Loading...
HomeMy WebLinkAbout20100251 Ver 2_Stormwater Info_201203231 I TIMMONS GROUP. 00 04D 00 YOUR VISION ACHIEVED THROUGH OURS • 0 • 5410 Trinity Road, Suite 112, Raleigh, NC 27607 To NCDENR - DWQ 1 O - O a,S 1 U?- Wetlands and Stormwater Branch Attn Ms Annette Lucas 512 N Salisbury St (9t" Floor) Raleigh, NC 27604 From Andrew Moriarty, PE Project Harnett Health Sciences Budding Enclosed Please Find Comments Ms Lucas Please find the attached documents for a modification for existing permit 10 0251v2 Please let us know if you need additional information or have any questions Thanks c�c�r�ad� o MAR 2 6 2012 SIGNED ' Andi-4 Moriarty, PE DATE 2 3 23 12 Modified Stormwater Construction Drawings 1 Cover letter 1 BMP Supplement 1 Calculation Package w /Narrative, Quad Map, Soils Information Comments Ms Lucas Please find the attached documents for a modification for existing permit 10 0251v2 Please let us know if you need additional information or have any questions Thanks c�c�r�ad� o MAR 2 6 2012 SIGNED ' Andi-4 Moriarty, PE TIMMONS GROUP YOUR VISION ACHIEVED THROUGH OURS March 23, 2012 North Carolina Department of Natural Resources Division of Water Quality Wetlands and Stormwater Branch 1650 Mail Service Center Raleigh NC 27604 Re Harnett Health Sciences Building (Previously approved as 10 0251v2) Dear Ms Lucas Timmons Group wishes to submit documentation for a modification to the existing NCDENR stormwater permit 10 0251v2 We plan to develop a portion of the Brightwater Biotechnology and Medical Center in Harnett County NC that was previously labeled as future construction This proposed development is located northeast of the intersection of Matthews Road and Crested Ins Drive As part of this construction additional stormwater management will be required To facilitate these requirements Timmons Group has proposed an expansion to the existing BMP #2 to provide the additional water quality treatment volume for the first flush of runoff generated from additional impervious area For your review we have included revised Stormwater Management BMP construction drawings calculations and supplement forms Please let us know if there is any other information you need for your review If you have any questions or concerns about this modification please do not hesitate to give me a call at (919) 866 4932 �D MAR262012 nds $ Sto k QU, 7' Best Regards �Ws drewMonartyy PE Project Manager Permit No (to be pro ded by DWQ) LT-WA TA o��F W A TF9OG NCDENR p STORMWATER MANAGEMENT PERMIT APPLICATION FORM 401 CERTIFICATION APPLICATION FORM WET DETENTION BASIN SUPPLEMENT This form must be filled out printed and submitted The Required Items Checklist (Part III) must be printed filled out and submitted along with all of the required information I PROJECT INFORMATION Project name Hamett Health Sciences Bldg Contact person Mr Andrew Moriarty Phone number 919- 866 -4951 Date 3/23/2012 Drainage area number Wet Pond 2 II DESIGN INFORMATION ft3 /sec Site Characteristics ft3 /sec Drainage area 276171 fe Impervious area post development 184 694 ftz / Impervious 6688 / Design rainfall depth 10 in Storage Volume Non SA Waters Minimum volume required 15 003 ft3 OK Volume provided 16 469 ft3 OK volume provided is equal to or in excess of volume required Storage Volume SA Waters 15 runoff volume ft3 Pre development 1 yr 24 hr runoff ff3 Post development 1 yr 24 hr runoff ff3 Minimum volume required ft3 Volume provided ft" Peak Flow Calculations Is the pre /post control of the 1 yr 24hr storm peak flow required? N (Y or N) 1 yr 24 hr rainfall depth In Rational C pre - development (unitless) Rational C post - development (unitless) Rainfall Intensity 1 yr 24 hr storm In /hr Pre development 1 yr 24 hr peak flow ft3 /sec Post - development 1 yr 24 hr peak flow ft3 /sec Pre /Post 1 yr 24 hr peak flow control ft3 /sec Elevations Temporary pool elevation 16150 fmsl Permanent pool elevation 16050 fmsl SHWT elevation (approx at the pens pool elevation) 16000 fmsl Top of 1 Oft vegetated shelf elevation 16100 fmsl Bottom of 1 Oft vegetated shelf elevation 16000 fmsl Sediment cleanout top elevation (bottom of pond) 15500 fmsl Sediment cleanout bottom elevation 15400 fmsl Sediment storage provided 1 00 ft Is there additional volume stored above the state required temp pool? N (Y or N) Elevation of the top of the additional volume fmsl Forth SW401 Wet Date t o Bas n Re 8-9/17/09 Parts I & 11 Des g S mmary Page 1 of 2 II DESIGN INFORMATION Surface Areas Area temporary pool Area REQUIRED permanent pool SA/DA ratio Area PROVIDED permanent pool Apermyoo Area bottom of 1 Oft vegetated shelf Abot shelf Area sediment cleanout top elevation (bottom of pond) Ah�t- d Volumes Volume temporary pool Volume permanent pool Vpe --Pw Volume forebay (sum of forebays if more than one forebay) Forebay / of permanent pool volume SA/DA Table Data Design TSS removal Coastal SA/DA Table Used? Mountain/Piedmont SA/DA Table Used? SA/DA ratio Average depth (used in SA/DA table) Calculation option 1 used? (See Figure 10 2b) Volume permanent pool VP,,,Od Area provided permanent pool APe„m -pool Average depth calculated Average depth used in SA/DA dam, (Round to nearest 0 5ft) Calculation option 2 used? (See Figure 10 2b) Area provided permanent pool AP.-P., Area bottom of 1 Oft vegetated shelf Amt h if 17 882 ft 10 633 ft 385 (unitless) 14 047 ff OK 11 280 ft' 2 451 W 16 469 ft3 OK 31456 ft3 13191 ft3 419/ / Insufficient forebay volume 90 / N (Y or N) Y (Y or N) 385 (unitless) N (Y or N) 31456 ft' 14 047 ft' ft ft Y (Y or N) 14 047 ft' 11 280 ft' Area sediment cleanout top elevation (bottom of pond) Ab tl d 2 451 ft2 Depth (distance b/w bottom of 10ft shelf and top of sediment) 5 00 ft Average depth calculated 3 50 ft Average depth used in SA/DA d (Round to nearest 0 5ft) 35 ft Drawdown Calculations Drawdown through onfice? Diameter of onfice (if circular) Area of onfice (if non - circular) Coefficient of discharge (CID) Dnving head (H ) Drawdown through weir? Weir type Coefficient of discharge (C ) Length of weir (L) Driving head (H) Pre - development 1 yr 24 hr peak flow Post development 1 yr 24 hr peak flow Storage volume discharge rate (through discharge onfice or weir) Storage volume drawdown time Additional Information Vegetated side slopes Vegetated shelf slope Vegetated shelf width Length of flowpath to width ratio Length to width ratio Trash rack for overflow & onfice? Freeboard provided Vegetated filter provided? Recorded drainage easement provided? Capures all runoff at ultimate build -out? Drain mechanism for maintenance or emergencies is Y (Y or N) 250 in in 060 (unitless) 100 ft N (Y or N) ( unitless) ( unitless) ft ft ft3 /sec ft'/sec ft'/sec 2 68 days Need 3 ft min OK OK OK draws down in 2 5 days Permit No (to be pro ded by DWQ) 3 1 OK 10 1 OK 100 ft OK 3 1 OK 25 1 OK Y (Y or N) OK 15 It OK N (Y or N) OK N (Y or N) Insufficient Recorded drainage easement required Y (Y or N) OK Emergency drain and pump Form SW401 Wet Detention Basin Re 8- 9/17109 Parts I & 11 Des gn S mmary Page 2 of 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Storm Water Calculations Harnett Health Sciences Building Lillington, NC Prepared for Harnett Forward Together Committee March 2012 CITimmons Group 2012 3 12 yGINE� dK�` 7 l C o L & OW p MAR 2 6 2012 DENR WATER QUALITY Wetlands & 3t rmwate Branch 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 HARNETT HEALTH SCIENCES BUILDING LILLINGTON, NC STORM WATER CALCULATIONS Prepared for HARNETT FORWARD TOGETHER COMMITTEE Prepared by TIMMONS GROUP 5410 TRINITY ROAD, SUITE 112 RALEIGH, NORTH CAROLINA 27607 March 2012 Timmons Project No 31596 1 1 1 1 1 1 1 1 1 J This document, together with the concepts and designs presented herein, as an instrument of ' service, is intended only for the specific purpose and client for which it was prepared Reuse of and improper reliance on this document without written authorization and adaptation by Timmons Group shall be without Lability to Timmons Group 1 ' TABLE OF CONTENTS STORMWATER NARRATIVE ' FIGURES USGS QUADRANGLE MAP ' SOILS SURVEY ' HARNETT HEALTH SCIENCES BUILDING WET POND CALCULATIONS WATER QUALITY CALCULATIONS ' WATER QUANTITY CALCULATIONS ' APPENDICIES EROSION CONTROL MATTING 1 I 1 1 1 1 I C 1 1 1 Li I 1 1 1 Storm Water Narrative Background This report contains the approach and results of a stormwater analysis conducted for the proposed Harnett Health Science Building project located near the town of Lillmgton in Harnett County North Carolina The project consists of a new building and parking lot This report outlines the measures necessary for this development The Health Science building is located at the northeast corner of Matthews Road and Crested Ins Drive in the Brightwater Biotechnology and Medical Center complex The site currently is wooded and approximately 4 5 acres The proposed wet detention pond is to be located on the southwest side of Crested Ins drive by enlarging an existing wet detention pond The site area for the wet pond is approximately 1 acre bringing the total site area to approximately 6 5 acres Soils The Harnett County Soils Survey indicates that the primary near surface soils present on the site are Goldsboro loamy sand (GoA) and Norfolk loamy sand (NoB) and are both classified as hydrologic group B by the Soils Survey Curve Numbers for the site have been based on the good condition Site Stabilization After final grading is completed permanent vegetation shall be applied to stabilize the site until further work commences Drainage Areas This site consists of a single drainage area consisting of approximately 6 34 acres In the post development condition a curve number of 98 is given to impervious areas and a curve number of 61 is given to all landscaped areas Drainage Areas Sub Basin Drainage Area (ac) Impervious Area (ac) Pervious Area (ac) Post Dev 634 424 21 Wet Detention Pond Water Ouality This project is located within a WS W watershed and therefore has been designed to treat the first flush (1 rainfall) of runoff of the site at a 90% TSS removal efficiency This adheres to regulations 1 1 1 1 u I 1 1 1 1 11 and requirements set forth by NCDWQ Since this wet pond is designed for 90% TSS removal no level spreader or vegetative filter strip have been provided The wet detention pond has a permanent pool elevation of 160 50 and a temporary water quality elevation of 161 50 A 2 5 onfice has been placed at elevation 16150 to allow the water quality volume to draw down over a period of 2 5 days as required Wet Detention Surface Area Surface Area Water Quality Water Quality Drawdown Basin Required Provided Volume Volume Time 100 (SO (SO Required (cf) Provided (cf) (Days) A 10 633 14 047 15 003 16 469 268 The remaining runoff will be stored and released in the wet detention pond by a concrete riser structure A ten foot (10 ) vegetated safety bench has been included per NCDWQ requirements from elevation 160 00 to elevation 16100 The seasonal high water table has been determined to be at an approximate elevation of 160 0 Since this is within 6 of the permanent pool elevation no lmer is required to help ensure the wet detention pond is able to retain water and preserve aquatic plant growth Please reference the water quality calculations of this report for further details and calculations Wet Detention Pond Water Ouanhty Per NCDWQ standards no reduction in peak runoff is required for this site Runoff rates are included in the table below for reference only Drainage Basin Storm Event (yr) Post development Rate (cfs) Maximum WSEL (ft) 1 963 161 83 2 1253 16190 10 2366 16212 100 4008 162 52 A 4 x 4 concrete riser structure has been designed to accommodate up to the 100 year storm event The top of this riser structure has been set at the top of the temporary storage volume (elevation 161 50) The 100 year storm even has been designed to stage to a maximum water surface elevation of 162 45 which provides 16 feet of freeboard to the top of the wet detention basm Please reference the corresponding section of this report for further details and calculations 1 IConclusion Based on the analysis provided herein the proposed storm water measures and facilities address the storm water requirements of the NCDWQ I 1 1 1 u 1 1 t 1 r 1 1 1 1 7 1 1 [I 1 1 FIGURES 1 1 1 1 1 1 1 1 1 1 1 1 A 91 w car Cape Fear # 140 Plant N ington Sewage Copyright (C) 1997, Maptech, Inc. ,,L£ .94 AL ZS 9D 9L b N N N � N m N � N N l�+I l0 N ..L£ .94 AL d io N d d LL O O 0 t7 d L O m N m O � O N N Q O a � O C � n N Cl) O O N L O cn 0 7 d - T N 7 >` O > U) 7 > D O N (n O_ O N O U m 0 O Z 0 0 0 rn 0 N ai N U U d n m 7 f o o O C fA O i7 � to my 7 N m C Z� ZU A ..ZS .94 ,9L C_ O a3 U r Z T C _ O U a� c I n O w Z O NC I.L O LL Z a CQ G cl Z W 0 W J a aJ a) L H LO a) N Q 0 CL a) C n O Q) ui U 2 N _C O) —_ C O N l0 N N O 7 ` U ° C U U U U a3 N O � U W W n as n d U N O a3 U) E m or y o C01 E O a> 'Q w E m m nL m O U N m E is m al > p C ° o 3 N O L C O N C N O d m n a M E a''- p- m CL N ° m > m E 0)EL o L a o c a o (n E m E c E w C °> � @ = U y LA w E n n o m m E N U) ca t > u Y6 f6 a) w m a N O .G ns N O O C ch — O C p ul ` U fE C — N N U E w 0 O D _ ID I u a U) O N a) O N N or❑ Z U o N L E N m O= Z Q � N L d E L N' Z a) N r � z N > a c y 0 o Q N N O )a 0 3 0 3 0 r O E 2' N ° a) y p_ N E _O `O p U C o d a) a) D E L � L a) T @ L „' L � a) ` E O a' O N IQ � C, N @ ❑ f0 J aai (6 y ° = > N L a) c .LD L Z ❑ E a) = c o N O N -_ -p ° T m m O m 'E °° m 0 O c Z M= me -° Q m N L a a L >° N E d c O > 2 Z 'y a7 a m n p C 2 N O C_ O 'O O ` a a) T N L 'n N H mas U � -,`o w> (n a) —Z ° O f6 a)E mE a� a) a E 0 0 0 Lo 3: U L N H w U(D) to N ❑ L O H U .E o V KY. O O N N � a) r O) M ai T a) _ >' O a) C/) = > a7 O � � n a O a) O �U io c O Z d L) H d � L N 3 O = N a) � m y N C 2U f 1, N N � C N Z U) u a U) U L rn N c N a7 N N a7 )a O O to o" � 3 N O u) y E N o O �_ O a' >, N lL T C y N a N a' O a7 L N > O _ ai c CD O o L u) O d i U N ` c N C n c (a y S UJ :5 i U O A LL a) r �j V 1 U m � S _ y LL O a .O r N a a7 3 ` � O c m` 0 ) N N y N E {a o a) jp d a) — c a ° m y a 3 m O v `. a o vai �. ° 3 o a L m 3 Q aoi ca E o U O n y a 0 uJ .o. o nt o LL 0 O cn a) 'O o` al c a7 Vl Np 3 C O `O T N a7 O > la > N C m > a) C_ U In a1 y U C c a) > c a V O O ID ¢ u) '0 m m U 0 (D i.) J J � � � a � (n (n u) m In () (n (n m C a � e U fA V KY. O O N N � a) r O) M ai T a) _ >' O a) C/) = > a7 O � � n a O a) O �U io c O Z d L) H d � L N 3 O = N a) � m y N C 2U f 1, Sod Map —Hamett County North Carolina 1 Map Unit Legend t 1 Harnett County North Carolina (NC085) Map Unit Symbol Map Unrt Name Acres in AOI Percent of AOI ExA Exum very fine sandy loam 0 to 2 percent slopes 01 27/6 GoA Goldsboro loamy sand 0 to 2 percent slopes 15 262/6 NoB Norfolk loamy sand 2 to 6 percent slopes 40 71 1/6 Totals for Area of Interest 661 1000-/ ' USDA Natural Resources Web Sod Survey 3/15/2012 am Conservation Service National Cooperative Sod Survey Page 3 of 3 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 c y o U r r dz LL 2:1 L C 0 3 c0 N N N N N N N N N N N N N 07 N N N N N N c c c c C C C c c c c C c c c c c c c c 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 z z z z z z z z z z z z z z z z z z z z N d N N N N N N N N N N N N N N N N d N c c c c c c c c c c c c c c c c c c c c Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z iz I I I i I I I I I I I I I I I I 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 CC O co co co co c0 co co co co co co co co co co co co co co A A A A A A A A A A A A A A A A A A A A 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 M M M 0 (AO M M M M� 0 0 M CD (AD co co co (0 li 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Cl) Cl) M O O Cl) N N N Cl) N N N N M N M M M It V M 2 s m a a s r a s m E m 2 oi °ck m 2 E m m(U c M O' CD c m m `m c m O d aEi m O O c o 0 -ALL z �1L2�2za �t12�zO J J J U E J i W 1 m O a m Y z Z � O CL E 6 5 c 0 0 a c o L _o a� `m > 7 B a m M c0 7 a m N u a� 0 a� ZU f� II 1 1 1 1 F 1 WATER QUALITY CALCULATIONS 1 ' Wet Detention Basin Design Summary P oject Informat o Project Name Harnett County Health Sc ences Timmons Project It 31596 Des gned by D A Id D t 3/22/2012 ' Re sed by D Arnold Date 3/22/2012 Checked by D Arnold Date 3/22/2012 Des gn Resource NCDENR St rmwat Best M gem t P b Ma I (J ly 2007) S to Inforrnat o S b Area Location Harnett H alth Sc ences Bu Id ng Dra nage Area (DA) 634 Acres Impery o s Area (IA) 4 240 Acres Percent Impery o s (1) 669% Req red Storage Volume (Water Qual ty) Des gn Storm 1 rich Determ ne R Value 005 009(l) 065 n/ n t Storage Vol me Required 15,003 d (abo a Permanent Pool) Req red S rface A as Average Depth 30 it ' SA(DA 385 (90% TSS Removal via Pond) M n Req d Surface Area 10,633 sf (at Permanent Pool) Requ red Length to W'dth Rat o 15 to 1 ' Pretreament De ce Forebay Req fired Forbay S ng Req red Volume 2000% of Permanent Pool Permanent Pool Volume 31 456 d ' Requ red Forbay Vol me 6 291 d Summary of Proposed Pond Bottom of Pond Elevat on 15500 ft Sed ment Storage Depth Permanent Pool Ele at on 100 It ft 16050 Temporary Pool Elevation 16150 It Top of Pond Elevat on 164 10 ft Permanent Pool S rface Area 14,047 sf 14047 sf 10633 sf Temporary Pool (wat r q at ty storage) 16,469 d 16469 d 15003 d Area @ Top of Temporary Pool 17,882 sf S de Slopes of Pond 3 1 Vol me of Fo ebay 13,191 d Forebay % V I me 39% d A erage Depth 35 ft tAnt Flotation Device R ser W dth 4 k R see Length 4 k Top R ser Eta 16150 B it m R El 15600 ft He ght of R ser 550 ft Area of R r 160 f (W t D pl ced) Vol me of R ser 880 cf (W t D p1 d) Factor of Safety 3 W ght 54912 lb Weight Req d f om Ant Flotat on De ce 164736 Ib 'We ght of R ser 20477 lb (V I m R W e B y t Wt ) Add t nal Vol me of Concrete Req d 1647 cf (B y t Wt C et (150 62 4) pcf) Extend R ser 3 ft Volume of R ser EMens on 480 d Volume of Ant flotat on 8 x8 x2 Co crate Slab 1280 Vol me Pro tied 1760 1 Is the Ant flotation Dev ce Suffrxent (yes/no)) Yes 1760 As m 6 w 11 th It es w th b y t w ght of cr t (150 62 4) pcf 1647 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Wet Detention Basin INCREMENTAL DRAWDOWN METHOD Project Information Project Name Harnett Health Sciences Budding Timmons Protect # 31596 Designed by D Arnold Date 3/22/2012 Checked by D Arnold Date 3/22/2012 Water Quality Orifice Incremental Determination of Water Quality Volume Drawdown Time Zone 2 Orifice Diameter (D) _ Cd = Ei = Zone 1 Range= Zone 2 Range = Zone 3 Range = 25 in 06 Countour 1605 Orifice Inv 15500 to 1605 to 160 7083333 to Q3 = 0 0437 Co D2 (Z D/24 E))^(112) Q2 = 0 372 Co D (Z Ei) ^(312) Qi = 0 1605 1607083 1615 Incremental Drawdown Method Countour Contour Area Incremental Volume Stage Z Zone Q Drawdown Time sq ft cu ft ft cfs min 16050 14 047 0 000 2 0 000 16060 14 632 1 434 010 2 0 018 1 354 16070 15 217 1 1 492 020 2 0 050 498 16080 15 803 1 551 030 3 0 073 356 16090 16 388 1 610 040 3 0 089 301 161 00 16 973 1 668 050 3 0 103 270 161 10 17 154 1 706 060 3 0 115 246 161 20 17 335 1 724 070 3 0 126 227 161 30 17 517 1 743 080 3 0 137 212 161 40 17 699 1 761 090 3 0 146 201 161 50 17 882 1 779 100 3 0 155 191 Total 16 468 3 858 Drawdown Time = Incren Summary Total Volume = Total Time = Total Time = Max Q= rental Volume / Q / 60sec/min 16 468 cf 3 858 min 2 68 days 0 155 cfs 1 1 Wet Detention Basin Basin Areas and Volumes Project Information Project Name Harnett Health Sciences Budding Timmons Project # 31596 ' Designed by D Arnold Date 3/22/2012 Checked by D Arnold Date 3/22/2012 1 I 1 1 1 1 1 1 1 1 1 1 Permanent Pool Temporary Pool Spillway Pond Storage Incremental Accumulated Countour Contour Area Volume Volume S Stage Z sq ft cu ft cu ft ft 16050 14 047 0 0 000 161 00 16 973 7 755 7 755 050 16150 17 882 8 714 16 469 100 16200 18 804 9 172 25 640 1 50 16300 20 692 19 748 45 388 250 16400 22 636 21 664 67 052 350 Permanent Pool Temporary Pool Spillway Deep Pool Incremental Accumulated Countour Contour Area Volume Volume S Stage Z sq ft cu ft cu It It 15500 1 180 0 0 550 15600 2030 1 605 1 605 450 15700 2 935 2 483 4 088 350 15800 3 897 3 416 7 504 250 15900 4 916 4 407 11 910 1 50 16000 5 991 5 454 17 364 050 16050 7 124 3 279 20 642 000 Foreba Incremental Accumulated Countour Contour Area Volume Volume S Stage Z sq ft cu It cu ft ft 15600 1 270 0 0 450 15700 1 890 1 580 1 580 350 15800 2 623 2 257 3 837 250 15900 3 486 3 055 6 891 1 50 16000 4 359 3 923 10 814 050 16050 5 152 2 378 13 191 000 Permanent Pool Temporary Pool Spillway 1 1 1 1 1 1 1 1 1 1 1 WATER QUANTITY CALCULATIONS 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Type Master Network Summary Page 1 01 Name Watershed File R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R MASTER DESIGN STORM SUMMARY Network Storm Collection Washington NC MASTER NETWORK SUMMARY SCS Unit Hydrograph Method ( Node = Outfall +Node = Diversion ) (Trun= HYG Truncation Blank =None L =Left R =Rt LR= Left &Rt) Total Depth Rainfall Max Return Event in Type Return RNF ID 1 3 3000 Synthetic Curve TypeIII 24hr 2 3 8900 Synthetic Curve TypeIII 24hr 10 5 9900 Synthetic Curve TypeIII 24hr 100 9 9600 Synthetic Curve TypeIII 24hr MASTER NETWORK SUMMARY SCS Unit Hydrograph Method ( Node = Outfall +Node = Diversion ) (Trun= HYG Truncation Blank =None L =Left R =Rt LR= Left &Rt) SIN Bentley Systems Inc Bentley PondPack (10 00 027 00) 2 04 PM 3/22/2012 Max Return HYG Vol Qpeak Qpeak Max WSEL Pond Storage Node ----------- ID - - - - -- Type - - -- Event - ac -ft Trun min cfs ft ac -ft POST BASIN AREA - - - -- 1 ---- - - 1 - - -- -- 016 --- - - - 726 - -- 00 -- - - - - -- -- - - - - -- ------ - - - - -- 12 61 POST BASIN AREA 2 1 293 726 00 15 91 POST BASIN AREA 10 2 325 726 00 27 78 POST BASIN AREA 100 4 354 726 00 50 01 POST OUTFALL JCT 1 1 389 729 00 9 63 POST OUTFALL JCT 2 1 666 729 00 12 53 POST OUTFALL JCT 10 2 698 729 00 23 66 POST OUTFALL JCT 100 4 727 729 00 40 08 WET POND IN POND 1 1 016 726 00 12 61 WET POND IN POND 2 1 293 726 00 15 91 WET POND IN POND 10 2 325 726 00 27 78 WET POND IN POND 100 4 354 726 00 50 01 SIN Bentley Systems Inc Bentley PondPack (10 00 027 00) 2 04 PM 3/22/2012 1 1 1 1 i 1 1 1 1 1 1 1 1 1 1 Type Master Network Summary Page 1 02 Name Watershed File R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R MASTER NETWORK SUMMARY SCS Unit Hydrograph Method ( Node = Outfall +Node = Diversion ) (Trun= HYG Truncation Blank =None L =Left R =Rt LR= Left &Rt) SIN Bentley PondPack (10 00 027 00) 2 04 PM Bentley Systems Inc 3/22/2012 Max Return HYG Vol Qpeak Qpeak Max WSEL Pond Storage Node- ID--- Type Event Trun min cfs -ft - - - -- WET POND - - - - -- OUT - - -- POND - - - - -- 1 ---ac-ft 1 - - -- 389 -- L - -- - -- 729 00 -- - -- 9 63 -- -ft 161 - -- 83 -- -ac - - -- 516 WET POND OUT POND 2 1 666 L 729 00 12 53 161 90 547 WET POND OUT POND 10 2 697 L 729 00 23 66 162 12 640 WET POND OUT POND 100 4 726 L 729 00 40 08 162 52 819 SIN Bentley PondPack (10 00 027 00) 2 04 PM Bentley Systems Inc 3/22/2012 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Type Name File Runoff CN -Area POST BASIN Page 1 01 R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R RUNOFF CURVE NUMBER DATA -------------------------------------------------------------------------- Impervious Area Adjustment Adjusted Soil /Surface Description CN acres C %UC CN -------------------------- - - - - -- - - -- --- - - - - -- - - - -- - - - -- - - - - -- Impervious Areas - Paved parking to 98 4 240 98 00 Fully Developed Urban Areas (Veg Es 61 2 100 61 00 COMPOSITE AREA & WEIGHTED CN - - -> 6 340 SIN Bentley PondPack (10 00 027 00) 2 04 PM 85 74 (86) Bentley Systems Inc 3/22/2012 1 1 1 1 1 1 1 1 1 1 1 1 Type Outlet Input Data Name Post A Outlet Page 1 01 File R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R REQUESTED POND WS ELEVATIONS Min Elev = 160 50 ft Increment = 20 ft Max Elev = 164 00 ft OUTLET CONNECTIVITY - - -> Forward Flow Only (UpStream to DnStream) < - -- Reverse Flow Only (DnStream to UpStream) i< - - -> Forward and Reverse Both Allowed Structure No Outfall El ft E2 ft ----------- - - - - -- - - -- - - - - - -- --- - - - - -- --- - - - - -- Inlet Box RO - - -> CO 161 500 164 000 Orifice - Circular 00 - - -> CO 160 500 164 000 Culvert - Circular CO - - -> TW 156 000 164 000 Weir- Rectangular WO - - -> TW 162 750 164 000 TW SETUP DS Channel S/N Bentley PondPack (10 00 027 00) 2 05 PM Bentley Systems Inc 3/22/2012 Type Name ' File 1 1 1 1 1 1 1 Outlet Input Data Post A Outlet Page 1 02 R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R OUTLET STRUCTURE INPUT DATA Structure ID = RO Structure Type - - - -= -Inlet -Box # of Openings = 1 Invert Elev = 161 50 ft Orifice Area = 16 0000 sq ft Orifice Coeff = 600 Weir Length = 16 00 ft Weir Coeff = 3 000 K Reverse = 1 000 Mannings n = 0000 Kev Charged Riser = 000 Weir Submergence = No Structure ID = 00 Structure Type - - - - =- Orifice - Circular ------------------------------------ # of Openings = 1 Invert Elev = 160 50 ft Diameter = 2 50 in Orifice Coeff = 600 SIN Bentley PondPack (10 00 027 00) 2 05 PM Bentley Systems Inc 3/22/2012 1 1 1 1 1 1 1 1 1 1 Type Name File Outlet Input Data Post A Outlet Page 1 03 R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R OUTLET STRUCTURE INPUT DATA Structure ID = CO Structure Type = Culvert - Circular No Barrels = 1 Barrel Diameter = 24 00 in Upstream Invert = 156 00 ft Dnstream Invert = 155 00 ft Horiz Length = 50 00 ft Barrel Length = 50 01 ft Barrel Slope = 02000 ft /ft OUTLET CONTROL DATA Mannings n = 0130 Ke = 2000 (forward entrance loss) Kb = 012411 (per ft of full flow) Kr = 2000 (reverse entrance loss) HW Convergence = 001 +/- ft INLET CONTROL DATA Equation form = 1 Inlet Control K = 0045 Inlet Control M = 2 0000 Inlet Control c = 03170 Inlet Control Y = 6900 T1 ratio (HW /D) = 1 085 T2 ratio (HW /D) = 1 187 Slope Factor = - 500 Use unsubmerged inlet control Form 1 equ below T1 elev Use submerged inlet control Form 1 equ above T2 elev In transition zone between unsubmerged and submerged inlet control interpolate between flows at T1 & T2 At T1 E1ev = 158 17 ft - - -> Flow = 15 55 cfs At T2 Elev = 158 37 ft - - -> Flow = 17 77 cfs SIN Bentley PondPack (10 00 027 00) 2 05 PM Bentley Systems Inc 3/22/2012 1 1 1 1 1 1 1 1 t t Type Name File Outlet Input Data Post A Outlet Page 1 04 R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R OUTLET STRUCTURE INPUT DATA Structure ID Structure Type # of Openings Crest Elev Weir Length Weir Coeff WO Weir- Rectangular 1 162 75 ft 20 00 ft 3 000000 Weir TW effects (Use adjustment equation) Structure ID = TW Structure Type -- - - = -TW -SETUP DS Channel ------------------------------------ FREE OUTFALL CONDITIONS SPECIFIED CONVERGENCE TOLERANCES Maximum Iterations= 40 Min TW tolerance = 01 ft Max TW tolerance = 01 ft Min HW tolerance = 01 ft Max HW tolerance = 01 ft Min Q tolerance = 00 cfs Max Q tolerance = 00 cfs SIN Bentley PondPack (10 00 027 00) 2 05 PM Bentley Systems Inc 3/22/2012 1 1 1 1 1 1 1 1 1 1 1 Type Name File Vol Elev -Area WET POND Page 1 01 R \102 \31596- Harnett County - Health Sciences Building \Calc \SWM \31596 HHS - BMP R Elevation Planimeter Area Al +A2 +sgr(A1 A2) Volume Volume Sum (ft) ---- --- (sq in) (sq ft) (sq ft) (ac -ft) (ac -ft) - 160 50 - - -------------------------------------------------------- - - - -- 14047 0 000 000 161 00 - - - -- 16973 46461 178 178 162 00 - - - -- 18804 53642 410 588 163 00 - - - -- 20692 59221 453 1 041 164 00 - - - -- 22636 64970 497 1 539 POND VOLUME EQUATIONS Incremental volume computed by the Conic Method for Reservoir Volumes Volume = (1/3) (EL2 -EL1) (Areal + Area2 + sq rt (Areal Area2)) where ELI EL2 = Lower and upper elevations of the increment Areal Area2 = Areas computed for ELI EL2 respectively Volume = Incremental volume between ELI and EL2 SIN Bentley PondPack (10 00 027 00) 2 05 PM Bentley Systems Inc 3/22/2012 1 APPENDICIES North American Green 14649 Highway 41 North Material and Performance Specification Sheet Evansville IN 47725 p 800 772 2040 AM FAX 812 - 867 -0247 GWO www nagreen com ' A to 1Sar Company S150 Erosion Control Blanket The short term double net erosion control blanket shall be a machine produced mat of 100% agricultural straw with a functional longevity of up to 12 months (NOTE functional longevity may vary depending upon climatic conditions soil geographical location and elevation) The blanket shall be of consistent thickness with the straw evenly distributed over the entire area of the mat The blanket shall be covered on the top and bottom sides with a lightweight photodegradable polypropylene netting having an approximate 0 50 x 0 50 (127 x 127 cm) mesh The blanket shall be sewn together on 150 inch (3 81 cm) centers with degradable thread The S150 shall meet requirements established by the Erosion Control Technology Council (ECTC) Specification and the US Department of Transportation Federal Highway Administration s (FHWA) Standard SpeaBcabons for Construction of Roads and Bridges on Federal Highway Projects FP 03 Section 71317 as a type 2 D Short term Double Net Erosion Control Blanket ' The blanket shall be manufactured with a colored thread stitched along both outer edges (approximately 2 5 inches [5-12 5 cm] from the edge) as an overlap guide for adjacent mats Material Content Matrix 100% Straw Fiber 0 5 I d2 0 27 kg/M2) Nettings Top and Bottom nets lightweight photodegradable 15 Ib/1000 ft2 ( 0 73 kg/100 m2) approx weight Thread Degradable 40 Ibs (18 14 kg) S150 is available in the following standard roll sizes Thickness Width 40ft (12m) 667ft (203m) 16ft (487m) Length 135 it (41 14 m) 108 it (32 92 m) 108 ft (32 92 m) Weight t 100/6 30 Ibs (13 6 kg) 40 Ibs (18 14 kg) 96 Ibs (43 54 kg) Area 60 yd2 (50 16 m2) 80 0 yd2 (66 9 m2) 192 yd2 (165 5 m2) Index Value Ponnarhen Property Test Method Typical Thickness ASTM D6525 0 36 in 914 mm -Resiliency ECTC Guidelines 805% Water Absorbency ASTM D1117 514% Mass/Und Area ASTM 6475 10 52 oz/ d2 357 7 /m2 Swell ECTC Guidelines 15% Smolder Resistance ECTC Guidelines Yes Stiffness ASTM D1388 6 06 oz in light Penetration ECTC Guidelines 98% Tensile Strength -MD ASTM D6818 169 2 Ibslft 2 51 kN /m Elon ation - MD ASTM D6818 172% Tensile Strength - TD ASTM D6818 164 4 Ibs/ft 2 44 kN /m Elongation - TD ASTM D6818 331% Bench Scale Testina INTPEPI Test Method Parameters Results ECTC Method 2 Rainfall 50 mm 2 in /hr for 30 min SLR = 8 04 1 00m 4 in )/hr for 30 min SIR =10 46 150 mm 6 in /hr for 30 min SLR" =13 67 ECTC Method 3 Shear Resistance Shear at 0 50 inch soil loss 21 Ibsfft2 ECTC Method 4 Germination Top Soil Fescue 21 day Incubation 484% Improvement of biomass Bench Scale tests should not be used for des n purpmes - Sod Loss Ratio Soil loss enth Bare Soil/Soil Loss with RECP sod loss is based on regression analysis) Updated 3/09 1 Performance Design Values Maximum Permissible Shear Stress Unve etated Shear Stress 175 Ibs /ft2 84 Pa Unvegetated Velocity 6 00 it/s 183 m/s Slope Desl n Data C Factors Flow Depth Slope Gradients S Sloe Length L s 31 31-21 z 21 s 20 it 6 m 0 004 0106 NA 20 50 it 0 062 0118 NA 2- 50ft 152m 012 0180 NA Roughness Coefficients. Unveg Flow Depth Manning s n s050ft 015m 0055 050 -20ft 0055 -0021 z20ft 0 60 ml 10021 Product Participant of aii