HomeMy WebLinkAboutNC0026352_Inspection_20010827ilo / AVA 744t NCDENR North Carolina Department of Environment and Natural Resources Michael F. Easley, Governor August 27, 2001 Mr. Delane Jackson Town Administrator Town of Bladenboro .POBox 445 Bladenboro; NC 28320 SUBJECT: Compliance Evaluation Inspection Town of Bladenboro Wastewater Treatment Plant NPDES Permit No. NC0026352 Bladen County William G. Ross Jr., Secretary Gregory J. Thorpe, Ph.D. Acting Director Division of Water Quality Dear Mr. Jackson: Enclosed is a copy of the Compliance Evaluation Inspection conducted August 21, 2001. During the inspection a technical assistance visit was also conducted by Don Register from our office. As part of the inspection a tour of the Wastewater Treatment Plant was conducted. The observations and recommendations from the inspection are in Part D. Summary of Findings/Comments of this inspection report. The cooperation of Mr. Lynn Brisson, Grade IV ORC, Mr. Curlie Locklear, Grade IV Backup Operator and Mr. David McKew, Grade IV Regional Manager was appreciated. As a reminder preservation of the Waters of the State can only be acquired through consistent NPDES permit compliance. Please: review the attached report. If your or your staff have any questions do not hesitate to contact me at (910) 486-1541. Sincerely, (L, J -, Belinda S. Henson Environmental Chemist /bsh Enclosures cc: Mr. Lynn Brisson, ORC, Hydro Management Services Central Files Fayetteville Regional Office FRO Files 225 Green Street - Suite 714, Fayetteville, North Carolina 28301-5043 Phone: 910-486-15411 FAX: 910-486-07071 Internet: www.enr.state.nc.us/ENR An Equal Opportunity 1 Affirmative Action Employer - 50% Recycled 110% Post Consumer Paper NPDES COMPLIANCE INSPECTION REPORT North Carolina Division of Water Quality Fayetteville Regional Office Section A. National Data System Coding Transaction Code: N NPDES NO. NC0026352 Date: 010821 Inspection Type: C Inspector: S Facility Type: 1 Reserved: Facility Evaluation Rating: 3 BI: N QA: N Reserved: Section B: Facility Data Name and Location of Facility Inspected: Town of Bladenboro WWTP Entry Time: 10:00am Permit Effective Date: 010901 Exit Time/Date: 3:30pm/010821 Permit Expiration Date: 040731 Name(s), title(s) of On -Site Representative(s): Lynn Brisson (Certified Grade IV) - "ORC" Curlie Locklear (Certified Grade IV) - "Backup Operator" David McKew (Certified Grade IV) - "Regional Manager" Phone Number(s): (910)863-0102 Name, Title and Address of Responsible Official: Mr. Delane Jackson, Town Administrator PO Box 445 Bladenboro, NC 28320 Contacted: no Section C: Areas Evaluated During Inspection (S = Satisfactory, M = Marginal, U = Unsatisfactory, N = Not Evaluated, N/A = Not Applicable) Records/Reports S Flow:: easurement S ora reatmen onitorin isposa rogran Effluen eceiving Waters: S ompliance Schedule N/.= eration `& Maintenance S- ther:: Mr. Jackson Page 3 August 27, 2001 Section D: Summary of Findings/Comments: 1. The wastewater stream is made up of 100% domestic. The facility continues to be operated by the contract company "Hydro Management Services". Mr. Brisson is the ORCand has been operating this facility since July 17, 2001. Three (3) constant speed influent pumps are used to bring wastewater into the plant. One (l) pump was not operational at the time of the inspection. A recommendation is to repair this pump to insure the availability of ways to pump the wastewater flow into the plant. The manual bar screens"was operational. A recommendation is to install an automatic bar screen since.this facility is not required to be staffed 24 hours a day. The screenings are cleaned from the headworks daily and placed in a container which is disposed of through the county landfill. The two (2) aeration basins contain two (2) aerators in each. The aerators had been turned off to assist the plant with operating under conditions with flows of over .700 MGD due to 3 inches of rain the night before. The facility has Inflow/Infiltration (I/I) into their plant which increases flows during rain events: Inflow/Infiltration problems should be addressed and eliminated to assist with the efficiency of the operation of the wastewater plant. The two (2) secondary clarifiers appeared to have some fine floc flowing over the weirs at the time of the inspection. The polishing clarifier appeared to have a sludge depth of less than (<) 1 foot with a tank depth of thirteen (13) feet. The clarifier does not have a recirculation line so solids are pumped from the clarifier three times/week by submersible pumps and piped to the sludge holding basin. The effluent flows from the polishing clarifier to the aerated polishing pond before chlorine. Historical background does not reveal solid removal from the polishing pond. An evaluation of the solids content should be completed in'the polishing pond. 8 The effluent is disinfected by chlorine and dechlorinated by sulfur dioxide. A recommendation to install a flow paced chlorine system which could reduce NPDES permit limit violations and could also reduce costs in disinfection. 9. The effluent flow meter was calibrated August , 2000 by "Carolina Technical Co. Please be reminded that all records should be retained for three (3) years. It is advisable that the flow meter calibration document contain the % error before and after calibration in the future by the technician. 10. The effluent appeared to be free of solids. 11. The effluent is discharged to.a 2.5 acre wetland area which flows to Bryant Swamp. The effluent is discharged at the end of the pipe and through a few of the distribution openings. Ouroffice has allowed the Town to discharge at the end of the pipe instead of through the openings. Mr. Jackson Page 4 August 27, 2001 12. The effluent composite sampler was operational. The sampler tubing appeared to have some buildup in it. The tubing should be replaced or cleaned immediately to eliminate possible NPDES permit limits. 13. Sludge is treated in a aerated sludge holding basin (thickener) and a aerobic digester. The .17 acre aerated lagoon is used as the aerobic digester presently. The facility has 63.1 acres of land permitted for sludge disposal under permit # WQ0014452. The facility has not disposed of sludge through land application since 1997. A recommendation would be to begin sludge disposal as soon as possible to assist with maintaining treatment process equilibrium and maintaining NPDES permit compliance. 14. The facility has dual sludge drying beds which are not used and have not been used for years. The facility staff discussed possibly removing the beds from the site.. Please submit a request to our office in writing. 15. Backup power is located at the facility to assist with operations when power outages occur. It is manually controlled. 16. The following NPDES permit required parameters are analyzed on site: pH, Temperature, Dissolved Oxygen, and Chlorine Residual. All other required parameters are analyzed by the commercial laboratory "Environment 1" with the exception of. Toxicity which is analyzed by "Similab". 17. Laboratory records were reviewed for the month of June 2001 on the day of the inspection and compared to Discharge Monitoring Reports (DMRs). Records for August and September 2000 were faxed to our office for review. All records reviewed appeared to be adequate. Mr. Brisson communicated during the inspection that he had been operating this facility since July 17, 2001 and he had not had a chance to organize the records. As a requirement all records should be maintained for 3 years and all sludge records maintained for 5 years. 18. A compliance evaluation analysis report for the period July 2000 through June 2001 revealed a Toxicity violation for the month of February 2001. 19. The following Notice of Violations (NOVs) have been sent to the permittee from our office: August 2000 - One (1) Fecal Coliform (weekly) November 2000 -Two (2) Fecal Coliform (weekly) February 2001 - Toxicity March 2001 - Toxicity. Please respond to our office within 30 days of receipt of this report concerning the following items: 2, 3, 4, 7, 8, 12, and 13. Name and Signature of Inspector Belinda S. Henson eeQ Name and Signature of Reviewer Action Taken Agency/Office/Telephone Date DENR/Fayetteville/(9 1 0)4 8 6- 154 1 Agency/Office/Telephone DENR/F ayetteville/(9 1 0)4 8 6- 154 1 Regulatory Office Use Only Compliance Status Noncompliance Compliance 2`1_a i Date Date Section D: Summary of Findings/Comments Brief Facility Description: Continue to operate a 0.5 MGD WWTP consisting of the following treatment units: influent pump station, bar screen. parshall flume, effluent flow recording equipment, dual aeration basins, dual primary clarifiers, aerated sludge holding basin. dual sludge drying beds, 0.17 acre aerated lagoon (used as a sludge digester), 42 ft. diameter final clarifier, 0.36 acre polishing pond. FACILITY SITE REVIEW Ye No N/A 1. Treatment units properly operated and maintained. No N/A 2. Standby power or other equivalent provision provided. Yes N/A 3. Adequate alarm system for power or equipment failure available. Yes No N/A Yes No N/A 4. Sludge disposal procedures appropriate: a. Disposal of sludge according to regulations b. State approval for sludge disposal received. Yes N/A 5. Sufficient sludge disposed of to maintain treatment process equilibrium. Yes No N/A 6. The ORC and Backup Operator are officially designated with NCDENR/DWQ Training and Certification Unit. Yes No N/A 7. Adequate spare parts and supplies inventory maintained. No N/A 8. Plant has general safety structures such as rails around or covers over tanks, pits, or wells. Yes No N/A 9. Plant is generally clean, free from open trash areas. 10. Screening: T) No N/A a. Manual Yes No N/A b. Mechanical Yes (No) N/A c. Buildup of debris Ye No N/A d. Screenings properly disposed of. 11. Yes No Yes No N/A Yes No NIA Grit Removal: a. Excessive organic content in the grit chamber b. Excessive odors c. Grit properly disposed of. Page 2 12. Primary clarifier: Yes No a. Excessive gas bubbles Yes No N/A b. Black and odorous wastewater Yes No N/A c. Poor suspended solids removed : Yes No N/A d. Excessive buildup of solids in center well of circular clarifier Yes No N/A e. Weirs level Yes No N/A f Weir blockage Yes No N/A g. Evidence of short circuiting Yes No N/A h. Lack of adequate scum removal Yes No N/A i. Excessive floating sludge Yes No N/A j. Broken sludge scraper. Yes No Na Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A Yes No N/A 13. Trickling Filter: a. Trickling filter ponding(indicating clogged media) b. Leak at center column of trickling filter's distribution arms c. Uneven distribution of flow on trickling filter surface d. Uneven or discolored growth e. Excessive sloughing of growth f Odor g. Clogging of trickling filter's distribution ann orifices h. Filter flies, worms, or snails. 14. Activated Sludge Basins/Oxidation Ditches: Yes o * N/A a. Dead spots Yes -N/A b. Failure of surface aerators Yes V N/A c. Air rising in clumps Yes sCa N/A d. Dark foam or bad color . Yes (g N/A e. Thick billows of white, sudsy foam Yes No N/A f. Air rising unevenly ' Yes No N/` g. Excessive air leaks in compressed air piping. 15. Stabilization Ponds/Lagoons: Yes No N% a: Excessive weeds including duckweed in stabilization ponds Yes No b. Dead fish or aquatic organisms Yes No N/A c. Buildup of solids around influent pipe Yes No N/A d. Excessive scum on surface. Page 3 16. Secondary Clarifier: Yes' N/A a. Excessive gas bubbles on surface Yes N/A b. Level overflow weirs Yes N/A c. Weir blockage Yes N/A d. Evidence of short circuiting Yes (0 N/A e. Excessive buildup of solids in center well of circular clarifier e7 No N/A f. Pin floc in overflow j, No N/A g. Effective scum rake Yes J) N/A h. Floating sludge on surface Yes Tot N/A i. Excessive high sludge blanket Yes 1 N/A j. Clogged sludge withdrawal ports on secondary clarifier. 17. Filtration: Yes No /A a. Filter surface clogging Yes No N/A b. Short filter run Yes No N/A c. Gravel displacement of filter media Yes No N/A d. Loss of filter media during backwashing Yes No N/A e. Recycled filter backwash water in excess of 5 percent Yes No N/A f. Formation of mudballs in filter media. Yes No N/A Yes ' N/A Yes N/A (fa) No N/A Yes No N/A Os; No N/A Ye No N/A Qs No N/A Yes No N/A� 18. Chlorination Unit: a. Sludge buildup in contact chamber b. Gas bubbles c. Floating scum and/or solids d. Adequate ventilation of chlorine feeding room and storage area e. NIOSH-approved 30 minute air pack f. All standing chlorine cylinders chained in place g. All personnel trained in the use of chlorine h. Proper chlorine feed, storage, and reserve supply. 19. Ultraviolet radiation disinfection present and in use. 20. Dechlorination: No N/A a: Proper storage of sulfur dioxide cylinders No N/A b. Adequate ventilation of sulfur dioxide feeding room Yes No N/A c. Automatic sulfur dioxide feed or feedback control operating properly. Yes No N/A Yes 0' N/A Yes N/A Yes No 404 21. Aerobic Digester: a. Excessive foaming in tank b. Noxious odor c. Mechanical aeration failure d. Clogging of diffusers. Page 4 Yes No (N/A) Yes No N/A 22. Anaerobic Digester: a. Floating cover tilting b. Gas burner operative 23. Sludge Drying. and/or disposal: Yes No N/A) a. Poor sludge distribution on drying beds No N/A b. Vegetation in drying beds WS ,nc r usefi; ;•210, Yes Oo N/A c. Dry sludge remaining in drying beds Yes cLQ9 N/A d. Dry sludge stored on site No N/A e. Filtrate from sludge drying beds returned to front of plant Yes 5l N/A f. Sludge disposal through county landfill. Yes No N/A g. Sludge land applied. FlQue ref 01; `t- fia ictoof a t°p l `( 24. Filter Press: Yes No 073 a. High level of solids in filtrate from filter presses or vacuum filters Yes No N/A b. Thin filter cake caused by poor dewatering Yes No N/A c. Sludge buildup on belts and/or rollers of filter press Yes No N/A d. Excessive moisture in belt filter press sludge cake. 25. Polishing Ponds or Tanks: Yes N N/A a. Objectionable odor, excessive foam, floating solids, or oil sheens on water surface Yes No N/A b. Solids or scum accumulations in tank or at side of pond Yes o N/A c. Evidence of bypassed polishing ponds or tanks because of low. capacity. 26. Plant Effluent: Yes N/A a. Excessive suspended solids, turbidity, foam, grease, scum, color, and other macroscopic particulate matter present Yes N/A b. Potential toxicity (dead fish, dead plant at discharge) Yes No N/A c. Outfall discharge line easily accessible. • 27. Flow Measurement: 'es No N/A a. Proper placement of flow measurement device No N/A b. Flow meter calibrated Yes (i N/A c. Buildup of solids in flume or weir Yes Td N/A d. Broken or cracked flume or weir Yes No (FILV e. Clogged or broken stilling wells Yes N/A f. Weir plate edge corroded or damaged Yes No N/A g. Flow measurement error less than 10%. Page 5 28. Sampling: CYes='No N/A a. Sampling and analysis completed. on parameters specified by permit Yes No NIA b. Composite sample temperatures maintained at 4 degrees Celsius or less (but above freezing) during sampling es' No N/A c. Contract laboratory used for sample analysis Yes N/A d. Effluent composite samples obtained are flow proportional. RECORDREEPING AND REPORTING es No N/A 1. Records and reports maintained as required by permit. ry No N/A 2. All required information available, complete, and current. es t No N/A 3. Records maintained for 3 years and all sludge records maintained for 5 years. No N/A 4. Analytical results consistent with data reported on DMRs. 5. Sampling and analyses data adequate and include: (es) No N/A a. Dates, times, and location of sampling es'" No N/A b. Name of individual performing sampling es`? No N/A c. Results of analyses and calibration a No N/A d. Dates of analyses (Yes' No N/A e. Name of person performing analyses. Gg No N/A T. es No N/A (Yes; No N/A 6. Monitoring records adequate and include: a. Monitoring charts kept for 3 years b. Flowmeter calibration records kept for 3 years. 7. The pH meter is calibrated daily with two buffers and checked with a third bufferand properly documented. • Yes No N/A 8. Expiration dates of pH buffers adequate. Yes No N/A 9. All thermometers used in NPDES permit reporting is calibrated annually with an NIST certified thermometer or a traceable thermometer annually and documented. gl No N/A 10. The following NPDES permit required parameters are analyzed on site: pH, Temperature, Dissolved Oxygen and Chlorine Residual. Page 6 (e) No N/A 11. The NPDES permit required parameter Total Chlorine Residual is analyzed by approved method. Yes No N! 12. BOD incubator temperature maintained at 20 +/- 1 Degrees Celsius and the temperature maintained in a log for every day of operation. Yes No NIA 13 Fecal coliform incubator maintained at 44.5 +/- 0.2 Degree Celsius and the temperature maintained in a log for every day of operation. Yes No N/A Yes No N/A es No N/A Yes No N/A 14. Plant records adequate and include: a. O & M Manual b. "As -built" engineering drawings c. Schedules and dates of equipment maintenance repairs d. Equipment data cards. Yes No N/ 15. Permittee is meeting compliance schedule. No N/A 16. DMRs complete and include all NPDES permit required parameters. Yes No N/ 17.. The facility has a permitted flow greater than 5 MGD and is required to operateseven days per week 24 hours a day. rest No N/A 18. ORC visitation logs available and current. Yes) No N/A 19. ORC certified at a level equal to or greater than the classification of the wastewater facility. YNo N/A 20. Backup Operator certified at one level less than the classification of the wastewater facility or greater. Yes;) No N/A 21. Current copy of the complete NPDES permit on site. No N/A 22. Facility description verified as contained in NPDES permit. Yes ,No N/A 23. . Facility analyzes process control parameters for example: NILSS, MCRT, Settleable Solids and others that are applicable. Yes No Revised 7/16/01 by Belinda Henson Industrial Waste Surveys (IWS) sent to all possible Significant Industrial Users (SIUs) within the last five years (especially new industries). INSPECTION REPORT UPDATE OPTION: TRX: 5IF KEY: NC0026352INSCEI 010821 SYSMSG: *** DATA ADDED SUCCESSFULLY *** PERMIT--- NC0026352 REG/COUNTY-- 06 BLADEN FACILITY-- BLADENBORO (TOWN) - WWTP LOC-- BLADENBORO .INS TYPE CEI NEXT PLANNED 'INSPECTION INSPECTED BY.: DATE:- 010821 HSB REPORT INSPECTION DMR RESPONSE RECEIVED DATE STATUS STATUS DUE DATE DATE 010827 C C COMMENTS: RESPONSE WITHIN 30 DAYS OF RECEIPT OF REPORT. Town of Bladenboro September 10, 2001 Ms. Belinda S. Henson Environmental Chemist NCDENR, Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, NC 28301-5043 Dear Ms. Henson, ENR-FRO D Vf in As requested, I am writing in response to several items identified in your August 27, 2001 letter regarding the August 21, 2001 inspection and technical assistance visit of the Town of Bladenboro WWTP. I have reviewed the Inspection report and offer the following responses to the items that you requested in Section D of your report. I have numbered the responses consistent with your item numbers. 2. The influent pump station at the WWTP incorporates the use of three (3) pumps. During the inspection, one pump was out of service. Please note; however, that this pump had been repaired and was on -site during the inspection. The pump was returned to service on August 29, 2001. 3. The WWTP utilizes a manual bar screen for removal of influent screenings prior to biological treatment. This unit has been operational and served the facility needs since the current facility constructed. During periods of excessive flow, the manual bar screen requires additional operator attention. This would be a major modification and would require the purchase of the bar screen as well as modification to the flow channel to accept this unit and continue to provide the manual screen for back-up periods. The Town will investigate the cost and feasibility of incorporating a mechanical bar screen into the existing influent structure. 4. The Town will continue to identify and reduce areas of-inflow/infiltration. The Town has recently been awarded a grant to repair its collection system. 7. The WWTP operational staff will conduct a survey of the current solids content in the polishing pond. Sludge depths and core samples will be collected throughout the pond to determine an estimate of sludge accumulation. 8. Information is being collected on the addition of flow paced capabilities to the existing chlorination and dechlorination systems. The Town will evaluate the equipment requirements and cost for future upgrade considerations. 305 South Main Street * Post Office Box 455 * Bladenboro, NC 28320 Phone (910) 863-3655 * Fax (910) 863-3738 12. The inspection recommended the replacement of the effluent composite sampler tubing. The tubing will be replaced and a more aggressive routine replacement schedule adopted by staff to avoid the potential for build up. 13. Provisions are being made to land apply stabilized sludge currently inventoried in the aerated lagoon. I hope this information is helpful in addressing your comments and recommendations. I appreciate the continued assistance from your office. If you have any further questions or require additional information, please advise. Sincerely, Town of Bladenboro dAkt Delane Jacks n Town Adminis rator Cc: Hydro Management Services