CONSTRUCTION SPECIFICATIONS:
CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS AND OTHER
OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT.
PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE
PLANS AND SMOOTH IT.
PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE
OUTLET.
USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF THE FOUNDATION
IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE.
MAINTENANCE:
MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM
LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH
2" STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT
AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE
MATERIALS SPILLED, WASHED OR TRACKED ONTO PUBLIC ROADWAYS.
PIPE OUTLET
as
NOT TO SCALE
!fLlf
��00 F_.lF—SAP VARIES
PIPE OUTLET
C12" FILTER FABRIC TO
BE INSTALLED UNDER
ALL RIP —RAP
CONSTRUCTION SPECIFICATIONS
2"-3" COURSE AGGREGATE
® 6" DEEP MINIMUM WITH
FILTER FABRIC UNDERLINER
1. ENSURE THAT THE SUBGRADE FOR THE FILTER AND RIPRAP FOLLOWS THE REQUIRED LINES AND GRADES SHOWN IN
THE PLAN. COMPACT ANY FILL REQUIRED IN THE SUBGRADE TO THE DENSITY OF THE SURROUNDING UNDISTURBED
MATERIAL. LOW AREAS IN THE SUBGRADE ON UNDISTURBED SOIL MAY ALSO BE FILLED BY INCREASING THE RIPRAP
THICKNESS.
2. THE RIPRAP AND GRAVEL FILTER MUST CONFORM TO THE SPECIFIED GRADING LIMITS SHOWN ON THE PLANS.
3. FILTER CLOTH, WHEN USED, MUST MEET DESIGN REQUIREMENTS AND BE PROPERLY PROTECTED FROM PUNCHING OR
TEARING DURING INSTALLATION. REPAIR ANY DAMAGE BY REMOVING THE RIPRAP AND PLACING ANOTHER PIECE OF FILTER
CLOTH OVER THE DAMAGED AREA. ALL CONNECTING JOINTS SHOULD OVERLAP SO THE TOP LAYER IS ABOVE THE
DOWNSTREAM LAYER A MINIMUM OF 1 FOOT. IF THE DAMAGE IS EXTENSIVE, REPLACE THE ENTIRE FILTER CLOTH.
4. RIPRAP MAY BE PLACED BY EQUIPMENT, BUT TAKE CARE TO AVOID DAMAGING THE FILTER.
5. THE MINIMUM THICKNESS OF THE RIPRAP SHOULD BE 1.5 TIMES THE MAXIMUM STONE DIAMETER.
6. RIPRAP MAY BE FIELD STONE OR ROUGH QUARRY STONE. IT SHOULD BE HARD, ANGULAR, HIGHLY
WEATHER —RESISTANT AND WELL GRADED.
7. CONSTRUCT THE APRON ON ZERO GRADE WITH NO OVERFILL AT THE END. MAKE THE TOP OF THE RIPRAP AT THE
DOWNSTREAM END LEVEL WITH THE RECEIVING AREA OR SLIGHTLY BELOW IT.
8. ENSURE THAT THE APRON IS PROPERLY ALIGNED WITH THE RECEIVING STREAM AND PREFERABLY STRAIGHT
THROUGHOUT ITS LENGTH. IF A CURVE IS NEEDED TO FIT SITE CONDITIONS, PLACE IT IN THE UPPER SECTION OF THE
APRON.
9. IMMEDIATELY AFTER CONSTRUCTION, STABILIZE ALL DISTURBED AREAS WITH VEGETATION (PRACTICES 6.10, TEMPORARY
SEEDING, AND 6.11, PERMANENT SEEDING).
MAINTENANCE
INSPECT RIPRAP OUTLET STRUCTURES WEEKLY AND AFTER SIGNIFICANT (1 /2 INCH OR GREATER) RAINFALL
EVENTS TO SEE IF ANY EROSION AROUND OR BELOW THE RIPRAP HAS TAKEN PLACE, OR IF STONES HAVE
BEEN DISLODGED. IMMEDIATELY MAKE ALL NEEDED REPAIRS TO PREVENT FURTHER DAMAGE.
O UTLET STAB I LI ZATI O N STR U CTU R E
NOT TO SCALE
2' MIN.
nr%unnnTrn r+.-%n
NOTES:
BUILD RIDGE HIGHER THAN DESIGN AND COMPACT WITH WHEELS OF CONSTRUCTION EQUIPMENT. COMPACTED RIDGE
MUST BE AT OR ABOVE DESIGN GRADE AT ALL TIMES.
LEAVE SUFFICIENT AREA ALONG DIVERSION TO PERMIT CLEANOUT AND REGRADING.
CONSTRUCTION SPECIFICATION
1.REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE MATERIAL.
2.ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. DIKE IS NOT LOWER AT ANY POINT THAN
THE DESIGN ELEVATION
3.ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENT.
4.PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE REGRADING AND CLEANOUT.
5.VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS.
MAINTENANCE
INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. IMMEDIATELY REMOVE SEDIMENT
FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS
AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO
BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT.
TEMPORARY DIVERSION DITCH
NOT TO SCALE
WIRE FENCING AND
WOVEN GEOSYNTHETIC
FILTER FABRIC
EXTEND FABRIC AND
WIRE INTO TRENCH -
COMPACTED
BACKFILL --
NOTE:
REMOVE SEDIMENT DEEPER T
12". REPAIR ANY UNDERMINE
IMMEDIATELY.
MAINTENANCE
STEEL POSTS
8' O.C. W/WIRE
INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL.
MAKE ANY REQUIRED REPAIRS IMMEDIATELY.
SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR
BECOME INEFFECTIVE, REPLACE IT PROMPTLY.
REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE
VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE 0 THE FENCE. TAKE
CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT.
REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING
THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE
AREA HAS BEEN PROPERLY STABILIZED.
CONSTRUCTION SPECIFICATIONS:
CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA
STRENGTH SYNTHETIC FILTER FABRICS.
ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED
24" ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND
VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.)
CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT TO THE
LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY,
SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4'
MINIMUM OVERLAP TO THE NEXT POST.
SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED
SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE
MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE
REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE
POST. WIRE OR PLASTIC ZIP TIED SHOULD HAVE MINIMUM 50 POUND
TENSILE STRENGTH.
WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM
OF 8' APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE
GROUND A MINIMUM OF 24".
EXTRA STRENGTH FILTER FABRIC WITH 6' POST SPACING DOES NOT REQUIRE
WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC
DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE MINIMUM
50 POUND TENSILE STRENGTH.
EXCAVATE A TRENCH APPROXIMATELY 4" WIDE AND 8" DEEP ALONG THE
PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER.
PLACE 12" OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH.
BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND
COMPACT. THOROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT
FENCE PERFORMANCE.
DO NOT ATTACH FILTER FABRIC TO EXISTING TREES.
TEMPORARY SILT FENCE DETAIL
NOT TO SCALE
REVISIONS
SYM. DESCRIPTION DATE O b e a..a��H �RO(•y EROSION CONTROL
........� s JUNE/2019
o Ess�,' DETAILS DATE
SHORT STOP GAS STATION
• _ 9570
n Ineern PLLC ' ' HOKE COUNTY, NORTH CAROLINA
gy�9`�H��NE�4r�, PRELIMINARY DRAWINGS
h"" r UPGN,n• Y EC-5
150 S. Page Sfreet • Southern Pines, NC 28387. (910) 684-8646 • Cert. No. P-1275 "`"atelleE "" FOR REVIEW ONLY L SHEEr No.