HomeMy WebLinkAboutNC0032867_NOV2021PC0066_20210126ROY COOPER Goyffrvr MICHAEL S. RECAN Sffmmry $. DANIEL SMITH Dbw w NORTH CARCLINA Enlroronmerkwl Quality 26 January 2021 CERTIFIED MAIL # 7018 0360 0002 2099 7248 RETURN RECEIPT REQUESTED Laeeq Khan, President Malik's International, Inc. 3425 Carnoustie Drive Chambersburg, PA 17202 Subject: Notice of Continuing Violation and Recommendation for Enforcement NOV-2021-PC-0066 Kings Mountain Travel Plaza WWTP NPDES Permit NCO032867 Cleveland County Dear Mr. Khan: Enclosed please find the Compliance Evaluation Inspection report for the inspection conducted on January 19, 2020, by Ori Tuvia. The cooperation of your system operators Daniel Dougherty and Ron Haynes during the site visit was much appreciated. Previous inspection dated January 28, 2020, resulted in the issuance of a Notice of Continuing Violation and Recommendation for Enforcement (NOV-2020-PC-0073 dated February 5, 2020). The following violations noted during the previous inspection have not been resolved and require immediate attention: In accordance with Part II, Section C.2 of the subject permit, proper Operation and Maintenance (O&M) of the WWTP is required. The following treatment units/equipment/components are listed in the permit and were found to be non -operational at the time of the inspection and need to be addressed: • Two septic tanks were not operational, leaking, and not piped nor valved. The two septic tanks must be properly sealed to avoid leaching wastewater to the ground and properly piped so they can be used as indicated in the permit. • The facility has two (2) permitted aeration basins: Only one of the aeration basins was operational. The second aeration basin had no blowers and was being used as a sludge storage tank. Additionally, the aeration basin grating was insufficient. Grating should be properly installed to ensure the safety of the ORC/operators and DWR staff (image 2). Elm State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations Mooresville Regional Office 1 610 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115 704 663 1699 • The ORC indicated that the aerobic digester and a holding tank may be leaking. The tanks should be tested for leaks and, if found to be leaking, they should be immediately repaired and properly maintained. • At the time of the inspection, the flow meter chart recorder was not operational. At the time of the inspection, the flow meter was not operational. The flow meter censor was under water and not operational (see image 1). The flow meter is a permitted treatment component listed in the permit. An additional issue documented at the time of the inspection was the Outfall 002 oil and grease separator receives higher flows due to poor drainage of the gas pumping area. Improved maintenance of the drainage areas will increase the efficiency of the oil water separator. A Notice of Violation and Notice of Recommendation for Enforcement, pursuant to G.S. 143-215.6A, may result in a civil penalty of not more than twenty-five thousand dollars ($25,000.00) per day, per violation and may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of any permit issued pursuant to G.S. 143-215.1. You are requested to respond to this Notice in writing within ten (10) days of receipt indicating your Plan of Action to ensure future compliance. The report should be self-explanatory; however, should you have any questions concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at ori.tuviagncdenr.gov. Sincerely, DocuSigned by: A14CC681 AF27425... W. Corey Basinger Regional Supervisor Mooresville Regional Office Division of Water Resources Attachment: CEI report Cc: Ron Haynes (E-copy) MRO Files (Laserfiche)