Loading...
HomeMy WebLinkAbout20070524 Ver 1_More Info Received_20070508., Hobbs, Upchurch & Associates, P.A. Consulting Engineers 300 S.W. Broad Street Southern Pines, NC 28388 May 7, 2007 Mr. Ian McMillan, 401 Coordinator Division of Water Quality 401 /Wetlands Unit 1650 Mail Service Center Raleigh, NC, 27699-1650 Re: NW-12 Permit Application -Response to Comments DWQ Project No. 07-0524 Pinehaven Water Main Replacement Project -Davidson County, NC HUA No: DE 0507.300 Permits Dear Sir, ~~ ~ ~ ~ 7 _ ~"•c ~ ,~ '' <. I a;~ l;` Ev~AY ~ ZQ~ 7 JAS=`TI M~l~a' ~,'IL. i ~ E 4 f'' ~'.•i~.~v~til.l1 On behalf of Handy Sanitary District, please find the responses to the comments raise in your letter dated. April 3, 2007. An email was sent containing all of these responses, including the requested AutoCad files for the stream crossing details, on April 11, 2007. Per your regwuest, a hard copy on our letterhead is provided for your records. Please show all stream impacts including all fill slopes, dissipaters, and bank stabilization on the site plan. Please clearly indicate exact impact length of each stream. Reynolds Creek appears to be 40' on Sheet W1,1 and 60' on Sheet W1,2, yet the PCN indicates there will be 30' total of impact at two locations (15' each). Please indicate the existing Waterman corridors and the proposed Waterman corridors on the plan. These two creek crossings are approximately 15' wide each (bank to bank). Please reference the revised sheets attached to this email for better details of these crossings. 2. Is there the possibility of more taps to the new line? If yes, Section XN (impacts) needs to be modified. If not, then this should be stated as well. No. All water mains are 6-inch replacements of existing 2-inch water mains that are in violation ofP[l~S regulations (more than 10 residences on a 2"main; 2"maims greater than 1, 000 feet rn length). The 8" water main along Blaine Road is a critical hydraulic loop that will improve the operation of the HSD water system and prevent operating pressures from dropping below the Pt~S-mandated 20 psi minimum. New water taps will be allowed to connect to these waterline replacements/installations due to the pre-existence of vacant subdivided lots located within the Pinehaven community. Property owners who wish to build on the frnite number of vacant lots along the proposed water main routes (most of which are dead-end streets) currently have access to public water and the ability to connect to these water mains. The replacement ofaging/small diameter waterlines will not result in cumulative impacts. Southern Pines, NC .Telephone 910-692-5616 .Fax 910-692-4795 .email: bsexton@hobbsupchurch.com Hampstead . Nags Head . Charlotte .Beaufort Page 2 of 2 The installation of the proposed 8" water main along Blaine Road immediately north of the Pinehaven community is intended to provide the Handy Sanitary District's water system with the improved ability to transfer water to its existing water customer base at Badin Lake. The proposed water main will span between existing water service areas and is intended to benefit these service areas through the installation ofa critical hydraulic loop. All available water-front lands at Badin Lake have been heavily disturbed through community development for many years and are part of the existing HSD water system service area. 3. Please submit electronic CAD files showing the two 15' stream impacts, via email to ian.mcmillan(a~ncmail.net and on CD. Attached to the email sent to you on Apri111, 2007 are AutoCad 2004 files of the applicable plan sheets and stream crossing details (extract all files to the same folder). The Stream Bank Stabilization detail, included on Sheet EC-2 in the original submittal, is a detail applicable at these two creek crossings and is referenced on these revised plan sheets. If these responses address the concerns in your letter, I will have the District execute a revised application and sign/seal/date the revised plan sheets (5 copies to 401 Unit). Please feel free to contact me at this office should you have any questions or require additional information for review of this application. TES, P.A. Enclosures Cc: Mr. Ron Niland, General Manager, Handy Sanitary District Ms. Cyndi Karoly, 401 Unit Supervisor h: Ide05071300 - permittinglwetlandsldwq OS-07-07.doc