HomeMy WebLinkAboutWQ0018204_Permit (Issuance)_200006301
State of North Carolina
Departrrient of Environment
and Natural Resources
Division of Water Quality
James B. Hunt, Jr., Governor
Bill Holman, Secretary
Kerr T. Stevens, Director
RECEIVED
lJ(II 1 3 2000
FA/ ITEVILLE
REG. OFFICE
Honorable Kenneth R. Kornegay, Mayor
Town of Elizabethtown
P. O. Box 716
Elizabethtown, North Carolina 28337-0716
Dear Mayor Kornegay
June 30, 2000
Av41711.
CDENR
NORTH CAROLINA DEPARTMENT OF
ENVIRONMENT AND NATURAL RESOURCES
Subject: Permit No. WQ0018204
Town of Elizabethtown
FY '99 CDBG Project, Blueberry Hill
Wastewater Collection System
Bladen County
In accordance with your application received March 24, 2000, and additional information
received June 7, 2000, and June 23, 2000, we are forwarding herewith Permit No. WQ0018204 dated
June 30, 2000, to the Town of Elizabethtown for the construction and operation of the subject wastewater
collection extension. This permit shall be effective from the date of issuance until rescinded and shall be
subject to the conditions and limitations as specified therein.
Please pay particular attention to Condition 14 which states that all wells within 100 feet of the
sewer line shall be properly abandoned per groundwater standards upon the completion of this project.
The engineer's certification of the completion of this project shall be considered as an affirmation that
this has been completed.
Permitting of this project does not constitute an acceptance of any part of the plans and
specifications that do not meet 15A NCAC 2H .0200 and the Division of Water Quality's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996 unless specifically mentioned herein. Division
approval is based on the acceptance of the certification provided by a N.C. Professional Engineer on
Page 6 of the subject permit application form. It shall be the permittee's responsibility to ensure the
plans and specifications meet the appropriate design criteria and rules. Failure to comply may result in
penalties in accordance with North Carolina General Statute 143-215.6A — 143-215.6C, construction of
additional facilities, and/or referral of the N.C. Professional Engineer to the licensing board.
If any parts, requirements, or limitations contained in this permit are unacceptable, you have the
right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of
this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the
North Carolina General Statutes, and filed with the Office of Administrative Hearings, 6714 Mail Service
Center, Raleigh, NC 27699-6714. Unless such demands are made this permit shall be final and binding.
1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone (919) 733-5083 Fax (919) 715-6048
An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper
One set of approved plans and specifications is being forwarded to you. If you need additional
information concerning this matter, please contact Mr. Bennie Goetze, Jr., P. E. at (919) 733-5083
extension 362.
Si
,./Kerr T. Stevens
cc: Bladen County Health Department
Fayetteville Regional Office, Water Quality Section (Elizabethtown WWTP, NC0026671)
The Wooten Company
s
NORTH CAROLINA
ENVIRONMENTAL MANAGEMENT COMMISSION
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
RALEIGH
WASTEWATER COLLECTION PERMIT
In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended,
and other applicable Laws, Rules, and Regulations
PERMISSION IS HEREBY GRANTED TO
Town of Elizabethtown
Bladen County
FOR THE
construction and operation of approximately 5,283 linear feet of 8-inch gravity sewer; approximately 816 linear
feet of 18-inch gravity sewer; a 30-GPM pump station with duplex pumps, on -site audible and visual high water
alarms with autodialer and standby portable generator; a 100-GPM pump station with duplex pumps, on -site
audible and visual high water alarms with autodialer, and standby portable generator; approximately 393 linear
feet of 2-inch force main; and approximately 1,665 linear feet of 4-inch force main to serve Blueberry Hill —
Peanut Road Areas (18 lots), and the discharge of 6,480 GPD of collected domestic wastewater into the Town of
Elizabethtown's existing sewerage system, pursuant to the application received March 24, 2000, and in
conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the
Department of Environment and Natural Resources and considered a part of this permit.
This permit shall be effective from the date of issuance until rescinded and shall be subject to the following
specified conditions and limitations:
1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of
this permit, 15A NCAC 2H .0200, the Division of Water Quality's Gravity Sewer Minimum Design
Criteria adopted February 12, 1996, the approved plans and specifications, and other supporting data unless
specifically mentioned herein.
2. This permit is effective only with respect to the nature and volume of wastes described in the application
and other supporting data.
3. The facilities must be properly maintained and operated at all times.
4. The sewage and wastewater collected by this system shall be treated in the Town of Elizabethtown's
Wastewater Treatment Facility (Ncoo26671) prior to being discharged into the receiving stream.
5. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there
is a name change of the Permittee, a formal permit request must be submitted to the Division of Water
Quality (Division) accompanied by documentation from the parties involved and other supporting materials
as may be appropriate. The approval of this request will be considered on its merits and may or may not be
approved.
1
6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service
by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of
the State.
7. Upon completion of construction and prior to operation of this permitted facility, a certification and a
copy of the record drawings (i.e., as -constructed plans) must be received from a professional engineer
certifying that the permitted facility has been installed in accordance with the Division's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996, 15A NCAC 2H .0200, this permit, and other
supporting materials. If this project is to be completed in phases and partially certified, you shall retain the
responsibility to track further construction approved under the same permit and provide a final certificate of
completion once the entire project has been completed. A copy of the record drawings, indicating the
facilities constructed in the phase being certified, shall be submitted with each partial certification. Mail the
Certification and one (1) copy of the record drawings to the Non -Discharge Permitting Unit, 1617 Mail
Service Center, Raleigh, NC 27699-1617.
8. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum
of five years from the date of the completion of construction.
9. Failure to abide by the conditions and limitations contained in this permit or to construct the facilities in
accordance with the conditions of this permit, 15A NCAC 2H .0200, the Division's Gravity Sewer
Minimum Design Criteria adopted February 12, 1996, the approved plans and specifications, and other
supporting data may subject the Permittee to an enforcement action by the Division, in accordance with
North Carolina General Statute 143-215.6A to 143-215.6C.
10. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules,
regulations, or ordinances which may be imposed by other government agencies (local, state, and federal)
which have jurisdiction.
11. The Permittee shall provide for the pump station and force main the following items:
a. Pump on/off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump
station,
b. An air relief valve located at all high points along the force main,
c. A screened vent for the wet well,
d. Fillets located in the wet well at the intersection of the flooring and sidewalls,
e. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet
cannot be maintained,
f. Sufficient devices which will protect the pump station from vandals, and
g. Flood protection if the pump station is located below the 100-year flood elevation.
h. Adherence with the following minimum separations:
(i) Storm sewers (vertical) 12 inches
(ii) Water mains (vertical -water over sewer) 18 inches or (horizontal) 10 feet
(iii) In benched trenches (vertical) 18 inches
(iv) Any private or public water supply source, including any WS-I waters or Class I or Class II
impounded reservoirs used as a source of drinking water 100 feet
(v) Waters classified WS (other than WS-I), B, SA, ORW, HQW, or SB [from normal high water (or
tide elevation)] 50 feet
(vi) Any other stream, lake or impoundment 10 feet
(vii) Any building foundation 5 feet
(viii) Any basement 10 feet
(ix) Top slope of embankment or cuts of 2 feet or more vertical height 10 feet
(x) Drainage systems
(I) Interceptor drains 5 feet
(II) Ground water lowering and surface drainage ditches 10 feet
(xi) Any swimming pool 10 feet
2
4
(xii) Ferrous sewer pipe with joints equivalent to water main standards, shall be used where these
minimum separations cannot be maintained. The minimum separation shall however not be less
than 25 feet from a private well or 50 feet from a public water supply well;
12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the
Permittee shall take immediate corrective action, including those as may be required by this Division, such
as the construction of additional or replacement wastewater collection facilities.
13. NONCOMPLIANCE NOTIFICATION:
The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (910) 486-
1541, as soon as possible, but in no case more than 24 hours or on the next working day following the
occurrence or first knowledge of the occurrence of either of the following:
a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of
adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or
breakage, etc.; or
b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters
without treatment of all or any portion of the influent to such station or facility.
Persons reporting such occurrences by telephone shall also file a written report in letter form within five (5)
days following first knowledge of the occurrence. This report must outline the actions taken or proposed to
be taken to ensure that the problem does not recur.
14. All wells within 100 feet of the sewer line shall be properly abandoned per groundwater standards upon the
completion of this project. The engineer's certification of the completion of this project shall be
considered as an affirmation that this has been completed.
Permit issued this th0th day of June, 2000.
NORTH 1ZA[ROLINA NTAL MANAGEMENT COMMISSION
--Kerr T. Stevens, Director
Division of Water Quality
By Authority of the Environmental Management Commission
Permit Number WQ0018204
3
Permit No. WQ0018204
June 30, 2000
ENGINEER'S CERTIFICATION
Partial Final
I, , as a duly registered Professional Engineer in the State of
North Carolina, having been authorized by the Permittee to observe (periodically, weekly, full time) the
construction of the project,
Project Name Location and County
hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction
such that the construction was observed to be built within substantial compliance and intent of the Division of
Water Quality's Gravity Sewer Minimum Design Criteria adopted February 12, 1996, 15A NCAC 2H .0200, this
permit, the approved plans and specifications, and other supporting materials.
Signature Registration No.
Date
The above Engineer's Certification must be completed and submitted to the address below with one (1) copy of
the Record Drawings (i.e., as -constructed plans) of the permitted facilities. This project shall not be considered
complete and allowed to operate until this Engineer's Certification and the Record Drawings have been submitted.
Any wastewater flow made tributary to the permitted facilities prior to completion of this Engineer's Certification
shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions.
NORTH CAROLINA DEPARTMENT OF ENVIRONMENT & NATURAL RESOURCES
DIVISION OF WATER QUALITY
WATER QUALITY SECTION
NON -DISCHARGE PERMITTING UNIT
1617 MAIL SERVICE CENTER
RALEIGH, NORTH CAROLINA 27699-1617
4
MEMO TO:
FROM:
SUBJECT:
State Review Group
Ricky Revels
44 re) =
Procedure Four (4)
WQ0018204
Blueberry Hill & Peanut Road
Sewer Extension -Public
Town of Elizabethtown
Bladen County
Division of Water Quality
Fayetteville Regional Office
April 28.2000
Date
State Review Group Review
Engineer Mike Mortensen
Regional Office
Contact Ricky Revels
1) Name of wastewater treatment plant to receive the wastewater:
Town of Elizabethtown WWTP
2) WWTP design capacity 1.225 MGD
3) NPDES Permit No. NC0026671 Expiration Date: 5/31/2001
4) Compliance Information:
Present treatement plant performance for previous 12 months, beginning
(See attached self -monitoring data)
5) Quantity and type of wastewater from proposed sewers:
16.200 GPD
domestic 100% industrial
other
6) Volume from previously approved projects not yet tributary to WWTP:
-0- GPD
7) Regional
Recommendations: Approval X Denial
/rr
Enclosure
GKEX88/MP'
COMPLIANCE EVALUATION ANALYSIS REPORT
04/28/2000
PAGE 1
PERMIT--NC0026671 PIPE--001 REPORT PERIOD: 9901-9912 LOC---E
FACILITY--ELIZABETHTOWN, TOWN - WWTP DESIGN FLOW-- 1.2250 CLASS--3
LOCATION--ELIZABETHTOWN REGION/COUNTY--06 BLADEN
MONTH
50050 00310 00530 00610 31616 50060 00300 TGE6C
Q/MGD BOD RES/TSS NH3+NH4- FEC COLI CHLORINE DO FTHD24PF
LIMIT F .7000 F 30.00 F 30.0 NOL NOL NOL
99/01 .6371 12.61 10.8 .76 78.064 6.01
99/02
99/03
99/04
.7610F 7.93
.7090F 9.47
.7113F 8.78
LIMIT F 1.2250 F 12.00 F
99/05 .7491 4.94
LIMIT F 1.2250 F 30.00 F
99/06 .7064 5.64
LIMIT F 1.2250 F 12.00 F
99/07 .7591 5.33
99/08 .7588 4.13
LIMIT F 1.2250 F 12.00 F
99/09 .9574 5.81
99/10 1.0620
6.25
LIMIT F 1.2250 F 24.00 F
99/11 .7852 7.27
99/12
AVERAGE
MAXIMUM
MINIMUM
UNIT
.7007
.7747
2.1180
.1370
MGD
6.40
7.04
19.00
LESSTHAN
MG/L
8.4
8.6
8.4
30.0 F
5.4
30.0
6.4
30.0 F
4.9
2.5
30.0 F
3.8
8.9
30.0 F
9.4
6.5
7.0
45.0
LESSTHAN
MG/L
. 57
. 97
1.10
2.00
.35
NOL
.73
22.035
48.275
15.789
NOL
13.333
NOL
13.157
2.00 F 200.0 NOL
1.22 55.1 11.052
.74
3.7 18.333
2.00 F 200.0 NOL
1.45 6.0 17.368
2.07F
54.0 16.666
4.00 F 200.0
NOL
.94 75.7 16.666
1.60
1.04
6.12
LESSTHAN
MG/L
9.4 12.941
33.9 23.639
29000.0 210.000
LESSTHAN .000
#/100ML UG/L
5.27
5.61
5.40
NOL
5.28
NOL
5.04
NOL
5.03
5.00
NOL
5.20
5.58
NOL
5.72
6.59
NOL
1
NOL
1
5.47 1
7.70 1
5.00 1
MG/L PASS/FAI
GKEX88/MP•
COMPLIANCE EVALUATION ANALYSIS REPORT
04/28/2000
PAGE 2
PERMIT--NC0026671 PIPE--001 REPORT PERIOD: 9901-9912 LOC---E
FACILITY--ELIZABETHTOWN, TOWN - WWTP DESIGN FLOW-- 1.2250 CLASS--3
LOCATION--ELIZABETHTOWN REGION/COUNTY--06 BLADEN
00010 00400 00600 00665 01042 01077 71900
MONTH TEMP PH TOTAL N PHOS-TOT COPPER SILVER MERCURY
LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL
99/01 12.58 7.8-6.5 4.770 .7450 12.0000 .0000 .0000
99/02 15.89 7.7-6.5 9.240 2.4000 3.0000 1.5000 .0000
99/03 15.75 7.7-6.6 3.240 1.6200 10.3333 1.0000 .0000
99/04 19.77 8.0-7.0 11.330 2.9000 6.5000 .0000 .0000
LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL
99/05 21.80 7.8-6.9 10.120 2.4000 6.5000 .0000 .0000
LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL
99/06 24.27 7.9-7.2 4.450 3.4700 8.0000 .0000 .0000
LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL
99/07 25.76 7.7-7.1 11.850 4.0500 .0000 .0000 .0000
99/08 26.27 7.7-7.1 1.400 1.5200 .0000 .0000 .0000
LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL
99/09 24.04 7.7-7.1 6.040 1.6500 .0000 .0000 .0000
99/10 21.09 7.6-6.7 4.330 1.0600 .0000 .0000 .0000
LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL
99/11 19.30 7.5-6.7 3.850 3.0100 18.0000 .0000 .0000
99/12 16.52 7.8-6.5 1.880 .3400 6.5000 .0000 .0000
AVERAGE 20.25 6.041 2.0970 5.9027 .2083 .0000
MAXIMUM 28.00 8.000 11.850 4.0500 23.0000 3.0000
MINIMUM 9.00 6.500 1.400 .3400 6.0000
UNIT DEG.0 SU MG/L MG/L MG/L MG/L MG/L