❑ ❑
Is disposal of screening in compliance? • ❑ ❑ ❑
Is the unit in good condition? • El El ❑
Comment: Both mechanical screens were in service. Screenings are disposed at the County Landfill.
Pump Station - Influent Yes No NA NE
Is the pump wet well free of bypass lines or structures? • ❑ ❑ ❑
Is the wet well free of excessive grease? • El El El
Are all pumps present? • ❑ ❑ ❑
Are all pumps operable? • ❑ ❑ ❑
Are float controls operable? • ❑ ❑ ❑
Is SCADA telemetry available and operational? • El El El
Is audible and visual alarm available and operational? ❑ El • ❑
Page# 5
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Pump Station - Influent
Comment:
Yes No NA NE
Aeration Basins Yes No NA NE
Mode of operation Step feed
Type of aeration system Surface
Is the basin free of dead spots? ■ ❑ ❑ ❑
Are surface aerators and mixers operational? ■ ❑ ❑ ❑
Are the diffusers operational? ❑ ❑ ■ ❑
Is the foam the proper color for the treatment process? ■ ❑ ❑ ❑
Does the foam cover less than 25% of the basin's surface? ■ ❑ ❑ ❑
Is the DO level acceptable? • ❑ El El
Is the DO level acceptable?(1.0 to 3.0 mg/I) • El El El
Comment: Both aeration basin trains (equipped with platform aeration) were in service.
Secondary Clarifier Yes No NA NE
Is the clarifier free of black and odorous wastewater?
Is the site free of excessive buildup of solids in center well of circular clarifier?
Are weirs level?
Is the site free of weir blockage?
Is the site free of evidence of short-circuiting?
Is scum removal adequate?
Is the site free of excessive floating sludge?
Is the drive unit operational?
Is the return rate acceptable (low turbulence)?
Is the overflow clear of excessive solids/pin floc?
Is the sludge blanket level acceptable? (Approximately'/4 of the sidewall depth)
Comment: All three secondary clarifiers were in service.
Pumps-RAS-WAS
Are pumps in place?
Are pumps operational?
Are there adequate spare parts and supplies on site?
Comment:
▪ El El El
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
■ ❑ ❑ ❑
Yes No NA NE
■ ❑ ❑ ❑
Page# 6
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Pumps-RAS-WAS Yes No NA NE
Disinfection -Liquid
Is there adequate reserve supply of disinfectant?
(Sodium Hypochlorite) Is pump feed system operational?
Is bulk storage tank containment area adequate? (free of leaks/open drains)
Is the level of chlorine residual acceptable?
Is the contact chamber free of growth, or sludge buildup?
Is there chlorine residual prior to de -chlorination?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: All three chlorine contact chamber trains were in service. One contact chamber is typically
drained and cleaned every quarter.
De -chlorination Yes No NA NE
Type of system ? Liquid
Is the feed ratio proportional to chlorine amount (1 to 1)? ❑ ❑ • ❑
Is storage appropriate for cylinders? ❑ ❑ • ❑
# Is de -chlorination substance stored away from chlorine containers? • ❑ ❑ ❑
Comment:
Are the tablets the proper size and type?
Are tablet de -chlorinators operational?
Number of tubes in use?
Comment:
Flow Measurement - Effluent Yes No NA NE
# Is flow meter used for reporting? • ❑ ❑ ❑
Is flow meter calibrated annually? • ❑ ❑ ❑
Is the flow meter operational? • ❑ ❑ ❑
(If units are separated) Does the chart recorder match the flow meter? ❑ ❑ • ❑
Comment: The flow meter is calibrated twice per year and was last calibrated on 11/5/2020 by FCX
Services.
The contracted company should perform an instantaneous flow measurement verification
(against standard discharge tables) during the on -site calibration to ensure the meter reads
within 10% of the true discharge volume.
Effluent Pipe
Is right of way to the outfall properly maintained?
Yes No NA NE
Page# 7
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Effluent Pipe
Are the receiving water free of foam other than trace amounts and other debris?
If effluent (diffuser pipes are required) are they operating properly?
Comment: The effluent appeared clear with no floatable solids or foam.
Aerobic Digester
Is the capacity adequate?
Is the mixing adequate?
Is the site free of excessive foaming in the tank?
# Is the odor acceptable?
# Is tankage available for properly waste sludge?
Comment:
Solids Handling Equipment
Is the equipment operational?
Is the chemical feed equipment operational?
Is storage adequate?
Is the site free of high level of solids in filtrate from filter presses or vacuum filters?
Is the site free of sludge buildup on belts and/or rollers of filter press?
Is the site free of excessive moisture in belt filter press sludge cake?
The facility has an approved sludge management plan?
Yes No NA NE
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The belt press was operational; however, the treatment unit was not in service during the
inspection.
Dewatered bio-solids are treated via Sta-Lime process and distributed under Permit No.
WQ0006245. The City also maintains Land Application Permit No. WQ0014543 as backup.
Standby Power
Is automatically activated standby power available?
Is the generator tested by interrupting primary power source?
Is the generator tested under load?
Was generator tested & operational during the inspection?
Do the generator(s) have adequate capacity to operate the entire wastewater site?
Is there an emergency agreement with a fuel vendor for extended run on back-up power?
Is the generator fuel level monitored?
Yes No NA NE
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
• ❑ ❑ ❑
Comment: The backup generator is tested every ten (10) days under load. The generator is serviced
quarterly by Power Generation & Control.
Page# 8
Permit: NC0031836
Inspection Date: 01/28/2021
Owner - Facility: Fourth Creek WWTP
Inspection Type: Compliance Evaluation
Standby Power
Yes No NA NE
Page# 9