Loading...
HomeMy WebLinkAbout20181344 Ver 2_Cross Sections- 20210204_20210208Q w w 299+00.00 20 20 EL 14.0 10 10 10 EL7.0 e\✓r\� 40, 0 0 -10 -10 -20 -20 T 3 4 5 6 303+00.00 307+00.00 311+00.00 EL 14.0 10' i 10 20'1 0 / -10 -20 -300 -200 -100 0 100 400 -300 -200 -100 0 1 DISTANCE (FEET) DISTANCE (FEET) 298+00.00 302+00.00 zu zo EL 14.0 10' 10 10 EL 7.0 20'1 0 0 /// / -10-- - - - - -10 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 297+00.00 FA"�'M 400 -300 -200 -100 0 10( DISTANCE (FEET) 296+25.00 EL 7.0 y \ / 0 0 10 ` -1, LU LU EL 14.0 10' 10 u) 10 e7.0\�- Z�1 0 0 10--- - - _ -10 -20 -20 T T 400 -300 -200 -100 0 10( DISTANCE (FEET) 301+00.00 EL 14.0 10' u` 1 EL 7.0 f 400 -300 -200 -100 0 101 DISTANCE (FEET) 300+00.00 EL 14.0 10' zA-- - m EL 7.0 0 -,o 20 !E! IT, IF, EL 14.0 10' EL 7.0 \\^� 400 -300 -200 -100 0 10( DISTANCE (FEET) 306+00.00 EL 14.0 10' EL 7.0 400 -300 -200 -100 0 10( DISTANCE (FEET) 305+00.00 EL 14.0 10' i EL 7.0 In 400 -300 -200 -100 0 10( DISTANCE (FEET) 304+00.00 EL 14.0 10' EL 7.0 20'1 20 EL 14.0 10' �\ 10 EL 7.0 0 -10 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 310+00.00 20 EL 14.0 10' 10 EL 7.0 r 0 -,o -2o 400 -300 -200 -100 0 100 DISTANCE (FEET) 309+00.00 20 EL 14.0 10' 10 EL 7.0 0 -10 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 308+00.00 LEGEND 20 EXISTING GRADE EL 14.0 10 PROPOSED RENOURISHMENT m EL 7.0 > \ LIMITS OF FILL 2. 0 10' 0' 10' 20' VERTICAL SCALE: 1 "=10' 10 100 0' 100' 200' HORIZONTAL SCALE: 1 "=100' -2 o 6 ffi S o � N D N O N O N cn Z C7 0 W LL Q0 �cc VO in a w F (n F Q W O N W 2 = 0 in rn U o � 2 O z w Q ¢ $ 0 N B � n 0 \ - o 0 a N O s a£ N ,z4 y Q 1 U O oj. o ¢$ r o w x � c O L U C K o W "7S a _ ` `AM K p `O a E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) 1 -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 00 ISSUED FOR B I D DISTANCE (FEET) APRIL 2020 NOT TO BE USED FOR CONSTRUCTION 5 6 w w 315+00.00 20 20 EL 14.0 10' 10 10 EL 7.0 0 0 -10 -1, -20 -21 400 -300 -200 -100 0 10( DISTANCE (FEET) 314+00.00 2U LU EL 14.0 10' 10 10 EL 7.0 0 0 -10 -10 -20 1-20 400 -300 -200 -100 0 10( DISTANCE (FEET) 313+00.00 20 20 EL 14.0 10' 0 10 EL 7.0 J 0 0 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 312+00.00 2U LU EL 14.0 10' 10 0 EL 7.0 \ 0 0 -10 -10 -20 -20 T T T 3 4 5 6 319+00.00 323+00.00 327+00.00 EL 14.0 10' 1 EL 7.0 J�� 2 � 400 -300 -200 -100 0 101 DISTANCE (FEET) 318+00.00 EL 14.0 10' 10 EL 7.0 \ 20n 0 -20 400 -300 -200 -100 0 101 DISTANCE (FEET) 317+00.00 EL 14.0 10' e7.O�- 1 400 -300 -200 -100 0 101 DISTANCE (FEET) 316+00.00 IF! EL 14.0 10' i 400 -300 -200 -100 0 10( DISTANCE (FEET) 322+00.00 EL 14.0 10' EL 7.0 \ 400 -300 -200 -100 0 100 DISTANCE (FEET) 321+00.00 20 20 10 10 w Q H W 0 0 0 F w 0 W -10 -20 -20 EL 14.0 10' 10 EL 7.0 _ 0 -m -20 Ir EL 14.0 10' EL 7.0 \ \\ 2' 10 10 m zz w 0 LL 0 Z O F w -10 w -10 20 20 10 10 m Q H W 0 LL 0 0 w -10 W -10 -20 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 320+00.00 EL 14.0 10' e7.0, 20 EL 140 1 AL 10 EL 7.0 v 0 -10 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 326+00.00 20 EL 14.0 10' ,o e7.0\ -m 20 400 -300 -200 -100 0 100 DISTANCE (FEET) 325+00.00 20 EL 14.0 10' i 10 EL 7.0 2. 0 -10 -2o 400 -300 -200 -100 0 100 DISTANCE (FEET) 324+00.00 LEGEND 20 EXISTING GRADE EL 14.0 10' PROPOSED RENOURISHMENT 10EL 7.0 a \_ �\ LIMITS OF FILL 0 10' 0' 10' 20' - - - VERTICAL SCALE: 1"=10' 10 100 0' 100' 200' HORIZONTAL SCALE: 1 "=100' -2 N D N C, N 0 N cn Z o7 0 w LL 2 ¢O �cc VO 1n d w N -F (nF Q w 02 N w 2 ox in cn cc U o � 2 O z w 2 Q 0 e; 0 N B p 0 Y a U O Bi U' ai � E LLO g � � wl z wl 5 N IZN y Q i U O o�� z ¢$ r o w x a O L U C K o W 0 a _ � `p K `0 a E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 ISSUED FOR B I D DISTANCE (FEET) APRIL 2020 NOT TO BE USED FOR CONSTRUCTION 5 6 w w 1 331+00.00 20 20 EL 14.1 10' i 10 10 EL 7.0 ` 0 0 10'1 -10 -,( -20 -2( 300 -300 -200 -100 0 10( DISTANCE (FEET) 330+00.00 2° LU EL 14.0 10' i 10 ,\ 10 r \ 0 0 -10 -10 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 329+00.00 400 -300 -200 -100 0 10( DISTANCE (FEET) 328+00.00 2° 2° EL 14.0 10' 10 \I 10 �7O \v \ 0 0 -10 -,0 -20 1 -20 T T it 3 4 5 6 335+00.00 339+00.00 343+00.00 EL 14.3 10' 1 2 f 400 -300 -200 -100 0 10( DISTANCE (FEET) 334+00.00 EL 14.2 10' 10 EL 7.0 r\ 0 70'1 - -10 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 333+00.00 EL 142 10' AA 1 f zo^ 400 -300 -200 -100 0 10( DISTANCE (FEET) 332+00.00 EL 14.1 10' � m EL 7.0 \v- 0 20'1 10 -zo IF! T EL 14.5 10' 2' 400 -300 -200 -100 0 10( DISTANCE (FEET) 338+00.00 EL 144 1 EL 7.0 \lam 2' 400 -300 -200 -100 0 10( DISTANCE (FEET) 337+00.00 EL 14.4 10' EL 7.0 400 -300 -200 -100 0 10( DISTANCE (FEET) 336+00.00 EL 14.3 10' 20 EL14.5 1° 7 10 EL 7.0 0 20'1 ` -10 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 342+00.00 20 EL14.5 1° ' 10 0 10'1 -m -zo 400 -300 -200 -100 0 100 DISTANCE (FEET) 341+00.00 20 EL14.5 1° 10 �7.0\ 0 qo^ -10 -20 - 0O -300 -200 -100 0 100 DISTANCE (FEET) 340+00.00 LEGEND 20 EXISTING GRADE ELEL419 51 ° PROPOSED M-- RENOURISHMENT 10EL 7.0 \ LIMITS OF FILL 1 2, y 0 ao, 10' 0' 10' 20' VERTICAL SCALE: 1"=10' -10 100 0' 100' 200' HORIZONTAL SCALE: 1 "=100' -z N D N C, N 0 N Z C7 0 W �LL a0 �cc VO (A LL W M - F (N F a cn Ill O N w 2 = cc c 1n U o � 2 O z w Q 2 0 e; 0 N B p 0 rc a U O ai � E LLO g � � wl z wl 5 N IZN y Q inn U oig z ¢$ r o w x a O L U C K o w 0 a _ 2 w AM p `0 a E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 100LISSUED FOR B I D DISTANCE (FEET) APRIL 2020 O BE USED FOR CONSTRUCTION 5 6 w w 1 347+00.00 20 20 EL 14.5 10' 10 10 EL 7.0 0 0 -10 -1, -20 -21 400 -300 -200 -100 0 10( DISTANCE (FEET) 346+00.00 2U LU EL 14.5 10' 10 0 EL 7.0 ^ 0 0 qo^ -10- -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 345+00.00 400 -300 -200 -100 0 10( DISTANCE (FEET) 344+00.00 2U LU EL 14.5 10' 10 10 EL 7.0 0 0 y01 - -10 -10 -20 -20 T T T 3 4 5 6 351+00.00 355+00.00 359+00.00 EL 14.5 10' EL 7.0 400 -300 -200 -100 0 10( DISTANCE (FEET) 350+00.00 EL 14.5 10' 10 0 10 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 349+00.00 EL 14.5 10' 400 -300 -200 -100 0 10( DISTANCE (FEET) 348+00.00 EL 14.5 10' 10 EL 7.0 2 0 -20 IF, T ELE1419 510' i EL 7.0 L� 400 -300 -200 -100 0 10( DISTANCE (FEET) 354+00.00 ELE1419 510' EL 7.0 � 400 -300 -200 -100 0 10( DISTANCE (FEET) 353+00.00 ELE1419 510' �7.0' \ 400 -300 -200 -100 0 10( DISTANCE (FEET) 352+00.00 EL 14.5 10' EL 7.0 10 10 m zz w 0 LL 0 z O F w w -10 -10 20 EL14.5 1 10 EL 7.0 \ v ° -10 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 358+00.00 20 EL14.5 1 10 EL 7.0 v. o 10 z0 400 -300 -200 -100 0 100 DISTANCE (FEET) 357+00.00 20 EL14.5 1 i 10 �ELTO'r 2 0 -10 -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 356+00.00 LEGEND 20 EXISTING GRADE EL 14.5 1°' PROPOSED RENOURISHMENT 10EL 7.0 > � LIMITS OF FILL 0 10, 0' 10, 20' VERTICAL SCALE: 1'.10, -10 100 0' 100, 200' HORIZONTAL SCALE: 1 "=100' -z N D N O N O N cn Z C7 0 W �LL ¢O �cc 00 (n a w v -F (nF Q W 02 N W 2 0 (n x (n cc U o � 2 O z w 2 Q 0 e; 0 N B p 0 - o o rc a U O U' E g � 0 � w. p 5 N W-4 y Q i U U oj. o ¢$ r o w x a O L U C K o W 0An a _ � `p K `o a E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 1. ISSUED FOR B I D DISTANCE (FEET) APRIL 2020 NOT TO BE USED FOR CONSTRUCTION 5 6 1 2 3 363+00.00 367+00.00 20 10 w E cc Z I- W Wi 0 Z O F w w -10 -20 w w EL 14.5 1i0'� 20 20 EL 14.5 10' 0 10 1 EL 7.0 EL Z H W LL U Z O F w -- w 10 -10 - - 20 -20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 DISTANCE (FEET) DISTANCE (FEET) 362+00.00 366+00.00 2U LU EL 14.5 10' 10 10 EL 7.0 �f 0 2 0 -10 -10 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 361+00.00 y� 1 \ L� \Y 0 400 -300 -200 -100 0 10( DISTANCE (FEET) 360+00.00 2U LU EL 14.5 10' 10 m EL 7.0 0 0 -10 -10 -20 -20 If, T 9 20 20 10 10 LD 11 EL 14.5 10' "1 10 EL 7.0 1, 0 10 -20 400 -300 -200 -100 0 101 DISTANCE (FEET) 365+00.00 EL 14.5 10' i / 1 EL 7.0 2, f 400 -300 -200 -100 0 101 DISTANCE (FEET) 364+00.00 EL 14.5 10' )1 m EL 7.0 2. 0 - -10 20 IF, Ir 5 6 371+00.00 375+00.00 EL 14.5 10' 1 EL 7.0 400 -300 -200 -100 0 100 DISTANCE (FEET) 370+00.00 EL 14.5 10' )1 \J 2' 400 -300 -200 -100 0 100 DISTANCE (FEET) 369+00.00 EL 14.5 10' n 2' 400 -300 -200 -100 0 10( DISTANCE (FEET) 368+00.00 EL 14.5 10' rl 2' 20 EL 14.5 10' II 10 EL 7.0 20. 0 -10 -20 400 -300 -200 -100 0 1. DISTANCE (FEET) 374+00.00 20 EL 14.5 10' n 10 1 EL 7.0 1 ZO 0 -m 1-20 400 -300 -200 -100 0 100 DISTANCE (FEET) 373+00.00 20 EL 14.5 10' 10 EL 7.0 \ 0 10 20 400 -300 -200 -100 0 100 DISTANCE (FEET) 372+00.00 LEGEND 20 EXISTING GRADE EL 14.5 10 PROPOSED RENOURISHMENT 10 EL 7.0 > 1 LIMITS OF FILL �l 2 0 10, 0' 10, 20' _ VERTICAL SCALE: 1"=10' -10 100 0' 100, 200' HORIZONTAL SCALE: 1 "=100' -2 N D 0 O N 0 N Z o7 0 w 2LL ¢O O (n a VLo w -F (nF a w O N w 2 = cc c (n U o � 2 O z w Q 2 0 e; 0 N B p 0 - o o Y a U O U' ai � E LLO g � � wl p wl 5 N IZN y Q 1 U', O 10 o�& z ¢$ r o w x 1 a O L U C K o w 0 a _ `p w `0 a E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 100LTNOT ISSUED FOR B I D DISTANCE (FEET) APRIL 2020 O BE USED FOR CONSTRUCTION 5 6 379+00.19 20 EL 14.5 1 ' i 10 1 EL 7.0 0 -10- -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 378+00.00 10 10 2U LU EL 14.5 10' 10 ' )1\ 10 EL 7.0 0 4 0 -10 -10 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 377+00.00 400 -300 -200 -100 0 100 DISTANCE (FEET) 376+00.00 2U LU EL 14.5 10' fl 10 10 EL 7.0 L 0 0 20' -10 - -10 -20 -20 T T T 3 4 5 6 383+00.00 387+00.00 391+00.00 EL 14.5 10' � 11 EL 7.0 1\ 10'1 f 400 -300 -200 -100 0 10( DISTANCE (FEET) 382+00.00 EL 14.5 10' )1 10 1 EL 7.0 1 qo^ 0 -10 -zo 400 -300 -200 -100 0 10( DISTANCE (FEET) 381+00.00 EL 14.5 10' � 1 EL 7.0 1 / 20'1 f 400 -300 -200 -100 0 10( DISTANCE (FEET) 380+00.00 EL 14.5 10' 10 q 0 -20 IF! Ir EL 14.5 10' i EL 7.0 400 -300 -200 -100 0 10( DISTANCE (FEET) 386+00.00 EL 14.5 10' EL 7.0 400 -300 -200 -100 0 10( DISTANCE (FEET) 385+00.00 EL 14.5 10' EL 7.0 1 400 -300 -200 -100 0 10( DISTANCE (FEET) 384+00.00 EL 14.5 10' EL 7.0 10 10 m zz W 0 LL 0 Z O F w -10 W -10 10 10 m z w 0 LL 0 z O Q w -10 W -10 10 10 m z H W 0 LL 0 0 w -10 W -10 20 EL 14.4 1 0' Au` 10 EL 7.0 10'1 0 -10 -zo 400 -300 -200 -100 0 100 DISTANCE (FEET) 390+00.00 20 EL 14.5 10' 1 10 EL 7.0 1 � qo^ 0 - ' -10 20 400 -300 -200 -100 0 100 DISTANCE (FEET) 389+00.00 20 EL 14.5 10' 10 EL 7.0 1 0 -1 o 10 400 -300 -200 -100 0 100 DISTANCE (FEET) 388+00.00 LEGEND 20 EXISTING GRADE EL 14.5 10 PROPOSED RENOURISHMENT m EL 7.0 > 1 LIMITS OF FILL 0 10' 0' 10' 20' VERTICAL SCALE: 1"=10' -10 100 0' 100' 200' HORIZONTAL SCALE: 1 "=100' 2 N D N O N 0 N cn Z C7 0 W 2LL ¢O cc in a VO w -F (nF Q W O N w 2 = 0 , fn U o � 2 O z w Q 2 0 e; 0 N B p w. 0 rc a U Bi U' E o g � � W, p 5 N w y Q 2�� o o ¢$ r o w x a O L U C K o w 0 a _ `p w x `o E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 1. ISSUED FOR B I D DISTANCE (FEET) APRIL 2020 NOT TO BE USED FOR CONSTRUCTION 5 6 w w w w 395+00.00 20 20 EL 14.0 10' 10 10 EL 7.0 yo^ 0 0 -10 -,0 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 394+00.00 2U LU EL 14.1 10' 10 �\ 10 0EL7.0 \/L 20'1 0 0 -10-- - -10 -20 -20 i 400 -300 -200 -100 0 10( DISTANCE (FEET) 393+00.00 400 -300 -200 -100 0 10( DISTANCE (FEET) 392+00.00 2U LU EL 14.3 10' ,o \ m EL 7.0 y0 ` 0 0 -10 - - - ' -,o -20 -20 T 3 4 5 6 399+00.00 403+00.00 407+00.00 EL 13.6 10' 1 EL 7.0 y0^ f 400 -300 -200 -100 0 100 DISTANCE (FEET) 398+00.00 20 10 T T EL 13.7 10' u` EL 7.0 400 -300 -200 -100 0 100 DISTANCE (FEET) 397+00.00 20 20 10 10 ro Q w 0 0 z O w ,o W -10 z0 20 EL 13.8 10' EL 7.0 \l~ y0 �` f 400 -300 -200 -100 0 101 DISTANCE (FEET) 396+00.00 EL 13.9 10' 10 EL 7.0 y0'1 0 ,0 -20 T EL 13.5 10' EL 7.0 y0j4 400 -300 -200 -100 0 10( DISTANCE (FEET) 402+00.00 EL 13.5 10' �1 EL 7.0 V J y0;1 i 400 -300 -200 -100 0 10( DISTANCE (FEET) 401+00.00 EL 13.5 10' i \ EL 7.0 \` 400 -300 -200 -100 0 10( DISTANCE (FEET) 400+00.00 EL 13.5 10' A1 EL 7.0 y0 �` 20 EL 13.5 10' 10 EL 7.0 � 0 -z0 400 -300 -200 -100 0 100 DISTANCE (FEET) 406+00.00 20 EL 13.5 10' o e7.O y0� 0 -m -20 400 -300 -200 -100 0 100 DISTANCE (FEET) 405+00.00 20 EL 13.5 10' r 10 EL 7.0 y0� 0 i -10 z0 400 -300 -200 -100 0 100 DISTANCE (FEET) 404+00.00 LEGEND 20 EXISTING GRADE EL 13.5 10 PROPOSED RENOURISHMENT 10 \ EL 7.0 LIMITS OF FILL \ V i 0 10' 0' 10' 20' VERTICAL SCALE: 1"=10' - - -10 100 0' 100' 200' HORIZONTAL SCALE: 1 "=100' 2 N D N C, N O N cn Z C7 0 W �LL ¢O O oC (n a U w n -F (nF a W O N w 2 = cc c (n U o � 2 O � z � w Q e; 0 N B p 0 - o 0 Y a U O U' ai � E LLO g � � wl p wl 5 N IZN y Q i U'l O z ¢$ r o w x a O L U C K o w 0 a _ `p w `o a E 4 SEAL a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) -300 -200 -100 0 1 DISTANCE (FEET) 4 400 -300 -200 -100 0 100 I S SUE D F O R B I D DISTANCE (FEET) APRIL 2020 NOT TO BE USED FOR CONSTRUCTION 5 6 411+00.00 20 20 EL 13.5 10' 10 10 0EL7.0 \v 0 0'1 0 -10 - / / -,( -20 -2( 400 -300 -200 -100 0 10( DISTANCE (FEET) 410+00.00 2U LU EL 13.5 10' 10 10 EL 7.0 0 0 -10 - -,0 -20 1 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 409+00.00 20 20 EL 13.5 10' m m EL 7.0 \ 0 V 0 -10 _ -,0 -20 -20 400 -300 -200 -100 0 10( DISTANCE (FEET) 408+00.00 2U LU EL 13.5 10' 10 10 EL 7.0 20' 0 0 -20 -20 T T it 3 4 5 6 415+00.00 419+00.00 423+00.00 EL 13.5 10' A/ 1 e7.O` f 400 -300 -200 -100 0 10( DISTANCE (FEET) 414+00.00 EL 13.5 10' 1 10 EL 7.0 �r 201 0 -10 -2o 400 -300 -200 -100 0 10( DISTANCE (FEET) 413+00.00 EL 13.5 10' r 1 1 20'1 f 400 -300 -200 -100 0 10( DISTANCE (FEET) 412+00.00 EL 13.5 10' 10 EL 7.0 0 10 -20 IF! z w 0 z O w -m T 20 10 0 -10 -20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 DISTANCE (FEET) DISTANCE (FEET) 418+00.00 422+00.00 20 20 10 10 m z w 0 LL 0 z O w -,o -10 -20 -20 20 10 0 -10 -20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 DISTANCE (FEET) DISTANCE (FEET) 417+00.00 421+00.00 26 10 10 m Z W 0 LL 0 0 w -10 w -10- 20 20 20 20 10 10 yr>�r 10 0 10 -20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 DISTANCE (FEET) DISTANCE (FEET) 416+00.00 420+00.00 LEGEND 10 10 W z Z W 0 LL 0 Z O w -10 w -10 -20 -20 EL 13.6 10' EL 7.0 EL13.5 I( '\ EL 7.0 SJ q0� EXISTING GRADE PROPOSED RENOURISHMENT 0 LIMITS OF FILL 0 10' 0' 10' 20' VERTICAL SCALE: 1"=10' -10 100' 0' 100' 200' HORIZONTAL SCALE: 1 "=100' -2 N D N C, N 0 N cn Z C7 0 W 2LL ¢O O in a Vco w -F (nF Q W O N w 2 = 0 in cn U o � 2 O z w Q cc e; 0 N B p 0 rc a U O U' ai � E LLO g � � wl z wl 5 N IZN y Q 1U� O oig z ¢$ r o w x a O L U C K o W _ 2 w p `o a E 4 KE L a N -300 -200 -100 0 DISTANCE (FEET) y -300 -200 -100 0 DISTANCE (FEET) 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 1 5 5 U t U r U K L31 U DISTANCE (FEET) DISTANCE (FEET) APRIL 2020 NOT TO BE USED FOR CONSTRUCTION 4 5 6 1 2 3 4 5 6 ict;j, �p,K 20 427+00.00 20 20 431+00.00 20 20 435+00.00 20 20 439+00.00 20 EL 14.2 10' EL 14.5 10' EL 14.5 10 EL 14.5 10' " 1�1„V (1( u` 1 A � / ' / 10 EL 7.0 ' 10 L .-. 10 EL 7.0 1 �� 10 ,-. 10 \ / EL 7.0 10 .-. 10 ` EL 7.0 10 E¢ a Q a E z W LL 0 2p, 0 z W LL 0 2p'1 z W 0 0 ,Lp.1 0 z LL 0 0 Z Z Z Z O O O O w -10 -" -10 w -10 w _ -10 -10 -10 w -10 -m i -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 -20 100 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 20 426+00.00 20 20 430+00.00 20 20 434+00.00 20 20 438+00.00 20 D EL 14.1 10' EL14.5 10 EL14.5 10 EL14.5 10' N D N u� )� A11 ���� A \ / N 10 EL 7.0 10 `^ 10 EL 7.0 v \ 10 10 EL 7.0 \ 10 10 EL 7.0 �"/ 10 C N F- 0 Illz Cn Z f 20'1 Z H p1 2' Z H Z H 10:1 Z-3 a 0 O LL F-O w w w p1 w J cc U LL 0 o LL 0 0 0 0 LL o 0 U) a Lu 0 O O O O Q Z N F Cn Ill l(N O w w w w �_ O cc w w w cn U o -10_ -10- -10 -10 -m ¢ 2 - O z w e -20 -20 -20 -20 -20 -20 -20 -20 �+ 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 C 5" a C 425+00.00 429+00.00 433+00.00 437+00.00 20 20 20 20 20 20 20 20 h O EL 14.0 10' EL 14.4 10' EL 14.5 10 EL 14.5 10' W ,/^1 a 2 Y (9 10 10 10 _ 70 10--10 70 10 O EL 7.0 c^� O EL 7.0 zZ z z z W M1p 1 W y0N W 2p', Z W 1p1 Q LL 0 _ 0 LL 0 0 0 0 LL 0 0 e 0 0 0 0 N W W //- W W i N W -10 -10 W -10 - ' W -- -- -10 -10 -10 W -10--'-10 4 0 B m m B U 20 20 20 20-2.----400 20 20 20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 -300 -200 -100 0 100 400 -300 -200 -100 0 100 N DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) LEGEND F 424+00.00 428+00.00 432+00.00 436+00.00 20 20 20 20 20 20 20 20 EXISTING GRADE N EL 13.9 10' EL 14.3 10' EL 14.5 10 EL 14.5 10' PROPOSED N A(1 m �\ RENOURISHMENT AM N Z 10 10 10 ^ 0 10 10 10 10 0 a a � LIMITS OF FILL � EL 7.0 `J /~ EL 7.0 �� EL 7.0 \/J U Z > Z > Z > Z h W 2p 1 W M1p1 W 20 W 70.1 h � U LL 0 0 LL 0 0 0 0 LL 0 0 O F O O O 10' 0' 10' 20' A w w w i w VERTICAL SCALE: 1"=10' A -10 -10---- 10 -' � -m -10 - -10 -10 -10 100' 0' 100' 200. U SEAL �I h HORIZONTAL SCALE: 1 "=100' � Sheet N 20 20 20 20 20 20 20 2 ISSUED FOR BID Reference No. o 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 APRIL 2020 C_309 NOT TO BE USED FOR CONSTRUCTION INDEX: 31 OF 36 1 2 3 4 5 6 k 0 0 Y a U U' r 0 ' > ai � a E LLO g � � �� 5 N jZN y Q xwr � Z ¢$ o w x � a O L U IC 0: o _ � `p K a E 1 2 3 4 5 6 ict;j, �p,K 20 443+00.00 20 20 447+00.00 20 20 451+00.00 20 20 455+00.00 20 EL 14.5 10' EL 14.5 10' EL 14.4 10' 1�iN V 10 10 10 i 10 10 10 10 10 EL 7.0 (\//\ EL 7.0 EL 7.0 / 1 E > a > z a - LL 0 0 LL 0 0 0 0 LL 0 0 Z Z Z Z O O O O w -m -10 w / -10 -10 w -10 -10 w -10 :L -m i -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 20 442+00.00 20 20 446+00.00 20 20 450+00.00 20 20 454+00.00 20 D EL 14.5 10 EL 14.5 10 EL 14.5 10 EL 14.3 10 N D N '\ O 10 ' ^ 10 10 10 10 10 10\ 10 � EL 7.0 EL 7.0 � / N �ZZ Z Z eEL7.0� F- LL , 1Z Z-3 LL 0 0 LL 0 0 0 0 LL 0 0 N d W Y~ N~ O O 0 0 Q Z !A W /' pW NW 2 / w w ��/ p= c w w w w ' / V=_i U -10---- -10 -10 -10 -10 -10 -10 -m g 2 0 0 Z -20 -20 -20 -20 -20 -20 -20 2 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 C a " C 441+00.00 445+00.00 449+00.00 453+00.00 20 20 20 20 20 20 20 20 h O EL 14.5 10' EL 14.5 10' EL 14.5 10 EL 14.3 10 i W Z ,^ �n Z 10 10 10 v \ 10 10 10 70 t1 70 EL 7.0 EL 7.0 EL 7.0 (Qj g Q e7.O\ Q Q Q 1'0.1 1°1 2°1 ZO, W LL 0 0 W LL 0 0 IL 0 0 IL LL 0 0 Q e; O W -10 - - -10 W -10 -10 W -10 _ -10 W -10 ' -io tj 4 _ O B m m B U 20 20 20 20 20 20 20 20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 -400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 N DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) LEGEND F 440+00.00 444+00.00 448+00.00 452+00.00 20 20 20 20 20 20 20 20 EXISTING GRADE o EL 14.5 10 EL 14.5 10 EL 14.5 10 EL 14.4 10' PROPOSED N j �, AM o " > n\,� e RENOURISHMENT 10 10 10 10 10 10 10 10 O `\,�,/ )L/� \ / I LIMITS OF FILL EL 7.0 EL7.0 EL 7.0 EL 7.0 \/ > Z > Z > Z > Z h 1 W 201 � LL 0 0 LL 0 0 0 0 LL 0 0 U O F � O F O F O F 10' 0' 10' 20' A w w -// w wVERTICAL SCALE: 1"=10' A 0 -10 -10 -10 -10 -10 -10 -10-----10 100' 0' 100, 200' U SEAL �I h HORIZONTAL SCALE: 1 "=100' � Sheet N 20 20 20 20 20 20 20 2 ISSUED FOR BID Reference No. o 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 APRIL 2020 C-310 NOT TO BE USED FOR CONSTRUCTION INDEX: 32 OF 36 1 2 3 4 5 6 EL 14.2 10' EL 7.0 P 0 0 Y a U O Bi U' ai � E LLO g � � �� 5 N jZN y Q i U'n O off°' Z ¢$ o w x � a O L U IC 0: o _ � K `p a E 1 2 3 4 5 6 ict;j, �p,K 20 459+00.00 20 20 463+00.00 20 20 467+00.00 20 20 471+00.00 20 EL 14.0 10' EL 14.0 10 EL 14.0 10 EL 14.0 10' 1�1„V /\ ,1 10 EL 7.0 \/ 10 10 10 10 EL 7.0 �,.� 10 10 EL 7.0 10 E¢ a eE�-'�' Q a E $ W LL 0 20, 0 W LL 0 ,�.1 0 W 0 20. 0 ... LL 0 10', 0 Z Z Z Z O - � O O O -10--_ ' -10 -to i -to ; -10 -10 -to -10 I -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 20 458+00.00 20 20 462+00.00 20 20 466+00.00 20 20 470+00.00 20 N D EL 14.1 10' EL 14.0 10' EL 14.0 10 EL 14.0 10 D N i N 10 10 10 �v 10 10 ` 10 10 \ \" 10 O N EL 7.0 Q EL 7.0 O EL 7.0 to f"7 > z > z > z > z 0 W z r O LL W 20'1 W 10'1 W 20'1 W 10:1 z-3 Q O F- O cc U r LL o 0, o 0 0 o LL 0 o U) a w r O a Y Cl)O O _� a /_ W O N W w O c CC w w w V=_i U g -m -10w -to -to -10 -10 -to -m � 2 - O E�' z w Q -20 -20 -20 10 -20 -20 -20 -20 cc �+ 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 C >" a C 457+00.00 461+00.00 465+00.00 469+00.00 20 20 20 20 20 20 20 20 h O EL 14.1 1V EL 14.0 10 EL 14.0 10 EL 14.0 1 W 10 0 10 10 a 10 10 0 10 10 e 10 EL 7.0 EL 7.0 (9 z z z z O M10 1 10, 20 1 101 W LL 0 0 W LL 0 0 W 0 0 W LL 0 0 Q h o oe. o zo N N -10 -10 -10 / -10 w -10- --10 -10---10 �j 4 B m m B U 20 20 20 20-20---400 20 20 20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 -300 -200 -100 0 100 400 -300 -200 -100 0 100 N DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) LEGEND F 456+00.00 460+00.00 464+00.00 468+00.00 20 20 20 20 20 20 20 20 EXISTING GRADE o 10 N EL 14.2 EL 14.0 10' EL 14.0 10 EL 14.0 10' PROPOSED AM RENOURISHMENT h 10 10 70 a ^\//^ 10 10 0 10 70 0 10 O EL 7.0 /J\ EL 7.0 EL 7.0 i' EL 7.0 LIMITS OF FILL z z z z W 10.E U LL 0 J 0 LL 0 0 0 0 LL 0 0 O F - O F _ O O 10' 0' 10' 20' A w w / w w VERTICAL SCALE: 1"=10' A -10 -10 -to -1n -10 -10 -10 -10 100' 0' 100' 200. U SEAL �I h HORIZONTAL SCALE: 1 "=100' � Sheet N 20 20 20 20 20 20 20 2 ISSUED FOR BID Reference No. o 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 APRIL 2020 C-311 NOT TO BE USED FOR CONSTRUCTION 1J INDEX. 33 OF 36 ll 1 2 3 4 5 6 0 0 � o 0 rc a U O ai � E LLO g � � �� 5 N jZN y Q i U'n O o �°' Z ¢$ o w x � a O L U IC 0: o _ � `p K a E 1 2 3 4 5 6 ict;j, �p,K 20 475+00.00 20 20 479+00.00 20 20 483+00.00 20 20 487+00.00 20 EL 14.0 10' EL 14.0 10' EL 14.0 10 EL 14.0 10' 1 ' II 11 10 \ 10 10 10 10 EL 7.0 10 10 /r 10 E¢ a Q e7.O( Z W LL 0 1p1 0 Z W LL 0 ,�.1 Z W 0 0 •L0.1 0 Z W LL 0 2p. 1 0 Z Z Z z O O O _ O _ w -10 / -10 w -10 w -10 -10 -10 w / -10 -10 a -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 10 400 -300 -200 DISTANCE (FEET) -100 0 -20 -20 100 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 -20 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 20 474+00.00 20 20 478+00.00 20 20 482+00.00 20 20 486+00.00 20 N D EL 14.0 10 EL 14.0 10' EL 14.0 1U EL 14.0 10'N D N u` 10 10 10 10 10 10 10 10 N EL 7.0 `� m EL 7.0 ( l„ 1 ro EL /� m EL 7.0 ( `/ F- V Z � ; > > O f p1 H ,L0:1 r 2p:1 r p1 2.. Z 0 0 LL 0 0 LL 0 0 0 0 LL 0 0 cn d W O z Y F Cl) IL O O O O a z (n J w O rnw w w ���' O x CC W W W W - g -10 -10 -10 -10 -10 -10 -10 -10V=i ¢ 2 - O z w Q -20 -20 -20 -20 -20 -20 -20 -20 cc �+ 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 C >" a C 473+00.00 477+00.00 481+00.00 485+00.00 20 20 20 20 20 20 20 20 h O EL 14.0 1V EL 14.0 10' � .0 0 EL141 � EL 14.0 1 0 W 10 0 10 10 e 70 10 0 10 10 0 10 EL 7.0 EL7.0 ( /\� EL 7.0 )�' ( / EL 7.0 /� (Qj 0 z z z z O W 1p:1 W yp ° W 2p'1 W 7p.1 Q LL 0 0 LL 0 0 0 0 LL 0 0 h 0 0 0 0 N w -10---10 / w -10---10 w -10 -10 w / -10 -10 4 B m m B U 20 20 20 20 20 20 20 20 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 400 J00 -200 -100 0 100 N DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) LEGEND F 472+00.00 476+00.00 480+00.00 484+00.00 20 20 20 20 20 20 20 20 EXISTING GRADE o N EL 14.0 10 EL 14.0 10' EL 14.0 1U EL 14.0 10 j PROPOSED AM o �\ �1 RENOURISHMENT 10 o t 10 10 a 10 10 0 \��' 10 10 e 10 LIMITS OF FILL 0 EL 7.0 EL7.0 �� EL7.0 (/ EL7.0 z z z z h LL 0 0 LL 0 0 LL 0 0 LL 0 0 U O F _ � O F � _ O F � O F � 10' 0' 10' 20' A w w w w VERTICAL SCALE: 1'. A -10 /' -10 -10 -m -10 -10 -10 -10 100' 0' 100' 200. � U sent �I h HORIZONTAL SCALE: 1 "=100' � Sheet N 20 20 20 20 20 20 20 2 ISSUED FOR BID Reference No. o 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 APRIL 2020 C-312 NOT TO BE USED FOR CONSTRUCTION ci INDEX: 34 OF 36 ll 1 2 3 4 5 6 0 0 rc a U O ai � E LLO g � � �� 5 N jZN y Q i U'n O off°' Z ¢$ o w x � a O L U IC 0: o _ � `p K a E 1 2 3 4 5 6 ict;j, �p,K 20 491+00.00 20 20 495+00.00 20 20 499+00.00 20 EL 14.0 10' EL 14.0 10 i EL 14.0 1U'�, '�I / 1 10 10 .0 \I 10 10 II 10 Q EL 7.0 1� O EL 7.0 E E $ ¢ a Q Z W LL 0 M10' 0 Z W LL 0 20' Z w 0 0- 20:1 0 Z Z Z O O O -10 -10 -10 - w / -10 -10 -10 i -20 400 -300 -200 DISTANCE (FEET) -100 0 1 -20 100 -21 400 -300 -200 DISTANCE (FEET) -100 0 -20 -20 100 400 -300 -200 DISTANCE (FEET) -100 0 -20 100 20 490+00.00 20 20 494+00.00 20 20 498+00.00 20 20 502+00.00 20 N D EL 14.0 1U' EL 14.0 10's EL 14.0 1U'� EL 14.0 10 D N i N 10 EL 7.0 ( /' 10 10 I 1 EL 7.0 1/� 10 ,-. 10 1` EL 7.0 1�/ 10 .-. 10 EL 7.0 �// 10 N Q ✓ Q Q Q C] W z r O LL Z Z 1 Z 10:1 Z 1 z-3 Q O F- O w 0 o LL 0 o w 0 o LL 0 0 J CC cn a U w Y (N O ,- W O� Cl) w 2 w w i' w w S O C 0 w - w w U -10 -10 -10 -10 -10 / -10 -10 m ¢ g 2 - O z -20 -20 -20 -20 -20 -20 -20 -20 cc �+ 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 C > a C 489+00.00 493+00.00 497+00.00 501+00.00 W." 20 20 20 20 20 20 20 20 h O EL 14.0 10'� . EL 14.0 10u. .� EL 14.0 1U'„ i EL 14.0 10' `n W Z i 0 It` e I I I e V' 10 10 10 10 10 10 70 10 EL 7.0 �/ EL 7.0 I \ �� EL 7.0 Z Z Z eE0 Z f 1 H 20'1 H 1 H 10'1 LL 0 0 LL 0 0 LL 0 0 LL 0 0 h 0 0 0 0 e N ' w -10 -10 w -10 w -10 -10 -10 w i -10 -10 �j _ / 4Ic B m m B U -20---400 20 20 20 20 20 20 20 -300 -200 -100 0 100 400 -300 -200 -100 0 100 -400 -300 -200 -100 0 100 400 -300 -200 -100 0 100 N DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) DISTANCE (FEET) LEGEND F 488+00.00 492+00.00 496+00.00 500+00.00 20 20 20 20 20 20 20 20 EXISTING GRADE o N EL 14.0 10' \ EL14.0 10'� EL14.0 1U' EL14.0 10' PROPOSED AM 1 I 1 I RENOURISHMENT y 10 `^ m m e I m m c 1(/, m m 10 LIMITS OF FILL 0 EL7.0 EL 7.0 EL7.0 �7.0\c Z Z Z Z W 20:1 W 'Y0 W 20'1 W i�'1 h U LL 0 0 LL 0 0 LL 0 0 LL 0 0 O F O O O - 10' 0' 10' 20' A w w w w ' VERTICAL SCALE: 1"=10' A �S -10 -10 -10 -m -10 -10 -10 -10 100' 0' 100' 200' U sent �I h HORIZONTAL SCALE: 1 "=100' � Sheet N 20 20 20 20 20 20 20 2 ISSUED FOR BID Reference No. o 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 400 -300 -200 DISTANCE (FEET) -100 0 100 APRIL 2020 C-313 NOT TO BE USED FOR CONSTRUCTION QJ INDEX. 35 OF 36 ll 1 2 3 4 5 6 0 0 Y a U U' E LLO g � � �� 5 N jZN y Q i U'n O off°' Z ¢$ o w x � a O L U IC 0: o _ � `p K `o a E