Loading...
HomeMy WebLinkAboutSW8991121_CURRENT PERMIT_20000214STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SWleiI�I DOC TYPECURRENT PERMIT APPROVED PLANS ❑ HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE I o`2lJ7J1!CJ�la �`-{ YYYYMMDD 1 State of North Carolina Depairtment of Environment and Natural Resources Wilmington Regional Office James B. Hunt, Jr., Governor Bill Holman, Secretary Division of Water Quality February 14, 2000 Mr. Scott McMillan, General Partner Waller -McMillan Partners c/o Gull Isle Realty PO Drawer 550 Atlantic Beach, NC 28512 1 � • NCDENR NORTH CAROUNA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Permit No. SW8 991121 Bluff s View High Density Stormwater Project Carteret County Dear Mr. McMillan: The Wilmington Regional Office received a complete Stormwater Management Permit Application forBluffs View on January 19, 2000. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000. We are forwarding Permit No. SW8 991121 dated February 14, 2000, for the construction of Bluffs View. This permit shall be effective from the date of issuance until February 14, 2010, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the Operation and Maintenance requirements in this permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and Minding. If you have any questions, or need additional information concerning this matter, please contact Linda Lewis, or me at (910) 395-3900. Sincerely, Rick Shiver Water Quality Regional Supervisor RSS/arl: S:1WQSISTORMWATIPERMIT1991121.FEB CC' Ron Cullipher, P.E. Katrina Marshall, Carteret County Inspections Linda Lewis Wilmington Regional Office Central Files 127 Cardinal Dr. Ext., Wilmington, North Carolina 28405 Telephone 910-395-3900 FAX 910-350-2004 An Equal Opportunity Affirmative Action Employer 50% recycled110% post -consumer paper State Stormwater Management Systems Permit No. SW8 991121 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Waller -McMillan Partners Bluffs View Carteret County Wrl; r ;f construction, operation and maintenance of a wet detention pond in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until February 14, 2010 and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater control has been designed to handle the runoff from 37,013 square feet of impervious area. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 4. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 2 0 State Stormwater Management Systems Permit No. SW8 991121 Project Name: Permit Number: Location: Applicant: Mailing Address: Application Date: Name of Receiving Stream/Index 4: Classification of Water Body: If Class SA, chloride sampling resul Pond Depth, feet: Permanent Pool Elevation, FMSL: Drainage Area, acres: Total Impervious Surfaces, ft'. Offsite Area entering Pond, ft': Required Surface Area, ft': Provided Surface Area, ft': Required Storage Volume, ft3: Provided Storage Volume, ft': Temporary Storage Elevation, FMS Controlling Orifice: DIVISION OF WATER QUALITY PROJECT DESIGN DATA SHEET Bluffs View SW8 991121 Carteret County Mr, Scott McMillan, General Partner Waller -McMillan Partners c/o Gull Isle Realty PO Drawer 550 Atlantic Beach, NC 28512 January 19, 2000 Peltier Creek / (WHO 20-36-11) "SB4" ts: nla 4 6.5 1.72 37,013 n/a 3,186 3,279 3,088 4,108 L: 7.5 l "� pipe I State Stormwater Management Systems Permit No. SW8 991121 II. SCHEDULE OF COMPLIANCE The stormwater management system shall be constructed in it's entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of side slopes. d. Immediate repair of eroded areas. e. Maintenance of side slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device and catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. Decorative spray fountains will not be allowed in the stormwater treatment system. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. The following items will require a modification to the permit: a. Any revision to the approved plans, regardless of size. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area. e. Further subdivision, acquisition, or sale of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 10. The Director may determine that other revisions to the project should require a modification to the permit. 4 State Stormwater Management Systems Permit No, SW8 991121 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. Prior to the sale of any portion of the property, an access/maintenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale of any portion of the property. 13. The permittee is responsible for verifying that the proposed built -upon area does not exceed the allowable built -upon area. 14. The runoff from all built -upon area on the project must be directed into the permitted stormwater control system. 15. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. III. GENERAL CONDITIONS This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Water Quality accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. Permit issued this the 14th day of February, 2000. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Kerr T. Stevens, Direc or Division of Water Quality By Authority of the Environmental Management Commission Permit Number SW8 991121 5 State Stormwater Management Systems Permit No. SW8 991121 Bluff s View Stormwater Permit No. SW8 991121 Carteret County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, ect) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature Registration Number Date SEAL 0 State Stormwater Management Systems Permit No. SWS 991121 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. The outlet/bypass structure elevations are per the approved plan. S. The outlet structure is located per the approved plans. 6. Trash rack is provided on the outlet/bypass structure. 7. All slopes are grassed with permanent vegetation. S. Vegetated slopes are no steeper than 3.1. 9. The inlets are located per the approved plans and do not cause short-circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. 11. Required drawdown devices are correctly sized per the approved plans. 12. All required design depths are provided. 13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 14. The overall dimensions of the system, as shown on the approved plans, are provided. cc: NCDENR-DWQ Regional Office Katrina Marshall, Carteret County Building Inspector 7 �60VFIC y.VSE',ONL-Yo Date Received Fee Paid Permit Number = I q- 2000 1 1 420 5 sGv -x 9R 1 zl State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM This form may be photocopied for use as an original I. GENERAL INFORMATION 1. Applicants name (specify the name of the corporation, individual, etc. who owns the project): Wa fer- � s 2. Print Owner/Signing Official's name and title (person legally responsible for facility and compliance): Mailing Address for person listed in item 2 above: _'% I I Isle_ Real-+Q , P.O. Drawee �Ssv City: A±!a r) H(_ Pie a C () - State: N L Zip: 2.e5 I "I _ Telephone Number:( 252) 7a6- n427 4. Project Name (subdivision, facility, or establishment name -should be consistent with project name on plans, specifications, letters, operation and maintenance agreements, etc.): . V) e�1-- 5. Location of Project (street address): May�c'pi e_'i d I ay, kW a u -- City: County: CA1_-l-eV_ET_ 6. Directions to project (from nearest major intersection): .d, 70) le r�. .7 Latitude: - 7�y'" �i 717 10 Longitude: 34°-- 43--SO1 I _ of project 8. Contact person who can answer questions about the project: Name: SC-0-H � C_4 1 (a!/t _ Telephone Number: (2�2) 72(o J (04'27 II. PERMIT INFORMATION: 1. Specify whether project is (check one): New Renewal Modification Form SWU-101 Version 3.99 Pave 1 of 4 2. If this application is being submitted as the result of a renewal or modification to an existing pernut, list the - existing permit number and its issue date (if 1wown) 3. Specify the type of project (check one): Low Density _X_High Density Redevelop General Permit Other 4. Additional Project Requirements (check applicable blanks): CAMA Major IKSedirnentation/Erosion Control - 404/401 Permit _NPDES Stormwater Information on required state pe: its can be obtained by contacting the Customer Service Center at 1-877-623-6748. III. PROJECT INFORMATION 1. In the space provided below, summarize how stormwater will be treated. Also attach a detailed narrative (one to two pages) describing stormwater management for the project. W e.-+ D nijib h 90'/ �TSS rc nno vo] 2. Stormwatei runoff from this project drains to the W k1 ic, t. a k River basin. 3. Total Project Area: 1, 7 2 acres 4. Project Built Upon Area:__ 4 1,_ A-_ % 5. How many drainage areas does the project have? 6. Complete the following information for each drainage area. If there are more than two drainage areas in the project, attach an additional sheet with the information for each area provided in the same format as below. �UrvnageArealk nBasrriIlformatton�RA , ca € a b, , Dia}nageArea Zk „ Receiving Stream Name e `e-h e� Cr Receiving Stream Class -c— SB4f— Drainage Area 24- SF- Existina Impervious* Area F Proposed Im ervious*Area 3 7j S % Impervious* Area (total) , 41. Im ervioos ',Surfaee :Area .. �,� Drains e Aiea 1 „ .mot ..... g... aina a `AreaN2 k g • f On -site Buildings On -site Streets 19UQsr On -site Parking F On -site Sidewalks Other on -site mod-, as _S S 9 S E Off -site Total: Total: Impervious area is defined as the built upon area including, but not limited to, buildings, roads, parking areas, sidewalks, gravel areas, etc. Form SWU-10t Version 3.99 Page 2 of 4 i . J 7. How was the off -site impervious area listed above derived? N IV. DEED RESTRICTIONS AND PROTECTIVE COVENANTS The following italicized deed restrictions and protective covenants are required to be recorded for all subdivisions, outparcels and future development prior to the sale of any lot. If lot sizes vary significantly, a table listing each lot number, size and the allowable built -upon area for each lot must be provided as an attachment. I. The following covenants are intended to ensure ongoing compliance with state stormwater management permit number as issued by the Division of Water Quality. These covenants may not be changed or deleted without the consent of the State. 2. No more than square feet of any lot'shall be covered by structures or impervious materials. Impervious materials include asphalt, gravel, concrete, brick, stone, slate or similar material but do not include wood decking or the water surface of swimming pools. 3. Swales shall riot be filled in, piped, oral tered except as necessary to provide driveway crossings. 4. Built -upon area in excess of the permitted amount requires a state stormwater management permit modification prior to construction. 5. All pemiitted runoff frorn outparcels or future development shall be directed into the permitted stormwater control system. These connections to the stormwater control system shall be performed in a manner that maintains the integrity and performance of the system as permitted. By your signature below, you certify that the recorded deed restrictions and protective covenants for this project shall include all the applicable items required above, that the covenants will be binding on all parties and persons claiming under them, that they will run with the land, that the required covenants cannot be changed 'or deleted without concurrence from the State, and that they will be recorded prior to the sale of any lot. V. SUPPLEMENT FORMS The applicable state stormwater management permit supplement form(s) listed beldw'must be submitted for each BMP specified for this project. Contact the Stormwater and General Permits Unit at (919) 733-5083 for the status and availability of these farms. Form SWU-102 Wet Detention Basin Supplement Form SWU-103 Infiltration Basin Supplement Form SWU-104 Low Density Supplement Form SWU-105 Curb Outlet System Supplement Form SWU-106 Off -Site System Supplement Form SWU-107 Underground Infiltration Trench Supplement Form SWU-108 Neuse River Basin Supplement Form SWU-109 Innovative Best Management Practice Supplement. Form SWU-101 Version 3.99 Page 3 of 4 VI. SUBMITTAL REQUIREMENTS Only;complete application packages will be accepted and reviewed by the Division of Water Quality (DWQ). A complete package includes all of the items listed below. The complete application package should be submitted to the appropriate DWQ Regional Office. Please indicate that you have provided the following required information by iiutialing in the space provided next to each item. • Original and one copy of the Stormwater Management Permit Application Form • One copy of the applicable Supplement Form(s) for each BMP • Permit application processing fee of $420 (payable to NCDENR) • Detailed narrative description of stormwater treatment/management • Two copies of plans and specifications, including: - Development/Project name - Engineer and firm t -Legend - North arrow - Scale - Revision number & date - Mean high water line - Dimensioned property/project boundary - Location map with named streets or NCSR numbers - Original contours, proposed contours, spot elevations, finished floor elevations - Details of roads, drainage features, collection systems, and stormwater control measures - Wetlands delineated, or a note on plans that none exist - Existing drainage (including off -site), drainage easements, pipe sizes, runoff calculations - Drainage areas delineated - Vegetated buffers (where required) VII. AGENT AUTHORIZATION If you wish to designate authority to another individual or firm so that they may provide information on your behalf, please complete this section.' Designated agent (individual on firm). 'S-"U , t�j aeCV (�t61 Mailing Address:_ �_� _ A 4Ly _2-¢ S� City: vor,° State:r\1G 2 _ Zip: _ 1�L—� Phone: ( 2752 )- 247 *7 � _ Fax: (-25 2, VIII. APPLICANT'S CERTIFICATION I, (print or type name of person listed in General Information, item 2) SCH't C- k4�- certify that the information included on this permit application form is, to the best of my knowledge; correct and that the project will be constructed in conformance with the approved plans, that the required deed restrictions and protective covenants will be recorded, and that the proposed project complies with the requirements of 15A NCAC 2H .1000. Signatu Form 5WU-101 Version 3.99 Page 4 of 4 Permit No. S6'J;?6(_91 1 Z( (to be provided by DWQ) State of North Carolina Department of Environment and Natural Resources Division of Water Quality STORMWATER MANAGEMENT PERMIT APPLICATION FORM WET DETENTION BASIN SUPPLEMENT This form may be photocopied for use as an original DWQ Storinwater Management Plan Review: A complete stormwater management plan submittal includes an application form, a wet detention basin supplement for each basin, design calculations, and plans and specifications showing all basin and outlet structure details. .I. PROJECT INFORMATION Project Name: Contact Person: `:eD.ft MC04 _11a1/l. Phone Number: (ZS2Z� `QA2_ For projects with multiple basins; specify which basin this worksheet applies to:.... N / A elevations Basin Bottom Elevation Permanent Pool Elevation Temporary Pool Elevation areas 2 . S ft. T Permanent Pool Surface Areasq Drainage Area ac 3r7 013 s14, Impervious Area volumes Permanent Pool Volume Temporary Pool Volume Forebay Volume Other parameters SA/DA I Diameter of Orifice Design Rainfall Design TSS Removal 2 Form SWU-102 Rev 3.99 ft. ,Dr� cu. ft. 4.1 . -• cu. ft. cu. ft. k, (floor of the basin) (elevation of the orifice) (elevation of the discharge structure overflow) (water surface area at the orifice elevation) (on -site and off site drainage to the basin) (on -site and off -site drainage to the basin) (combined volume of main basin and forebay) (volume detained above the permanent pool) (approximately 20% of total volume) 25 (surface area to drainage area ratio from DWQ table) in. (2 to 5 day temporary' pool draw -down required) j in. % (minimum. 85% required) Page 1 of 4 Footnotes: 1 When using the Division SA/DA tables, the correct SA/DA ratio for permanent pool sizing should be computed based upon the actual impervious.% and permanent pool depth. Linear interpolation should_ be employed to determine the correct value for non- standard table entries. 2 In the 20 coastal counties, the requirement for a vegetative filter may be waived if the wet detention basin is designed to provide 90% TSS removal. The NCDBNR BMP manual provides design tables for both 85% TSS removal and 90% TSS removal. II. REQUIRED ITEMS CHECKLIST The following checklist outlines design requirements per the Stormwater Best Management Practices Manual (N.C. Department of Environment, Health and Natural Resources, February 1999) and Administrative Code Section: 15 A NCAC 2H .1008. Initial in the space provided to indicate the following design requirements have been met and supporting documentation is attached. If the applicant has designated an agent in the Stormwater Management Permit Application Form, the agent may initial below. If a requirement has not been met, attach justification. Applicants Initials a. b. .�C C. d. k ,R e. M The permanent pool depth is between 3 and 6 feet (required minimum of 3 feet). The forebay volume is approximately equal to 20% of the basin volume. The temporary pool controls runoff from the design storm event. The temporary pool draws down in 2 to 5 days. If required, a 30-foot vegetative filter is provided at the outlet (include non -erosive flow calculations) f. The basin length to width ratio is greater than 3:1. g. The basin side slopes above the permanent pool are no steeper than 3:1. h. A submerged and vegetated perimeter shelf with a slope of 6:1 or less (show detail). Vegetative cover above the permanent pool elevation is specified. A trash rack or similar device is provided for both the overflow and orifice. tf k. A recorded drainage easement is provided for each basin including access to nearest right- of-way. 1. If the basin is used for sediment and erosion control during construction, clean out of the basin is specified prior to use as a wet detention basin., -- . h] m. A mechanism is specified which will drain the basin,for maintenance or an emergency. l III. WET DETENTION BASIN OPERATION AND MAINTENANCE AGREEMENT The wet detention basin system is defined as the wet detention basin, pretreatment including forebays and the vegetated filter if one is provided. This system (check one) 0 does Vdoes not incorporate a vegetated filter at the outlet. This system (check one) 0 does does not incorporate pretreatment other than a forebay. Form SWU-102 Rev 3.99 Page 2 of 4 Maintenance activities shall be performed as follows: . 1. After every significant runoff producing rainfall event and at least monthly: a. Inspect the wet detention basin system for sediment accumulation, erosion, trash accumulation, vegetated cover, and general condition. b. Check and clear the orifice of any obstructions such that drawdown of the temporary pool occurs within 2 to 5 days as designed. 2. Repair eroded areas immediately, re -seed as necessary to maintain good vegetative cover, mow vegetative cover to maintain a maximum height of six inches, and remove trash as needed. Inspect and repair the collection system (i.e. catch basins, piping, swales, riprap, etc.) quarterly to maintain proper functioning. 4. Remove accumulated sediment from the wet detention basin system sdmi-annually or when depth is reduced to 75% of the original design depth (see diagram below). Removed sediment shall be disposed of in an appropriate manner and shall be handled in a manner that will not adversely impact water quality (i.e. stockpiling near a wet detention basin or stream, etc.). The measuring device used to determine the sediment elevation shall -be such that it will give an accurate depth reading and not readily penetrate into accumulated sediments. When the permanent pool depth reads feet in the main pond, the sediment shall be removed. ,et�t�ettpa�a When the permanent pool depth reads 2 feet in the forebay, the sediment shall''b :removed , Sediment Bottom E1.4,26_ 75 on --3 FOREBAY BASIN DIAGRAM r w (fill in the blanks) f> ° / • ' Permanent Pool Elevation�7`'— Sediment Removal Elevation Bottom Elevation CD MAIN POND 75% 25% 5. Remove cattails and other indigenous wetland plants when they cover. 50% of the basin surface. These plants shall be encouraged to grow along the vegetated shelf and forebay berm. 6. If the basin must be drained for an emergency or to perform maintenance, the flushing of sediment through the emergency drain shall be minimized to the maximum extent practical. Form SWU-102 Rev 3.99 Page 3 of 4 7. All components of the wet detention basin system shall be maintained in good working order. I acknowledge and agree by my signature below that I am responsible for the performance of the seven maintenance procedures listed above. 1 agree to notify DWQ of any problems with the system or prior to any changes to the system or responsible party. Print name: So++ Nlf1Uf (a.k--) Title: P/L Address: _ _CIo 02y 1 --ESie Rea�+u ,_p0 :Drab-r SSO , AAlarifir 13e r NL2g512 Phone: (2,52) TZ& - Q4: E Signa Date: Note: The legally responsible party should not be a homeowners association unless more than 50% of the lots have been sold and a resident of the subdivision has been named the president. I, fkT't`ks,) tamiu.jn T, a Notary Public for the State of 60-0-rJ CR IZ1UdA County of ._ ( e�u�,i , do hereby certify -that _ SC.ort- C i"1-1gtd personally appeared before me this A-) day of A�u�/�'� , C: D7", and acknowledge the due execution of the forgoing wet detention basin maintenance requ' meats. Witn s my and and official seal, l CSV8, z sales All SEAL My commission expires ()CT 4V rAd&Y Form SWU-102 Rev 3.99 Page 4 of 4 s i . t rlwo_V`0�4 2002 1, STROUD ENGINEERING, P.A. HESTRON PLAZA TWO 151-A HWY. 24 MOREHEAD CITY, NORTH CAROLINA 28557 (252) 247-7479 October 30, 2002 Mr. Rick Shiver NCDENR — Wilmington Regional Office Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Bluffs View -� High Density Stormwatcr Project Carteret County SW8 991121 _ Owner: Mr. Scott McMillan, General Partner Waller -McMillan Partners CIO Gull Isle Realty P.O. Drawer 550 Atlantic Beach, NC 28512 Dear Mr. Shiver, Please find enclosed the Engineer's Certification and Requirements Checklist for the referenced project. This project's stormwater facilities have been installed in accordance with the approved plans and specifications. Sincerely, '9``QG1p17pppp/Ipi m�o� P"CH CqR •�o Q a/o.�-�- 14 • ' P A r: Ro ld D. Cullipher, P.E. Date p 1334 :0 4. Cc: Mr. Scott McMillan, Waller -McMillan Partners 'titles CUi 0eaw�` 107 COMMERCE ST. HESTRON PLAZA TWO SUITE B 102-D CINEMA DRIVE 151-A HWY, 24 GREENVILLE, NO 27858 WILMINGTON, NO 28403 MOREHEAD CITY, NO 28557 (252) 756-9352 (910) 815-0775 (252) 247-7479 State gtormwater Management Systems Permit No. SW8 991121 Bluffs View Stormwater Permit No. SW$ 991121 Carteret County Designer's Certification I, , as a duly registered G in the State of N6r-tR Carolina, having be authorized to obsery erio ] /weekly/full time) the construction of the project, SLu FF ' 5 VS 5Lt _ „ (Project) for 5c �44 M c ZZ A N _ (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. _ 4�1, The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: Signature vnL Registration Number j �3 Date D UL- oall9A09000of e4 +, 0� ........ •i'• �•� j.���i9 0w ?SEAL SEAL i i 13343 a ='33. OZ •• �NGZz ! N� CULL'; ++++tenr9,w 6 State Stormwater Management Systems Permit No. SW8 991121 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. _AD2. The drainage area to the system contains no more than the permitted amount of built -upon area. _QL3. All the built -upon area associated with the project is graded such that the runoff drains to the system. AD�_4. The outlet/bypass structure elevations are per the approved plan. _5. The outlet structure is located per the approved plans. AD`6. Trash rack is provided on the outlet/bypass structure. g,Q_7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. 'The inlets are located per the approved plans and do not cause short-circuiting of the system. �10. The permitted amounts of surface area and/or volume have been provided. &LI l . Required drawdown devices are correctly sized per the approved plans. L LI2. All required design depths are provided. _ffiC13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. R QU 4. The overall dimensions of the system, as shown on the approved plans, are provided. cc: NCDENR-DWQ Regional Office Katrina Marshall, Carteret County Building Inspector A 7