Loading...
HomeMy WebLinkAbout20210051 Ver 1_Pre-Filing Meeting Request_20210107ID#* 20210051 Version* 1 Regional Office* Raleigh Regional Office - (919) 791-4200 Reviewer List* Stephanie Goss Pre -Filing Meeting Request submitted 1/7/2021 ......................................................................................................................................................................................................................................................................................... Contact Name * Lauren Norris -Heflin Contact Email Address* Project Name* Project Owner* Project County* Owner Address: lauren.norris-heflin@timmons.com East Nash Ecoplexus Nash Street Address 3901 Arlington Highlands Blvd Address Line 2 Suite 200 aty Arlington Rbstal / Zip Code 76018 Is this a transportation project? * r Yes r No State / Frovince / Region Texas Country United States Type(s) of approval sought from the DWR: W 401 Water Quality Certification - F 401 Water Quality Certification - Regular Express r- Individual Permit F Modification r- Shoreline Stabilization Does this project have an existing project ID#?* r Yes r No Do you know the name of the staff member you would like to request a meeting with? Stephanie Goss Please give a brief project description below. This project is for a proposed solar site in Nash County. Three jurisdictional crossings are anticipated for this project. Please reach out if the proposed meeting dates do not work. Please give a couple of dates you are available for a meeting. 1 /12/2021 1 /13/2021 1 /14/2021 1 /15/2021 Please attach the documentation you would like to have the meeting about. East Nash PV2&3 - Zoning Plan - 200601.pdf 982.36KB pdf only By digitally signing below, I certify that I have read and understood that per the Federal Clean Water Act Section 401 Certification Rule the following statements: • This form completes the requirement of the Pre -Filing Meeting Request in the Clean Water Act Section 401 Certification Rule. • I understand by signing this form that I cannot submit my application until 30 calendar days after this pre -filing meeting request. • I also understand that DWR is not required to respond or grant the meeting request. Your project's thirty -day clock started upon receipt of this application. You will receive notification regarding meeting location and time if a meeting is necessary. You will receive notification when the thirty -day clock has expired, and you can submit an application. Signature Submittal Date 1/7/2021 GENERAL PROJECT INFORMATION PROJECT NAME: EAST NASH PROJECT ADDRESS: LAT.: 35.956 LON.:- 78.094 ° DEVELOPER NAME: ECOPLEXUS, INC. DEVELOPER ADDRESS: 101 2ND ST., STE. 1250, SAN FRANCISCO, CA 94105 GENERAL SYSTEM INFORMATION MODULE: HANWHA Q. PEAK DUO L-G52 400 QUANTITY: 145,665 INVERTER: SMA SUNNY CENTRAL 4000 UP - US QUANTITY: 19 MOUNTING SYSTEM: TBD MOUNTING SYSTEM TYPE: SINGLE -AXIS TRACKER 45° TILT, 90° AZIMUTH, 33.0% GCR SYSTEM SIZE (DC): 65.0 MW SYSTEM SIZE (AC): 49.4 MW TOTAL UTILIZED AREA: 298.4 ACRES UTILIZED AREA BY PARCEL: 147.8 ACRES NASH COUNTY 150.6 ACRES SPRING HOPE TOWN NASH COUNTY LANDSCAPING REQUIREMENTS (B) INDUSTRIAL AND COMMERCIAL USES WHENEVER AN INDUSTRIAL OR COMMERCIAL USE IS PROPOSED TO BE LOCATED SO THAT THE PRINCIPAL BUILDING, ACCESSORY BUILDING(S), OUTDOOR USE AREAS, OR PARKING AND LOADING AREAS ARE WITHIN 100 FEET OF A LOT WHICH IS USED FOR RESIDENTIAL PURPOSES OR WHICH IS ZONED FOR RESIDENTIAL USE, THE INDUSTRIAL OR COMMERCIAL USE SHALL PROVIDE SCREENING IN ACCORDANCE WITH THE FOLLOWING STANDARDS: (1) A MINIMUM 25-FOOT PERPETUALLY MAINTAINED NATURAL OR PLANTED BUFFER YARD SHALL BE PROVIDED ALONG ALL PROPERTY LINES DIRECTLY ABUTTING A RESIDENTIALLY USED OR ZONED LOT. (2) THE BUFFER YARD SHALL CONTAIN 3 CANOPY TREES AND 5 UNDERSTORY TREES PER 100 LINEAR FEET OF BUFFER YARD. CANOPY TREES SHALL BE A MINIMUM OF 8 FEET IN HEIGHT AND 2 INCHES IN CALIPER (MEASURED 6 INCHES ABOVE GRADE) WHEN PLANTED. WHEN MATURE, A CANOPY TREE SHOULD BE AT LEAST 40 FEET HIGH AND HAVE A CROWN WIDTH OF 30 FEET OR GREATER. UNDERSTORY TREES SHALL BE A MINIMUM OF 4 FEET HIGH AND 1 INCH IN CALIPER (MEASURED 6 INCHES ABOVE GRADE) WHEN PLANTED. NASH COUNTY LIDO PAGE 11.- 28 - OF 105 (3) THE BUFFER YARD SHALL ALSO CONTAIN 25 SHRUBS PER 100 LINEAR FEET OF BUFFER YARD. ALL SHRUBS SHALL BE OF A SPECIES WHICH CAN BE EXPECTED TO REACH A MINIMUM HEIGHT OF 36 INCHES AND A MINIMUM SPREAD OF 30 INCHES WITHIN 3 YEARS OF PLANTING. (4) ALL PORTIONS OF THE BUFFER YARD NOT PLANTED WITH TREES OR SHRUBS OR COVERED BY A WALL OR OTHER BARRIER SHALL BE PLANTED WITH GRASS, GROUNDCOVER, OR NATURAL MULCH OF A MINIMUM DEPTH OF 3 INCHES. I GENERAL NOTES 1. THE PURPOSE OF THIS PLAN IS TO PROVIDE THE TOWN OF SPRING HOPE AND NASH COUNTY WITH ADEQUATE INFORMATION TO GRANT A SPECIAL/CONDITIONAL USE PERMIT FOR A SOLAR POWER PLANT. 2. THE PROJECT EXTENTS REFLECT THE PROPOSED LOCATION OF THE SOLAR FACILITY- HOWEVER, PERMITTING (STATE AND FEDERAL), AND EQUIPMENT AVAILABILITY MAY REQUIRE MODIFICATIONS TO THE SOLAR ARRAY WITHIN THE FENCED AREA. ANY CHANGES TO THE FENCE THAT INCREASE THE AREA WITHIN THE FENCE WILL BE SUBMITTED FOR STAFF LEVEL REVIEW. THE FINAL ISSUED FOR CONSTRUCTION (IFC) DRAWINGS WILL BE PROVIDED TO THE COUNTY. 3. CURRENT OWNER: UPCHURCH J E HEIRS ET. 5201 PINE WAY DURHAM, NC 27712 FAMILY ACREAGE LLC PO BOX 4, NASHVILLE, NC 27856 EARL AND ROSALENE BASS 1050 BASS RD, NASHVILLE, NC 27856 4. PARCEL ACREAGE / PIN: 318.82 AC / 286000764551 / DB 2819 PG 614 130.49 AC / 286000891057 / DB 2895 PG 772 91.01 AC / 287000092021 / DB 793 PG 165 5. PARCEL CURRENT ZONING: Al 6. SETBACKS (FT): 50' FRONT 15' SIDE 30' REAR 7. AREAS WITHIN THE FENCE OF THE PROPOSED SOLAR ARRAY (ACRES): 251.68 8. PARCEL LINE DATA HAS BEEN OBTAINED FROM NASH COUNTY ONLINE GIS. 9. WETLAND INFORMATION HAS BEEN OBTAINED FROM NATIONAL WETLAND INVENTORY, ONLINE DATABASE (USFWS NWI) 10. SUBJECT PARCEL IS PARTIALLY LOCATED WITHIN A FEDERALLY DESIGNATED FLOOD HAZARD AREA- (FEMA PANEL 3720286000J, EFFECTIVE DATE: 11/3/2004). 11. NO PERMANENT LIGHTING IS PROPOSED FOR THIS SITE. 12. ON -SITE STRUCTURES WILL NOT EXCEED 15-FEET IN HEIGHT EXCLUDING UTILITY POLES. 13. DURING REGULAR OPERATION THE SITE WILL BE UNMANNED AND MONITORED REMOTELY. 14. A DRIVEWAY PERMIT (OR PERMITS) WILL BE OBTAINED FROM DOT PRIOR TO CONSTRUCTION. 15. AN EROSION AND SEDIMENT CONTROL PERMIT WILL BE OBTAINED FROM DEQ PRIOR TO CONSTRUCTION. 16. BUILDING AND ELECTRICAL PERMITS WILL BE OBTAINED BY THE DEVELOPER PRIOR TO COMMENCEMENT OF EACH RESPECTIVE ACTIVITY. 17. A TEMPORARY STAGING AREA WILL BE ESTABLISHED DURING CONSTRUCTION. UPON COMPLETION OF CONSTRUCTION THIS AREA WILL BE REMOVED. ANY SOIL OR GRAVEL PATHS MAY REMAIN FOR LONG-TERM SITE ACCESS. 18. THE PROPOSED SOLAR ARRAY WILL BE ENCLOSED BY A 6-FOOT TALL CHAIN LINK FENCE WITH 3 STRANDS OF BARBED WIRE ALONG THE TOP. TOTAL FENCE HEIGHT WILL BE 7-FEET. 19. GATE CODES WILL BE PROVIDED TO LOCAL EMERGENCY PERSONNEL. 20. SIGNAGE WILL BE PLACED ON THE OUTSIDE OF THE FENCE PER CODE NEC 110.34 (C). PARCELS, TOPOGRAPHY, ROADS, WETLANDS, STREAMS, PONDS, EASEMENTS, RIGHT-OF-WAYS, UTILITIES, ETC., ARE OBTAINED FROM COUNTY GIS DATA. THIS DRAWING IS THE PROPERTY OF ECOPLEXUS INC. THIS INFORMATION IS CONFIDENTIAL AND IS TO BE USED ONLY IN CONNECTION WITH WORK DESCRIBED BY ECOPLEXUS INC. NO PART IS TO BE DISCLOSED TO OTHERS OR REPRODUCED WITHOUT WRITTEN PERMISSION FROM ECOPLEXUS INC. OR ITS SUBSIDIARIES. PROPERTY BOUNDARY (TYP.) 150 FT PROPERTY BOUNDARY F SETBACK (TYP.) till Cry � ZONING BOUNDARY (TYP.) RIVERINE (TYP.) _ nnnnnnnnnnnnnn.... - � � iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii 150 FT PROPERTY BOUNDARY SETBACK (TYP.) 15 FT PROPERTY BOUNDARY SETBACK (TYP.) POND (TYP.) S� I I I 30 FT PROPERTY BOUNDARY I SETBACK (TYP.) , PROPERTY BOUNDARY (TYP.) 100 FT PROPERTY BOUNDARY SETBACK (TYP.) \ 150 FT PROPERTY BOUNDARY SETBACK (TYP.) ACCESS POINT 10 FT WETLAND VOLUNTARY / SETBACK �[ BASS PARCEL �rrf 30 FT SETBACK TO NEIII s �NASH COUNTY I�'! IIIIIIIIIIIIII t� S P ING HOPE l` 10 FT WETLAND VOLUNTARY SETBACK 10% SLOPE ,fr1. .,1. Li . 1. ! 1 �=VR�aR�� r1 TT�A TTTR EX2.O �N -111ALE Mandatory Screening with 30' setbacks: �o wvxixv vEwsorxuwrixo NOTESM,�o„M�.M�MSPa.o. 150 FT PROPERTY BOUNDARY SETBACK (TYP.) J PROPERTY BOUNDARY (TYP.) \ • EXIST OVERHEAD ELECTRICAL (TYP.) 50' OHE EASTMENT (TYP.) OWNER'S ELECTRICAL SUBSTATION APPROXIMATE POINT OF INTERCONNECTION (POI) APPROXIMATE SIZE AND LOCATION OF UTILITY'S SUBSTATION PROPERTY BOUNDARY (TYP.) - - R{�ILROAO T-0" • • • • • • • • r1 ,0 N TT7S ALE ELEVATio-1- Elective Screening with 30' setbacks: TRACKER DETAIL J IN: 1'-0" :ER] �C 500' 250' 0 500' SCALE: 1" = 500' Cn D Ln x m 0w� *C .Q M � T U O(n N Re O XU"?IZ J T Ln Ln W 0 m � � m -��1►� W mU.aU_j cn c we�1►� z u� STAMP/SEAL PRELIMINARY DO NOT USE FOR CONSTRUCTION z 0 Q a z 0 0 U Of 0 w z O U U) w p w Q p > w w o_ O 0 Fh z_ a- Q J (n Z LL J O Of Z < z 0 U p O = O z 0 z I..LI L, Z C° o U U) Q z CIVIL REVIEW: JMH DEV. REVIEW: MW DESIGNED BY: BAB DRAWN BY: AG SCALE: 1 "=500' DATE: 05/04/2020 DRAWING DESCRIPTION: ZONING PLAN DRAWING No: PV2-3.1