Loading...
HomeMy WebLinkAbout20210089 Ver 1_Pre-Filing Meeting Request_20210113ID#* 20210089 Version* 1 Regional Office* Raleigh Regional Office - (919) 791-4200 Reviewer List* Stephanie Goss Pre -Filing Meeting Request submitted 1/13/2021 Contact Name * Contact Email Address* Project Name* Project Owner* Project County* Owner Address: Keven Arrance karrance@hazenandsawyer.com Lake Michie and Little River Raw Water Pump Station Improvements City of Durham Durham Street Address Attn: Lori Montgomery Address Line 2 1600 Mist Lake Drive aty Durham Rbstal / Zip Code 27704 Is this a transportation project? * r Yes r No Type(s) of approval sought from the DWR: W 401 Water Quality Certification - F 401 Water Quality Certification - Regular Express r- Individual Permit F Modification r- Shoreline Stabilization Does this project have an existing project ID#?* r Yes r No Please list all existing project ID's associated with this projects.* RRO #20-238 State / Frovince / Region NC Country USA Do you know the name of the staff member you would like to request a meeting with? Please give a brief project description below.* The project consists of improvements to the City of Durham's raw water pumping stations at Lake Michie and Little River Reservoir. See below for details regarding the proposed work at each pump station. Little River PS The project consists of upgrades to the existing raw water pumping station and raw water intake, as well as construction of a new water service line along the entrance road. The majority of the upgrade work will be performed within the existing infrastructure. Components of the existing gates on the raw water intake, accessible from the operating deck, will be replaced from the exterior with minor adjustments to the drain gate being performed by divers in the lake. Furthermore, spillway roller gate and stop log monorail components, will be replaced from the exterior. Impacts regulated under Section 401 will be restricted to replacement of components of the existing gates by divers. Lake Michie PS The project consists of upgrades to the existing raw water pumping station and raw water intake, installation of a new water service line to the pump station, and installation of a septic system and associated piping and pumping system to connect the pump station's facilities to the septic field. The majority of the upgrades will be fully contained and constructed within the existing infrastructure. Work on the intake will necessitate maintenance dredging in the lake to remove accumulated sediment surrounding the intake. Sediment removal is not expected to extend beyond 200 feet from the intake structure and will be the minimum necessary to allow the intake work to be completed. Following the dredging, a coffer cell will be installed around the intake in order to provide and maintain a dry work area. The intake upgrades consist of providing new bar screens, new multi- level withdrawal capabilities, a low-level intake for emergency use, and a low-level outlet/drain for the lake while maintaining regulated, minimum release volumes. The intake upgrades will increase the capacity of the intake, in preparation for possible future increased demands, but the new pumps installed in this project will not have the capacity to support the increased intake capacity at this time. Please give a couple of dates you are available for a meeting. 1 /19/2021 1 /20/2021 1 /21 /2021 1 /25/2021 1 /26/2021 Please attach the documentation you would like to have the meeting about. 60% Design - Drawings EXCERPT.pdf 1.25MB pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature Submittal Date 1/13/2021 DEPARTMENT OF WATER MANAGEMENT CITY OF DURHAM, NORTH CAROLINA CITY OF DURHAM LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS HAZEN NO.: 31306-001 DECEMBER 2020 b 1. + LAKE MICHIE RAW WATER PUMP STATION LAKE MICHIE DAM RD BAHAMA, NC 27503 00RHN.1 CDUNIT +}- HtA i LITTLE RIVER RAW WATER PUMP STATION 6225 SNOW HILL DR DURHAM NC 27712 LOCATION MAP NOT TO SCALE Hazen HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 NORTH C 60% DESIGN REVIEW - DO NOT USE FOR CONSTRUCTION RALEI LICENSE NO AC038A27607 NC W SEPTIC f LeW NOW OR FORMERLY CITY OF DURHAM IDS 1854 PG 661 BM 129 PG 19B PIN: 0847-03-84-B790 SEE ENLARGED SITE PLAN, C012 LAKE MICHIE EMERGENCY SPILLWAY TBI4 SM1 NW 873939-32 E5060426-72 { FL•ejgAfi NOW OR FORMERLY CITY OF DURHAM LAKE MICHIE R 6737 N 873738.0 E:2030070.64 FI A.A 79 y� - 17•- f TBM-SPK N 8'366215 E-70�9L52.09 EL=386 69 f PUMP �7. ..HOUSE �LErtA FLOOfMLA91 4•Y�x ` SBE NOTE 8 l � 1 of •y • .;• f .� a. • . • ``` NOW OR FORMERLY CITY OF DURHAM IDS 1784 PG 388 BM 128 PG 153 PIN: 0847-03-92-4195 _ WATER ACCESS SEE NOTE 5 EDGE OF WATER •r r �_ NOW OR FORMERLY CITY OF DURHAM OB 129 PG 556 (NOT FOUND) BM 5B PG 171 MI�Jr PIS 57-03-03-6386 Jr `r FEMA 11ACF FUTURE CONDITIONS / SEE NOTE FEMA 1 % ACF SEE NOTE 6 TBµ - SPK N 873349 37 E 29262.99 502§7.C2 _ EL* _- TaNI-SPK ' N 87328187 E:2(6 O4}7 17 LIMITS OF DISTURBANCE, TYP -� •, ' •• • ! PLAN SCALE: 1" = 100' ENTRANCE ROAD b J' \—FEMACROSSSECTIONS,TYP J SEE NOTE 6 7 iT 278.0 NOTES: 1 DATUM INFORMATION: 1.1. HORIZONTAL DATUM: NAD83 1.2. VERTICAL DATUM: NAVD88 2, SURVEYS PERFORMED BY: COOPER AND ASSOCIATES 800 PINNER WEALD WAY, SUITE 201 CARY NC 27513 (919) 469-1760 9/252020 CH ENGINEERING 3220 GLEN ROYAL ROAD RALEIGH, NC 27617 (919) 788-0224 3/102016 - 7/25/2016 COOPER AND ASSOCIATES 800 PINNER WEALD WAY, SUITE 201 _ CARY INC 27513 DURHAM POLICE GUN RANGE (919) 469-1760 4/172015 3 ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE NOTED 4, THE ROCKY AREA NEAR THE TOE OF THE DAM AND SLOPE AREA SOUTHWEST OF THE PUMP HOUSE EXCEED THE TOLERANCE FOR 1' CONTOURS DUE TO THE IRREGULARITY OF THE ROCKS. THE CONTOURS IN THESE AREAS SHOULD BE CONSIDERED APPROXIMATE. 5. ACCESS TO DURHAM POLICE PROPERTY SHALL BE GRANTED FOR LAKE ACCESS FOR INTAKE WORK. EXISTING GRAVEL PATHWAY SHALL BE USED FOR ACCESS AND SHALL BE RESTORED TO EXISTING GRADE UPON COMPLETION OF WORK. 6. FEMA FLOODPLAIN INFORMATION OBTAINED FROM: FLOOD SOURCE: FLAT RIVER MAP NUMBER: 3720OB5700K PANEL EFFECTIVE DATE: 10/19/2016 BFE RANGE (D-S OF DAM): 1 % ACF: 278.0' - 276 2' 1 % ACF FC: 279.0' - 279.2' BFE (U.S OF DAM, NO RANGE (LAKE))): 1 % ACF: 346.6' 1 % ACF FC: 347.2' PROJECT ENGINEER: D- C. HOPKINS 60%DESIGN REVIEW DO NOT USE FOR CONSTRUCTION Hazen HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 DEPARTMENT OF WATER MANAGEMENT CITY OF DURHAM, NORTH CAROLINA _ LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS LAKE MICHIE PUMP STATION CIVIL OVERALL SITE PLAN DATE: DECEMBER 2020 DESIGNED BY: C. WILSON HAZEN NO: 31306-001 DRAWN BY: C. WILSON CONTRACT NO CHECKED BY M. SANTOWASSO DRAWING NUMBER: Colo IF THIS BAR DOES NOT 0 1/2' 1• MEASURE I'THEN DRAWING I� IS NOT TO FULL SCALE REV ISSUED FOR DATE BY o LAKE MICHIE N f ' � II �� PUMP HOUSES NOTES: 1 CONTRACTOR SHALL LAY ANEW GRAVEL ACCESS ROAD UPON COMPLETION OF ALL CONSTRUCTION ACTIVITIES iii� J! ��rjv 2 CONTRACTOR SHALL RESTORE WORK AREAILAYDOWN AREA TO ORIGINAL CONDITION AT COMPLETION OF PROJECT, INCLUDING ANY Kpl�. •� "� Ll GRADING, SEEDING,OR OTHER REPAIRS AS MAY BE NECESSARY, AREA OF NEW SEPTIC FIELD o,�((77 SEE NOTE 3, DWG M010 • , SJ' //%// `�lU� - l1EMA 11 All IC NI ! _ - J • rJ _ El � I (TO O-DEL NEATED) A Y _ 1 SEE NOTE 6, DWG C010._ CONTRACTOR WORK AREA I LAYDOWN AREA /% ` ' ,�• - l�D{.� ■ f� - SEE NOTE 2 i 0 p r � ��_�� �-� .� ..� If •� �4A Q • � EIEO GENERATOR — � R LIMITS OF DISTURBANCE, TYP d `am' • yP RESTORE. GRAVEL ACCESS ROAD ;r •� r � � .� • as - PLAN SCALE: 1" = 30' 1 !!� ♦ `� `�,n S n PROJECT ENGINEER; D. C. HOPKINS onrB: DECEMBER 2020 DEPARTMENT OF WATER MANAGEMENT DESIGNED BY: C. WILSON HazenCITY OF DURHAM, NORTH CAROLINA HAZEN No: 31306-001 LAKE MICHIE PUMP STATION DRAWN BY: C. WILSON 60%DESIGN REVIEW CONTRACT NO: 1 CHECKED BY: M. SANTOWASSO DO NOT USE FOR CONSTRUCTION — LAKE MICHIE AND LITTLE RIVER CIVIL DRAWING HAZEN AND SAWYER SITE PLAN NUMBER: IF THIS BAR DOES NOT 0 1/2' 1• 4011 WESTCHASE BOULEVARD, SUITE 500 RAW WATER PUMP STATION MEASURE V THEN DRAWING RALEIGH. NORTH CAROLINA 27607 IMPROVEMENTS C012 REV ISSUED FOR DATE By IS NOTTO FULL SCALE LICENSE NO.: G-03B1 5 m 1 \r r� .,L n AND DISTRIBUTION BOX, SEE NOTE 3 APPROXIMATE LOCATION OF CONVENTIONAL SEPTIC SYSTEM �FIELD. SEE NOTE 3 _ 1 1 0., vA �1 • ��I r INTAKE f LAKE MICHIE RAW WATER w%l PUMP{NG STATION �a PACKAGED GRN♦DER PUMP STATION 1 6i ELECTRICAL 1 SUBSTATION - APPROXIMATE LS,IQATIO(1 / + OF EXISTING PAC �J / SYSTEM PIPE CORRIDOR, SEE NOTE 1 AND NOTE 6 r. CONCRETE FLAT RIVER CHANNEL r PACKAGED PAL; d FEED SY$TE MS ON CONCRETE PAD ~� SEWER FORGET MAIN SEE NOTE 5--A �Y f , \ III /GRAVEL ROAD Po 1. APPROXIMATE LOCATION OF PROPOSED WELL AND WELL H( 2WELL PIPE SE rNOTES: / 1. EXISTING SURFACE CONDITIONS SHOWN BASED ON �• / f RECENT AND PAST SURVEYS SEE CIVIL DRAWINGS FOR DETAILED SURVEY INFORMATION, UNDERGROUND UTILITIES SHOWN ON THIS SHEET BASED ON CITY OF -� DURHAM, NC CONTRACT II - SECTION 1 BROWN WTP UPGRADE AND EXPANSION POWDER ACTIVATED \ I CARBON FEED SYSTEM DRAWINGS DATED MARCH 2O14 CONTRACTOR SHALL FIELD LOCATE EXISTING PIPING RELATED TO PAC FEED SYSTEM 2 FINAL LOCATION OF WATER WELL PUMP HOUSE SHALL i BE DETERMINED BY WELL SUBCONTRACTOR. 3 FINAL LOCATION OF CONVENTIONAL SEPTIC SYSTEM SHALL BE DETERMINED BY SEPTIC SYSTEM SUBCONTRACTOR. 4 WELL WATER LINE SHALL BE FIELD ROUTED TO AVOID EXISTING OBSTRUCTIONS AND LIMIT DISTURBANCE TO GRAVEL ROAD 5. SANITARY SEWER FORCE MAIN SHALL BE FIELD ' ROUTED FROM PACKAGED SEWER PUMPING SYSTEM TO THE SUBSURFACE CONVENTIONAL SEPTIC SYSTEM SANITARY SEWER PIPE SHALL BE LOCATED MORE THAN 10 FEET HORIZONTAL DISTANCE FROM ALL POTABLE ' WATER AND RAW WATER PIPES. WHERE REQUIRED HORIZONTAL SEPARATION IS NOT POSSIBLE, 18 INCHES MINIMUM VERTICAL SEPARATION SHALL BE PROVIDED BETWEEN THE TOP OF SANITARY SEWER PIPE AND BOTTOM OF ALL OTHER WATER PIPES SEE ADDITIONAL REQUIREMENTS FOR SANITARY SEWER PIPE IN SUBCHAPTER 2T OF TITLE 15A OF THE NORTH •\� CAROLINA ADMINISTRATION CODE" I' 6, EXISTING PAC SYSTEM PIPE CORRIDOR CONSISTS OF TWO 2 1/2' PAC SLURRY, TWO 3" RAW WATER, AND TWO 3/4-COMPRESSED AIR CORRIDOR RUNS APPROXIMATELY 5 FEET OFF OF SIDE OF GRAVEL ROAD, 1 Ny y l 15 0 30' 1-30'L' PROJECT ENGINEER D.C.HOPKNS 60% DESIGN REVIEW DO NOT USE FOR CONSTRUCTION HazenCITY HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0301 DEPARTMENT OF WATER MANAGEMENT OF DURHAM, NORTH CAROLINA LAKE MICHIE SITE WORK MECHANICAL YARD PIPING PLAN DATE DECEMBER2020 DESIGNED BY: H. RICCA HAZEN NO: 31306-001 DRAWN BY K.OVERBY CONTRACT NO: 1 LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS CHECKED BY D. C. HOPKINS DRAWING NUMBER M010 IF THIS BAR DOES NOT 0 u2' 1' MEASURE I"THEN DRAWING ® IS NOT TO FULL SCALE REV ISSUED FOR DATE BY 46" GATE MOTOR OPERATOR 66"x66" GATE MOTOR OPERATOR i 54' BFV MOTOR OPERATOR, TYP 12" VENT GATE MANUAL OPERATOR, TYP 54" BFV MOTOR OPERATOR, TYP 54' BFV MOTOR OPERATOR i INTAK 54" BUTRERFLY VALVE, TVP n n Mcav-0x1+ EL ,733.OD MOV-0221 � AiOV•07t2 { n n TII All: CL 32600 12Sc12" SLUICE GATE, TYP Rik Hsi I 12'x12"SLUICE {ih7E I. n1 -}X'a12' SUJWf: LATE Ilf�' µL EL 3111.* n n N'RW • — 54' RW MOV-6213 - MOV-0223 .CL 3W.00 4 n• r400•os n n MDa•o: 0 n SECTION K 3/16" = V-0" M717 12' VENT GATE MANUAL OPERATOR SECTION L 3116" = 1' 6" M117 PROJECT D. C. HOPKINS ENGINEER: DESIGNEDD. TURNER DRAWN BY:: F)O°Io DESIGN REVIEW BY: J. McCARTHY Liu Nor usE FOR CONSTRUCTION IF THIS BAR DO ES NOT B 112" 1" MEASURE 1'THEN DRAWING IS NOT TO FULL SCALElmmmp J a 7�� HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 DEPARTMENT OF WATER MANAGEMENT CITY OF DURHAM, NORTH CAROLINA LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS LAKE MICHIE RAW WATER PUMP STATION MECHANICAL SECTIONS AT INTAKE DATE: DECEMBER 2020 HAZENNO.: 3I306-001 CONTRACT NO: 1 DRAWING NUMBER: M121 pCHECKED N REV ISSUED FOR DATE By $w o � eo FEMA CROSS SECTIONS, TVP SEE NOTE 4 CH ENGINEERING LOCALIZED COORDINATES REBAR 8 CAP N: 059.5051296' II E:2,036,3236553' I EL=369-31' NEW WATER LINE ALONG SNOW HILL DR SEE DWG CO23 FOR SITE PLAN CPB1N BRNCN CR LAKE DAM FEMA 1%ACE (EXISTING AND FUTURE CONDITIONS) SEE NOTE 4 SEE DWG CO22 FOR ENLARGED PLAN OF SITE WORK AT THE PUMP STATION • INTAKE STRUCTURE ` f1 CARETAKER'S HOUSE f !I ff i f,r I� NOW OR FORMERLY CITY OF DURHAM DB 1076 PG 568 PB 100 PG 130-133 6225 SHOW HILL DR PIN: 0835-01-69-7362 i• i P WATER PUMP STAil011--:, S \` �L CH ENGINEERING NC GRID (NAD83/NSRS2007) REBAR 8 CAP N: 859,484.3695- E:2,038,944-0191' EL=364 53' FEMA 1 %ACE SEE NOTE q FEMA 1 % ACE (FUTURE CONDITIONS) / SEE NOTE 4 to. r 1 NOTES: 1 DATUM INFORMATION: 1.1 HORIZONTAL DATUM: NADB3 1.2 VERTICAL DATUM: NAVD80 2. SURVEY PERFORMED BY: COOPER AND ASSOCIATES 800 PINNER WEALD WAY, SUITE 201 CARY NC 27513 (919)469-1760 9/25/2020 3 ALL DISTANCES ARE HORIZONTAL GROUND DISTANCES UNLESS OTHERWISE NOTED 4- FEMA FLOODPLAIN INFORMATION OBTAINED FROM: FLOOD SOURCE: FLAT RIVER MAP NUMBER: 3720083500K PANEL EFFECTIVE DATE: 10/19/2018 BEE RANGE (DS OF DAM): 1 % ACE: 284 8' 1 % ACE FC: 286 9' BEE (US. OF DAM, NO RANGE (LAKE))): 1 % ACE: 360-1 1 % ACF FC: 360 1 PROJECT ENGINEER: D. C. HOPKINS 60%DESIGN REVIEW DO NOT USE FOR CONSTRUCTION Hza&nCITY - HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0361 DEPARTMENT OF WATER MANAGEMENT OF DURHAM, NORTH CAROLINA LITTLE RIVER PUMP STATION CIVIL OVERALL SITE PLAN DATE: DECEMBER 2020 DESIGNED BY: C. WILSON HAZEN No: 31306-001 DRAWN BY: C. WILSON CONTRACT NO 1 LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS : CHECKED BY M. SANTOWASSO DRAWING NUMBER CO20 IF THIS BAR DOES NOT 0 1/2' 1• MEASURE l'THEN DRAWING IS NOT TO FULL SCALE REV ISSUED FOR DATE BY r I, ELEC GENERATOR 1 _ l � �l 1 RAW WATER PUMP FEW, 1%ACF / ,ri' # STATION SEE NOTE 4, DWG CO20 % FEMA 1%ACF FC SEE NOTE 4, DWG > m RESTORE ASPHALT ROADWAY AS NEEDED SEE WrE 1 C-32-0551 LIMITS OF DISTURBANCE, TYP PROJECT ENGINEER: D C HOPKINS DESIGNED BY C. WILSON DRAWN BY: C. WILSON 60% DESIGN REVIEW CHECKED BY: M. SANTOWASSO DO NOT USE FOR CONSTRUCTION ' IF THIS BAR DOES NOT V2' 1' MEASURE V THEN DRAWING � DATE By IS NOT TO FULL SCALE Iffill"A WAN.", 1 �. rr,I ` ,' • ' SDMH RIM 2B640 INV IN: 2B072 IIIV [;Y1T �eum ^ � 1 }` 1 41 iNSiRi�nr�vAULT SEE DWG M022 I I li l •� Hazen s HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0361 .? J It I I � f ire , v DEPARTMENT OF WATER MANAGEMENT CITY OF DURHAM, NORTH CAROLINA — LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS NOTES: It CONTRACTOR SHALL RESTORE ALL ROADWAY AND SITE FEATURES WITHIN THE LIMITS OF DISTURBANCE UPON COMPLETION OF ALL CONSTRUCTION ACTIVITIES. LITTLE RIVER PUMP STATION CIVIL SITE PLAN DATE: DECEMBER 2020 HAZENNO-: 31306_001 CONTRACTNO: 1 DRAWING NUMBER: i' f I � l i CABIN BRANCH DRIVE LITTLE RIVER RESERVOIR J' x 3 O 2 PROJECT ENGINEER: D. C HOPKINS DESIGNED BY: D. C. HOPKINS DRAWN BY: K.OVERBY 60% DESIGN REVIEW DO NOT USE FOR CONSTRUCTION CHECKED BY J. McCARTHY IF THIS BAR DOES NOT 0 112" 1" MEASURE 1"THEN DRAWING Imsiamm ISSUED FOR DATE BY IS NOT TO FULL SCALE OVERALL YARD PIPING PLACE 1" = 10W-0" Hazen HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, SUITE 500 RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-0381 SPILLWAY SEE DRAWING SERIES M200 DEPARTMENT OF WATER MANAGEMENT CITY OF DURHAM, NORTH CAROLINA LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS NOTES, 1- EXISTING SURFACE CONDITIONS SHOWN BASED ON RECENT SURVEY SEE CIVIL DRAWINGS FOR DETAILED SURVEY INFORMATION, SMALL DIAMETER UNDERGROUND UTILITIES SHOWN IN THIS SERIES BASED ON DEPARTMENT OF WATER RESOURCES CITY OF DURHAM, NC LITTLE RIVER DAM AND RESERVOIR CONTRACT NO 4 RECORD DRAWINGS DATED APRIL 1984 NOT ALL SITE FEATURES AND UTILITIES ARE --_ SHOWN ON THESE DRAWINGS 2. 2" POTABLE WATER LINE SHALL BE INSTALLED APPROXIMATELY 5'-0. OFF ACCESS ROAD FIELD LOCATE CENTERLINE OF PIPE SUCH THAT INSTALLATION OF PIPE DOES NOT DISTURB ACCESS ROAD ASPHALT, STORM DRAINAGE PIPES, LIGHT POLES, OR FENCE POSTS, 3'-O' MINIMUM DEPTH OF `1 COVER ALONG THE ENTIRE LENGTH OF PIPE 3 CONTRACTOR SHALL FIELD LOCATE VALVE BOX FOR TIE IN TO CITY WATER 1� f `— ,Y UK tNLANUtU YAKU VIVINU PLAN, SEE DRAWING M022 �'f LITTLE RIVER SITE WORK MECHANICAL OVERALL YARD PIPING PLAN 100 50 0 100, 1-•yoo•.o- F-.-.ri.-..-.d- I DATE DECEMBER 2020 HAZEN NO: 31306-001 CONTRACT NO: 1 DRAWING NUMBER: M020 CLEAR STEM COVER ELECTRIC SLUICE /l GATE ACTUATOR EL 365 00 11 a u FULL) VATION SECTION M252 EL 379 00 A " u EI 11 � EI I 11 I fj I I I I it 11 11 , I I� ! 11 I II I H I1 11 1� I II 11 I 4 4 II II II II 111 11 1 11 ' I II I 1 1 I I 1 I I I I II I � ` EL 34200 SECTION D IIA' - 1'•0' T2 f 1! I! u 11 II I I II NOTES: 1. CONTRACTOR SHALL ADJUST THE WEDGES OF EXISTING INTAKE DRAIN GATE TO ELIMINATE DOWNSTREAM LEAKAGE THECONTRACTOR SHALL REMOVE THE EXISTING BARRACK LOCATED ON THE EXTERIOR FACE OF THE INTAKE TOWER PROTECTING THE GATE TO COMPLETE THE WEDGE ADJUSTMENTS. CONTRACTOR SHALL REPLACE THE BARRACK HARDWARE AND FIRMLY SECURE THE BARRACK TO THE TOWER FOLLOWING COMPLETION AND VERIFICATION THAT THE WEDGE ADJUSTMENTS HAVE ADDRESSED THE GATE LEAKAGE ISSUE I II el If I I 6'-0" x B'-0" SlU10E DATE 8 GATEINVERT EL 342 00 6-0" xx &-0' SLUICE PATE W GATf R&EM ELM,50 Lat- GATE OPERATOR STEM WALL RACKET- TVP 6-W x B'-W SLUICE GATE GATEINVERT EL 295 00 EL 276 00 GATE STEM ELEVATION Ti'. V-11 PROJECT D. C. HOPKINS ENGINEER' 60% DESIGN REVIEW Do NOT USE FOR CONSTRUCTION Hazen HAZEN AND SAWYER 4011 WESTCHASE BOULEVARD, RALEIGH, NORTH CAROLINA 27607 LICENSE NO.: C-03B1 DEPARTMENT OF WATER MANAGEMENT CITY OF DURHAM, NORTH CAROLINA LAKE MICHIE AND LITTLE RIVER RAW WATER PUMP STATION IMPROVEMENTS INTAKE STRUCTURE MECHANICAL SECTIONS DATE: DECEMBER 2020 DESIGNED BY: D.C.HOPKINS HAZEN NO 31306-001 DRAWN BY: K. OVERBY CONTRACT NO.: 1 CHECKED BY: J. McCARTHY DRAWING NUMBER: d IF THIS BAR DOER NOT 0 1/2" 1" MEASUREI'THENDRAWING IS NOT TO FULL SCALE o C a REV ISSUED FOR DATE By