Loading...
HomeMy WebLinkAbout20210046 Ver 1_Ashe 355 structure plans for PCN_20210208The project will involve both mechanized pile driving and drilling to install the bridge bents. No explosives will be used. See structure plans on attached sheets. 15+50 16+00 16+50 17+00 17+50 18+00 2,780 2,790 2,800 2,770 2,810 FIX. (TYP.) EXCAVATION STRUCTURE UNCLASSIFIED (TYP.) STRUCTURE EXCAVATION OF UNCLASSIFIED 1'-6" TO LIMITS GRADE PT. EL. 2,794.69' STA. 15+70.48-L- FILL FACE @ END BENT No. 1 GRADE PT. EL. 2,794.71' STA. 15+62.25-L- BEGIN FRONT SLOPE STA. 15+70.48-L- W.P. 1 STA. 15+62.25-L- BEGIN FRONT SLOPE FIX.FIX.FIX.FIX.FIX.FIX.FIX. EL. 2,803.4' 100 YR. W.S. 1'-0" MIN. 1'-7" BERM EL. 2,786'|EL. 2,785'|EL. 2,784'|EL. 2,784'|EL. 2,784'|EL. 2,783'|EL. 2,785'|EL. 2,786'|EL. 2,793'|EL. 2,794'|EL. 2,792'| EL. 2,786.0' NORMAL W.S. EL. 2,795'| VERTICAL GRADE DATA -L- (-)0.3002%(+)0.3000% VC = 100'-0" EL = 2,795.26' PI = 13+80.00-L- VERTICAL GRADE DATA -L- (+)1.3504%(-)0.3002% VC = 100'-0" EL = 2,793.96' PI = 18+13.00-L- SECTION ALONG -L- SPAN D END BENT 2 SPAN A SPAN B SPAN C END BENT 1 BENT 1 BENT 2 BENT 3 GRADE PT. EL. 2,794.17' STA. 17+43.52-L- FILL FACE @ END BENT No. 2 GRADE PT. EL. 2,794.14' STA. 17+51.65-L- BEGIN FRONT SLOPE 1'-0" EARTH BERM STA. 16+11.86-L- W.P. 2 STA. 16+57.00-L- W.P. 3 STA. 17+02.14-L- W.P. 4 { BRIDGE STA. 16+57.00-L- BRIDGE ID STA. 17+43.52-L- W.P. 5 STA. 17+51.65-L- BEGIN FRONT SLOPE PC STA. 17+52.19-L- PT STA. 15+62.19-L- EL. 2,787.49' 1'-0" EARTH BERM EL. 2,787.42' (TYP.) 60°00'00" -L-1'-0"PILES (TYP.) HP 12x53 STEEL (2'-0" THK.)(TYP.) CLASS II RIP RAP(TYP.)3'-6"1 1.5 (TYP.)(KEY-IN)41'-4‹" SPAN D45'-1ƒ" SPAN C45'-1ƒ" SPAN B41'-4‹" SPAN A PILES NOT SHOWN IN PLAN VIEW FOR CLARITY. PLAN HYDRAULIC DATA: OVERTOPPING FLOOD DATA: OVERTOPPING FLOOD ELEVATION FREQUENCY OF OVERTOPPING FLOOD OVERTOPPING DISCHARGE * BASE HIGH WATER ELEVATION FREQUENCY OF BASE DISCHARGE BASE DISCHARGE DRAINAGE AREA DESIGN HIGH WATER ELEVATION FREQUENCY OF DESIGN DISCHARGE DESIGN DISCHARGE LOW CHORD ELEVATION EB1 EB2EL. 2,788'|* ON DECK/ROADWAY @ STA. 17+71-L-. OVERTOPPING OCCURS AT LOWEST HIGH POINT NEW RI VERS OUTH F ORK2,792.52'2,792.01' 1'-0" EARTH BERM 1'-0" EARTH BERM EL. 2,786.92' EL. 2,786.98' (TYP.) (TYP.) EARTH BERM (TYP.) DRILLED PIER 3'-0" ~ NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET OF 16+57.00-L- Placement Scale : SEAL ARE THE AS-BUILT PLANS. I HEREBY CERTIFY THESE PLANS PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION TGS ENGINEERS 804-C N. LAFAYETTE ST SHELBY, NC 28150 PH (704) 476-0003 CORP. LICENSE NO.: C-0275 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED 17BP.11.R.162 REPLACES BRIDGE NO. 040355 ASHE GENERAL DRAWING SR 1183 AND SR 1182 ON SR 1181 BETWEEN SOUTH FORK NEW RIVER FOR BRIDGE OVER S-1 32 SHEET 1 OF 4 CHECKED BY : DATE : DATE : DRAWN BY : MGC JLA 2/19 NAD 8 3/ 2 0 1 1 REPLACES BRIDGE NO. 040355 SECTION THRU END BENTS & BENTS ARE AT RIGHT ANGLES. EL. 2,793.2' 2 YR. W.S. 2,803.4' 100 YRS. 24,181 CFS 164 SQ. MI. 2,793.2' 2 YRS. 5,900 CFS 2,794.1' 2+ YRS. 7,000 CFS T O S R 1182 T O SR 11833/19 @ END BENT 1 FILL FACE @ END BENT 2 FILL FACE (TYP.) CLASS II RIP RAP (GRADE TO DRAIN)(TYP.) EXCAVATE TO EL. 2,789.0 GROUND LINE APPROX. NATURAL 173'-0…" TOTAL BRIDGE LENGTH (FILL FACE TO FILL FACE) (TYP.) PIER EL. 2,787.00 TOP OF DRILLED ACCESS TEMPORARY ACCESS TEMPORARY EL. 2,788.00 (TYP.) TOP OF TEMPORARY ACCESS STA. 17+54.22 TAN. EXT. END APPROACH SLAB STA. 15+59.78 TAN. EXT. BEGIN APPROACH SLAB PT STA. 15+62.19-L- PC STA. 17+52.19-L- WORKPOINT #1 DETAIL WORKPOINT #5 DETAIL STA. 15+70.48-L- W.P. 1 -L- @ EB1 FILL FACE * * IGNORE CURVE @ EB2 FILL FACE * IGNORE CURVE * STA. 17+43.52-L- W.P. 5 -L- EXTENDED TAN. EXTENDED TAN STATIONING OCCURS ALONG THE TAN. EXTENDED. IN ADDITION, THE CONTRACTOR SHALL ASSUME THAT ALL 2. COMPUTATIONS OF APPROACH SLAB ELEVATIONS 1. LAYOUT OF APPROACH SLAB AT END BENT 1 @ END BENT 1 FOR THE LAYOUT OF THE FOLLOWING: THE CONTRACTOR SHALL USE THE TANGENT EXTENDED STATIONING OCCURS ALONG THE TAN. EXTENDED. IN ADDITION, THE CONTRACTOR SHALL ASSUME THAT ALL 2. COMPUTATIONS OF APPROACH SLAB ELEVATIONS 1. LAYOUT OF APPROACH SLAB AT END BENT 2 @ END BENT 2 FOR THE LAYOUT OF THE FOLLOWING: THE CONTRACTOR SHALL USE THE TANGENT EXTENDED ENGINEER PROFESSIONAL SEAL NORTH CARO LINA 20125 .gll a hsramcheek,jr.DocuSign Envelope ID: 85F083B1-CA43-4429-86E7-06FEB2AC20B5 1/21/2021 STA. 15+70.48-L- W.P. 1 STA. 16+57.00-L- W.P. 3 STA. 17+43.52-L- W.P. 5 (TYP.) 60°00'00" 9'- 6" 9'- 6" 9'- 6" 9'- 6" { BRIDGE STA. 16+57.00-L- BRIDGE ID END BENT No. 1 FILL FACE @ 8'- 8• " 9• " 14'- 0" 14'- 0" 14'- 0" 14'- 0" 14'- 0" 14'- 0" 9'- 6" 9'- 6" 9'- 6" 9'- 6" 8'- 8• " 9• " END BENT No. 1 BENT No. 1 BENT No. 2 BENT No. 3 END BENT No. 2 FOUNDATION LAYOUT PLAN -L- { HP 12x53 STEEL PILES END BENT No. 2 FILL FACE @ 1'-4•" 1'-4•" { HP 12x53 STEEL PILES NOTES: NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET OF 16+57.00-L- Placement Scale : 32 PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION TGS ENGINEERS 804-C N. LAFAYETTE ST SHELBY, NC 28150 PH (704) 476-0003 CORP. LICENSE NO.: C-0275 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED S-2 17BP.11.R.162 REPLACES BRIDGE NO. 040355 ASHE GENERAL DRAWING SR 1183 AND SR 1182 ON SR 1181 BETWEEN SOUTH FORK NEW RIVER FOR BRIDGE OVER CHECKED BY : DATE : DATE : DRAWN BY : MGC JLA 2/19 SHEET 2 OF 4 { 3'-0" DRILLED PIERS BENT No. 1 CONTROL LINE & { 3'-0" DRILLED PIERS BENT No. 2 CONTROL LINE & { 3'-0" DRILLED PIERS BENT No. 3 CONTROL LINE & 9/19 SPECIFICATIONS. DETERMINE THE NEED FOR CSL TESTING. FOR CSL TESTING, SEE SECTION 411 OF THE STANDARD CSL TUBES ARE REQUIRED AND CSL TESTING MAY BE REQUIRED FOR DRILLED PIERS. THE ENGINEER WILL SID INSPECTIONS. FOR SID INSPECTIONS, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS. SID INSPECTIONS MAY BE REQUIRED FOR DRILLED PIERS. THE ENGINEER WILL DETERMINE THE NEED FOR TESTING, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS. SPT MAY BE REQUIRED FOR DRILLED PIERS. THE ENGINEER WILL DETERMINE THE NEED FOR SPT. FOR SPT STRUCTURE. CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE THE SCOUR CRITICAL ELEVATION FOR BENT No. 3 IS ELEVATION 2,771 FT (LT), 2,774 FT (RT). SCOUR STANDARD SPECIFICATIONS. TIP RESISTANCE AND A PENETRATION OF AT LEAST 5 FT INTO ROCK AS DEFINED BY ARTICLE 411-1 OF THE INSTALL DRILLED PIERS AT BENT 3 TO A TIP ELEVATION NO HIGHER THAN 2,765.0 FT WITH THE REQUIRED FIELD CONDITIONS FOR THE REQUIRED TIP RESISTANCE OF 5 TSF. DRILLED PIERS AT BENT 3 ARE DESIGNED FOR A FACTORED RESISTANCE OF 345 TONS PER PIER. CHECK ENGINEER. CASING BELOW ELEVATION 2,775.0 FT (LT) AND 2,778.1 FT (RT) WITHOUT PRIOR APPROVAL FROM THE PERMANENT STEEL CASINGS ARE REQUIRED FOR DRILLED PIERS AT BENT 3. DO NOT EXTEND PERMANENT STRUCTURE. CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE THE SCOUR CRITICAL ELEVATION FOR BENT No. 2 IS ELEVATION 2,774 FT (LT), 2,780 FT (RT). SCOUR ARTICLE 411-1 OF THE STANDARD SPECIFICATIONS. WITH THE REQUIRED TIP RESISTANCE AND A PENETRATION OF AT LEAST 5 FT INTO ROCK AS DEFINED BY INSTALL DRILLED PIERS AT BENT 2 TO A TIP ELEVATION NO HIGHER THAN 2,770.0 FT (LT) AND 2,775.0 (RT) FIELD CONDITIONS FOR THE REQUIRED TIP RESISTANCE OF 5 TSF. DRILLED PIERS AT BENT 2 ARE DESIGNED FOR A FACTORED RESISTANCE OF 345 TONS PER PIER. CHECK THE CENTERLINE OF PILES. DIMENSIONS LOCATING PILES ARE SHOWN TO ALL PILES ARE HP12x53 STEEL PILES. STA. 16+11.86-L- W.P. 2 STA. 17+02.14-L- W.P. 4 ENGINEER. CASING BELOW ELEVATION 2,777.1 FT (LT) AND 2,783.4 FT (RT) WITHOUT PRIOR APPROVAL FROM THE PERMANENT STEEL CASINGS ARE REQUIRED FOR DRILLED PIERS AT BENT 2. DO NOT EXTEND PERMANENT STRUCTURE. CRITICAL ELEVATIONS ARE USED TO MONITOR POSSIBLE SCOUR PROBLEMS DURING THE LIFE OF THE THE SCOUR CRITICAL ELEVATION FOR BENT No. 1 IS ELEVATION 2,776 FT (LT), 2,780 FT (RT). SCOUR ARTICLE 411-1 OF THE STANDARD SPECIFICATIONS. WITH THE REQUIRED TIP RESISTANCE AND A PENETRATION OF AT LEAST 5 FT INTO ROCK AS DEFINED BY INSTALL DRILLED PIERS AT BENT 1 TO A TIP ELEVATION NO HIGHER THAN 2,772.0 FT (LT) AND 2,775.0 (RT) FIELD CONDITIONS FOR THE REQUIRED TIP RESISTANCE OF 5 TSF. DRILLED PIERS AT BENT 1 ARE DESIGNED FOR A FACTORED RESISTANCE OF 345 TONS PER PIER. CHECK ENGINEER. CASING BELOW ELEVATION 2,778.8 FT (LT) AND 2,782.6 FT (RT) WITHOUT PRIOR APPROVAL FROM THE PERMANENT STEEL CASINGS ARE REQUIRED FOR DRILLED PIERS AT BENT 1. DO NOT EXTEND PERMANENT FOR DRILLED PIERS, SEE SECTION 411 OF THE STANDARD SPECIFICATIONS. CONCRETE OR GROUT IS REQUIRED TO FILL HOLES FOR PILE EXCAVATION AT END BENT 1 AND END BENT 2. TO ELEVATION 2,777 FEET. FOR PILE EXCAVATION, SEE SECTION 450 OF THE STANDARD SPECIFICATIONS. DRILLED-IN PILES ARE REQUIRED FOR END BENT 1 AND END BENT 2. EXCAVATE HOLES AT PILE LOCATIONS DRIVE PILES AT END BENT 1 AND END BENT 2 TO A REQUIRED DRIVING RESISTANCE OF 120 TONS PER PILE. PILES AT END BENT 1 AND END BENT 2 ARE DESIGNED FOR A FACTORED RESISTANCE OF 70 TONS PER PILE. FOR PILES, SEE SECTION 450 OF THE STANDARD SPECIFICATIONS.ENGINEER PROFESSIONAL SEAL NORTH CARO LINA 20125 .gll a hsramcheek,jr.DocuSign Envelope ID: 85F083B1-CA43-4429-86E7-06FEB2AC20B5 1/21/2021 LOCATION SKETCH & DETAIL)(TYP.) (ROADWAY PAY ITEM CLASS I RIP RAP & DETAIL)(TYP.) (ROADWAY PAY ITEM CLASS I RIP RAP BL-5 BL-4 -L- PCC 14+90.12 RIP RAP CLASS II RIP RAP CLASS II PRC 18+03.18-L- -L- (TYP.) 60°00'00" E L LIS R D SR 1181 HARTZOG FORD RD T O SR 1182TO SR 1183NEW RI VERS OUTH F ORKNAD 8 3/ 2 0 1 1 NO.NO.BY:BY:DATE:DATE: REVISIONS SHEET NO. TOTAL SHEETS STATE OF NORTH CAROLINA RALEIGH STATION: COUNTY PROJECT NO. DEPARTMENT OF TRANSPORTATION 1 2 3 4 SHEET OF 16+57.00-L- Placement Scale : PRELIMINARY PLANS DO NOT USE FOR CONSTRUCTION TGS ENGINEERS 804-C N. LAFAYETTE ST SHELBY, NC 28150 PH (704) 476-0003 CORP. LICENSE NO.: C-0275 DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED 17BP.11.R.162 REPLACES BRIDGE NO. 040355 ASHE GENERAL DRAWING SR 1183 AND SR 1182 ON SR 1181 BETWEEN SOUTH FORK NEW RIVER FOR BRIDGE OVER SPECIAL PROVISIONS. SEE UTILITY PLANS & FOR UTILITY INFORMATION, CHECKED BY : DATE : DATE : DRAWN BY : MGC JLA 2/19 S-3 32 SHEET 3 OF 4 { BRIDGE STA. 16+57.00-L- BRIDGE ID PT 15+62.19-L- PC 17+52.19-L- & DETAIL) (TYP.) (ROADWAY PAY ITEM PROPOSED GUARDRAIL BENCH MARK #1 : RAILROAD SPIKE IN 48" OAK, 204' LT. OF STA. 13+39.00-L-, ELEV. = 2,800.83', NAVD 88 3/19 NOTES ASSUMED LIVE LOAD = HL-93 OR ALTERNATE LOADING. FOR EROSION CONTROL MEASURES, SEE EROSION CONTROL PLANS. BRIDGE DESIGN SPECIFICATIONS. THIS BRIDGE HAS BEEN DESIGNED IN ACCORDANCE WITH THE AASHTO LRFD THIS BRIDGE IS LOCATED IN SEISMIC ZONE 1. FOR GROUT FOR STRUCTURES, SEE SPECIAL PROVISIONS. WITH ARTICLE 402-2 OF THE STANDARD SPECIFICATIONS. DEMOLITION PLANS FOR REVIEW AND REMOVE THE BRIDGE IN ACCORDANCE PREVENTS DEBRIS FROM FALLING INTO WATER. THE CONTRACTOR SHALL SUBMIT REMOVAL OF THE EXISTING BRIDGE SHALL BE PERFORMED IN A MANNER THAT ACCESS AT STATION 16+57.00-L-. SPECIAL PROVISIONS FOR CONSTRUCTION, MAINTENANCE AND REMOVAL OF TEMPORARY RIP RAP USED IN THE CAUSEWAY MAY BE PLACED AS RIP RAP SLOPE PROTECTION. SEE AT THE CONTRACTOR'S OPTION, AND UPON REMOVAL OF THE CAUSEWAY, THE CLASS II SEE SPECIAL PROVISIONS. STRUCTURE. FOR CONSTRUCTION, MAINTENANCE AND REMOVAL OF TEMPORARY ACCESS, REMOVE A TEMPORARY ACCESS FOR USE DURING CONSTRUCTION OF THE PROPOSED THE CONTRACTOR WILL BE REQUIRED TO CONSTRUCT, MAINTAIN AND AFTERWARDS SEE SPECIAL PROVISIONS. FOR ASBESTOS ASSESMENT FOR BRIDGE DEMOLITION AND RENOVATION ACTIVITIES, FOR CRANE SAFETY, SEE SPECIAL PROVISIONS. FOR SUBMITTAL OF WORKING DRAWINGS, SEE SPECIAL PROVISIONS. FOR FALSEWORK AND FORMWORK, SEE SPECIAL PROVISIONS.FOR OTHER DESIGN DATA AND GENERAL NOTES, SEE SHEET SN (S-32). STRUCTURE, SEE SPECIAL PROVISIONS. NECESSARY DURING THE LIFE OF THIS PROJECT. FOR REMOVAL OF EXISTING OF THE PROPOSED BRIDGE, THIS LOAD LIMIT MAY BE REDUCED AS FOUND STRUCTURAL INTEGRITY OF THE BRIDGE DETERIORATE DURING CONSTRUCTION THE EXISTING BRIDGE IS PRESENTLY POSTED FOR LOAD LIMIT. SHOULD THE DOWNSTREAM FROM THE SITE OF THE PROPOSED BRIDGE SHALL BE REMOVED. MASS CONCRETE ABUTMENTS AND SOLID CONCRETE PIER BENTS AND LOCATED CLEAR ROADWAY WIDTH OF 11'-1"; AND WITH A SUBSTRUCTURE CONSISTING OF TIMBER FLOOR ON STEEL I-BEAMS WITH A 4" ASPHALT WEARING SURFACE AND (1 @ 30'-10", 2 @ 30'-0", 1 @ 30'-10") WITH A SUPERSTRUCTURE CONSISTING OF A AFTER SERVING AS A TEMPORARY STRUCTURE, THE EXISTING 4 SPAN STRUCTURE STRUCTURE EXCAVATION, SEE SECTION 412 OF THE STANDARD SPECIFICATIONS. WILL BE PAID FOR AT THE CONTRACT LUMP SUM PRICE FOR UNCLASSIFIED AND 30' (RT) AT END BENT 2 AS DIRECTED BY THE ENGINEER. THIS WORK A DISTANCE OF 40' (LT) AND 40' (RT) OF -L- AT END BENT 1 AND 35' (LT) THE MATERIAL SHOWN IN THE CROSS-HATCHED AREA SHALL BE EXCAVATED FOR SCOUR AT BRIDGES". THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH HEC 18, "EVALUATING STRUCTURE AT STATION 16+57.00-L-." SHALL BE INCLUDED IN THE BID PRICE FOR "REMOVAL OF EXISTING PERTAINING TO HANDLING OF MATERIALS CONTAINING LEAD BASED PAINT COMPLIANCE WITH APPLICABLE STATE OR FEDERAL REGULATIONS 107-1 OF THE STANDARD SPECIFICATIONS. ANY COSTS RESULTING FROM CONTAINS LEAD. THE CONTRACTOR'S ATTENTION IS DIRECTED TO ARTICLE INASMUCH AS THE PAINT SYSTEM ON THE EXISTING STRUCTURAL STEEL ACCESS TEMPORARY & DETAIL)(TYP.) (ROADWAY PAY ITEM CLASS I RIP RAP ACCESS TEMPORARY EXISTING STRUCTURE ENGINEER PROFESSIONAL SEAL NORTH CARO LINA 20125 .gll a hsramcheek,jr.DocuSign Envelope ID: 85F083B1-CA43-4429-86E7-06FEB2AC20B5 1/21/2021