Loading...
HomeMy WebLinkAboutWQ0042255_Application (FTSE)_20210209Permit Number WQ0042255 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow Facility Facility Name Wilmington Trade Center Public Force Main Location Address Owner Owner Name Cape Fear Public Utility Authority Central Files: APS _ SWP _ 1 /21 /2021 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Major/Minor Region Minor Wilmington County New Hanover Facility Contact Affiliation Owner Type Government - Municipal Owner Affiliation James R. Flechtner PE 235 Government Center Dr Dates/Events Wilmington NC 28403 Scheduled Orig Issue App Received Draft Initiated Issuance 1 /13/2021 Regulated Activities NORMS & TUNSTALL CONSULTING ENGINEERS P.C. 2602 Iron Gate Drive, Suite 102 Wlihnington, NC 28412 (910) 343-9653 (910) 343-9604 Fax John S. Tunstall, P.E. T. Jason Clark, P.E. January 12, 2021 NC DEQ Division of Water Resources Water Quality Regional Operations Section Wilmington Regional Office 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Gravity Sewer Extension Fast -Track Permit Application (Public) Wilmington Trade Center (Public Force Main Extension) New Hanover County N&T Project No. 19131 Dear Sir or Madam: 1429 Ash -Little Rivet Road Ash, NC 28420 (910) 287-5900 (910) 287-5902 Fax J. Phillip Norris, P.E. Joseph K. Bland, P.E. Thomas J. Scheetz, E.I. iECEIV[-:1 JAN 13 2021 NGDEQ WILMINMON RO Enclosed is one (1) original application form, one (1) copy of the Calculations, one (1) copy of the Sewer Narrative, one (1) Flow Letter from the Cape Fear Public Utility Authority, one (1) 8'/2 x 11 color USGS Topographic Map, one (1) site plan (ledger size) and a $480.00 check for the processing fee. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. - I �. "U aa'-� Jo S. Tunstall, P.E. JST/asn 19131 01-12-21-s-swr-Itr (Public) Enclosures NCBELS License C-3641 SEWER NARRATIVE WILMINGTON TRADE CENTER 4104 Hwy. 421 North Wilmington, North Carolina For SEAMIST PROPERTIES, LLC 3807 Peachtree Avenue, Suite 200 Wilmington, NC 28403 (910) 395-6036 �N h SEAL 4 1985��. S�•NGI`E,. °..... S. TUN..< November 2020 Prepared by: NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C. 2602 Iron Gate Drive, Suite 102 Wilmington, North Carolina 28412 (910)343-9653 (910) 343-9604 (Fax) License # C-3641 N&T Project #19131-1 NARRATIVE SEWER SYSTEM: These private duplex grinder pump stations and forcemain systems are designed to service warehouse / showroom / office buildings. This permit is for the Wilmington Trade Center. There are three (3) separate buildings with three (3) separate duplex private grinder pump stations that will tie in to the existing 6" Public Low Pressure Forcemain that is on the West side of US Hwy. 421. This forcemain belongs to the CFPUA. PS #1:157,500 SF Warehouse & Office Space ADF = 6,950 GPD; PDF = 17,375 GPD PS #2:157,500 SF Warehouse & Office Space ADF = 6,950 GPD; PDF = 17,375 GPD PS #3:110,250 SF Warehouse & Office Space ADF = 4,900 GPD; PDF = 12,250 GPD Each Private Pump Station will consist of a 6-foot diameter wet well, discharge piping, valve vault, and required electrical panel and controls. The pump station reliability of the station is per 15A NCAC 02T .0305 (h)(1)(C). A portable pump power source shall be dedicated to backup of this station. A letter will be provided that the portable source of power is owned or contracted for by the permittee and is compatible with the station. Telemetry is provided at the station with remote notification if a power outage or problem occurs. A high-water audio and visual alarm are provided. The downstream forcemain size is 6". We are having to directional drill under US 421 with a 4" forcemain. We are able to maintain 2 fps in the 4" forcemain. The 6" forcemain is a Low Pressure forcemain designed to accommodate multiple Pump Stations from along the 421 corridor. There will be Private forcemain and Public forcemain in this permit. Private Forcemain Lengths: 3" — 1892 ft 4" — 354 ft Public Forcemain Lengths: 4" — 130 ft 6"-39ft There are multiple conditions that occur for each pump station. Each of these pump stations must be able to maintain 2 fps in the forcemain immediately downstream from the pump station and overcome any Pump Stations that may also be on during operation. PS #1 must be able to maintain 2 fps in the 4" forcemain. With that in mind, each pump station will pump well above their required peak, in the predominant condition. The MDC requires if practical, a minimum of two (2) cycles per hour. Due to the ADF, the duplex pump / wet well requirements and the minimum FM requirements it is not practical to meet the two (2) cycles per hour requirement. This system will be served by the Cape Fear Public Utility Authority. State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: WWA 44" (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Cane Fear Public Utility Authority (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ® Other 3. Signature authority's name: Jeff Theberge, P.E. per 15A NCAC 02T .0106(b) Title: Engineering Manager 4. Applicant's mailing address: 235 Government Center Drive City: Wilmington State: NC Zip: 28403- 5. Applicant's contact information: Phone number: 910) 332-6673 Email Address: Jeff.Thebergc@cfpua.org IIII�;illffs[�lIaICIEll 10EIVV W►A 1. Project name: Wilmington Trade Center (Public Force Main Extension) 2. Application/Project status: ❑ Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: If new construction but part of a master plan, provide the existing permit number: W000 3. County where project is located: New Hanover 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.304331 ° Longitude:-77.97966' 5. Parcel ID (if applicable): R02400-001-041-000 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: John S. Tunstall, P.E. License Number: 19851 Firm: Norris & Tunstall Consulting Engineers, P.C. Mailing address: 2602 Iron Gate Drive, Suite 102 City: Wilmington State: NC Zip: 28412- Phone number: (910) 343-9653 Email Address: itunstall@ntengineers.com & anorris@ntengineers.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: James A. Loughlin (Northside W WTP)_ Permit Number: NC 0023965 Owner Name: Cane Fear Public Utility Authority V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00039283 System Wide Collection System Permit Number(s) (if applicable): WQCS Owner Name(s): Cape Fear Public Utility Authority FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS I. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ®No ❑N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ❑N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: I ICA) been attached? ❑ Yes ❑No ❑N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities El Swimming Pool /Clubhouse El Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) S. Nature of wastewater : 100 % Domestic/Commercial _% Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) �•Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(I)? [:]Yes ❑ No ➢ If yes, provide a copy of flow reduction anoroval letter 7. Summarize wastewater generated by project: Establishment Type (see 211.0114(D) Daily Design Flow 6,b No. of Units Flow gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GAD ' Tot, 0 GPD a See 15A NCAC 02T 0114(b)(d) Il and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design now rates for establishments not identified [in table 15A NCAC 02T.01 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 13A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If pennitted flow is zero, indicate why: ® Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) -02'1'.0305 & MDC (Gravity Scwersl: I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material D Section II & Ill of the MDC for Permitting of Gravity Sewers contains infonnation related to design criteria ➢ Section Ill contains information related to minimum slopes for gravity sewer(s) D Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vlll. PUMP STATION DESIGN CRITERIA (If Applicable)-02T.0305 & MDC (Puma Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station mmmber or name: — 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): — gallons per minute at _ feet total dynamic head (TDFI) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4" 130' PVC 6" 39' PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): �—M( W ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day D Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ 1 f the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeftames, shall be provided in the case of a multiple station power outage. FORM: PTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B.0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in 15A NCAC� 2T 0305(tl & f al ➢ 15A NCAC 02T.0305 contains minimum separations that shall be provided for sewers stems: ® Yes [-]No Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet "*Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grado vertical 36 inches 15A NCAC 0210305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpa&e ➢ If noncompliance with 02T.0305(f) or (0. see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No Y See the Division's draft separation requirements for situations where separation cannot be meet Y No variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B 0200? ® Yes [:]No This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? ® Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0I05(0(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonnwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No Y If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the perm ittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of PumR Stations and Force Mains (latest version), and the Gravity Sewer Minimum t version as applicable? Dyes No Ste 15P,60 If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review, Approval of the request is required prior to submittal of the Fast Track Application and supporline documents 2. Professional Engineer's Certification: that this application for Engineer's name from Application Item 111.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215,6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0106(b): that this application for & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143.215,6A and 143-215.68, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: 04,4w, —Izz,�"q2 Date: 1/7/2021 -�uLt �pu� o e,1cl iinte.reC remmb axe. m �'r .L, q Wftb4 ut e�nneci'on yreemafn PS h1UJ-bo✓ a d ply �umf stuh'un, �tn-�ema.in. FORM: FTA 04-16 Page 5 of 5