Loading...
HomeMy WebLinkAbout20061042 Ver 3_More Info Letter_20120103REVENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Charles Waklld PE Governor Director Dee Freeman Secretary January 3 2012 DWQ Project # 06 1042 v 3 Durham County CERTIFIED MAIL 7008 1830 0004 8312 1354 RETURN RECEIPT REQUESTED K Scott Phillips Hearthstone Multi Asset Entity B LP 4509 Creedmoor Road Suite 200 Raleigh NC 27612 Subject Property Ashton Hall Subdivision — Phases 3 & 4 UT to Little Lick Creek [030401 27 9 (0 5) WS IV NSW] REQUEST FOR MORE INFORMATION Dear Mr Phillips On August 11 2011 the Division of Water Quality (DWQ) received your application dated August 9 2011 to fill or otherwise impact 0 21 acre of 404 wetland (permanent impacts) 104 linear feet of intermittent stream channel (permanent impacts) 7 014 square feet of Zone 1 Neuse River basin protected riparian buffer (permanent impacts) and 4 416 square feet of Zone 2 Neuse basin protected riparian buffer (permanent impacts) to complete the construction of the previously approved Ashton Hall Subdivision On October 21 2011 DWQ received insufficient additional information in response to a request for more information letter (dated September 23 2011) On December 8 2011 DWQ received insufficient additional information in response to a request for more information letter (dated November 22 2011) The DWQ has determined that your application and additional information was incomplete and/or provided inaccurate information as discussed below The DWQ will require additional information in order to process your application to impact protected streams and buffers on the subject property This project is on hold and incomplete until we receive the additional information requested below If we do not receive the requested information your project will be formally returned as incomplete Please provide the following information so that we may continue to review your project Additional Information Requested For LS VFS #7 the Supplement Form states that the peak flow during the design storm is 40 55 cfs while the peak flow from the 10 year storm is 29 45 cfs There appears to be an error Please provide the correct value for the peak flow from the design storm so that the DWQ can review your proposed level spreader design North Carolina Division Of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791 4200 Internet www ncwaterquality org 1628 Mail Service Center Raleigh NC 27699 1628 FAX (919) 788 7159 An Equal Opportunity /Affirmative Action Employer — 50 / Recycled /10 / Post Consumer Paper On No ehCarolind Customer Service 877 623 6748 Page 2 2 For BMP #8 please provide an explanation as to why a diffuse flow device has not been provided at the outlet For LS VFS #10 the Supplement Form states that the peak flow during the design storm is 58 15 cfs while the peak flow from the 10 year storm is 25 15 cfs There appears to be an error Please provide the correct value for the peak flow from the design storm so that the DWQ can review your proposed level spreader design 4 For LS VFS #11 the Supplement Form states that the peak flow during the design storm is 64 58 cfs while the peak flow from the 10 year storm is 42 27 cfs There appears to be an error Please provide the correct value for the peak flow from the design storm so that the DWQ can review your proposed level spreader design Please submit three copies of this information within 30 calendar days of the date of this letter Please send additional information to DWQ Central Office, Attn Karen Higgins, 1650 Mail Service Center, Raleigh, NC 27699 -1650 If we do not receive this requested information within 30 calendar days of the date of this letter your project will be withdrawn and you will need to reapply with a new application and a new fee If you need additional time to compile the information requested above please email Lauren Witherspoon (lauren witherspoon @ncdenr gov) requesting an extension and indicate a new date for submittal This letter only addresses the application review and does not authorize any impacts to wetlands waters or protected buffers Please be aware that any impacts requested within your application are not authorized (at this time) by the DWQ Please call Lauren Witherspoon at 919 791 4251 if you have any questions regarding this letter or would like to set up a meeting to discuss this matter i i Sincerel Danny Seegional Raleigh Office Supervisor Surface Water Protection Section cc DWQ Raleigh Regional Office File Copy WeBSCaPe — 1650 Mail Service Center Troy Beasley — Withers and Ravenel 1410 Commonwealth Drive Suite 101 Wilmington NC 28403 Filename 06 1042 v 3—Ashton Hall Subdivision Phases 3 & 4 401 NBR On Hold —3