Loading...
HomeMy WebLinkAboutWI0700195_Staff Report_20210208North Carolina Department of Environment and Natural Resources Division of Water Quality — Aquifer Protection Section INJECTION FACILITY INSPECTION REPORT PERMIT NO. WI0700195 DATE OF INSPECTION: 2/8/21 INSPECTOR: R. Sipe NAME OF PERMITTEE(S) Thomas & Melinda Kay Amsler MAILING ADDRESS OF PERMITTEE 4510 Moncks Court, New Bern, NC 28562 PHYSICAL ADDRESS OF SITE (if different than above) Same as above PERSON MET WITH ON -SITE Melinda Kay Amsler; TELE NO. (252)288-1275 WELL(S) STATUS: XExisting and operating Class V Well Existing well proposed to be converted to Class V well Proposed/not constructed LAT/LONG OF WELL(S) 35.0861N, 77.09W (Inj. Well) Appx. distance of well to property boundaries: _10 feet (Inj. Well) Appx. distance of well from foundation of house/structure: _32 feet (Inj. Well) Appx. distance of well from septic tank/field (if present): _N/A Appx. distance of well to other well(s) (if present) Appx. distance to other sources of pollution: _None 125 feet to supply well Flooding Potential of Site: high moderate Xlow Comments: Both inj., and supply wells appear to be in adequate structural condition; however, at the time of the inspection water was coming out of the pressure relief valve of the injection well. The permittee was notified and stated she would contact her contractor about performing maintenance on the well. Injection Facility Insp. Report (Rev. Sept 2009) Page I of 4 Pages See Attached Map DRAW SKETCH OF SITE ABOVE (Show property boundaries, buildings, other wells, septic tanks/drain fields, other potential pollution sources, roads, approximate scale, and NORTH arrow) GW-1 well records submitted with previous Inspection Report. Draw Schematic of well above showing TD, casing depth, grout, etc. Injection Facility Insp. Report (Rev. Sept 2009) Page 2 of 4 Pages Well Construction Information Date Constructed: 12/22/2010 Well Contracting Company: _Applied Resource Management, P.C. Well Driller Name: Jamie Canter NC Well Cert. No.: 3253-A Address:_257 Transfer Station Rd., Hampstead, NC 28443 Telephone No.: _(910)270-2919 ; Cell No.: Email Address: Proposed Depth of Well(s): _N/A Total Depth: _80 feet Total Depth of Source Well, if present:_68 feet Casing: Depth: 60 feet; Diameter: 4 inches_; Type (gay. steel, PVC, etc.): _PVC Stick Up: _1.5 feet Grout Depth: 25 feet; Type (cement, bentonite, etc.):_Bentonite ; Placement (pumping, press. etc.): _Tremmie Well ID Plate Present (Y or N): Y ; Heat Pump ID plate present (Y or N): N Influent spigot (Y or N): Y Effluent spigot (Y or N): Y Well Sampled? (Y or N): N ; If Yes, Lab Sample ID numbers: N/A Static Water Level: _3 feet (at installation) Injection Information (if applicable): Injection Rate: GPM Injection Pressure: PSI Injection Volume: GPD Temperature- Summer: F° Temperature- Winter: F° Comments/Notes: See comments above. ft Injection Facility Insp. Report (Rev. Sept 2009) Page 3 of 4 Pages Injection Facility Insp. Report (Rev. Sept 2009) Page 4 of 4 Pages