Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW8120102_HISTORICAL FILE_20120130
STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW8 ten o-7 DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS © HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE ZDl'?- (I>, 30 YYYYMMDD A IRK% pper��®®� NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Wakild, P. E. Governor Director January 30, 2012 Commanding Officer MCB Camp Lejeune c/o Carl Baker, Deputy Public Works Officer Building 1005 Michael Road Camp Lejeune, NC 28547 Dee Freeman Secretary Subject: State Stormwater Management Permit No. SW8 120102 Courthouse Bay BEQ at Munro Road High Density Commercial Wet Detention Pond Project (Class SA waters) Onslow County Dear Mr. Baker: The Wilmington Regional Office received a complete Stormwater Management Permit Application for the Courthouse Bay BEQ at Munro Road on January 30, 2012. Staff review of the plans and specifications has determined that the project, as proposed, will comply with the Stormwater Regulations set forth in Title 15A NCAC 2H.1000 and Session Law 2008-211. We are forwarding Permit No. SW8 120102 dated January 30, 2012, for the construction, operation and maintenance of the BMP's and built -upon area associated with the subject project. This permit shall be effective from the date of issuance until January 30, 2020, and shall be subject to the conditions and limitations as specified therein. Please pay special attention to the conditions listed in this permit regarding the Operation and Maintenance of the BMP(s), recordation of deed restrictions, procedures for changes of ownership, transferring the permit, and renewing the permit. Failure to establish an adequate system for operation and maintenance of the stormwater management system, to record deed restrictions, to transfer the permit, or to renew the permit, will result in future compliance problems. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing by filing a written petition with the Office of Administrative Hearings (OAH). The written petition must conform to Chapter 150B of the North Carolina General Statutes, and must be filed with the OAH within thirty (30) days of receipt of this permit. You should contact the OAH with all questions regarding the filing fee (if a filing fee is required) and/or the details of the filing process at 6714 Mail Service Center, Raleigh, NC 27699-6714, or via telephone at 919-431-3000, or visit their website at www.NCOAH.com. Unless such demands are made this permit shall be final and binding. If you have any questions, or need additional information concerning this matter, please contact Christine Nelson, at (910) 796-7215. Sin erely, Sin Wakild, aPPPEDirector Division of Water Quality GDSI can: S:IWQSIStormwater\Permits & Projects120121120102 HD12012 01 permit 120102 CC' Howard Resnik, Coastal Site Design Wilmington Regional Office Stormwater File Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One Phone: 910-796-72151 FAX: 910350-20041 DENR Assistance: 1-877-623-6748 NofthCarolina Intemet: www.nmaterquality.org �/ y �' y atma l An Equal opporlunky 1 Affirmative Action Employer ``/✓� State Stormwater Management Systems Permit No. SW8 120102 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY COMMERCIAL DEVELOPMENT SA WATERS In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO MCB Camp Lejeune Courthouse Bay BEQ at Munro Road Command Drive and Monro Road, Camp Lejeune, Onslow County FOR THE construction, operation and maintenance of one (1) wet detention pond discharging to a level spreader/ vegetated filter strip draining to Class SA waters in compliance with the provisions of 15A NCAC 2H .1000 and Session Law 2008-211 (hereafter collectively referred to as the "stormwater rules') the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of. Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until January 30, 2020, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described in Section 1.9 on page 3 of this permit. The stormwater control has been designed to handle the runoff from 234,164 sf of impervious area. 3. A 50' wide vegetative buffer must be provided and maintained adjacent surface waters, measured horizontally from and perpendicular to the normal pool of impounded- structures, the top of bank of both sides of streams and rivers and the mean high water line of tidal waters. 4. The volume in excess of the design storm from the wet pond must flow overland through a level spreader and 50-foot vegetated filter strip designed to pass the peak flow from the 10 year storm in a diffuse, non -erosive manner. 5. The drainage area(s) will be limited to the amount(s) of built -upon area indicated in Sections 1.2 and 1.8 of this permit, and per approved plans. The built -upon area for the future development is limited to 1,OOO,square feet. Page 2of8 State Stormwater Management Systems Permit No. SW8 120102 C 7 All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all required easements. The runoff from all built -upon area within the permitted drainage area(s) of this project must be directed into the permitted stormwater control system. The following design criteria have been provided in the wet detention pond and must be maintained at design condition: . a. Draina a Area, acres: gnsite ft2. Offsite, ft . b. Total Impervious Surfaces, ft2: Onsite, ft Offsite, ft2: c. Design Storm, inches: d. Average Pond Design Depth, feet: e. TSS removal efficiency: f. Permanent Pool Elevation, FMS.�: g. Permanent Pool Surface Arei, ft h. Permitted Storage Volume, ft : i. Temporary Storage Elevation, FMSL: j. Pre-dev. 1 yr-24 hr. discharge rate, cfs: k. Controlling Orifice: I. Orifice flowrate, cfs: M. Permitted Forebay Volume, ft3: n. Fountain Horsepower: o. Receiving Stream/River Basin: P. Stream Index Number: q. Classification of Water Body: 10.14 441,826 none 234,164 234,164 none 3.8 4.0 90% 25.0 25,515 68,782 27.3 0.2 2.7" O pipe 0.17 19,107 1/3 HP Courthouse Bay / White Oak 19-36 "SA, HQV11" 9. The design storm volume discharged from the wet pond must be directed to a level spreader / vegetated filter strip designed to effectively infiltrate the design storm and to pass the peak flow from the 10-year stomr in a diffuse, non -erosive manner. The following design criteria have been provided in the secondary BMP and must be maintained at design condition: a. Peak Discharge: Design Storm, cfs: 0.17 10-yr Storm, cfs: 3.40 b. Length of Level Spreader, ft: 40 C. Width of Vegetated Filter Strip, ft: 100 d. Slope of Vegetated Filter Strip: 1.0% 11. SCHEDULE OF COMPLIANCE 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. Page 3of8 State Stormwater Management Systems Permit No. SW8 120102 3. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, the permittee shall cause a certification from an appropriate designer for the system installed to be submitted, certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification may be required for those deviations. 4. If the permanent pool volume is greater than 30,000 cubic feet, a decorative spray fountain will be allowed in the stormwater treatment system, subject to the following criteria: a. The fountain must draw its water from less than 2' below the permanent pool surface. b. Separated units, where the nozzle, pump and intake are connected by tubing, may be used only if they draw water from the surface in the deepest part of the pond. c. The falling water from the fountain must be centered in the pond, away from the shoreline. d. The maximum horsepower for a fountain in this pond is 113 horsepower. 5. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals. 6. Records of maintenance activities must be kept and made available upon request to authorized personnel of DWQ. The records will indicate the date, activity, name of person performing the work and what actions were taken. 7. The facilities shall be constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 8. If the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Redesign or addition to the approved amount of built -upon area or to the drainage area. C. Further development, subdivision, acquisition, lease or sale of any, all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. d. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. e. The construction of any permitted BUA within the undeveloped future areas shown on the approved plans. Page 4 of 8 State Stormwater Management Systems Permit No. SW8 120102 10. Clear access to the stormwater facilities for inspection and maintenance shall be maintained via appropriately recorded easements. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee at all times. 12. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 111. GENERAL CONDITIONS This permit is not transferable to any person or entity except after notice to and approval by the Director. At least 30 days prior to a change of ownership, or a name change of the permittee or of the project, or a mailing address change, the permittee must submit a completed and signed Name/Ownership Change Form to the Division of Water Quality, accompanied by the supporting documentation as listed on the form. The approval of this request will be considered on its merits and may or may not be approved. 2. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. Neither the sale of the project nor the conveyance of common area to a third party constitutes an approved transfer of the stormwater permit. 3. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 4. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances, which may be imposed by other government agencies (local, state, and federal) having jurisdiction. 5. In the event that the facilities fail to perform satisfactorily the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. Additional or replacement stormwater management systems shall receive a permit from the Division prior to construction. 6. The permittee grants DEN Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 7. The permit remains in force and effect until modified, revoked, terminated or renewed. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and re - issuance or termination does not stay any permit condition. 8. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 9. Approved plans, specifications, application forms, and design calculations for this project are incorporated by reference and are enforceable parts of the permit. Page 5 of 8 State Stormwater Management Systems Permit No. SW8 120102 10, The permittee shall submit a permit renewal request at least 180 days prior to the expiration date of this permit. The renewal request must include the appropriate documentation and the processing fee. Permit issued this the 301h day of January 2012. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION Division of Water Quality By Authority of the Environmental Management Commission Page 6 of 8 State Stormwater Management Systems Permit No. SW8 120102 Courthouse Bay BEQ at Munro Road Stormwater Permit No. SW8 120102 Onslow County Designer's Certification I, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/ weekly/ full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specifications: Signature Registration Number Date SEAL Page 7 of 8 State Stormwater Management Systems Permit No. SW8 120102 Certification Requirements: 1. The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. All roof drains are located such that the runoff is directed into the system. 5. The outlet structure elevations are per the approved plan. 6. The outlet structure is located per the approved plans. 7. Trash rack is provided on the outlet structure. 8. All slopes above permanent pool are grassed with permanent vegetation. 9. Vegetated slopes above permanent pool are no steeper than 3:1. 10. The inlets are located per the approved plans and do not cause short- circuiting of the system. 11. The permitted amounts of surface area and/or volume have been provided. 12. Required drawdown devices are correctly sized and located per the approved plans. 13. All required design depths are provided. 14. All required parts of the system are provided, such as a vegetated shelf, a forebay, a vegetated filter, level spreader and a secondary BMP. 15. The required system dimensions are provided per the approved plans. 16. All components of the stormwater BMP are located in either recorded common areas, or recorded easements. cc: NCDENR-DWQ Regional Office Page 8of8 COASTAL SITE DESIGN, PC PO Box 4041 . Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 License # C-2710 May 7, 2014 Christine Nelson Express Review Permitting N.C. Department of Environment and Natural Resources Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Pond As -Built & Certification Courthouse Bay BEQ at Munro Road FYI I Courthouse Bay P 1251 & P 1254 CSD Project No. 11-0251 Stormwater Project No. SW8 120102 Dear Christine: Enclosed please find the following items for the referenced project: - original and one (1) copy of the Stormwater Pond As -Built Drawing - one (1) original Designer's Certification GENE BY: We appreciate your assistance in this matter. Please call if you require any additional information. Sincerely, Howard Resnik, PE Encl.: As noted above ` 1, y$}� 1.0Z 01 ',3vrv.YJi dwY� A.^n a R; � ti ¢ d i� -F•j Q— W i 1 Sdra'4 1rM n rr, 51 R.T ZOIOZI 8Ms ^Ara 3snowenoJ wid- Y� i a ! ❑ 2 g a ��Y�4 0 3 e y dd ` C „4 4 LL W*S❑mac n�i3v ❑ ❑ eyld� �a zY w a F k9 LL ° p.-e G�RSSh 2 .RgL� LL •1 s m x � p �I �a N 3 d 2012 COASTAL SITE DESIGN, PC PO Box 4041 Wiimington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 License # C-2710 January 30, 2012 Christine Nelson Express Review Permitting N.C. Department of Environment And Natural Resources Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Express Stormwater Submittal SW8 120102 Onslow County CSD Project No. 11-0251 Dear Christine: Enclosed please find the following items. - two (2) copies of sheets C-506,orifice size has been changed. Please call if you have any questions. Very truly yours, �k Rodney Wright Encl.: As noted above cc: Calibre Engineering R, Ef CEIV�I] JAN 3 0 2012 BY: Nelson, Christine From: Rodney Wright [rod ney@coastalsitedesig n. com] Sent: Friday, January 27, 2012 3:54 PM To: Nelson, Christine; Howard Resnik Contact Cc: Russell, Janet Subject: RE: Courthouse Bay BEQ I'll have the copies to you on Monday. Thanks and have a great weekend, Rodney From: Nelson, Christine mailto:christine.nelson ncdenr. ov] Sent: Friday, January 27, 2012 3:43 PM To: howard!@coastalsitedesign.com; Rodney Wright Cc: Russell, Janet Subject: Courthouse Bay BE=Q Howard/Rodney, I've pretty much completed my review of the Courthouse Bay BEQ project (SW8 120102) and the only thing I noticed was that the orifice size on the outlet structure detail was IDed as 3" instead of 2.7". If you can get me two copies of an updated sheet with the correct orifice size early next week, that should do it. Thanks! Christine Christine Nelson Environmental Engineer State Stormwater Program NC Division of Water Quality 127 Cardinal Drive Ext. Wilmington, NC 28405 Phone: 910-796-7323 Email correspondence to and from this address is subject to the North Carolina Public Records Low and may be disclosed to third parties unless the content is exempt by statute or other regulation. Nelson, Christine From: Nelson, Christine Sent: Thursday, January 19, 2012 1:48 PM To: 'Rodney Wright' Cc: Russell, Janet Subject: RE: CB revised info Rodney, Thank you for fixing those two sheets. I have swapped out the sheets. Christine Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Rodney Wright [maiito:rodne coastalsitedesi n.com Sent: Thursday, January 19, 2012 1:17 PM To: Nelson, Christine Subject: CB revised info Christine, Attached please find the revised narrative that removes the mention of infiltrating the difference of the 10 yr and 1 yr storm. Also attached are the revised calcs showing just the design storm being effectively infiltrated instead of the difference between the 10 and 1 yr storms. Thanks, Rodney Wright Engineering Tech Coastal Site Design, PC rodnev(a?coastalsitedesian.com Ph. 910-791-4441 Fax 910-791-1501 ***ANY DIGITAL INFORMATION IS PROVIDED FOR YOUR CONVENIENCE. NO CLAIM FOR ACCURACY IS MADE BY COASTAL SITE DESIGN, PC EXCEPT FOR SIGNED AND STAMPED DOCUMENTS. USER SHALL ASSUME ALL LIABILITY FOR USE AND/OR ALTERATION OF THIS DIGITAL PRODUCT.*** COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 License # C-2710 January 19, 2012 Christine Nelson Express Review Permitting N.C. Department of Environment And Natural Resources Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405 Re: Express Stormwater Submittal BEQ at Intersection of Command and Munro Onslow County CSD Project No.' 11-0251 Dear Christine: Enclosed please find the following items. one (1 copy of the Stormwater Management Calculations two (2) copies of sheets C-130, C-506,C507-508 two (2) copies project limits, impervious dimensions and drainage area maps Original stormwater application Original O & M for wet basin A - Check for $4,000 check # 64612 - wet basin supplements for pond A - two (2) copies of the grading sheets- - VFILS supplement - Original O & M for VS/LS Please call if you have any questions. Very truly yours, Rodneyyght Encl.. As noted above JAN 1 a 2012 i cc: Calibre Engineering STORMWATER MANAGEMENT CALCULATIONS For COURTHOUSE BAY P1251, P1254 BEQ AT INTERSECTION OF COMMAND AND MUNRO PREPARED FOR Deputy Public Works Officer 1005 Michael Road MCB Camp Lejeune 28547 Prepared by: COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28408 Phone: 910 791-4441 Fax: 910 7911,1501 License k,C-2710 \\\1�C'A If 0 Q-925483 r':�� F� Rom, t�r� jr� %off �G R CEIVEI;� A Resnik, P.E. JAN 19 2012 (f9/Iz BY: COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 License # C-2710 FOR STORMWATER EXPRESS REVIEW January 15, 2012 PROJECT NAME: Courthouse Bay P1251 / BEQ located at intersection of Munro Road and Command Drive MCB Camp Lejeune, NC Onslow County PROJECT DESCRIPTION: The project area for this development is 10.14 acres with 12.83 acres of land disturbance. There are no wetlands located within the project limits. This project includes the construction of barracks, basketball courts, and a parking deck to be located at Courthouse Bay. The owner is the United States Marine Corps. Water and sewer will be provided by Camp Lejeune. Stormwater from the site drains to Courthouse Bay, classified as SA;HQW waters located in the White Oak River Basin (Index # 19- 36). The project will be high density utilizing a wet basin designed for 90% TSS removal and will store the volume from the difference of the 1 year pre/post storm event. The discharge from the pond will flow into a level spreader & filter strip area designed to provide effective infiltration for the I yr 24 hr storm event. Stormwater will be conveyed to the pond using an underground stormwater collection system and open conveyance ditches. Proposed impervious for the site is 53%. The site will have direct access to Munro Road. SHWT and infiltration tests have been performed at the proposed locations ofthe wet basin and filter strip, and the permanent pool elevation of the wet basin has been set above the SHWT elevation. PROJECT BMP: high density wet pond with level spreader / filter strip STORMWATER ENGINEER/CONSULTANT: Coastal Site Design, PC PO Box 4041 7-BY: Wilmington, NC 28406 JAN 1Rodney Wright rdney@coastalsitedesign.com 910 7914441 office 910 791 1501 fax , r r , PROJECT DATA: TOTAL SITE Existing Site Data (areas within property boundgyh wetland area 0.00 sf (0.00 acres) upland area 441,826 sf (10.14 acres) Total site area 441,826 sf (10.14 acres) Proposed Site _Data: Buildings 128,595 sf (2.95 acres) Proposed asphalt 23,108 sf (0.53 acres) sidewalks 24,979 sf (0.57 acres) fire road 44,002 sf (1.0 1 acres) future 1,000 sf (0.02 acres) recreation 12,480 sf (0.29 acres) Total proposed impervious area 234,164 sf (5.38 acres) Soil Types: Abbreviation Type and Description Hydrologic Group Area Bab Baymeade A 10.14 ac (See attached soils map and pages 132 of Table 15, "Physical and Chemical Properties of the Soils") RECEIVED JAN 1 9 2012 BY: POND A CALCULATIONS PRE -DEVELOPED CONDITIONS FOR POND (see hydrograph summary and reports): Pre-dev. to pond CN Pre Developed = 45 (SCS) composite value determined as follows: +/- 441,826 sf of soils area A, woods, poor condition (CN = 45) Area = 441,826 sf or 10.14 acres Hydraulic Length = 880 ft Basin Slope = 1.8% Qmax for pre-dev 1-yr/24-hr storm = 0.199 cfs POST -DEVELOPED CONDITIONS FOR POND (see hydrograph summary and reports): Post-dev,_to pond CN Pre Developed = 70 (SCS) composite value determined as follows: +l- 234,164 sf of impervious surface (CN = 98) +1- 207,662 sf of soils area A, open space, good condition (CN = 39) ((234,164 x 98) + (207,662 x 39)) / 441,826 = 70.3 USED CN = 70 Area = 441,826 sf or 10.14 acres Hydraulic Length = 700 ft Basin Slope = 0.80% Qmax for post-dev 1-yr/24-hr storm = 7.30 cfs Routed site — areas draining to pond routed through pond and filter strip (see hydrograph summary & reports): Qmax for post route 1-yr/24-hr storm = 0.199 SUMMARY: Qmax for routed post-dev 1-yr/24-hr storm = 0.199 efs < =0.199 cfs....0.K RECEIVE JAN 1 9 2ai2 BY: t I , WET DETENTION BASIN CALCULATIONS DETERMINE IMPERVIOUS PERCENTAGE area to basin = 441,826 sf 10.14 acres . buildings = 128,595 sf 2.95 acres paved parking areas = 23,108 sf 0.53 acres sidewalks = 24,979 sf 0.57 acres fire road = 44,002 sf 1.01 acres future = 1,000 sf 0.02 acres rec = 12,480 sf 0.29 acres total impervious surface = 234,164 sf 5.38 acres total non -impervious surface = 207,662 sf 4.77 acres percent imp. = 53.0 % DETERMINE REQUIRED SURFACE AREA from 90% TSS Removal Chart: ® depth = 4 ft im % SAIDA 50 4.3 53.0 x 60 5.3 x = 4.60 minimum surface area = 0.0460 x = 20,324 sf surface area provided = 25,515 sf ® elevation 24.5 1.5" VOLUME DETERMINATION: DETERMINE RUNOFF COEFFICIENT (Rv) = 53.0 percent impervious Rv = ? (runoff coefficient, inches per inch) Rv = 0.05 + 0.009 (1) Rv = 0.53 irYn DETERMINE VOLUME design storm = 1.5 inch Rv = 0.53 infin drainage area = 10.14 acres volume = ? volume = (design storm)(Rv)(drainage area) volume = 0.7 acre-ft volume = 29,263 of of required storage volume 441,826 sf R-ECEAVED JAN 1 9 2012 BY COASTAL SITE DESIGN, PC PO BOX 4041 WILMINGTON, NC 28406 ae 1 YR 24 HR PRE/POST VOLUME: Pre -development: Rv = 0.05 + 0.9 * (0 ac 110.14 ac) pre Rv = 0.05 Post -development: Rv = 0.05 + 0.9 * (5.38 ac 110.14 ac) post Rv = 0.53 DETERMINE VOLUME 24 hr rainfaill intensity (1) 3.83 inch Rv (post - pre) = 0.48 in/in drainage area = 10.14 acres volume = ? volume = 3630 x I x (Rv post - Rv pre) x drainage area volume = 67,668 cf of required storage volume WET DETENTION BASIN STAGE -STORAGE TABLE: ELEVATION AREA (FT) (SF) 20 14,673 21 16,285 22 17,953 23 19,677 24 21,458 Bottom Shelf 24.5 22,370 PP 25 25,515 Top Shelf 25.5 28,810 26 29,830 State Storage 27 31,913 27.3 32,549 28 34,053 28.5 35,143 volume at permanent pool (elev. 25.0) = PREIPOST storage volume provided (elev. 27.3) total volume of basin = surface area at bottom of 10:1 shelf (24.5) = volume at bottom of 10:1 shelf = surface area at top of 10:1 shelf (25.5) = volume at top of 10:1 shelf minimum forebay volume INCREMENTAL VOLUME STORAGE (cf) (cf) 15,479 17,119 18,815 20,568 10,957 11,971 13,581 14,660 30,872 9,669 23,311 34,598 94,909 cf 68,782 Cf 221,600 cf 22,370 sf 82,938 cf 28,810 sf 108,490 Cf 18,982 Cf 13,581 28,241 59,113 68,782 92,093 126,691 RECEIVED JAIL 1 9 2012 COASTAL SITE DESIGN, PC PO BOX 4041 WILMINGTON, NC 28406 AVERAGE POND DEPTH AREA BOTTOM SHELF (ABS) = 22,370 SF AREA PP (APP) = 25,515 SF AREA BOTTOM POND (ABP) = 14,673 SF DEPTH = 24.5-20 4.5 ft [0.25 X (1 + (ABS/APP))]+[((ABS+ABP)/2) X (DEPTH/ABS)] AVERAGE DEPTH = 4.20 It FOREBAY STAGE -STORAGE TABLE: INCREMENTAL ELEVATION AREA VOLUME STORAGE (Fr) (SF) (Cf) (cf) 20 1,936 - 21 2,579 2,258 2,258 22 3,278 2,929 5,187 23 4,034 3,656 8,843 24 4,846 4,440 13,283 25 6,801 5,824 19,107 forebay volume provided = 19,107• Cf STAGE - DISCHARGE TABLE: size of orifice (in) = 2.70 elevation of orifice = 25.00 crest length of weir cut (ft) = 0.00 elevation of weir cut = - crest length of grates (sf) = 4.0 elevation of grates = 27.3 crest length of spillway (ft) = 30.0 elevation of spillway = 28.0 ELEVATION 2.7" PVC WEIR GRATES SPILLWAY TOTAL (ft) (cts) (Cfs) (Cfs) (Cfs) (Cfs) 25 0.00 - 26 0.19 - 27 0.27 - 27.3 0.29 no weir cut 28 0.33 no weir cut 28.5 0.36 no weir cut PVC DRAW DOWN Orifice size = 2.70 in Normal Pool Storage Elev. = 25.00 1 year pre/post storage Elev. = 27.3 0.19 0.27 0.00 0.29 7.73 8.06 17.35 31.82 49.53 Orifice coefficient (C) = 0.6 Average head from 1 YEAR storage to orifice (h) = (27.3 - 25.0) /3 = Orifice cross sectional area (A) = pi x r^2 = 3.14 x (N12)A2 = Acceleration due to gravity (g) Q=CA (2ghrl/2 = 0.6 x 0.04906 x (2x32.2x0.77)^1/2 = 68,782 / 0.20728 = 409,636 seconds = 0.77 It 0.03974 sf 32.2 ft/s^2 0.16791 cfs 4.74 days - �� IVE" 3aN 1 9 za3z j3y: COASTAL SITE DESIGN, PC PO BOX 4041 WILMINGTON, NG 28406 EFFECTIVE INFILTRATION 1 VF CALCULATIONS VOLUME FROM DESIGN STORM: 1 YR PRE/POST Volume = 67,668 cf REQUIRED FILTER STRIP AREA: DETERMINE AREA FOR EFFECTIVE INFILTRATION K= 2.75 IN/HR (AVG OF BORINGS 111,11113, 13) T = 4.74 DAYS V = 67,668 CIF (1 Yr prelpost volume) A= ? A = V 1(2KT) A = 2,596 SF NEEDED FOR EFFECTIVE INFILTRATION A = 4,000 SF PROVIDED FOR FILTER STRIP FILTER STRIP EFFECTIVE INFILTRATION: linear infiltration rate = 2.75 in/hr — 0.000064 ft/sec Filter Strip bottom area = 4,000 sf 3-d infiltration rate = 0.26 cflsec EFFECTIVE INFILTRATION CHECK: DWQ Discharge Rate from 1 yr 24 hr = 0.16791 cfs (see PVC drawdown calc previous page) SCS Peak Discharge Rate from 1 yr 24 hr = 0.199 cfs (see Hydroflow SCS summary report) Filler Strip Infiltration Rate = 0.26 cfs 0.199 > 0.16791 Use 0.199 to demonstrate Effective Infiltration 0.26 a 0.199 Design Storm Effectively Infiltrates LEVEL SPREADER CALCULATION: 10 YR Discharge = 3.39 cfs (Routed flow from pond, see hydrographs) 10 FT per CFS of Level Spreader Required = 33.9 FT concrete Level Spreader Required 40 FT concrete Level Spreader Specified i TX. FD i i JAN 19 2012 JBY: COASTAL SITE DESIGN, PC PO BOX 4041 WILMINGTON, NC 28406 Hydrograph Summary Re po -Hydraflow Hydrographs Extension for AutoCADM Civil 3D® 2012 by Autodesk, Inc. v9 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 0.199 2 842 5,155 --- --- Pre Dev 2 SCS Runoff 7.302 2 748 44,307 ---- ---- Post Dev 3 Reservoir 0.199 2 1450 39,888 2 26.26. 36,222 Routed 5 Rational 12.69 1 5 3,808 ---- ----- ----- PreDev 6 Rational 38.08 1 5 11,424 — -- Post Dev 7 Reservoir 0.125 1 10 9,292 6 25.42 11,387 Routed RECEIVED JAN 1 9 2012 BY: C8_Pond.gpw Return Period: 1 Year Friday, 00 13, 2012 Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3136 2012 by Autodesk, Inc. vE Hyd. No. 1 Pre_Dev Hydrograph type = SCS Runoff Storm frequency = 1 yrs Time interval = 2 min Drainage area = 10.140 ac Basin Slope = 1.8 % Tc method = LAG Total precip. = 3.83 in Storm duration = 24 hrs Friday, 00 13, 2012 Peak discharge = 0.199 cfs Time to peak = 842 min Hyd. volume = 5,155 cult Curve number = 45 Hydraulic length = 880 ft Time of conc. (Tc) = 54.32 min Distribution = Type III Shape factor = 484 Pre Dev Q (cfs) Hyd. No. 1 -- 1 Year Q (cfs) 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 000 0.50 0.45 0.40 0.35 0.30 . 0.25 0.20 0.15 0.10 0.05 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Hyd No. 1 ZRC-EI.VED Time (min) JAN 1 9 2012 BY: I , Hydrograph Report Hydraflow Hydrographs Extension for AutoCAO® Civil 3DO 2012 by Aulodesk, Inc. v9 Friday, 00 13. 2012 Hyd. No. 2 Post_Dev Hydrograph type = SCS Runoff Peak discharge = 7.302 cfs Storm frequency = 1 yrs Time to peak = 748 min Time interval = 2 min Hyd. volume = 44,307 tuft Drainage area = 10.140 ac Curve number = 70" Basin Slope = 0.8 % Hydraulic length = 700 ft Tc method = LAG Time of cone. (Tc) = 35.71 min Total precip. = 3.83 in Distribution = Type III Storm duration = 24 hrs Shape factor = 484 Composite (Area/CN) = [(5.380 x 98) + (4.760 x 39)] 110.140 Q (cfs) 8.00 AM 4.00 Paild Post_Dev Hyd. No. 2 --1 Year ` 120 240 360 480 600 720 840 Hyd No. 2 Q (cfs) 8.00 4.00 2.00 0.00 960 1080 1200 1320 1440 1560 R CIE' �V D Time (min) BAN 1 9 2012 BY: Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3D® 2012 by Autodesk, Inc. v9 Friday, 00 13, 2012 Hyd. No. 3 Routed Hydrograph type = Reservoir Peak discharge = 0.199 cfs Storm frequency = 1 yrs Time to peak = 1450 min Time interval = 2 min Hyd. volume = 39,888 cuft Inflow hyd. No. = 2 -Post Dev Max. Elevation = 26.26 ft Reservoir name = Pond A Max. Storage = 36,222 cult Storage Indication method used. Routed Q (cfs) Hyd. No. 3 —1 Year Q (cfs) 8.00 8.00 6.00 6.00 4,00 4.00 2.00 2.00 n nn 0 00 0 600 1200 1800 2400 3000 3600 4200' 4800 5400 Hyd No. 3 Hyd No. 2 [MLE01 Total storage used = 36,222 tuft RECEIVED JAN 1 9 2012 RV 6000 Time (min) Hydrograph Repor# Hydraflow Hydrographs Extension for AutoCADO Civil 3DO 2012 by Autodesk, Inc. ve. Hyd. No. 5 Pre Dev Hydrograph type = Rational Storm frequency = 1 yrs Time interval = 1 min Drainage area = 10.140 ac Intensity = 6.259 in/hr OF Curve = wilmington_2008.IDF Q (cfs) 14.00 12.00 10.00 B.00 6.00 4.00 2.00 0.00 y 0 1 2 ---- Hyd No, 5 Friday, 00 13, 2012 Peak discharge = 12.69 cfs Time to peak = 5 min Hyd. volume = 3,808 cuft Runoff coeff. = 0.2 Tc by User = 5.00 min Asc/Rec limb fact = 1/1 Q WS) 14.00 12.00 10.00 8.00 6.00 4.00 2.00 -N o.aa 3 4 5 6 7 8 9 10 Time {min} Rom' C IVED JAN 1 9 2012 BY: Pre_Dev Hyd. No. 5 --1 Year Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 31M 2012 by Autodesk, Inc. of Hyd. No. 6 Post Dev Hydrograph type = Rational Storm frequency = 1 yrs Time interval = 1 min Drainage area = 10.140 ac Intensity = 6.259 in/hr. OF Curve = wilmington_2008.IDF Composite (Area1C) = [(5.380 x 0.95) + (4.760 x 0.20)] / 10,140 Q (cfs) 40.00 30.00 10.00 0.00 -i ' 0 1 Hyd No. 6 Friday, 00 13, 2012 Peak discharge = 38.08 cfs Time to peak = 5 min Hyd. volume = 11,424 cult Runoff coeff. = 0.6*1 Tc by User = 5.00 min Asc/Rec limb fact = 1 /1 Post Dev Hyd. No. 6 -- 1 Year 2 3 4 5 6 Q (cfs) 40.00 30.00 20.00 10.00 -- I X 0.00 7 8 9 10 RECEIVED Time (min) JAN 1 9 Z012 BY: Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 30® 2012 by Autodesk, Inc. v9 Hyd. No. 7 Routed Hydrograph type = Reservoir Peak discharge Storm frequency = 1 yrs Time to peak Time interval = 1 min Hyd. volume Inflow hyd. No. = 6 - Post Dev Max. Elevation Reservoir name = Pond A Max. Storage Storage Indication method used. Q (cfs) 40.00 30.00 20.00 10.00 0.00 -5 0 300 600 Hyd No. 7 Routed Hyd. No. 7 -- 1 Year 900 1200 Hyd No. 6 Friday, 00 13, 2012 = 0.125 cfs = 10 min = 9,292 cult = 25.42 ft = 11,387 tuft Q (cfs) 40.00 30.00 20.00 10.00 1 1 0.00 1500 1800 2100 2400 2700 3000 Total storage used = 11,387 cult Time (min) RECEIVED JAIV 1 9 2012 ,BY: Pond Report Hydraflow Hydrographs Extension for AutoCADO Civil 3DO 2012 by Autodesk, Inc. v9 Pond No. f - Pond A Pond Data Contours -User-defined contour areas. Conic method used for volume calculation. Begining Elevation = 25.00 ft Stage 1 Storage Table Stage (ft) Elevation (ft) Contour area (sgft) Incr. Storage (cult) Total storage (cuft) 0,00 25.00 25,515 0 0 0.50 25.50 28,757 13,559 13,559 1.00 26.00 29,762 14,628 28,186 2.00 27.00 31,813 30,779 58,965 2.30 27.30 32,440 9,637 68,602 3.00 28.00 33,922 23,222 91,824 3.50 28.50 34,997 17,227 109,052 Culvert 1 Orifice Structures Weir Structures [A] [Bl [C] [PrfRsr] [Al [gl Rise (in) = 24.00 2.70 0.00 0.00 Crest Len (ft) = 4.00 0.00 Span (in) = 24.00 2.70 0,00 0.00 Crest El. (ft) = 27.30 0.00 No. Barrels = 1 1 0 0 Weir CoeH. = 3.33 3.33 Invert El. (ft) = 25.00 25.00 0.00 0.00 Weir Type = 1 Rect Length (ft) = 37.00 1.00 0.00 0,00 Multi -Stage = Yes Yes Slope (%) = 2.70 0.00 0.00 n/a N-Value = .013 .013 .013 n/a Orifice Coeff. = 0.60 0.60 0.60 0.60 Exf l.(in/hr) = 0,000 (by Wet area) MultlStage = n1a Yes No No TW Elev. (ft) = 0.00 Stage (ft) 4.00 3.00 2.00 0.00 -t--I- 0.00 3,00 Total Q Friday, 00 13, 2012 [C] [D] 30.00 0.00 28.00 0.00 2,60 3.33 Broad --- No No Note: Culvert/Orifice outflows are analyzed under inlet (ic) and outlet (oc) control. weir risers checked for orifice conditions (ic) and submergence (a). Stage I Discharge 6.00 9.00 12.00 15.00 18.00 21.00 24.00 27.00 - 30,00 33.00 . CM .BAN 1 9 2012 RV. Elev (ft) 29-00 28.00 27.00 26.00 -' 25.00 36.00 Discharge (cfs) Hydrograph Summary ReporlydraflowHydrographsExtension for AuloCAD®Civil 3DOD2012byAutodesk,Inc. v9 Hyd. No. Hydrograph type (origin) Peak flow (cfs) Time interval (min) Time to Peak (min) Hyd. volume (cuft) Inflow hyd(s) Maximum elevation (ft) Total strge used (cuft) Hydrograph Description 1 SCS Runoff 5.308 2 768 49.022 -- --- ----- Pre Dev 2 SCS Runoff 24.19 2 744 138,355 ------ ----- Post Dev 3 Reservoir 3.395 2 838 121,232 2 27,68 81,209 Routed 5 Rational 19.65 1 5 5,894 ----- — — Pre Dev 6 Rational 58.94 1 5 17,682 ----- Post Dev 7 Reservoir 0.164 1 10 14,823 6 25.64 17,629 Routed RECEIVED JAN 1 9 201z BY: CB_Pond.gpw Return Period: 10 Year Friday, 00 13, 2012 Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 3DO2012 by Autodesk, Inc. A Hyd. No. 1 Pre Dev Hydrograph type = SCS Runoff Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 2 min Hyd. volume Drainage area = 10.140 ac Curve number Basin Slope = 1.8 % Hydraulic length Tc method = LAG Time of conc. (Tc) Total precip. = 7.22 in Distribution Storm duration = 24 hrs Shape factor Q (cfs) 6.00 5.00 4.00 3.00 2.00 1.00 Pre_Dev Hyd. No. 1 -- 10 Year Friday, 00 13, 2012 = 5.308 cfs = 768 min = 49,022 cuft = 45 = 880 ft = 54.32 min = Type III 484 Q (cfs) 6.00 5.00 4.00 3.00 2.00 1.00 0.0a 0.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 Hyd No. 1 RZ. ECEl TED Time (min) JAN 1 9 20i2 BY: Hydrograph Report Hydraflow Hydrographs Extension for AutoCADO Civil 3138 2012 by Autodesk, Inc. v9 Friday, 00 13, 2012 Hyd. No. 2 Post Dev Hydrograph type = SCS Runoff Peak discharge = 24.19 cfs Storm frequency = 10 yrs Time to peak = 744 min Time interval = 2 min Hyd. volume = 138,355 cuft Drainage area = 10.140 ac Curve number = 70* Basin Slope = 0.8 % Hydraulic length = 700 ft Tc method = LAG Time of conc. (Tc) = 35.71 min Total precip. = 7.22 in Distribution = Type III Storm duration = 24 hrs Shape factor = .484 Composite (Area1CN) = ((5.380 x 98) + (4.760 x 39)) / 10.140 Q (cfs) 28.00 24.00 20.00 16.00 12.00 8.00 4.00 Post_Dev Hyd. No. 2 -- 10 Year Q (cfs) 2&00 24.00 20.00 16.00 12.00 M 4.00 0 120 240 360 480 600 720 840 960 1080 1200 1320 1440 1560 -- Hyd No. 2 RECEI r D Time (min) JAN 1 9 282 BY: Hydrograph Report Hydranow Hydrographs Extension for AutoCAD® Civil 3D® 2012 by Autodesk, Inc. v9 Hyd. No. 3 Routed Hydrograph type = Reservoir Peak discharge Storm frequency = 10 yrs Time to peak Time interval = 2 min Hyd. volume Inflow hyd. No. = 2 - Post_Dev Max. Elevation Reservoir name = Pond A Max. Storage Storage Indication method used. Q (cfs) 28.00 24.00 20.00 16.00 12.00 8.00 4.00 Routed Hyd. No. 3 -- 10 Year Friday, 00 13, 2012 = 3.395 cfs = 838 min = 121,232 cuft = 27.68 ft = 81,209 cuft a (cfs) 28.00 24.00 20.00 12.00 4.00 0.00 L ' L ` 0.00 0 600 1200 1800 2400 3000 3600 4200 4800 5400 6000 Time {min) Ti Hyd No. 3 - Hyd No. 2 U[.11-E Total storage used = 81,209 cuft 7 7][[' �� N —' V D JAN. 1 9 2012 ]BY - Hydrograph Report HydraFlow Hydrographs Extension for AutoCAD® Civil 3D® 2012 by Autodesk, Inc. vc Hyd. No. 5 Pre_Dev Hydrograph type = Rational Storm frequency = 10 yrs Time interval = 1 min Drainage area = 10.140 ac Intensity = 9.688 inlhr OF Curve = wilmington_2008.IDF Q (cfs) 21.00 18.00 15.00 12.00 9.00 6.00 3.00 0 00 0 1 2 Hyd No. 5 Friday, 00 13, 2012 Peak discharge = 19.65 cfs Time to peak = 5 min Hyd. volume = 5,894 cult Runoff coeff. = 0.2 Tc by User = 5.00 min Asc/Rec limb fact = 111 Pre Dev Hyd. No. 5 -- 10 Year Q (cfs) 21.00 18.00 15.00 12.00 9.00 6.00 3.00 0.00 3 4 5 6 7 8 9 10 RECEIVED Time (min) JAB! 1 9 2012 BY: Hydrograph Report Hydraflow Hydrographs Extension for AutoCAD® Civil 31® 2012 by Autodesk, Inc. v9 Friday, 00 13, 2012 Hyd. No. 6 Post_Dev Hydrograph type = Rational Peak discharge = 58.94 cfs Storm frequency = 10 yrs Time to peak = 5 min Time interval = 1 min Hyd. volume = 17,682 tuft Drainage area = 10.140 ac Runoff coeff. = 0.6* Intensity = 9.688 inlhr Tc by User = 5.00 min OF Curve = wilmington-2008.IDF Asc/Rec limb fact = 111 " Composite (Area/C) = ((5.380 x 0.95) + (4.760 x 0.20)] 110.140 Q (cfs) 60.00 50.00 40.00 20.00 10.00 0.00 0 1 Hyd No. 6 Post Dev Hyd. No. 6 —10 Year 2 3 4 5 6 Q (cfs) 60.00 50.00 40.00 30.00 20.00 31 0.00 10 Time (min) Hydrograph Report Hydraflow Hydrograghs Extension forAutoCAD® Civil 3D920i2 by Autodesk, Inc. A Friday, 00 13, 2012 Hyd. No. 7 Routed ' Hydrograph type = Reservoir Peak discharge = 0.164 cfs Storm frequency = 10 yrs Time to peak = 10 min Time interval = 1 min Hyd. volume = 14,823 cuft Inflow hyd. No. = 6 - Post_Dev Max. Elevation = 25.64 ft Reservoir name = Pond A Max. Storage = 17,629 cuft Storage Indication method used Q (cfs) 60.00 50.00 40.00 30.00 20.00 10.00 Routed Hyd. No. 7 —10 Year a (cfs) 60.00 50.00" 30.00 20.00 10.00 0 300 600 900 1200 1500 1800 2100 2400 2700 -3000 _ �---- Hyd No. 7--W-�-- Hyd No. 6 I[_C.TCJ_:.CL1 Total storage used = 17,629 tuft Time (min) RECEIVED JAN 1 9 2012 BY: Pond Report Hydraflow Hydrographs Extension for AutoCADV Civil 3DO 2012 by Autodesk, Inc. v9 Friday, 00 13, 2012 Pond No. 1 - Pond A Pond Data Contours -User-defined contour areas. Conic method used for volume calculation. Begining Elevation = 25.00 ft Stage 1 Storage Table Stage (ft) Elevation (ft) Contour area (sqft) Incr. Storage (tuft) Total storage (cult) 0.00 25.00 25,515 0 0 0,50 25.50 28,757 13,559 13,559 1.00 26.00 29,762 14,628 28,186 2.00 27.00 31,813 30,779 58,965 2.30 27.30 32,440 9,637 68,602 3.00 28.00 33,922 23,222 91,824 3.50 28.50 34,997 17,227 109,052 Culvert 1 Orifice Structures Weir Structures (A] [B] [C] [PrfRsr] [A] [fa] [Cl [D] Rise (In) = 24.00 2.70 0.00 0.00 Crest Len (ft) = 4.00 0.00 30.00 0.00 Span (in) = 24.00 2.70 0.00 0.00 Crest El. (ft) = 27.30 0.00 28.00 0.00 No. Barrels = 1 1 0 0 Weir Coeff. = 3.33 3.33 2.60 3.33 Invert El. (ft) = 25.00 25-00 0.00 0.00 Weir Type = 1 Rect Broad --- Length (ft) = 37.00 1,00 OM 0,00 Multi -Stage = Yes Yes No No Slope (%) = 2.70 0.00 0.00 nla N-Value = .013 .013 .013 nla Orifice Coeff. = 0.60 0.60 0.60 0.60 ExfiL(inthr) = 0,000 (by Wet area) Multi -Stage = n1a Yes No No TW Elev. (ft) = 0.00 Stage (ft) 4.00 3.00 2.00 1.00 l 0.00 T ' 0.00 3.00 Total 0 Note: CulverUQririce outnaws are anatyzed under inlet (ic) and outlet (oc) contmt, Weir risers checked for orifice conditions (ic) and submargence (3) Stage 1 Discharge 6.00 9.00 12.00 15.00 18.00 21.00 24.00 27.00 30.00 33.00 JAN 1 9 2012 Elev (ft) 29.00 28.00 27.00 26.00 -L- 25.00 36.00 Discharge (cfs) i•�x �� t � (.,� .q '.,y � '.� � IVY"� '��":. �'4r�u' f !� I .kLL'�• s, 11 ,�.' I ��., � ,fir` �" :rsy � • �k �' S "Siftly n.� y � :.v r� S J� r kr f 'm Y �I`j',��7 g� � a � r. M �r. .1 M �y� I � � '. �r, � I •^ 4'}k ,}�'. � � �. -dam. S •�'^'r � .� � i i k �. �' � - Wr�,v' `,� L � r a.. �.� a,x♦i r: 'fi. f+i1 yF , ' ! �,T �` '�!°'/ k' Ire°' 1T tY yt 41 132 TABLE 15.--PHYSICAL AND CHEMICAL PROPERTIES OF THE SOILS Sail Survey (The symbol < means leas than; > means more than. Entries under "Erosion factors--T" apply to the entire profile. Entries under "Organic matter" apply only to the surface layer. Absence of an entry indicates that data were not available or were not estimated) I I I 1 i I 1 I Erosion I Soil name and IDepthi Clay I Moist (Permeability IAvailablel Soil IShrink-swell I factors I Organic map symbol I I I bulk I I water Ireactionl potential I I I matter I ! I density I !capacity I I I K I T I I In 1 Pct I g/cc I In/hr I In/in I PH I 1 I I Pct AnB--------------1 0-131 1-12 11.35-1.551 2.0-6.0 10.05-0.1014.5-6.5 ILow---------- 10.101 5 1 0-2 Aipin 113-481 1-7 11.40-1.551 6.0-20.0 10.03-0.0914.5-6.5 ILow---------- 10.101 1 148-801 I I 5-8 11.45-1.651 I ! 2.0-6.0 10.06-0.0914.5-6.5 I ILow---------- 10.101 1 AuB-------------- 1 0-241 2-10 11.60-1.701 >6.0 I 10.04-0.0914.5-6.5 I I I ILow---------- 10.101 I 5 1 .5-1 Autryville 124-381 10-25 11.40-1.601 2.0-6.0 10.08-0.1314.5-5.5 ILaw---------- 10.101 1 138-531 2-8 11.60-1.701 >6.0 10.03-0.0814.5-5.5 ILow---------- 10.101 1 153-991 I I 10-35 11.40-1.601 I 0.6-2.0 10.10-0.1514.5-5.5 Mow ---------- I0.171 1 BaB-------------- 1 0-301 0-8 I 11.60-1.751 6.0-20 I I 10.02-0.0614.5-6.5 I I I ILow ---------- 10.101 1 5 1 .5-1 Baymeade 130-561 8-26 11.45-1.601 2.0-6.0 10.10-0.1414.5-6.5 ILow---------- 10.101 1 156-801 I I 0-12 11.60-1.751 I 6.0-20 10.02-0.1014.5-6.5 ILow---------- 10.101 1 BmB" : I I I 1 I I I I I I I l I I I I I Baymeade -------- 1 0-301 0-8 11.60-1.751 6.0-20 10.02-0.0614.5-6.5 ILow-------- =-10.101 5 1 .5-1 130-561 8-26 11.45-1.601 2.0-6.0 10.10-0.1414.5-6.5 ILow---------- 10.101 1 156-801 I I 0-12 11.60-1.751 I 6.0-20 10.02-0.1014.5-6.5 ILow---------- 10.101 1 Urban land. I 1 I I I I E I E I I I I I I I I I I Bo --------------- 1 0-8 1 30-60 I I 11.20-1.40[ 0.06-0.2 I I 10.02-0.0616.1-8.4 I 1 I (High --------- 10.291 1 5 1 5-25 Bohicket 1 8-381 35-60 11.30-1.601 <0.06 10.02-0.0616.1-8.4 ]High --------- 10.241 1 136-601 --- I --- I --- I --- I--- I-------------I----I I l I Ca---------------1 0-651 5-12 I I 11.45-1.601 >6.0 I I 10.02-0.1015.6-8.4 I I I ILow---------- 10.151 I 5 1 .5-2 Carteret I I I I I I I I I I I Cc --------------- 1 0-721 0-3 I I 11.60-1.701 >20 I ! 10.01-0.0315.6-7.8 I I I ILow---------- 10.101 I 5 1 <.5 Corolla I I I I I I I I I I I I CrB, CrC--------- 1 0-8 1 6-20 I I 11.30-1.551 0.6-2.D I I 10.12-0.1813.6-6.5 I I I 1Low---------- 10.371 I 5 1 .5-2 Craven 1 8-481 35-60 11.30-1.451 0.06-0.2 10.12-0.1513.6-5.5 IMaderate----- 10.321 1 148-801 • I I 5-35 11.35-1.601 I 0.2-6.0 10.08-0.1413.6-5.5 ILow---------- 10.321 1 Ct--------------- 1 0-341 0.-0. I ID.40-0.651 0.06-6.0 I I 10.35-0.45 <4.5 I I I I I ILow---------- 1---- 1--- 1 25-60 Croatan 134-401 8-20 11.40-1.601 0.2-6.0 10.10-0.1513.6-6.5 ILow---------- I ---- 1 1 140-701 10-35 11.40-1.601 0.2-2.0 10.12-0.2013.6-6.5 ILow---------- 1----1 1 170-001 --- I --- I --- I --- I--- I -------------I- I I Da --------------- 1 0-4 1 --- I I 10.25-0.401 0.6-2.0 I I 10.25-0.5013.6-4.4 I I I I ! I--- 1 I Dorovan 1 4-901 --- 10.35-0.551 0.6-2.0 10.25-0.5013.6-4.4 1 ------------- I ---- 1 1 180-991 I I 5-20 11.40-1.651 I I 6.0-20 10.05-0.0814.5-5.5 ILow---------- I ---- I I Dc --------------- 1 0-601 0-4 11.60-1.701 >20 I I 10.02-0.0513.6-8.4 I i I ILow---------- 10.101 I 5 1 .5-1 Duckaton 1 I I I I I I I I I I I F'oA-------------- 1 0-8 1 5-12 I I 11.20-1.401 6.0-20 I I 10.05-0.1014.5-6.5 I I E ILow---------- 10.151 I 5 1 .5-2 Foreston 1 8-701 10-18 11.20-1.401 2.D-6.0 10.09-0.1314.5-5.5 ILow---------- 10.101 1 170-801 I 4-12 11.30-1.601 I 6.D-20 10.03-0.1014.5-5.5 ILow---------- 10.101 1 GoA-------------- 1 0-131 5-15 I 11.40-1.601 2.0-6.0 I I 10.08-0.1214.5-6.0 I I I ILow---------- 10.201 I 5 1 .5-2 Goldsboro 113-801 1 1 18-30 11.30-1.501 1 1 0.6-2.0 10.11-0.1514.5-5.5 1 1 ILow----------- 10.241 1 1 1 1 1 J See footnote at and of table. C EI VED JAN 1 9 2012 BY: POINT PRECIPITATION FREQUENCY ESTIMATES FROM NOAA ATLAS 14 WR MINGTON W80 AIRPORT, NORTH CAROU NA (31945n 34160 N 77.906I W 26 fat �am'lmClpiladorFra 7 Aft ailm thodlea 9 NO" Ago 14, volume 2. Vmdm 3 oxBamdgD. B.LkT.Pang6akILYftand 0.R&w NOAA, NAWW Wood= Barrloti 89-lpft M"� M Bare Ts Fab S 2001 lion Fstbutes ARP I 1It aes Li fa I .5 .83 1.041.431.78 10 79 26 .83 .54 .13 .93 7q 9.97 11.0013.76 16.5 2 .62 TTA 1.72 15 73 38 .% .63 3.49 . 21 .14 .02 10.68 13.08 I6 26 39.45 S .72 .47., 09 67, 50 .3-4 S.11 .02 7.04 Bb 98 94 I3.01 15. 1919 75 10 0.81 1.29 I.64 .08 .17 5.19 .14 22 39 28 1 11 14.95 17.83 1.71 38 25 . 0.91 1. I. 73 .64 73 .17 45 .69 A8 10.4 1139 I17 .9717.70 .78 .09 .91 .58 138 Oi .08 .49 .06 .57 .09 10.73 127E 13 14.66 15.93 19 96 .14 .75 1.65 100 1. 1.71 16 f 33 SS .05 .15. .84 f0 26 10.68 12.4 1261 1430 1S 1& 17,93 7 .57 .48 38 7.1 200 1.1 1.83 I4.75 16.61 17.48 I8 .21 9Z 09 318 so 1 1. .98 .84 124 I5.2818.JX14 7.12 75 1000 134 11 65 30 1131 143 17: .23 .78 28 1 33 .I2 1 a> 87 i818'11�11 *7bmv P$*b"#M .- oa a �IYtf Y b 11mip Roars Wftvd Platte m6rb h lea alm br man lr mrm I1 M Ri A bfas mled.e near z o b a +e m0. i U"w bond of the N% cad lnttrvd tlon F.dlmates A1ZI*"' 3 mb 10 mha 13 mfn 30 mm 60 120 mie 3 tr f tr 12 !,r 24 tr Y trday 4 '. 7 10 20 30 4t 60 1 0 5 90 1.12 1S3 1.91 46 .04 S$ Z7 .02 6$ .46 27 .6S 11.7 14. I7 5 2 0. 1. 133 1. 1 79 .69 33 5.19 .08 .83 .79 .71' 11.51 13.96 17 26 .61 S 78 1 1 56 81 .73 .59 .71 .80 .68 .79 10.80 14.02 16 74 .45 I 1.7 31 21 .S4 .64 .69 8.03 .29 10 11. 12M I6.01 ] 8. .03 .85 25 0.98 1 1 .8 .14 .61 37 10. 1I338 12 13 91 IS. 19. I .61 0.61 50 1.0611.69 1 73 3 95 58 $.20 .87- 11. 13.61 14 64 15.99 17 1.55 73 A 3 58 100 1:151.83 1 .53 84 64 55 1138I3.98 IS.91 16.93 18.2819.54 .21 39 24 6.59 200 1 1. .85 80 .81 11. 13.52 16.3618.5619.49 09 .11 .19 5.58 9.58 SW 1.33 14 28 .l 28 10. 13.46 16 I8 64 .4 .61 94 1 .19 9.86 3.6 1000 1. 8 75 I0.571I5 58 19 25 .90 .83 .18 .76 7,38 38 .91 -TIN-, hound h caldldlaoa a! A n cf h aba 4-0 berrnr N 0- emt• 'Th as p+ 411 1 cname Yi1l Plum mw b liar br aan kdxmair JIM Fanmfq prwurt eaiadaa n�aaos b appaa Laver bo=d of tU,90% Wnfidente httervd ]Isdmatw A U** ern S i 10 mmzwkmb •15 30 50 120 3 tr f ter U br 24 a tr hr 4 7 ' 3.49 1A Sfi 30 day 45 1 day 60 1 .4 .78 1341. 1 08 59 3.00 .SQ 4.16 .22 37 103713. 15.63 18.4 1.53 2 .38 .93 1.1 1.61 .14 3.64 .24 5.03 .70 6 62 .43 98 12 3 4.78 15.38 18.21 3 .68 I.08 13 1 23 .M .70 A8 A4 .19 8 30 .19 1214 10 751 1 1 S6 3 83 .i3 .78 .91 .62 36 .64 AS 69 10.651391 16.73 4 .95 25 85 133 I.71 53 3 .98 8.15 .43 ' 1018 11. 1274 1638 19A3 .57 7.20 SO 1. 1.85 78 51 .90 lw.21 .56 10 11.83133 14.45I83S 1. .94 .67 1 200 1.06 1.6 10 .5 .4 .17 l 1.06 I2.90 I4.48 I5.32 16.89 i8 11 SS 23 78 0.73 .41 LpIV7E� JAN 1 9 2012 BY: Appendices Table 8.03g Runoff curve numbers for other agriculture lands' Curve numbers for soil groups -- Hydrologic Cover type conditions' A B C Q Pasture, grassland, or range— Poor 68 79 86 89 continuous forage for grazing. Fair 49 69 79 84 Good 39 61 74 80 Meadow —continuous grass, protected — 30 58 71 78 from grazing and generally mowed for hay. Brush —brush -weed -grass mixture with Poor 48 67 77 83 brush the major element.' Fair 35 56 70 77 Good 304 48 65 73 Woods --grass combination (orchard or Poor 57 73 82 86 tree farm). s Fair 43 65 76 82 Good 32 58 72 79 Woods.6 Poor 45 66 77 83 Fair 36 60 73 79 Good 304 55 70 77 Farmsteads --buildings, lanes, — 59 74 82 86 driveways, and surrounding lots. 1 Average runoff condition, and l.= 0.25. 2 Poor: <50% ground cover or heavily grazed with no mulch. Fair. 50 to 75% ground cover and not heavily grazed. Good: > 75% ground cover and lightly or only occasionally grazed. 3 Poor: <50% ground cover. Fair.' 50 to 75% ground cover. Good: >75% ground cover. 4 Actual curve number is less than 30; use CN = 30 for runoff computations. 5 CN's shown were computed for areas with 50% woods and 50% grass (pasture) cover. Other combinations of conditions may be computed from the CN's for woods and pasture. 6 Poor. • Forest litter, small trees, and brush are destroyed by heavy grazing or regular burning. Fair. Woods are grazed but not bumed, and some forest litter covers the soil. Good: Woods are protected from grazing, and litter and brush adequately cover the soil. R�CRTVED JAN 19 2012 BY: Rev. 6106 8.03.17 Appendices 1 Table 8.03e Runoff curve numbers of urban areas' I Curve number for -------------- . ---- ---Cover Description--------_--_---_ _—__hydrologic soil group---"—. Cover type and hydrologic condition Average percent A i3 C D impervious areal Fully developed urban areas (vegetation established) Open space (lawns, parks, golf courses, cemeteries, etc.) 3: Poor condition (grass cover < 50%) ............. :............... 68 79 86 89 Fair condition (grass cover 50% to 75%) ..................... 49 69 79 84 Good condition (grass cover > 75%) ............................ 39 61 74 80 Impervious areas: Paved parking lots, roofs, driveways, etc. 98 98 98 98 (excluding right-of-way) ............................................... Streets and roads: Paved; curbs and storm sewers (excluding 98 98 98 98 right-of-way).................................................................. Paved; open ditches (including right-of-way) ................ 83 89 92 93 Gravel (including tight -of -way) ...................................... 76 85 89 91 Dirt (including right-of-way) ........................................... 72 82 87 89 Urban districts: Commercial and business ................................................. 85 89 92 94 95 industrial........................................................................... 72 81 88 91 93 Residential districts by average lot size: 118 acre or less (town houses) ......................................... 65 77 85 90 92 114 acre....................................................... ......... ..... ....... 38 61 75 83 87 113 acre............................................................................. 30 57 72 81 86 112 acre............................................................................ 25 54 70 80 85 1 acre............................................................................... 20 51 68 79 84 2 acres.............................................................................. 12 46 65 77 82 Developing urban areas Newly graded areas 77 86 91 94 (pervious areas only, no vegetation)' .............................. Idle lands (CN's are determined using cover types similar to those in table 2-2c). 1. Average runoff condition, and la = 0.2S. 1 2. The average percent impervious area shown was used to develop the composite CN's. Other assumptions are as follows: Impervious areas are directly connected to the drainage system, impervious areas have a CN of 98, and pervious areas are considered equivalent to open space In good hydrologic condition. CN's for other combinations of conditions may be computed using Figure 8.03c or 8.03d. 3. CN's shown are equivalent to those of pasture. Composite CN's may be computed for other combinations of open space cover type. 4. Composite CN's to use for the design of temporary measures during grading and construction should be computed using Figure 8.03c or 8.03d based on the degree of development (impervious area percentage) and the,CN's for the.newly'graded'pervious areas. Rev.6106 JAN 9 2012 8.03-15 By RPE2=09-1996 16:15 FROM FHNR WIL.M PEG OFFICE TO, 97624201 P.02 m 85% TSS REMOVAL 30 FOOT 'VEGETATED FILTER REQUO ED Dl� 3' 3.5' 4.0' 4.5' 5.0' 5.5' 6.0' 6.5' 7.0' 7.5' Wee% 10% .9 .8 .7 .6 .5 0 lo 0 0 lo 20 % 1.7 1.3 1.2 1.1 1.0 .9 .8 .7 .671.5 30 % 2.5 2.2 1.9 1.8 1.6 1.5 1.3 1.2 1.0 1.9 40 % 3.4 3.0 2.6 2.4 2.1 1.9 1.6 1.4 1.1 1.0 50 % 4.2 3.7 3.3 3.4 2.7 2.4 2.1 1.8 1.5 1.3 60 % 5.0 4.5 3.8 3.5 3.2 2.9 2.6 2.3 2.0 1.6 70 % 6.0 5.2 4.5 4.1 3.7 3.1 2.9 2.5 2.1 1.$ 80 % 6.8 6.0 5.2 4.7 1 4.2 3.7 3.2 2.7 2.2 2.0 90 % 7.5 6.5 5.8 S.3 14.8 4.3 3.8 3.3 2.8 1.3 100 % 18.2 17.2, 6.8 6.2 5.6 S.Q 4.4 3.8 3.2 2.6 90% TSS REMOVAL NO VEGETATED FILTER REQUWW DMU 3' 3.5' 4.0' 4.5' 5,0' 5.5' 6.0' 6.5' 7.0' 7.5' imp % 10 % 1.3 1.0 .8 .7 .6 .5 .4 ,3 .2 .1 20 % 2.4 2.0 1.8 1.7 1.5 1.4 1.2 1.0 .9 .6 30 % 3.5 3.0 2.7 2.5 2.2 1.9 1.6 1.3 1.1 .8 40 % 4.5 4.0 3.5 3.1 2.8 2.5 2.1 1.8 1.4 1.1 50 % 5.6 5.0 4.3 3.9 3.5 3.1 2.7 2.3 1.9 1.5 60 % 7.0 6.0 5.3 4.8 4.3 3.9 3.4 2.9 2.4 '1.9 70 % 8.1 7.0 6.0 5.5 15.0 4.5 13.9 3.4 2.9 2.3. 80 % 9.4 8.0 7.0 6.4 5,7 5.2 4.6 4.0 3.4 2.8 90 % 10.7 19.0 7.9 7.2 6.5 5.9 5.2 14.6 3.9 3.3 100 % 12.4 1 10.0 8.8 18.1 7.3 6.6 5.8 5.1 4.3 3'.6 . . ..�.:,1l;�,�...s;l,•;; : _. _._ INLET, N.C. NEW RIVERC xs N3430—W7715/7.5 -- �� 1952 �1 Flik (E) PFIOTOREVISED 1971 AMIS 5553 111 86—SERIB8 V849 SCALE 1:24000 l 0 1 MIL 1000 0 1000 ` 2006. M 4000 ww 6000• 7000 FEET 0 1 KILOMETER ,CbNTOUR INTERVAL 5 FEET AfViW IS MEAN SEA LEVEL DEPTH CURVES ANO'SOUNDINGS IN FEED —DATUM IS MEAN LOW WATER SHORELINE SHOWN RE'PREY[NTB THE APPROXIMATE LINE OF MEAN RICH WATER TMt "&,m DArec no T1.11 IC a cccT REPORT OF SUBSURFACE EXPLORATION AND GEOTECHNICAL ENGINEERING ANALYSIS P1251 & P1254 COURTHOUSE BAY BEGS MC13 CAMP LEJEUNE, ONSLOW COUNTY, NORTH CAROLINA PREPARED FOR: .MR. ANDREW ANELLO HARPER CONSTRUCTION COMPANY, INC. E 2241 KTNER BOULEVARD SUITE 300. SAN DIEGO, CALIFORNIA 9210/4769 PREPARED BY: ECS CAROLINAS, LLP • 7211 OGDEN BUSINESS PARK SUITE 201 W IL.MINGTON, ,NORTH CAROLINA 28411 ECS CAROLINAS, LLP PROJECT NO.: 22.17167 FIRM NO. F-1087 ;ate PEkA . 033 81 r Gr����` Nc'C033751 NOVEMBER 7, .2011 . �CEIVED JAN 1 9 2012 BY: Report of Subsurface Exploration and Geotechnical Engineering Analysts P1251 & P1254 Courthouse Bay BEQs MCS Camp Lejeune, Cnskm County, North Carolina ECS Project No.: 22.17167 4.3 Seasonal High Water Table and InfinMon Test Results The results from groundwater observations, seasonal high water level (SHWL) estimates and Infiltration tests performed in the hand auger borings are summarized below: Location SHWL in Ground Water In Infiltration Test Depth In Infiltration Rate Whr 11 18 36 10 0.56 1-1-A 24 60 24 0.01 I-1-B 18 30 10 4.1 1-2 24 48 10. _ 8.9 1-3 18 36 10 3.6 1-4, 36 36 12 3.2 1-5 48 76 24 13.0 1-6 50 70 28 17.2 1-7 60 90 36 15.6 I-8` BO 90 36 12.9 1-9 48 80 24 8.3 1-10 48 1 76 +-24 4.1 For detailed Information, see the infiltration testing form in Appendix C. 4.8 Laboratory Test Results Index and engineering properties tests were performed on select samples of the sample soils encountered within the test borings. In summary, the tested samples had in -situ moisture contents of 6.3 to 47.4. The Atterberg limits analysis of the tested sample Indicated Liquid limits of 42 and 44, plastic limit of 19 and plasticity Indices of 23 and 25. The grain size analyses of the tested samples indicated that the tested materials had 4.6 to 25.8 percent fines passing the number 200 sieve. Specific laboratory test results are provided in the Laboratory Testing Summary In Appendix E of this report. RJECEIVED JAN 1 9 2012 BY: E C S C A RO LI N A S, L L P "Setting the Standard for Service" Geotechnical - Construction Materials - Environmental - Facilities NCRepWeredEnpLieerinpFTrmF-1078 December 19, 2011 Mr. Andrew Anello Harper Construction Company, Inc. 2241 Kettner Boulevard Suite 300 San Diego, California 92101-1769 Reference: Report of Additional Infiltration Testing P1251 & P1254 Courthouse Bay BEQs MCB Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167-A Dear Mr. Anello: ECS Carolinas, LLP (ECS) recently. conducted additional infiltration testing for the proposed stormwater best management practice (BMP) areas at the P-1251 & P-1254 Site in MCB Camp Lejeune, Onslow County, North Carolina. This letter, with attachments, is the report of our testing. Meld Testing On December 14, 2011, ECS conducted an exploration of the subsurface soil and groundwater conditions at two requested locations (1-11 and 1-12) shown on the attache_ d Boring Location Plan (Figure 1). The purpose of this exploration was to obtain subsurface information of the in -place soils for the proposed stormwater BMP area. ECS explored the subsurface soil and groundwater conditions by advancing one hand auger boring into the existing ground surface at the requested boring locations. ECS visually classified the subsurface soils and obtained representative samples of each soil type encountered. ECS also recorded the groundwater level and the seasonal high water table (SHWT) observed at the time of the hand auger borings. The attached Infiltration Testing Form provides a summary of the subsurface conditions encountered at the hand auger boring locations. The groundwater level and the SHWT were estimated at the boring locations below the existing grade elevation. A summary of the findings are as follows: 1-11 > 60 inches 48 inches 1 1-12 > 60 inches 40 inches ECS has conducted two infiltration tests utilizing a compact constant head permeameter near the hand auger .borings to estimate the infiltration rate for the subsurface soils. Infiltration tests are typically conducted at two feet above the SHWT. ff the SHWT is less than three feet, the tests are conducted at ten inches below the surface elevation. 7JAN CEI�.ED 1 9 2012 tl: 7211 Ogden Business Park, Suite 201, Wilmington, NC 28411 - T: 910-686-9114 - F: 910-686-9666 - www.ecslimited.com I f' Report of IrdllhOCAn resting P1261 & P1254 Caurffmse Bay BE09 MC8 Camp Lejeune, Qnslow County, North Carolina ECS Profed Na 22-17167A December 19, 2011 Field Test Results Below Is a summary of the infiltration test results: ��.Y%.Ta-r .,. ��� Jt Y 7jT �A7N `"i�r N. "f" ?�ffd�h l; �i-0 1ii.t"7r�?}DO �' e }t o s ` �'�`� 'x d� ' tAY.l r:s�'i'�'.�1'r �R' ?,S.Si Jc i'W1k.'�,' 1 ,`y ` u.: "^ �v.._ ,L�6. IL.�. itc�':,?" a',ii;'•�,34 -11 Gra 'fine SAND 24 Inches 9.3 : k1Z Tan fine SAND 16 Indies 5.0 Infiltration rates and SHWT may vary within the proposed site due to changes In elevation and subsurface conditions: Closure The acMJes and evaluative approaches used In this assessment are Consistent with those normally employed In assessments of this type. ECS's testing of site conditions has been based on our undemtanding.of the project Information and the data obtained during our field aches. ECS appr+edatss the opportunity. to provlde our services to you on this project. if you have any questlons conceming this report or this project, please oontaci us at (910) 68e- 9114. Respectfully,. ECS CAROLINAS, LLP K. Brooks Wall Project Manager Attachments: Figure 1 - Boring location Plan Infiltration Testing Form c Walld M. Sobh, P.E. Principal Engineer RECEIVED ,BAN 1 9 2012 BY: 2 I I E)CIPLORATIONALJ P-I254 GOUKTH" BEG U MCATInm IMIAOR a Infiltration Testing Form Courthouse Bay Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167 October 27, 2011 Location Depth Soil Description 1 0_10" Gray silty SAND 10"-24" Tan fine SAND 24%36 Tan/orange clayey SAND Seasonal High Water Table was estimated to be; at 18 inches below the existing grade elevation. Infiltration Rate: 0.56. inches per hour - Test was conducted at 10 inches below existing grade elevation Groundwater was encountered at 36 inches below the existing grade elevation. Location Depth Soil Description. 2 0-10" Gray. fine SAND 10"-30" Tan fine SAND 30"-48 Tan/orange clayey SAND Seasonal High Water Table was estimated to be at 24inches below the existing grade elevation: Infiltration Rate: 8.9 inches per hour Test was conducted at 10. inches below existing grade elevation Groundwater was encountered at 48 inches below the existing grade elevation. Location Depth Soil Description 3 0-6° Gray silty SAND 6"-18 Gray fine SAND 18"-38" Tan fine SAND w -Hardpan Seasonal High Water Table was estimated to be at 18 inches below the existing grade elevation. .infiltration Rate: 3.6 inches per hour Test was conducted at 10 inches below existing grade elevation Groundwater was encountered at 36 inches below the existing grade elevation. FZECEIVED JAN 1 9 2012 BY: Infiltration Testing Form Courthouse Bay Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167 October 27, 2011 Location. Depth Soil Description 4 0-10" Gray silty SAND 10"-40" Tan fine SAND 40n-60° Tan/orange clayey SAND Seasonal High Water Table was estimated to be at 36 inches below the existing grade elevation., Infiltration Rate: 3.2 inches per hour Test was; conducted at 12 inches below existing grade elevation Groundwater,was encountered at '36 inches below the existing grade elevation. Location Depth Soil Description 5 0-24" Gray fine SAND 24"-30" Hardpan .30"-80" Tan- fine SAND Seasonal High Water Table .was estimated to be. at 48 inches below the existing grade elevation. Infiltration Rate: 13.0 inches per hour Test was conducted at 24 inches below existing grade elevation Groundwater was encountered at 76 inches below the existing grade elevation. Location Death Soil Description 6 0-2419Gray fine SAND 24"-70` . Tan tine SAND Seasonal High Water Table was estimated to be at 50 inches below the existing grade elevation. Infiltration Rate: 17.2 inches per hour Test was. conducted at 26 inches below existing grade elevation Groundwater_ was encountered at 76 inches below the existing grade elevation. CEEVEF3 JAN 1 9 2012 BY: I 1' Infiltration Testing Form Courthouse Bay Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167 October 27, 2011 Location Depth Soil Description 7 0-10" Gray fine SAND 10"-38" Tan fine SAND 38"-48" Tanlorange. fine SAND w clay 48" -90" Tan f ne SAND. Seasonal High Water Tablewas estimated to be at 60 inches below_ the existing grade elevation. Infiltration ,Rate: 15.6 inches per hour Testwas conducted at 36 inches below existing grade elevation Groundwater was encountered at 90 inches .below the existing grade elevation. Location Depth 81 0-18" 'IT-48" 48"--60" 60"-90" Soil Description Gray -fine SAND . Tan fine SAND Tan/orange fine SAND w clay Tan fine. SAND Seasonal High. Water Table was estimated to be at 60 inches below the existing grade elevation - Infiltration Rate: 12.9 inches per hour Test: was conducted at 36' inches below existing grade elevation Groundwater was encountered. at 90 inches below the existing grade elevation. Location Depth Soil Description 9 0-80" Tan/brown fine SAND Seasonal High. Water Table was, estimated to be at 48 inches below the existing grade elevation: Infiltration Rate: 8:3 inches per hour Test Was conducted at 24 inches below existing grade elevation Groundwater was encountered at 80 inches below the existing grade elevation. RE CEIVED JAN 1 9 2012 BY: � ♦ Y Infiltration Testing Form Courthouse Bay Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167 Octo bet 27. 2011 Location Depth Soil Description. 10 0-16" Gray fine SAND 16"-24" Hardpan 24"-80" Tan fine SAND Seasonal High Water Table was estimated to be at 48 inches below the existing grade elevation. lnfiltratlon Rate: 4.1 inches per hour Test was conducted at 24 inches below existing grade elevation Groundwater was encountered at 76 inches below the existing grade elevation. RECEIVED JAN 1 9 2012 BY: 1k .. Infiltration Testing Form P-1251 & P-1254 Courthouse Bay Geotech Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167A December 14, 2011 Location Death Soil DescriR n 1-11 0-30" Gray fine SAND 30"-50" Tan fine SAND 50"-60" Tan/orange clayey SAND Seasonal High Water Table was estimated to be at 48 inches below the existing grade elevation.. Infiltration Rate: 9.3 inches per hour Test was conducted at 24 Inches below existing grade elevation Groundwater was not encountered up to 60 inches below the existing grade elevation. Location Depth Soil Description 1-12 0-12" Gray fine SAND 12-36" Tan fine SAND 36"-60" Tan/orange fine SAND w clay lens Seasonal High Water Table was estimated to be at 40 inches below the existing grade elevation. Infiltration Rate: 5.0 inches per hour Test was conducted at 16 inches below existing grade elevation Groundwater was not encountered up to 60 inches below the existing grade elevation. RECEIVED By: Infiltration Testing Form P-1251 & P-1254 Courthouse Bay Geotech Camp Lejeune, Onslow County, North Carolina ECS Project No. 22.17167 November 3, 2011 Location Depth Soil Description 1-1 -A 0-12" Gray fine SAND 12"-24" Brown fine SAND 24"-60" Tan clayey SAND Seasonal High Water Table was estimated to be at 24 inches below the existing grade elevation. Infiltration Rate: 0.01 inches per hour Test was conducted at 24 inches below existing grade elevation Groundwater was encountered at 60 inches below the existing grade elevation. Location Depth Soil Description 1-1-13 0-6" Gray silty SAND 6"-18" Gray fine SAND 18"-24" Hardpan 24"48" Gray fine SAND Seasonal High Water Table was estimated to be at 18 inches below the existing grade elevation. Infiltration Rater 4.1 inches per hour Test was conducted at 10 Inches below existing grade elevation' Groundwater was encountered at 30 inches below the existing grade elevation. DECEIVED JAN 1 9 2012 BX: \A,e Vp )&"""ID) A I- \-RD \VaM vc A �� ,ZhTl L- 41' Nelson, Christine From: Nelson, Christine Sent: Wednesday, January 11, 2012 8:49 AM To: Wright, Rodney; 'howard@coastalsitedesign.com'; 'Thomas Bradshaw (Thomas. bradshaw@usmc. mil)' Cc: Russell, Janet Subject: Courthouse Bay BEQ vs Bayshore Commercial Howard & Rodney, I have had a chance to look over the Bayshore Commercial project (SW8 090704) and have gotten some insight from Kelly, who permitted the project. This project was permitted in 2009 during a time we were still trying to figure out how to handle the discharge from ponds within %: mi or SA waters. Even now, without written and approved guidance, we are still trying to nail down the specifics but at least we have a better idea of what is necessary. From the correspondence in the Bayshore file, it appears that there was no DWQ requirement to store/detain the 10 year storm event (maybe the basin was to meet NHC quantity requirements?). It looks like this project was required to provide a level spreader and filter strip designed to handle the pond discharge from the 10-year storm and provide effective infiltration of the design storm. (This may have been where my fuzzy state yesterday didn't help.) the rules don't require the entire 10 year storm event to be infiltrated, just the design storm. The rules just require the flow in excess of the design storm go through a filter strip. As long as you can provide calculations for the 10 yr storm discharge rate, provide a level spreader and filter strip sized for that flow, and demonstrate that the design storm can effectively infiltrate within the filter strip, then there is no need to permit that area as a basin. Let me know if you have any questions. Christine Christine Nelson Environmental Engineer NC DWQ - Stormwater Program Wilmington Regional Office 910-796-7323 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. 0 NVF a- M N Z P R W Z ZZ �O� gw �„ IL Jill ul Mu Q U 04 <L For OENR Use ONLY 5 CQ [� I�y Reviewer. _G 0 �� Is" North Carolina Department of Environment and i Natural Resources submit: NC®ENR Request for Express Permit Review Time: .. Confirm: ( Z� FILL-IN all the information below and CHECK the Permit(s) you are requesting for express review. FAX or Email the completed form to Express Coordinator along with a completed DETAILED narrative, site plan (POF file) and vicinity map (same items expected in the application package of the project location. Please include this form in the application package. • Asheville Region -Alison Davidson 828-296-4698;aiison.davidson(-ncmail.nef • Fayetteville or Raleigh Region -David tee 919-791-4203; david.lee(c -ncmail.net • Mooresville & -Patrick Grogan 704-663-3772 or patrick.-grogan(o-ncmailmet • Washington Region -Lyn Hardison 252-946-9215 or lyn.hardison0mcmail.net • Wilmington Region -Janet Russell 910-350-2004 or ianet.russell(a)ncmail.net NOTE: Project application received after 12 noon will be stamped in the following work day. Enter Related SW Permits of request SW SW SW SW SW n exf Project Name: P1254 COURTHOUSE BAY County: ONSLOW Applicant: CARL BAKER - Company: MARINE CORPS BASE, CAMP LEJEUNE Address: BLDG 1005 MICHAEL ROAD City: MCB CAMP LEJEUNE, State: NC Zip: 28547-_ Phone: 910-451-2213, Fax: 910-451-2927, Email: earl.h.baker@usmc.mil Physical Location:CORNER OF MUNRO ROAD AND COMMAND DRIVE Project Drains into SA:HQW waters — Water classification 19-36 (for classification see-http:Ilh2o,enr.state.nc.us/bims/reports/reportsWB.htm1) Project Located in WHITE OAK River Basin. Is project draining to class ORW waters? N , within '/z mile and draining to class SA waters Y or within 1 mile and draining to class HQW waters? Y Engineer/Consultant: HOWARD RESNIK Company: COASTAL SITE DESIGN, PC Address: PO BOX 4041 City: WILMINGTON, State: NC Zip: 28406-_ 1REC EIVED Phone: 910-791-4441, Fax: 910-791-1501, Email: HOWARD@COASTALSITEDESIGN.COM SECTION ONE: REQUESTING A SCOPING MEETING ONLY NOV 2 S 2011 ® Scoping Meeting ONLY ® DWQ, ❑ DCM, ® DLR; ❑ OTHER: %BY: SECTION TWO: CHECK ONLY THE PROGRAM (S) YOU ARE REQUESTING FOR EXPRESS PERMITTING ❑ 401 Unit ❑ Stream Origin Determination: _ # of stream calls - Please attach TOPO map marking the areas in questions ❑ In term ittent/Perennial Determination; T # of stream calls - Please attach TOPO map marking the areas in questions ❑ 401 Water Quality Certification ❑ Isolated Wetland {_linear ft or _acres) ❑ Riparian Buffer Authorization ❑ Minor Variance ❑ Major General Variance ❑ State Stormwater ❑ General ❑ SFR, ❑ SFR < 1 ac. ❑Bkhd & Bt Rmp, ❑ Clear & Grub, ❑ Utility ❑ Other ❑ Low Density ❑ Low Density -Curb & Gutter _ # Curb Outlet Swales ❑ Off -site [SW (Provide permit #)] ElHigh Density -Detention Pond # Treatment Systems ❑ High Density -Infiltration - #Treatment Systems ❑ High Density -Bio-Retention _ # Treatment Systems ❑ High Density -SW Wetlands _ # Treatment Systems ElHigh Density -Other _ # Treatment Systems / ❑ MOD:❑ Major ❑ Minor ❑ Plan Revision ❑ Redev. Exclusion SW (Provide permit#) ❑ Coastal Management ❑ Excavation & ❑ Upland Devel. ❑ Land Quality ❑ Erosion and Sedimenta �� 12 - l ❑ Structures Information ❑ Urban Waterfront ,rbed.(CK # (for DENR use)) SECTION THREE - PLEASE CHECK ALL THAT IS ; ( oo i for both scoaing and express meeting request Wetlands on Site ❑ Yes ® No r D No ❑ YES: _acre(s) Wetlands Delineation has been completed: El Yes ❑ i I Z-fa cannrr►�tcj Ion Property ❑ Yes ❑ No US ACOE Approval of Delineation completed: ❑ Yes r n o-t p rN, l(a y t-7, 2c> in Process wl US ACOE: ❑ Yes [I No Permit Received from US ACOE ❑ Yes ❑ No i DE;NR use 011Ey******+w+****+++++++++++++++++*+++++++s+*t**** *a+r+****s**+ Fee Split for multiplepermits: Check # Total Fee Amount $ SUBMITTAL DATES Fee SUBMITTAL DATES Fee CAMA $ Variance (❑ Maj; ❑ Min) $ SW (❑ HD, ❑ LD, ❑ Gen) I $ 401: 1 $ LOS $ Stream Deter,_ $ NCDENR EXPRESS March 2009 NCDENR North Carolina Department of Environment and Natural Resources Beverly Eaves Perdue Governor November 28, 2011 r. Paul Roberts, Vice President erican Tower Corporation, Manager A rican Towers LLC 400 egency Forest Dr. Cary, C 27518-7723 Subject: Request for Additional Information ormwater Project No. SW8 110419 Hi s Road American Tower Site 273437 Ca et County Division of Water Quality Coleen H. Sullins Director Dear Mr. Roberts: Dee Freeman Secretary The Wilmington Region Office received an Express Stormwater Management Permit Application for the Hibbs ad American Tower Sitee/273437 on November 17, 2011. A preliminary review of that in rmation has determined that the application is not complete. The following information is neede to continue the sto`rmwater review: 1. In the e-mail from Caro ' e Blount �gineer, dated 11/32011, an amended annual report for American Tow Corporation dated July 20 2011 was provided in order to demonstrate that Mr. Robe s is%a Vice President of this organization. However, it was not disclosed at that tim that on July 26, 2011 American Tower Corporation was withdrawn from the NC e etary of Stake by a merger with American Towers LLC. If the manager of A rican owers LLC is still American Tower Corporation as indicated in the July 12, 11 LLC plication, please provide current documentation that American Tower C poration is a egistered corporation with active status in one of the 50 states and pr vide official doc entation that Mr. Roberts is currently a Vice President with t is organization. 2. In Section IV.10 q(the application: a. Please rify that the total impervious s\waived d in the second table is Corr t. b. Plea ensure that the proposed imper% impervious area list in the first table considers the futurea allocated in the 'eond table. 3. The a ress additional information fee has bees request for additional 4. PI ase keep in mind that changing one number may change other mbers and r quire the calculations, supplements, and other supporting docume tion to be pdated. Verify all numbers are correct to ensure consistency in the a lication documents. Pleas note that this request for additional information is in response to a preliminary review. The equested information should be received in this Office prior to December 5, 2011, or the ap ication will be returned as incomplete. The return of a project will necessitate resubmittal of required items, including the application fee. Wilmington Regional Office 127 Cardinal Drive Extension, Wilmington, North Carolina 28405 One Phone: 910-796-72151 FAX: 910.350-20041 Customer Service: 1-877-623.6748 North Carolina tntemet: http://portaJ.nodenr.org Aatu m/ # An Equal Opportunity 1 Affirmative Action Employer " � � z COASTAL SITE DESIGN, PC PO Box 4041 Wilmington, NC 28406 Phone: 910 791-4441 Fax: 910 791-1501 License # C-2710 .FOR STORMWATER EXPRESS REVIEW November 2011 PROJECT NAME: Bachelor Enlisted Quarters, MCAS P-1254 MCB Camp Lejeune, NC Onslow County PROJECT DESCRIPTION: The project area for this development is 12.09 acres with 11.00 acres of disturbance. There are no wetlands within the project limits. This project is for the construction of barracks, basketball courts and a parking deck to be located at Courthouse Bay. The owner is the United States Marine Corps. Water and sewer will be provided by the Base. Stormwater from the site will drain to SA;HQW waters located in the White Oak River Basin (Index # 19-36). The project will be high density utilizing a wet basin that discharges into a filter strip so it meets the requirement of no new stormwater discharge. Storntwater will be conveyed to the pond using an underground stormwater collection system and open ditches. Proposed impervious for the site is 48.6%. The site will have direct access to Munro Road. SH WT tess have been performed at the proposed location of the wet basin and the PP of the basin will be set at 0.5 ft above or below the S14 WT elevation. PROJECTBMP: high density wet pond. STORMWATER ENGINEER/CONSULTANT: Coastal Site Design, PC PO Box 4041 Wilmington, NC 28406 Rodney Wright rodney@coastalsitedes ign.co m 910 7914441 office 910 791 1501 fax