Loading...
HomeMy WebLinkAboutSW6191001_Supplement-EZ Form_20201007SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION 1 I Project Name Yard Storage, Inc. 2 Project Area ac 2.21 3 Coastal Wetland Area ac 0 4 Surface Water Area ac 0 5 Is this project High or Low Density? High 6 Does this project use an off -site SCM? No (COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 15 feet 8 IVVill the vegetated setback remain vegetated? Yes 1 10 GIs stream bank stabilization proposed on this project? I No J NUMBER AND TYPE OF SCMs: 11 Infiltration System - - — 0 12 Bioretention Cell 0 _ 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 1 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Sp reader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 _ 21 Treatment Swale 0 22 Dry Pond 0 - - 23 StormFilter 0 24 Silva Cell 0 25 113a tier 0 26 IFilterra 0 N 28 Organization: 29 Street address: 30 City, State, Zip: 31 Phone number 32 Email; FORMS LOADED Lars O. Godwin Castle Keep 22 Long Ridge Cou 919-796-8561 Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. '`••'111111'�1r/ - �•�, CARol 41, ''• �4 QQOFtiSSI0�,9 l 't SEAL ? 9518 Signature of Designer A Date SAND FILTER III 1 l Drainage area number to treat the SW from all surfaces at 5 What are the side slopes of the 6UM (H:V)"? 3:1 Does the SCM have retaining walls, gabion walls or other engineered 6 side slopes? No Are the inlets, outlets, and receiving stream protected from erosion (10- 7 year storm)? Yes Is there an overflow or bypass for inflow volume in excess of the 8 design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes 11 Does the maintenance access comply with General MDC (8)? Yes 12 Does the drainage easement comply with General MDC (9)? Yes If the SCM is on a single family lot, does (will?) the plat comply with 13 General MDC (10)? Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an Plan that complies with General MDC (12)? Yes 16 Does the SCM follow the device specific MDC? Yes 17 Was the SCM designed by an licensed professional? Yes SHVV I elevation (tmsl) 369.U( Type of sand filter (open or closed) Open If closed, will the filter will be pre -cast or pour -in -place? 22 1 Is this sand tilter designed to attenuate peak flows? Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 2,200 cf 24 Will there be a permanent pool in the sediment chamber? No 25 Bottom of the sediment chamber (fmsl) 402.00 26 Area of the sediment chamber (square feet) 550 sf 27 Physical depth of the sediment chamber (inches) 60 in Ponding depth in the sediment chamber, above any permanent pool 28 (inches) 48 in 29 1 Elevation of top of weir between chambers (fmsl) 407.00 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 2,176 cf 33 Physical depth of the sand chamber (inches) 60 in Ponding depth in the sand chamber, above any permanent pool 34 (inches) 48 in 35 Elevation of the bypass device (fmsl) 406.00 Weir lined with..... 36 Type of bypass device riprap 37 Mechanism for distributing flow over the sand surface Gravel/stone layer ASTM C-33 sand 38 Sand specification for sand chamber or equivalent 39 Depth above underdrain pipe (inches) ______12 in Will the media be maintained to drain at least two inches per hour at 40 the sand surface? Yes Is at least one clean -out pipe provided at the low point of each 41 underdrain line? Yes 42 Will clean -out pipes be capped? -------Yes rmase use tnis space to proviae any aaanionai inrormanon a 43 Sand Filter(s): Sand Filter 4 4:00 PM 9/21/2020