HomeMy WebLinkAbout20210050 Ver 1_DWR Add'l Comment Responses_20210202SI RALEIGH: 1 Glenwood Avenue, Suite 600, Raleigh, NC 27603 E P OFFICE: 919.789.9977 / FAX: 919.789.9591 / WWW.SEPIINC.COM February 2, 2021 Mr. Rick Trone NCDEQ-Division of Water Resources, 401 Buffer and Permitting Branch 512 N. Salisbury Street, Suite 942-F Raleigh, NC 27604 Re: Northern High School Replacement Project (DWR #20210050v1) Responses to NCDWR Request for Additional Information Dear Mr. Trone, The following includes responses to the additional information request received from the N.C. Division of Water Resources on January 29, 2021: 1. Your application proposed proposes a total of 56,861 square feet of permanent buffer impacts for the projects. Please submit a modified buffer impact table that specifically lists each type of buffer impact (e.g. grading, road crossing, utility crossing, etc.) as outlined in 15A NCAC 02B.0714(10). The buffer impact table has been revised and is attached for review. 2. Please demonstrate why impacts to Riparian Buffer cannot be avoided or minimized by converting the SCM discharges to Dispersed Flow prior to entering the buffer. In addition, the Division has concerns that the perpendicular alignment of these discharges may destabilize the receiving stream banks. Please demonstrate why further minimization cannot be achieved by re -aligning these discharge points to an oblique angle to the receiving stream. Please address this for Impact Areas 1,2,3,4,7,8 and 9. [15A NCAC 02b .0714 (9), 15A NCAC 02B .06112(2) and 15A NCAC 02H .0506(b)]. The stormwater control measure discharges referenced are for high flow bypass only and are designed per the City of Durham Stormwater Requirements. The proposed stormwater management plan for the project has been reviewed and approved by the City of Durham Stormwater Department. 3. Please clarify the need for a 70-foot right-of-way for Site Drive 2/Hebron Road Extension. The Division believes that impacts to features SE and SD and associated riparian buffers can be further avoided by a reduction in width of Site Drive 2/Hebron Road Extension right-of-way. The Division understands the requirements imposed by NCDOT and DCHC-MPO regarding the need for ingress/egress points, safety and aligning the Hebron with the existing Wellington Drive as proposed and outlined in the Traffic Impact Analysis. However, it is unclear if the accommodation of the Hebron Road Extension right-of-way portion of the roadway is necessary to accommodate traffic for site access. Please clarify if Hebron Road Extension is 000000100010� 0J00 000000000000000 SEPI approved as part of a Transportation Improvement Plan (or similar) or is speculative based on an anticipated future traffic demands, considering that this roadway extension project is not part of the City -County of Durham Capital Improvement Plan and has not been scheduled or funded. In addition, please clarify if the proposed Hebron Road Extension is planned to connect to existing Hebron Road to the east [15A NCAC 02H .0506(b)(1)]. The Durham -Chapel Hill-Carrboro (DCHC) Metropolitan Planning Organization adopted Comprehensive Transportation Plan (CTP) shows Hebron Road extending from Denfield Street to Wellington Dive and is titled the Hebron Road Extension. This extension is classified as a minor thoroughfare. Since the Hebron Road Extension is classified as a minor thoroughfare, the City of Durham requires a 70 foot right-of-way with 3 travel lanes, bike lanes and sidewalks on both sides. (i.e. the width of the impact is determined by the Authority Having Jurisdiction-AHJ). The City requested that the DPS and the site plan reflect a 70 foot wide land reservation for future right-cf- way shall the Hebron Road extension ever be constructed. However, this extension is not currently on any jurisdictional Capital Improvement Plan (CIP) and is not scheduled or funded. All site improvements shown on the plan submitted are required by authorities having jurisdiction to support a private site driveway for a high-school use only. Improvements shown are NOT in support of anything having to do with the future Hebron Road extension. 4. Impact Area 1 (Site Drive 2/Hebron Road Extension) is proposed to impact stream feature SD through the addition of two culverts, fill and rip rap resulting in 187 linear feet of impact. Information provided in the application indicates the width of this crossing to be, at least in part, due to the addition of stacking lanes along the Hebron Road Extension resulting in a much wider road. Please demonstrate why it is infeasible to begin lane stacking after the crossing of stream feature SD. [15A NCAC o2H .0505(b)(1)]. In a letter from NCDOT, John Sandor, PE District Engineer to Joshua Reinke, PE, Ramey Kemp & Associates, Inc., Durham County Public Schools Traffic Engineer hired consultant dated June 17, 2020: (stating improvements required) US 501 at Wellington Drive/Site Drive 2 • Site Drive shall be constructed with one ingress lane and three egress lanes. The egress lanes shall consist of one exclusive left -turn lane with 150 feet of storage, a shared left -through lane, and an exclusive right -turn lane with 250 feet of storage. The egress shall also contain 100 feet of Internal Protected Storage (IPS) before any parking or crossing maneuvers. 000000000000000 000000000000000 SEPI 5. Please provide a detailed engineering plan, profile view, and cross-section of the proposed culvert for Stream SE. These drawings must include details regarding stream alignment in relation to pipe alinement, pipe slope, pipe burial, and dissipator pad [15 NCAC 02H. 0502(a)(9)]. Detailed engineering plan & profile views are found on Sheets C-7 and C-8 Culvert Profile. See attached impact maps. 6. Please explain how the width of the road crossing at Impact Area 5 has been minimized to the maximum extent practicable. [15 NCAC 02H .0506(b)(1)] Retaining walls are proposed to reduce the overall slope impacts and minimize long-term bank erosion. A thirty-foot wide drive is provided to support emergency, service and pedestrian vehicles. An 8-foot wide walk is provided on the north side for safe pedestrian travel to and from the student parking lot which is used after- hours for event parking to the stadium. Utilities to support the new school and auxiliary structures run parallel to the drive on the south side. 7. The angle of stream SD as it enters the proposed culvert at Impact Area 5 is likely to result in accelerated erosion and underscoring to the area on the outside of this bend as it enters the culvert. Please describe how potential problems such as erosion and underscoring will be prevented in this area and if an alternate crossing location has been explored [15 NCAC 02H .0506(b)(1)]. Per NCDOT, the Argonne Drive entrance must include the installation of channelized south bo und/north bound left turn lanes on US 501. The drive will be constructed as a limited movement intersection with one ingress and one egress lane. Furthermore, Argonne Drive will be restricted to a right -turn lane only. The location of this entrance is mandated based on requirements from the DPS in conjunction with the State Board of Education -NC Department of Public Instruction, the City -County of Durham and the N.C. Department of Transportation. The guidelines require at least two entrances to the school be accessed from a public road, that entrances be at least 600 feet apart to comply with public safety standards, and that the entrance be aligned with Argone Drive. Other culvert alignments were explored and were determined to result in larger stream impact amounts. An alignment that betters the flow entrance would lengthen the culvert and would generate an outlet angle that may not be preferred. Another option may be to place a bend in the middle of the culvert to maximize the inflow and outflow alignment, but would lengthen the impact and raise questions on how to model. 000000000000000 000000000000000 SEPI 8. Please clarify that stream impacts were calculated based on stream length, not culvert length and update impact table if necessary. [15 NCAC 02H. 0502 (a) and (c)]. Stream impacts were calculated based on stream length per [15 NCAC 02H. 0502 (a) and (c)]. 9. Mitigation is required for losses of equal to or greater than 300 linear feet of perennial stream. Please provide a mitigation plan that confirms to the requirements of 15A NCAC 02H .0506. Furthermore, buffer mitigation is required for some of the prosed buffer impacts. Please submit a mitigation plan in compliance with 15A NCAC 02B .0295 [15A NCAC 02H 0506 and 15A NCAC 02b. 0714(12)] A final mitigation plan will be provided once impacts amounts are approved and quantified by both agencies. 10. If the U.S. Army Corps of Engineers request a response to any of the comments received as a result of the Public Notice, please provide the Division with a copy of your response to the USACE {15 NCAC 02H .0502( c)]. If a response is requested, a copy will be provided to both DWR and USACE. ` 000000000000000 000000000000000 Permanent Buffer Buffer (P) / Mitigation Zone 1 Zone 2 Impact Impact Temporary Stream Required impact impact Sheet No. Area No. (T) Reason for Impact Type of Impact Name (Y/N) (sq. ft.) (sq.ft.) Road Crossing, Non- Allowable with C3 1 P Perpendicular Mitigation SE Y 14,928 7,119 Road Crossing- C3 1 P Perpendicular Allowable SD N 2,619 492 Road Crossing- Allowable Upon C3 1 P Perpendicular Authorization SD N 5,575 0 Road Crossing- C3 1 P Perpendicular Allowable SD N 0 3,193 Stormwater Control Allowable with C4 2 P Measure Mitigation SD Y 936 0 Stormwater Control C4 2 P Measure Allowable SD N 0 698 Stormwater Control Allowable with C4 3 P Measure Mitigation SD Y 906 0 Stormwater Control C4 3 P Measure Allowable SD N 0 631 Stormwater Control Allowable with C4 4 P Measure Mltigation SD Y 853 0 Stormwater Control C4 4 P Measure Allowable SD N 0 609 Road Crossing- 05 5 P Perpendicular Allowable SD N 847 672 Road Crossing- 05 5 P Perpendicular Allowable SD N 3,778 2,408 Road Crossing- 05 5 P Perpendicular Allowable SD N 3,014 1,738 Utility-Sewer- C6 6 P Replacement Allowable SD N 282 742 Stormwater Control Allowable with C6 7 P Measure Mitigation SD Y 943 0 Stormwater Control C6 7 P Measure Allowable SD N 0 655 Stormwater Control Allowable with C6 8 P Measure Mitigation SD Y 1,024 0 Stormwater Control C6 8 P Measure Allowable SD N 0 670 Stormwater Control Allowable with C6 9 P Measure Mitigation SA Y 914 0 Stormwater Control C6 9 P Measure Allowable SA N 0 615 TOTAL BUFFER IMPACTS 36,619�20, 242 IMPACT AREA #8 (see sheet C-6) %//�C� r IMPACT AREA #9 y1 a (see sheet C-6) APPLICANT INFORMATION: OMM Dulls"0WACE' RRMW HALL 2MI HAWK MW (M)-W0--2W4 119NAWHAIL.OPSNGMir IN IMPACT AREA #7 III�IIII Illl (Ill IIIII►1 I/I)I IIII I/ I/ , / (see sheet C— 3) '" s ������\\\\\\�\�\\\ \ I I I IIIIIIIjI////�/// //// Ijll�llll / I /Ill 1 Illl/// //!lll�lll I /// \\ �� r�///��I f r ;� ��\\��\\�\\��IIIIII I I /// / /�////////// I'%///f///�/ �i / — ( I I / // % '�/ ' \\ / I 1 I I a I I I I 1 I l \ \� \� ��\ \\\\\\\\111 �I�1i/ /�i�%%�//�/////�////�/ �/ / //'1 (1 � / 11 1 � // /�� \ l I I \ .\ Ij I �III1�1\I IMPACT AREA #5 \\ \ \ (see sheet C-5) IMPACT AREA #4 (see sheet C-4) IMPACT AREA #2 \)�llll (see sheet C-4) 11/i)�I I �111111 1,11 , It / 11 �j// //�//(I / /// ^\ \\ \� \ III ( \ \ . \ ..•��, .• •. —L IMPACT AREA #6 //�� ���\II► %%XX/v (see sheet C-6) Ai \ ,/ ,,//// //j // iii%/// � 1 III /ii jl -- \ \� � \ \ \\ � — \ •`�°••` /I f / IMPACT AREA #3 / (see sheet C-4) 111 /ll // �/ / / I� \�\ \ � � \ 1` ��"�J,--� � \ \� \ \ \ .::ti:•.: // /� / .••�;�:,: I r/ (I I a9snNc 36' CMP CULVERT 19 LE it 11\\�� \\ 1:j! . i / o9snNc ooueLE sa' RCP cuu�Rr 12 LF +��'�Ty.�..:•... IMPACT AREA #1 \ it (see sheet C-3) ►��\I \ I / / j \\—� i // !� ��� //'�✓/i f GRAPHIC SCALE vm a roo rm a w ( IN 7nT 1 inch — ON 1L Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 Owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I Electrical/Plumbing Engineer PDC Engineers 3101 Poplarwood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and Envelope Design Rick Nuhn Engineering 1913 Thayer Circle Greensboro, NC 27407 336-855-1182 Food Design FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 SEAL I DATE 10/05/2020 PRELIMINARY - NOT FOR CONSTRUCTION PROJECTNO. 02000.000 SHEET TITLE C-1 OVERALL EXISTING CONDITIONS PLAN SHEETNUMBER ,r�,► 51 REA 8IMPACT AREA 9 fit; {► �� �S_ „•„ � I,i � j (see sheet / i '✓'� j • '� fit: �.. (see sheet C-6) OAN IMPACT AREA #7 "MIN 111I 11 I�A�� \ 1C`�• � ,�'1 y���i� I I'.•//A'//lA�� _ I ALLOWABLE 943 SQFTI L I■� niirriQ�NVI • I IKL �3 I _e sheet C MA I(s ra 1�F J� if Sys_ ►�_�s�;= F�rft C I �y - ` ZONE I- ALLOWABLE - 3,778 SQF ZONE 1- ALLOWABLE - jG wi w1U 11 � rl-zw 44 lot V0.111 Ll SOFT .�Vi/1I�/P_iG��.i�r��! •li��li 1 v,��t>Sif/i�fLN �L `Qll�if/I •�(��_�_!/ a J _ r'�► (see sheet •Off li - - ram. 1�1 ,:.►.,.. u_ ,,, �..:• �Iy■!-� ��J"' •� / ,t I � ,�IIII���' --'� i1' '.' 1 ,�6;..,c�/-! ?r.�•,I� 1�s�, I I I A � �lu►v�z,�oikinr�n�a_v_��sv�uJ ���I _.� 1 ��r��!� �'�� �i� ���=�►��, ZONE 2- ALLOWABLE - 609 Egli -- -- I • 1 I , A I Elm�_rt.�.... r ■ r rI - ■ •11 • • I A �\ �� i // Yli'11i"` ®mow Fly I ALLOWABLE SQFT � iiNHN. F'J Arm y��g:��, ,� � �� ' ir■ II II111sy'? I �jV I IMPACT I RI . ZONE 2- ALLOWABLE - 492 SOFT \ ,n y / see sheet C-3 E PROPOSED 4'HX7'W SECONDARY I ± ` •:.�' / / --�-� i / PRECAST CONCRETE CULVERT 136 LF \�� l\h J TOTAL NETLANDS ON -SIX. 2.49 ACRES ` TOTAL NETLANDS IMPACTED ON -SITE: 0.00 ACRES PROPOSED 7'HX7'W PRIMARY PRECAST TOTAL LINEAR FEET OF STREAM ON -SITE• 3,633 LF CONCRETE CULVERT 136 LF TOTAL LINEAR FEET OF STREAM IMPACTED ON -SITE: 647 LF 1 TOTAL SQUARE FEET OF STREAM IMPACTED ON-SITE7,550 SF TOTAL ZONE 1 ON -SITE: 19,202 SF ZONE - 2,619 SOFT TOTAL ZONE 2 ON-SITE:35,476 SF IMPERVIOUS AREA FOR PROPOSED PRO,.IECT.� 19.92 ACRES • .1-ALLOWABLE GRAPHIC SCALE IN o IN THIS PROPERTY IS LOCATED ZONE %" AREAS DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOOD PLAIN AS SHOW ON FIRM PANELS 0824 & 0834, MAP NUMBERS 37200824OW AND 3720083400K WITH AN EFFECTIVE DATE OF OCTOBER to FMT 19, 2018. t imh - 150 tL Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919 560 2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I Electrical/Plumbing Engineer PDC Engineers 3101 Poplarvood Court, Suite 320 Raleigh, NC 27604 919790 s989 Civil Engineer 8 Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and Envelope Design Rick Nuhn Engineering 1913 Thayer Circle Greensboro, NC 27407 336-855-1182 Food Design FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 91954s 0288 SEAL I DATE 12/09/2020 PRELIMINARY - NOT FOR CONSTRUCTION RAT 10 PROJECTNO. 02000.000 SHEET TITLE C-2 OVERALL PROPOSED CONDITIONS PLAN SHEETNUMBER I cl I I I I o I I/ PERMANENT OUTLET PROTECTION I I I I PRIMARY CULVERT CLASS B STONIVi RIP RAP TO BE BURIED AT GRADE 1 I l ZONE 2- ALLOWABLE WITH ZONE 1- ALLOWABLE WITH I j i / MITIGATION - 7,119 SQFT MITIGATION - 14,928 SOFT LIMITS OF DISTURBAN I /. PERMANENT STREAM IMPACT 309 LF ZONE 2- ALLOWABLE - 492 SOFT IMPACT TABLE J PERMANENT OUTLET PROTECTION /J SECONDARY CULVERT 26148'W146'W2x22•TFI l l l I ✓ l CLASS STONE RAP 1D E RI BURIED AT GRADE co / Cli / ZONE 1- ALLOWABLE UPON I I AUTHORIZATION - 5,575 SQFT / 1 ZONE 2- ALLOWABLE - 3,193 SOFT 1 i i CULVERT 11 � 7H' X 7W PRECAST CONCRETE BOX CULVERT 136' LF '/, L'l� 4H' X 7W' PRECAST CONCRETE BOX CULVERT 136' LF / PERMANENT STREAM ` 7-1 V° / I IMPACT-187' LF ZONE 1- ALLOWABLE - 2,619 SQFT TEMPORARY IMPACT, 8 OFFER I LF I STREAM CENTERLINE I I I I I I I I I I \ I LIMITS OF DISTURBANCE I I I TOP OF STREAM BANKi I i 11 I I I I I I I IMPACT AREA #1 Impact Location Impact Feature Impact Type Impact Purpose Impact Amount Permanent Loss Impact Amount Project Impact (sq ft) Project Impact (acres) Impact Areal Stream Existing Culvert 31 LF 0LF 0 0 Impact Area 1 Stream Permanent Culvert 187 LF 187 LF 1,109 0.025 Impact Area 1 Stream Permanent Fill 309 LF 309 LF 3,036 0.069 Impact Area 1 Stream Permanent Rip Rap 32 LF 0 527 0.012 Impact Areal I Stream I Temporary 1 Coffer Dam 1 8LF 1 0 1 0 1 0 Totals: 1 536 LF 1 496 LF 1 4,672 SF 1 0.11 AC IMPACT LEGEND TYPE IMPACT DELINEATION WETLAND WWWWWWWW W W W W W W COFFER DAM RIP RAP FILL PROPOSED CULVERT EXISTING CULVERT ZONE 1 ALLOWABLE ZONE 2 ALLOWABLE ZONE 1 ALLOWABLE UPON AUTHORIZATION ZONE 1 ALLOWABLE K17H M177GA77ON UPON AUTHORIZATION ' ZONE 2 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION STREAM IMPACT 17 V V 17 NEUSE RIVER BUFFER AND STREAM IMPACTS - AREA 1 BUFFER IMPACTS ZONE 1 ZONE 2 CROOKED CREEK SQ FT SQ FT ALLOWABLE 2,619 3,685 ALLOWABLE UPON AUTHORIZATION 5,575 0 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION 14,928 7,119 TOTAL 23,122 10,804 GRAPHIC SCALE 20 40 80 it:107 Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821_0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I Electri--/Plumbing Engineer PDC Engineers 3101 Poplarwood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and Envelope Desion Rick Nuhn Engineering 1913 Thayer Circle Greensboro, NC 27407 336-855-1182 Food Desion FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 PRELIMINARY - NOT FOR CONSTRUCTION aSs noE PROJECTNO. 02000.000 SHEET TITLE C-3 DETAIL PROPOSED CONDITIONS PLAN ( IN FEET ) 1 inch = 40 ft. I SHEETNUMBER / RIP RAP OUTLET PROTECTION = 22 LF RIP RAP TO BE BURIED AT GRADE / \ ZONE 2- ALLOWABLE 698 SQFT ZONE 1- ALLOWABLE WITH MITIGATION - 936 SQFT I IMPACT AREA #2 IMPACT TABLE RIP RAP OUTLET PROTECTION - 21 LF \ \ / RIP RAP TO BE BURIED AT GRADE / \ =// ZONE 2- ALLOWABLE 631 SOFT ZOOWA MTIGATION L - 906 SOFT IMPACT AREA #3 NEUSE RIVER BUFFER AND STREAM IMPACTS - AREA 2,3 & 4 BUFFER IMPACTS ZONE 1 ZONE 2 CROOKED CREEK SQ FT SQ FT ALLOWABLE 0 1,938 ALLOWABLE UPON AUTHORIZATION 0 0 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION 2,695 0 TOTAL 2,695 1,938 40 RIP RAP OUTLET PROTECTION = 21 LF / RIP RAP TO BE BURIED AT GRADE 7 C ZONE 2 - ALLOWABLE - 609 ZONE 1- ALLOWABLE WITH �\ MITIGATION - 853 SOFT 1 IMPACT AREA #4 IMPACT LEGEND TYPE IMPACT DELINEATION WETLAND W W W W y W W W W W W W COFFER DAM RIP RAP FILL vim PROPOSED CULVERT EXISTING CULVERT ZONE 1- ALLOWABLE WITH MITIGATION ZONE 2-ALLOWABLE GRAPHIC SCALE 0 20 40 80 ( IN FEET ) 1 inch = 40 ft. 160 Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 Owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I Electrical/Plumbing Engineer PDC Engineers 3101 Poplarwood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, INC 27518 919-319-6716 Roof and Envelope Design Rick Nunn Engineering 1913 Thayer Circle Greensboro, INC 27407 336-855-1182 Food Desiqn FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 SEAL I DATE 12/09/2020 PRELIMINARY - NOT FOR CONSTRUCTION bR r'_ PROJECTNO. 02000.000 SHEET TITLE C-4 DETAIL PROPOSED CONDITIONS PLAN I SHEETNUMBER 5 / /111111 11 WIN / 4ZONE 1- ALLOWABLE - 847 SOFT ZONE 2- ALLOWABLE - 672 SQFT LIMITS OF DISTURBANCE SS / RETAINING WALL 8 , PERMANENT OUTLET PR07EC71ON STW•TNLASON RIP RAP TO BE BURIED AT GRADE ZONE 1- ALLOWABLE - 3,014 SQFT /r ZONE 2- ALLOWABLE - 1,736 SOFT Z.Wi— 1" ' ' /`�)/ PERMANENT STREAM IMPACT 67 LF / , 8.5 HX8'W PRECAST CONCRETE BOX CULVERT 63 LF / I LIMITS OF DISTUR ANCE If ZONE 1- ALLOWABLE = 3,778 SOFT Ui / TEMPORARY ZONE 2- ALLOWABLE 2,408 SQFT ' / IMPACT, COFFER / / DAM = 8 LF STREAM / TOP OF STREAM BANK IMPACT AREA #5 IMPACT TABLE Impact Location Impact Feature Impact Type Impact Purpose Impact Amount Permanent Loss Impact Amount Project Impact (sq ft) Project Impact (acres) Impact Area 5 Stream Permanent Culvert 67 LF 67 LF 1,501 0.035 Impact Area 5 Stream Permanent Rip Rap 36 LF 0 936 0.021 Impact Area 5 Stream Temporary Coffer Dam 8 LF 0 0 0 Totals: 111 LF 67 LF 2,437 SF 0.056 AC / I/ / / / / IMPACT LEGEND TYPE IMPACT DELINEATION WETLAND yWWWWWWWWW W W W W N W W W W COFFER DAM RIP RAP FILL PROPOSED CULVERT EXISTING CULVERT ZONE 1 ALLOWABLE ZONE 2 ALLOWABLE ZONE 1 ALLOWABLE UPON AUTHORIZATION ZONE 1 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION ' ZONE 2 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION STREAM IMPACT 0 0 17 0 NEUSE RIVER BUFFER AND STREAM IMPACTS - AREA 5 BUFFER IMPACTS ZONE 1 ZONE 2 CROOKED CREEK SQ FT SQ FT ALLOWABLE 7,639 4,818 ALLOWABLE UPON AUTHORIZATION 0 0 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION 0 0 TOTAL 7,639 4,818 GRAPHIC SCALE 40 O 20 40 80 160 Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 ner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical L Electrical/Plumbing Engineer PDC Engineers 3101 Poplari Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Landsca�Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and EnveloneRoof and Envelope Desion Rick Nuhn Engineering 1913 Thayer Circle Greensboro, NC 27407 336-855-1182 Food Desiqn FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 SEAL I DATE 12/09/2020 PRELIMINARY - NOT FOR CONSTRUCTION SHEET ISSUE 2 ]RATin PROJECTNO. 02000.000 SHEET TITLE C-5 DETAIL PROPOSED CONDITIONS PLAN ( IN FEET ) 1 inch = 40 ft. SHEET NUMBER ZONE 2- ALLOWABLE - 742 SQFT / ZONE 1- ALLOWABLE - 282 SOFT IMPACT AREA #6 RIP RAP OUTLET PR07EC71ON = 21 LF / /PIN"24 / RIP RAP TO BE BURIED AT GRADE IZONE 2- ALLOWABLE - 670 SOFT I ZONE 1- ALLOWABLE WITH MITIGATION - 1024 SOFT IMPACT AREA #8 IMPACT TABLE 2 I RIP RAP OUTLET PR07EC71ON = 21 LF I // RIP RAP TO BE BURIED AT GRADEPROM II 1 I � I I ' PAR NENT I I%J SS II it ZONE 1- ALLOWABLE WI7H �6, / M171GA710N - 943 SQFT �� \ ZONE 2- ALLOWABLE - 655 SOFT IMPACT AREA #7 l \ � RIP RAP OUTLET PR07EC71ON = 21 LF RIP RAP TO BE BURIED AT GRADE lZONE 1-ALLOWABLE WITH M171GA71ON - 914 SQFT ZONE 2- ALLOWABLE - 615 SQFT IIV 41 1\ I 1 c IL IV 4,� WETLAND IMPACT AREA #9 NEUSE RIVER BUFFER AND STREAM IMPACTS - AREA 6,7,8 & 9 BUFFER IMPACTS ZONE 1 ZONE 2 CROOKED CREEK SQ FT SQ FT ALLOWABLE 282 2,682 ALLOWABLE UPON AUTHORIZATION 0 0 ALLOWABLE WITH MITIGATION UPON AUTHORIZATION 2,881 0 TOTAL 3,163 2,682 40 0 IMPACT LEGEND TYPE DE LINEATION WETLAND W W W W WWWWWWWW� W W W COFFER DAM RIP RAP FILL PROPOSED CULVERT EXISTING CULVERT — — — — ZONE 1 ALLOWABLE. ZONE 2 ALLOWABLE GRAPHIC SCALE 20 40 SO Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 Owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I ElectricallPlumb Engineer PDC Engineers 3101 Poplarwood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and Envelope Design Rick Nuhn Engineering 1913 Thayer Circle Greensboro, NC 27407 336-855-1182 Food Design FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 SEAL I DATE 12/09/2020 PRELIMINARY - NOT FOR CONSTRUCTION NN' RATIO I PROJECTNO. 02000.000 SHEET TITLE C-6 DETAIL PROPOSED CONDITIONS PLAN ( IN FEET ) 1 inch = 40 ft. SHEETNUMBER IMPACT AREA #1 35 FG ELEV. 349.00 35GRADE 34 TEMPORARY COFFER )DAM 34 EXISTING 33 INVERT IN. 32 00' 136 LF 1.5HX7.5'W PRIMARY PRECAST CONCRETE BOX CULVERT @ 2.21% SLOPE 32 INVER 10+00 11 +00 M.3 COFFER DAM I I I I I I I STREAM CENTERLINE % j l i 80 -N TOP OF STREAM BANK / CUL VCR T 1 PLAN 350 345 HEAD 340 WALL 335 OUTLET PROTECTION SHALL BE INSTALLED SUCH THAT RIPRAP IS FLUSH WITH EXISTING GRADE. SEE DETAIL. CLASS B RIPRAP DISSIPATOR 32'Lx24'W1X21W2x22"TH OUTJ 329.00' 325 12+00 13+00 z GRAPHIC SCALE 0 40 80 160 320 35 35 FG ELEV: 349.00' FINISH 34 34 33 EXISTING GRADE 33 INVERT IN:3 5.50 136 LF 4'HX5'W SECONDARY PRECAST BOX CULVERT @ 1.10% SLOPE 32 10+00 11 +00 CULVERT 1 PROFILE ( IN FEET ) 1 inch = 80 ft. HORIZONTAL: 1"=80' VERTICAL: 1"= 8' OUT.334.0 ' 350 345 340 335 HEAD HALL 'VERT OUTLET PROTECTION SHALL BE INSTALLED SUCH THAT RIPRAP IS FLUSH WITH EXISTING GRADE. SEE DETAIL. CLASS B RIPRAP DISSIPATOR 26'Lx 18W 1 'X 16 W2X22"TH 325 13+00 12+00 Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 Owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I Electrical/Plumbing Engineer PDC Engineers 3101 Poplarwood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and Envelope Design Rick Nuhn Engineering 1913 ThayerCircle Greensboro, NC 27407 336-855-1182 Food Design FooDesign Associates 615 Sou[h Coll ege Street, 9th Floor 919-546-0288 PRELIMINARY - NOT FOR CONSTRUCTION SHEETISSUE IINWRN. ATIO PROJECTNO. 02000.000 SHEET TITLE C-7 CULVERT PROFILE SHEETNUMBER IMPACT AREA #2 35F 3� 34 34 3� 3� 3z' 32 CULVERT 2 PLAN FG ELEV.- 350.00' FINISH GRADE 350 RETAI ING WALL 345 63 LF 8.5'HX8'W PRECAST CONCRETE BOX CULVERT @ 294% SLOPE 340 TEMPORI RY COFFER AM XL 335 330 OUTLET PROTECTION SHALL BE INSTALLED SUCH THAT RIPRAP IS FLUSH WITH EXISTING GRADE. SEE DETAIL. CLASS B RIPRAP DISSIPATOR 36'Lx24'WIX28W2x22"TH EXISTING GRADE INVERT IN: 24.80 INVERT OUL 324.40' z ,)n 10+00 11 +00 12+00 12+50 CULVERT 2 PROCILE i , , /""" X 80 0 Z11 GRAPHIC SCALE 40 80 160 ( IN FEET ) 1 inch = 80 ft. HORIZONTAL: 1"=80' VERTICAL: 1"-8' 320 Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 Owner _ Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical / Electrical/Plumbing Engineer PDC Engineers 3101 Poplanvood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 Roof and Envelope Design Rick Nuhn Engineering 1913 Thayer Circle Greensboro, NC 27407 336-855-1182 Food Design FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 SEAL I DATE 12/09/2020 PRELIMINARY NOT FOR CONSTRUCTION SHEETISSUE *RATIO PROJECT NO. 02000.000 SHEET TITLE C-8 CULVERT PROFILE SHEETNUMBER L TYPE STONE A A 00 00 000000 0° oo�o ° 0°0 o 0 0 00 0 0° o 0 ° 0 0° o o O O O o o O o - o op 0 D O O o O O O OOOOOo00000Oo°0�'. °0 Oo 00 o O O O 0 000 00 00000�000� �C) OOOOO � 0 0 0 oO0 C 0 0 000 O° o°po0 o Uo0 00 0 0 0 0 VOOOOo0000O0o 00 °00 0 0 o O° 00°0o0°° PLAN (OUTLET TO FLAT AREA WITH NO WELL DEFINED CHANNEL) L o O Oo B O J �1 -'z 000°0000 Op O O O �0 0 Oo000 o O O o O o0 °p O o o �bo ° o po zz� o o COo°o0°Oo °O o0° °o = U 0 0 O °0 °0OOo O�� �O 0 0 °00 Oop 0o0 0 O� O °°Op ° C) o° 0 0 0 0 00 O O p O o 0 0 0 0 00 00 0 000 ooDo p000 PLAN (OUTLET TO WELL DEFINED CHANNEL) MAINTENANCE NOTES: 1. RIP RAP OUTLET STRUCTURES TO BE INSPECTED WEEKLY AND AFTER EVERY RAINFALL EVENT 2. REPAIR DISLODGED STONES TO DESIGN DIMENSIONS IMMEDIATELY 3. IF MORE SUBSTANTIAL DAMAGE OCCURS, NOTIFY ENGINEER TO DETERMINE A REPAIR SOLUTION. N 0 TES: SECTION AA 00000V00 °o°O°O o Uo 00000�00 0 0 �0000v00< SECTION B-B (AMOCO 2006 OR EQUIVALENT) FILTER BLANKET TYPE STONE f— FILTER BLANKET (AMOCO 2006 OR EQUIVALENT) 1. TOP OF RIP RAP AT DOWNSTREAM END OF APRON SHALL BE FLUSH WITH NATURAL GRADE OF THE RECEIVING CHANNEL. 2. INSTALL OUTLET PROTECTION IMMEDIATELY AFTER INSTALLATION OF PIPE, 3. SEE GRADING PLAN FOR PERMANENT OUTLET PROTECTION DIMENSIONS. SEE EROSION CONTROL PLAN FOR TEMPORARY OUTLET PROTECTION DIMENSIONS. RIPRAP OUTLET PROTECTION DETAIL N. T S. -1111110- 0 1 O O O 1 O Ot o SAND BAGS 00000 O 00000 8' TEMPORARY COFFER DAM OETAIL Northern High School Replacement 4622 & 4804 N. Roxboro Street Durham, NC 27704 Owner Durham Public Schools 2011 Hamlin Road Durham, NC 27704 919-560-2000 Architect RATIO 227 Fayetteville Street, Suite 301 Raleigh, North Carolina 27601 919-821-0805 Structural Engineer LHC Structural Engineers 5430 Wade Park Blvd, Suite 400 Raleigh, NC 27607 919-832-5587 Mechanical I ElectricallPlumbing Engineer PDC Engineers 3101 Poplamood Court, Suite 320 Raleigh, NC 27604 919-790-9989 Civil Engineer & Landscape Architect CLH Design, PA 400 Regency Forest Drive, Suite 120 Cary, NC 27518 919-319-6716 pppn RLic u Engineering 13 ha rcircle re sb • NC 27407 336-855-1182 Food Design FooDesign Associates 615 South College Street, 9th Floor Charlotte, NC 28202 704-545-6151 Theatre Consultant Theatre Consultants Collaborative 519 Polk Street Raleigh, NC 27604 919-546-0288 PRELIMINARY - NOT FOR CONSTRUCTION QG RAT I O PROJECTNO. 02000.002 SHEET TITLE C-9 DETAILS SHEETNUMBER