HomeMy WebLinkAboutNC0026352__Performance Lab Results_20041122ATA
NCDENR
North Carolina Department of Environment and Natural Resources
Division of Water Quality
Michael F. Easley, Governor William G. Ross, Jr., Secretary
Alan W. Klimek, P.E., Director
November 22, 2004
Mr. Alton Brisson
Bladenboro WWTP
P.O. Box 1407
Bladenboro, NC 28320-
SUBJECT: Performance Evaluation Results
Dear Mr. Brisson:
DENR
NOV 2 3 2004
I1..0
The performance evaluation (PE) results submitted by your laboratory from the NSI Proficiency Testing
Study DMRQA-24B have been received and evaluated. The results detailed below represent the status for
each of your certified parameters and methods to date. A blank in the "PE complete" column indicates no PE
yet recorded for this calendar year. A "Pass" entry indicates your lab has satisfied the annual performance
evaluation requirement for that parameter and/or method. Other information in this column indicates vendor
and Study identification. A "Fail" entry requires a follow up sample to be analyzed and reported to this office
within 60 days. An N/A entry represents parameter exemption from the performance evaluation
requirement. A date entered beside the "Fail" entry represents the completion deadline for this PE follow up.
'Parameter/Method >t r '.,., ` rtv
PEStatus :
Follow
Due'...
RESIDUAL CHLORINE, Std Method 4500 CI G
Fail ERA DMR-QA 24B
1/31/2005
DISSOLVED OXYGEN, Std Method 4500 0 G
N/A
pH, Std Method 4500 H B
Pass ERA DMR-QA 24
TEMPERATURE, Std Method 2550E
N/A
To date the PE requirement has not been satisfied for all of your certified parameters and methods.
You are reminded that an acceptable performance evaluation (PE) result must be obtained for all certified
parameters which are available from the accredited vendors. Failure . to submit a passing PE result by
December 31, 2004. will be considered a first miss. Failure to analyze and submit an acceptable follow up
sample result within 60 days or producing a second successive unacceptable result may result in
decertification for that parameter.
Please contact us at 919-733-3908 if you have questions or need additional information.
Sincerely,
Norman L. Good
Laboratory Section
cc: James W. Meyer
Fayetteville Regional Office
Laboratory Section
1623 Mail Service Center, Raleigh, North Carolina 27699-1623
4405 Reedy Creek Road, Raleigh, North Carolina 27607
Phone: 919-733-3908 / FAX: 919-733-6241 / Internet: www.dwglab.org
An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper
NorthCarolina
Naturally