HomeMy WebLinkAboutSW8030322_HISTORICAL FILE_20030707STORMWATER DIVISION CODING SHEET POST -CONSTRUCTION PERMITS PERMIT NO. SW��� DOC TYPE ❑ CURRENT PERMIT ❑ APPROVED PLANS HISTORICAL FILE ❑ COMPLIANCE EVALUATION INSPECTION DOC DATE- YYYYMMDD r State Stormwater Management Systems Permit No. SW8 030322 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY STATE STORMWATER MANAGEMENT PERMIT HIGH DENSITY DEVELOPMENT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Golden Sands Motel, LLC Golden Sands I Sandfiddler Motel New Hanover County FOR THE construction, operation and maintenance of infiltration trenches in compliance with the provisions of 15A NCAC 2H .1000 (hereafter referred to as the "stormwater rules') and the approved stormwater management plans and specifications and other supporting data as attached and on file with and approved by the Division of Water Quality and considered a part of this permit. This permit shall be effective from the date of issuance until July 7, 2013, and shall be subject to the following specified conditions and limitations: I. DESIGN STANDARDS 1. This permit is effective only with respect to the nature and volume of stormwater described in the application and other supporting data. 2. This stormwater system has been approved for the management of stormwater runoff as described on page 3 of this permit, the Project Data Sheet. The stormwater control has been designed to handle the runoff from 61,275 square feet of impervious area. This pond must be operated with a vegetated filter. 3. The tract will be limited to the amount of built -upon area indicated on page 3 of this permit, and per approved plans. 4. All stormwater collection and treatment systems must be located in either dedicated common areas or recorded easements. The final plats for the project will be recorded showing all such required easements, in accordance with the approved plans. 5. The runoff from all built -upon area within the permitted drainage area of this project must be directed into the permitted stormwater control system. A permit modification must be submitted and approved prior to the construction of additional built -upon area from outside of the approved drainage area. 2 State Stormwater Management Systems Permit No. SW8 030322 DIVISION OF WATER QUALITY PROJECT DESIGN DATA SHEET Project Name: Golden Sands 1 Sandf ddler Motel Permit Number: SW8 030322 Location: New Hanover County Applicant: Mr. Jimmy Pope Mailing Address: Golden Sands Motel, LLC 1211 S. Lake Park Blvd. Carolina Beach, NC 28428 Application Date: July 7, 2003 Receiving Stream/River Basin: Cape Fear River / Cape Fear Stream Index Number: CPF17 18-(87.5) Classification of Water Body: "SA HQW" Design Storm: 2" (no vegetated filter is required) Trench No.: WEST EAST Drainage Area, acres: 1.37 0.69 Trench Dimensions, LxWxH, feet: 629 x 22.5 x 1.25 138 x 51 x 1.25 Total Impervious Surfaces, ftz.: 41,206 20,069 Bottom Elevation, FMSL: 9.3 9.3 Perforated Pipe Diameter/ Length: 12" 1629' 12" 1 138' Required Storage Volume, ft3: 7,494 3,676 Provided Storage Volume, ft3: 7,513 3,683 Temporary Storage Elevation, FMSL: 11.3 11.3 Type of Soil: Sand Sand Expected Infiltration Rate: 65 in/hr 65 in/hr Seasonal High Water Table: 7.3 7.3 Time to Drawdown: 1.9 hours 0.25 hours 3 State Stormwater Management Systems Permit No. SW8 030322 H. SCHEDULE OF COMPLIANCE 1. The stormwater management system shall be constructed in its entirety, vegetated and operational for its intended use prior to the construction of any built -upon surface. 2. During construction, erosion shall be kept to a minimum and any eroded areas of the system will be repaired immediately. 3. The permittee shall at all times provide the operation and maintenance necessary to assure the permitted stormwater system functions at optimum efficiency. The -approved Operation and Maintenance Plan must be followed in its entirety and maintenance must occur at the scheduled intervals including, but not limited to: a. Semiannual scheduled inspections (every 6 months). b. Sediment removal. C. Mowing and revegetation of slopes and the vegetated filter. d. Immediate repair of eroded areas. e. Maintenance of all slopes in accordance with approved plans and specifications. f. Debris removal and unclogging of outlet structure, orifice device, flow spreader, catch basins and piping. g. Access to the outlet structure must be available at all times. 4. Records of maintenance activities must be kept and made available upon request to authorized personnel ofDWQ.' The records will indicate the date, activity, name of person performing the work and what actions were taken. 5. Decorative spray fountains will not be allowed in the stormwater treatment system. 6. The facilities shall be constructed as shown on the approved plans. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 7. Upon completion of construction, prior to issuance of a Certificate of Occupancy, and prior to operation of this permitted facility, a certification must be received from an appropriate designer for the system installed certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting documentation. Any deviations from the approved plans and specifications must be noted on the Certification. A modification maybe required for those deviations. 8. if the stormwater system was used as an Erosion Control device, it must be restored to design condition prior to operation as a stormwater treatment device, and prior to occupancy of the facility. 9. The permittee shall submit to the Director and shall have received approval for revised plans, specifications, and calculations prior to construction, for any modification to the approved plans, including, but not limited to, those listed below: a. Any revision to any item shown on the approved plans, including the stormwater management measures, built -upon area, details, etc. b. Project name change. C. Transfer of ownership. d. Redesign or addition to the approved amount of built -upon area or to the drainage area. e. Further subdivision, acquisition, or sale of all or part of the project area. The project area is defined as all property owned by the permittee, for which Sedimentation and Erosion Control Plan approval or a CAMA Major permit was sought. f. Filling in, altering, or piping of any vegetative conveyance shown on the approved plan. 4 State Stormwater Management Systems Permit No. SW8 030322 10. The permittee shall submit final site layout and grading plans for any permitted future areas shown on the approved plans, prior to construction. If the proposed BUA exceeds the amount permitted under this permit, a modification to the permit must be submitted and approved prior to construction. 11. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of ten years from the date of the completion of construction. 12. At least 30 days prior to the sale or lease of any portion of the property, the permittee shall notify DWQ and provide the name, mailing address and phone number of the purchaser or leasee. An access/maintenance easement to the stormwater facilities shall be granted in favor of the permittee if access to the stormwater facilities will be restricted by the sale or lease of any portion of the property. 13. The permittee must maintain compliance with the proposed built -upon area and ensure that the runoff from all the built -upon is directed into the permitted system. 14. The Director may notify the permittee when the permitted site does not meet one or more of the minimum requirements of the permit. Within the time frame specified in the notice, the permittee shall submit a written time schedule to the Director for modifying the site to meet minimum requirements. The permittee shall provide copies of revised plans and certification in writing to the Director that the changes have been made. 15. The permittee must maintain the current permitted drainage area. No additional runoff from outside of the pen-nitte& drainage area boundary may enter the permitted stormwater facilities without first applying for and receiving a permit modification. 111. GENERAL CONDITIONS This permit is not transferable except after notice to and approval by the Director. In the event of a change of owership, or a name change, the permittee must submit a formal permit transfer request to the Division of Water Quality, accompanied by a completed name/ownership change form, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. The permittee is responsible for compliance with all permit conditions until such time as the Division approves the transfer request. 2. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to enforcement action by the Division of Water Quality, in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. 3. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 4. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement stormwater management systems. 5. The permittee grants DENR Staff permission to enter the property during normal business hours for the purpose of inspecting all components of the permitted stormwater management facility. 6. The permit may be modified, revoked and reissued or terminated for cause. The filing of a request for a permit modification, revocation and reissuance or termination does not stay any permit condition. State Stormwater Management Systems Permit No. SW8 030322 7. Unless specified elsewhere, permanent seeding requirements for the stormwater control must follow the guidelines established in the North Carolina Erosion and Sediment Control Planning and Design Manual. 8. Approved plans and specifications for this project are incorporated by reference and are enforceable parts of the permit. 9. The permittee shall notify the Division any name, ownership or mailing address changes within 30 days. Permit issued this the 7th day of July, 2003. NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION L Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission 6 State Stormwater Management Systems Permit No. SW8 030322 Golden Sands / Sandfiddler Motel Stormwater Permit No. SW8 030322 New Hanover County Designer's Certification 1, , as a duly registered in the State of North Carolina, having been authorized to observe (periodically/weekly/full time) the construction of the project, (Project) for (Project Owner) hereby state that, to the best of my abilities, due care and diligence was used in the observation of the project construction such that the construction was observed to be built within substantial compliance and intent of the approved plans and specifications. The checklist of items on page 2 of this form is included in the Certification. Noted deviations from approved plans and specification: SEAL Signature Registration Number Date State Stormwater Management Systems Permit No. SW8 030322 Certification Requirements: l . The drainage area to the system contains approximately the permitted acreage. 2. The drainage area to the system contains no more than the permitted amount of built -upon area. 3. All the built -upon area associated with the project is graded such that the runoff drains to the system. 4. The outlet/bypass structure elevations are per the approved plan. 5. The outlet structure is located per the approved plans. b. Trash rack is provided on the outlet/bypass structure. 7. All slopes are grassed with permanent vegetation. 8. Vegetated slopes are no steeper than 3:1. 9. The inlets are located per the approved plans and do not cause short-circuiting of the system. 10. The permitted amounts of surface area and/or volume have been provided. 11. Required drawdown devices are correctly sized per the approved plans. 12. All required design depths are provided. 13. All required parts of the system are provided, such as a vegetated shelf, and a forebay. 14. The overall dimensions of the system, as shown on the approved plans, are provided. cc: NCDENR-DWQ Regional Office New Hanover County Building Inspections -D t Design / Andrew and Kuske Sh1eet 902 Market St. CONSULTING ENGINEERS, INC. Wilmington, N,C, 28401 / Of Check Job ,!- %p� jf��/�� For Job No. 07 Cl58 / 7r� x �5/,, O it - >'� /' Z5 r-rJ 2- J-7 x , �-/, 1t-(/--58 FT sc C 50 o Dot Design Andrew and Kuske Sheet / CONSULTING ENGINEERS 902 Market St. , INC. Wilmington, N.C. 28401 / pt Check Job �r�y�W� �.L-/ For 4,�,��� Job No. cz�.�s SQ.•LJr:' �;�•=tom. ��. � 22� 1 ce-:W5 7 /Z (.o F 3 /3 5 7r�c-.✓c.� x SLAT 3 , Fr Fr , c f- log . �Z FT 3 �'- , Z F-7- x oe;;,V akl—� .� G✓may- 5� O � � , ' 7- 22, r-7) 15 Fr) , ,� t C (� Z9 r-r X 11 j5 �r z J) t% x cl�Fr %C Z�5 G7) j-0 fT3 �z'51- rr 3 1156 d re. Dot Design Andrew and Kuske Sheet �13 � 902 Market St, CONSULTING ENGINEERS, INC. Wilmington, N.C. 28401 / of Check Job �%��i�-�>l' For GrjL .� ,�,�5/ sob No, 45,6'5 ! _5 C- r — (/8 rT X i7'C ,1 15 7X' /Z� (.o'7tl F3 7 - /3 6 �Ti �✓�.�% <2 0 , 2 �T -5 , / 5 r— r) r FrJ30 FT" V FT 3, � FT r /�d , c� 108 � S� j 7` 9?-?, Z r-r; F-T3 -el-V 04� S7-022C&E Tom— CP : 2'�Z x— I� ZOCo �T �` // g 1 ') Cf z K1011 77715t4# X (b 25 PT FT ) r—r) Z-q r-r >4 71 (�/ �5 r-7 x- /, r-7-) '7, ee -3) '7, 5 1-3 r- - � -' 50 04 - Andrew & Kuske CONSULTING ENGINEERS, INC. 902 Market Street Wilmington, NC 28401-4733 910/343-9653 910/343-9604 Fox www,ondrewandkuske.com July 1, 2003 Ms. Laurie Munn NC DENR Division of Water Quality 1 Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: Golden Sands 1 Sandfiddler Motel SW8 030322 A & K Project No. 02291 Dear Ms. Munn: John R. Andrew, P.E. John S. Tunstall, RE, John A. Kuske, III, P.E. James T. Pyrtle, P.E. We are responding to your faxed comments of June 27, 2003 as follows: J. Phillip Norris, P.E. Neal W. Andrew, P.E. J.A. Kuske, P.E. of Counsel C. Lawrence Sneeden, Jr., P.E. 11 I Y E D J U L 0 12003 1. We have eliminated the bypass structure on the west side and have redesigned the system to contain the first 2 inches of runoff. 2. We concur with the SHWT on the west and east sides and have designed the systems accordingly. 3. The systems have both been designed to contain the first 2 inches of runoff. No bypasses are required. 4. Please call me to discuss the drainage of the area. All runoff is directed to the infiltration basin. We are enclosing two (2) sets of revised plans, SWU-107 application forms and calculations for your continued review and approval. Please contact us if you have any further questions or comments. Thank you for your assistance on this project. Sincerely, ANDREW & KUSKE C NSU G E GINEERS, INC 4 J. hills orris, P.E. J N/asn 02291 07-01-03-s-sw-response-Itr Andrew & Kuske CONSULTING ENGINEERS, INC. John R. Andrew, P.E. J. Phillip Norris, P.E. 902 Market Street Wilmington, NC 2W1-4733 John S. Tunstall, RE. Neal W. Andrew, P.E. John A. Kuske, III, P.E. J.A. Kuske, P.E. of Counsel 910/343-9653 910/343-9604 Fax www.ondrewandkuske.com James T. PWrtle, P.E. C. Lawrence Sneeden, Jr., P.E. June 25, 2003 Ms. Laurie Munn NC DENR Division of Water Quality / Water Quality Section 127 Cardinal Drive Extension Wilmington, NC 28405-3845 z �� Re: Golden Sands / Sandfiddler Motel SW8 030322 BFEnn�.'Q• Review Comments7� A & K Project No. 02291 <` Dear Ms. Munn: We are responding to your comments of May 21, 2003 as follows: 1. It is our understanding that Vincent Lewis has been on site. 2. The vicinity map shows the intersection of the closest major roads, which are NC 132 and US 421 at Monkey Junction. 3. The area has been modified to show a connection to the trench drain. 4. More detail has been added as stated in item #3 above. 5. Building dimensions have been added. 6. It is our understanding that the system drains to the Cape Fear River. 7. We have designed the system to contain the first 1.5 inches of runoff. The system will bypass any runoff in excess of the amount. We do not anticipate that the systems will bypass any runoff, as our calculations indicate they can handle a 50- year storm without doing so. 8. Bypasses are provided. The west area overflows to existing swales on the northwest corner of the site. The east area overflows to existing storm drains on South Lake Park Blvd. The supplements have been revised and are enclosed. 9. The maintenance agreements have been modified to show the 75% design depth. We are enclosing two (2) sets of revised plans and calculations for your continued review and approval. Please contact us if you have any further comments. Thank you for your assistance on this project. Sincerely, NDR �� KE C ULTI GJNE . JjPhillip Norris, P.E. 02291 06-25-03-s-sw-response-Itr �OF WA7FR 0 � Mr. Arnmy Pope, Partner Golden Sands Motel, LLC 1211 S. Lake Park Blvd. Carolina Beach, NC 28428 Dear Mr. Pope: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, REJ)irector Division -of -Water -Quality May 21, 2003 Subject: REQUEST FOR ADDITIONAL INFORMATION Ston-nwater Project No. SW8 030322 Golden Sands / Sandpiper Motel New Hanover County The Wilmington Regional Office received a Stormwater Management Permit Application for Golden Sands / Sandpiper Motel on March 28, 2003. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: Please contact me to make arrangements for Vincent Lewis to do the soils investigation. If he has already been to this site, please advise. 2. Please add the nearest intersection of two major roads to the vicinity map. A major road is any 1, 2 or 3 digit NC, US or interstate highway. Please add some additional spots to the western entrance on Tennessee Avenue. It appears that some of the built -upon area may not be entering the pond. Please provide more detail of the trench drain on the East Area plan. Show how this area enters the infiltration trench. Please provide dimensions on the buildings. 6.1 Please verify that the site is draining to the Cape Fear River in this area. Portions of the project may be draining to the Atlantic Ocean. Please show in your calculations how you determined the design volume for the storm event. Your design volume is the entire volume of runoff for the storm event. Peak flow volumes are not acceptable. Please provide a bypass for the system. If you are not able to provide a bypass, please design your system using the 2" storm as the design storm. Revise your calculations to show that your system can infiltrate the entire volurne from the design storm. Also, please revise the Trench Design Parameters on the supplement to reflect the 2" storm event. 9. Please revise your maintenance agreements to show that the sediment is to be cleaned out when the trench is reduced to 75% of the design depth. 1 N. C.'Division of Water Quality 127 Cardinal Drive Extension (910) 395-3900 Customer Service -- Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 NO)ENR Mr. Jimmy Pope May 21, 2003 Golden Sands / Sandpiper Motel Please note that this request for additional information is in response to a preliminary review. The requested -information should be received by this Office prior to June 21, 2003, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, Laurie Munn Environmental Engineer RSS/:Ism SAWQSISTORMWAMDD1NFO12003\030322.may03,doe cc: Laurie Munn Phil Norris, P.E. ~� UY J Z. c• Barnhill Contracting 321 North Front Street Wilmington, North Carolina 28401 Attention: Mr. Bruce McGuire June 6, 2002 Reference: Double -Ring Infiltrometer Testing Proposed Golden Sands Hotel Carolina Beach, North Carolina Job No. 1061-02-149 Dear Mr_ McGuire: As requested, S&; ME personnel bave recently conducted double -ring infiltrometer testing of the surficial soils at the subject site at the approximate location shown in Figure I. Spemfic4ly, our representatives performed the following work iter s on Rine 5, 2002, 1. Advanced one hard-augelred boring near the double -ring mfikaometer test location m order to visually classify the in -place soils. A Munseli Soil Color Chart was used to define the hue and cbroma of the recovered soil samples. 2. Conducted one double -Ting bahltrlameter test at a depth of approxunately 12 inches below the existing ground surface. Tbis testing was conducted in general accordance with American Society far Testing and Materials (AS7M) procedure .D 3385 entitled, "lufltration. Rate of Soils in Field Using Double -leg Infiltrometer". The in plaoe sons at the infiltrometer test location, generally consist of either clez►ra sands or slightly silty sands that extend to the completed boring depth of 9 feet below the eXisting ground surface. Water was noted in the borehole at the time of our field testing work at a dqAh of 8.9 feet below the existing ground swf'ace. S8ME, Inc. 6409 Amsterdam Wvy, $vilding 63 j Wlilm+nalon, North Coroh"' 28405 TI IIJ—F.—PGIRP THI I RP -.PRPM Tf). AII)Pi=l.d+k H'zVt (910) 799.9945 (9101 799-W58 6x I www.sneeinc.cam f �. �. .., c. .�-i..... ..,..,..-.., az..i, rraa..-.a.«...v.. av-:%lKi ftl'-3tla Z)O ' t'HGjr— L/-4 Bamhill Contracting June 6, 2002 Wage Two The measured infiltration rates at the test location ganged from about 63 to 66 inches per hour, with an average ui ilfr&on rate of approximately 65 inches per hour. A summary of the field test results is presented in Table 1. S&ME appmr is m Oae opporMnaity to provide oux- ser% ices during this phase of the project. Should you have any questions after review ng this letter, or if we can be of additional assistance, please do not hesitate to contact us at your convenienm very truly yours, S&M INC. Steven D.- Kelly. Branch Manager Michael W. BehM P.E. Senior Gootechmzcal Enginoor SDY,MWBljns Attachments Copy: Andrew & Kmske Cons un g En�gim=s, W_ Phil Norris, P.E_ :3/4 i TABLE 1 Double leg Infiltrometer Testing Proposed Golden Sands Hotel Carolina Beach, North Carolina Job No. 1061-02-149 Locakion: 1 Date of Test: Jame 5, 2002 Depth. of Test Below Site Grade: 12 inches Depth of Water in Rings: b inches Inner Diameter of inner Ring: 11'14 inches Imer Diameter of Outer : 22Y, inches Depth to Groundwater. 8.9 feet Average Infiltration Rate: 65 inchv-flour Depdi Hue VaInChroma 0-3" 25 Y 512 3"-5" 10 YR 313 5"-18" 26 Y 413 18"-30" 2.5 Y 513 30"45" 2.5 Y 4/1 36"-46" 25 Y 6/1 46"-60" to YR 4/3 60"-74" 10 YR 2/2 74"-87" 10 YR 3/1 87"-145" 25 Y 6/1 S611 Profile Sail Dcrivtian Greyish Brown Fine to Medium SAND — Trace of Silt. Dark Brown Fine to Medium SAND -- Trace of Silt with Rock' Olive Brown Fine to Medium SAND — Trace of Silt Light Olive Brown Fine to Medium SAND — Tmoo of Silt Dark Gray Fine to Medium SAND — Trace of Silt Gray Fine to Medium SANK —Trace of Sflt Brown Fine to Medium SAND — Trace of Silt Very Dark Brown Fine to Medium SAND Trace of Silt Very Dark Gray Fine to Medium SAND — Trace of Silt Gray Fine to Medium SAND —Trace of Silt k,.o.�.��oa�o rMUc _..4 Get Driving Directions cam_ ~ =`�/ �� Page 2 of 3 0.26 miles to US-17 (Market St) 0.88 miles Southeast of RAM P. 2 ...................................................................................................................................................................... Go West on US-17 (Market St) for 0.88 miles to NC-132 0.9 mile S (College Rd) 3 You will see a sign reading "NC-132 S" 4 Turn left on ramp to NC-132 S (College Rd) and merge 0.4 mile with caution 5 Continue onto NC-132 S (College Rd) and go South for 7.3 mile 7.3 miles to US-421 S (Carolina Beach Rd) ..................................................................................................................................................................... 6 Continue onto US-421 S (Carolina Beach Rd) and go 6.5 mile South for 6.5 miles to US-421 (N Lake Park Blvd) 7 Continue onto US-421 (N Lake Park Blvd) and go South 1 mile for 0.98 miles to US-421 (S Lake Park Blvd) 8 Continue onto US-421 (S Lake Park Blvd) and go South 1.2 mile for 1.2 miles to 1211 S Lake Park Blvd,Carolina Beach,NC ...................... ............................................................ I ............................ ................................................. .... 9 ................................................................................................................................................................................... You are at 1211 S Lake Park Blvd,Carolina Beach,NC destination 1211 S Lake Park Blvd Carolina Beach, NC 28428-5522 1E�� Cape. Fear o, .vjGrePh 11 �21 s n Catalina & r a�ds,Dt : r r' 1639 jcarpf ha 211: S lake PaHi'Bl�il' ri 3r y rho aaa Q m2903 xar4:ncpaOg.ramIn.. CM2•GOT nc Click here or on the map above for an adjustable version. C r • http://www.randmenally.com/rmc/directions/dirGetDirections.j sp?BV_SessionID=@@@@... 6/2/2003 Get Driving Directions Page 1 of 3 Local information rr: rti x; Construction c`�i Places to Stay. Wilmington Weather Carolina Beach » Weather More Options Get driving_ directions to another location Get mileage between two locations in the us _. Hide labels Customize your directions Plan your Road Trip now! Use this starting point and destination to plan a complete Road Trip, including: • Stops along the way • Things to do • Places to stay From.. : 127 Cardinal Drive Ext Wilmington, NC 28405-5406 qzy To: 1211 S Lake Park Blvd Carolina Beach, NC 28428-5522 a print M save ® emai Lake Park Blvd Click here_ or on the map above for an adjustable version.n�-F-- Find it in the 2003 Road Atlas sec Wilmington, NC Carolina Beach, NC C!� • page 75, Wilmington detail map page 75, grid section K-14 • page 75, grid section 1-14 your trip information We've found the fastest route for you. For more options, click here. Find out more about our online mapping. ,,Show step-by-step maps t4b Show return directi Estimated Total Driving Time: Estimated Total Driving Distance: Total Number of Step 26 minutes 17 miles 9 step directions distant 1 We found 127 Cardinal Drive Ext,Wilmington,NC but are unable to start the directions from this location. We suggest that you consult a map and take local roads http://www.randmenally.com/rme/directions/dirGetDirections.isp?BV_SessionID=@@@@... 6/2/2003 P. 1 COMMUNICATION RESULT REPORT ( JUN. 3.2003 12:06PM ) TTI NCDENR WIRO FILE MODE OPTION ADDRESS (GROUP) RESULT PAGE ------------------------------------------------------------------------------------------------ 893 MEMORY TX 9-3439604 OK P. 1/1 REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-3) NO ANSWER E-2) BUSY E-4) NO FACSIMILE CONNECTION FAX COVER SHEET Date: June 3, 2003 No. of Pages: 1 To: Phillip Norris From: Laurie Mann Company: Andrew & Kuske Water Quality Section - Stormwater FAX #: 910.343.9604 FAX # 910-350-2004 Phone # 910-395.3900 D'WQ Stormwater Project Number: SW8 030322 Project Name: Golden Sands/Sandfiddler Motel MESSAGE: Mt. Norris, Vincent Lewis and I did a soils investigation yesterday at the site. Mr. Lewis performed the test on the Sandfiddler side. He hit water at approximately 50". This is much shallower than the original soils investigation indicates. The original investigation was done in June 2002, during a dry year. The infiltration system must Have at least 2' between the bottom of the system and the water table. The Golden Sands side is not affected by this, but the Sandfiddler side is, Please call me with any questions. Thanks, Laurie Munn FAX COVER SHEET Date: June 3, 2003 No. of Pages: 1 To: Phillip Norris From: Laurie Munn Company: Andrew & Kuske Water Quality Section - Stormwater FAX 9: 910.343.9604 FAX # 910-350-2004 Phone # 910-395-3900 DWQ Stormwater Project Number: SW8 030322 Project Name: Golden Sands/Sandfiddler Motel MESSAGE: Mr. Norris, Vincent Lewis and I did a soils investigation yesterday at the site. Mr. Lewis performed the test on the Sandfiddler side. He hit water at approximately 50". This is much shallower than the original soils investigation indicates. The original investigation was done in June 2002, during a dry year. The infiltration system must have at least 2' between the bottom of the system and the water table. The Golden Sands side is not affected by this, but the Sandfiddler side is. Please call me with any questions. Thanks, Laurie Munn S:\WQS\STORMWAT\ADDINFO120031030322.iuneO3 P. 1 COMMUNICATION RESULT REPORT ( MAY.21.2003 11:44AM ) TTI NCDENR WIRO FILE DIODE OPTION ADDRESS (GROUP) RESULT— ------ PAGE----- ------------------------------------------------------ — _ ---- MEMORYTX------------- 9-3439604 OK P. 3/3 REASON FOR ERROR E-2) BUSY E-1) HANG UP OP, LINE FAIL E-4) NO FACSIMILE CONNECTION E-3) NO ANSWER State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor William G. Ross Jr., Secretary FAX COWER SHEET Date: J 12,i % 03 No. Of Wages: To; T;�� t o r r r 'C From: AA rl CO:A FAX #: REMARKS SEEP co: Div 1p-_ I (o Qq FAX##:910-350-2004 127 Cardinal Drive Extension, Wilmington, N.C. 28405-3845 Tefepfmne (910) 39S-3904 Pax (910) 350.200d An Equal Opportunity AMrmative Action Employer v U O � � V ozd Ucl � o O a) z g O � � coo w O CC GJ Q Fig r W x W O V a 04M m 0 rn K ri 0 rn rn P. 1 FILE —MODE ------_-----OPTIO 565 MEMORY T COMMUNICATION RESULT REPORT ( MAY.21.2003 11:34AM ) TTI NCDENR WIRO N__ _ _ _________ ADDRESS —(GROUP)-----_-----------RESULT---------PAGE__ — — — 9-3413030 OK P. 3/3 REASON FOR ERROR E-1) HANG UP OR LINE FAIL E-2) BUSY E-3) NO ANSWER E-4) NO FACSIMILE CONNECTION State of North Carolina Department of Environment and Natural Resources Wilmington Regional Office Michael F. Easley, Governor Willi= G, Ross Jr., Secretary FAX COVER SKEET Date: ;5f 2 f 103 No. Of Pages: To: F>UCAA From: u!'i !1/L- n CO: CO: rJ (- _. FAX #; ! 0 3 1 - a FAX#: 910-350-2004 REMARKS 127 Cardinal Drive Extension, Wilmington, N.C. 284054845 Telephone (910) 395-3900 Fax (910) 350-2004 An Equal Opponunity ARirmatIve Action Employer 7 ►� .k W 0 V I 0 a st L% 0 O a ri in o� � u o�oF wA�-FRQG r S Mr. Jimmy Pope, Partner Golden Sands Motel, LLC 1211 S. Lake Park Blvd. Carolina Beach, NC 28428 Dear Mr. Pope: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E.,Director Division -of -Water -Quality May 21, 2003 Subject: REQUEST FOR ADDITIONAL INFORMATION Stormwater Project No. SW8 030322 Golden Sands / Sandpiper Motel New Hanover County The Wilmington Regional Office received a Stormwater Management Pert -nit Application for Golden Sands / Sandpiper Motel on March 28, 2003. A preliminary review of that information has determined that the application is not complete. The following information is needed to continue the stormwater review: ]. Please contact me to make arrangements for Vincent Lewis to do the soils investigation. If he has already been to this site, please advise. Please add the nearest intersection of two major roads to the vicinity map. A major road is any 1, 2 or 3 digit NC, US or interstate highway. Please add some additional spots to the western entrance on Tennessee Avenue. It appears that some of the built -upon area may not be entering the pond. Please provide more detail of the trench drain on the East Area plan. Show how this area enters the infiltration trench. Please provide dimensions on the buildings. 6. Please verify that the site is draining to the Cape Fear River in this area. Portions of the project may be draining to the Atlantic Ocean. 7. Please show.in your calculations how you determined the design volume for the storm event. Your design volume is the entire volume of runoff for the storm event. Peak flow volumes are not acceptable. Please provide a bypass for the system. If you are not able to provide a bypass, please design your system using the 2" storm as the design storm. Revise your calculations to show that your system can infiltrate the entire volume from the design storm. Also, please revise the Trench Design Parameters on the supplement to reflect the 2" storm event. 9. Please revise your maintenance agreements to show that the sediment is to be cleaned out when the trench is reduced to 75% of the design depth. 4, w N. C.'Division of water Quaiity 127 Cardinal Drive Extension (910) 395-3900 Customer Service �d Wilmington Regional Office Wilmington, NC 28405 (910) 350-2004 Fax 1 800 623-7748 14CDENiR Mr. Jimmy Pope May 21, 2003 Golden Sands 1 Sandpiper Motel Please note that this request for additional information is in response to a preliminary review. The requested information should be received by this Office prior to June 21, 2003, or the application will be returned as incomplete. The return of a project will necessitate resubmittal of all required items, including the application fee. If you need additional time to submit the information, please mail or fax your request for a time extension to the Division at the address and fax number at the bottom of this letter. The request must indicate the date by which you expect to submit the required information. The Division is allowed 90 days from the receipt of a completed application to issue the permit. The construction of any impervious surfaces, other than a construction entrance under an approved Sedimentation Erosion Control Plan, is a violation of NCGS 143-215.1 and is subject to enforcement action pursuant to NCGS 143-215.6A. Please reference the State assigned project number on all correspondence. Any original documents that need to be revised have been sent to the engineer or agent. All original documents must be returned or new originals must be provided. Copies are not acceptable. If you have any questions concerning this matter please feel free to call me at (910) 395-3900. Sincerely, G� Laurie Munn Environmental Engineer RSSl:lsm S:1WQSlSTORMWATIADDINF'O12003\030322.may03.doc cc: Laurie Munn Phil Norris, P.E. Andrew & Kuske CONSULTING ENGINEERS, INC, 902 Market Street Wilmington, NC 28401-4733 910/343.9653 910/343-9604 Fax -= www.andiewandkuske.com March 27, 2003 Ms. Linda Lewis, Environmental Engineer NC DENR Division of Water Quality 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re: State Stormwater Permit Submittal Golden Sands 1 Sandfiddler Motel Carolina Beach, NC A & K Project No. 02291 Dear Ms. Lewis: John R. Andrew, P.E. J. Phltllp Norris, P.E. John S, Tunstall, P.E. Neal W. Andrew, RE. John A. Kuske, III, P.E. J.A, Kuske, P.E. of Counsel James T. PyrtleyTP.E. C. Lawrence Sneeden, Jr., P.E. + � E ll 7D MAR 2 8 2003 BY: 4233-4- Enclosed are two (2) sets of plans for the subject project, one (1) set of calculations, the original Division of Water Quality Stormwater Management Permit application, the original SWU-107 supplement forms, one (1) copy of the stormwater narrative, one (1) copy of the geotechnical report from S&ME and a $420.00 check for the processing fee. Please review this information for approval and contact us with any questions or comments you may have. Thank you for your assistance on this project. Sincerely, ANDREW SKE CONSUL G NGINEERS, J. P illip orris, P.E. JPN sn 2291 03-27-03-s-sw-ltr Enclosures cc: Jimmy Pope