Certificate of Coverage No. NCG03 0 2 4 6 Person Collecting Samples: Gregg Cook and Dalton Kaylor
Facility Name: Hickory Manufacturing and Technology Center Laboratory Name: Water Tech Labs
Facility County: Catawba Laboratory Cert. No.: 50
Discharge during this period: ❑■ Yes ❑ No (if no, skip to signature and date)
Has your facility implemented mandatory Tier response actions for any benchmark exceedances? Q Yes ❑ No
If so, which Tier (I, II, or III)? III
Analytical Monitoring Requirements for Outfalls with Industrial Activities - Benchmarks in (Redl
Parameter
Code
Parameter
Outfall 3
Outfall 5
Outfall
Outfall
Outfall
N/A
Receiving Stream Class
C
C
N/A
Date Sample Collected MM/DD/YYYY
12/14/2020
12/14/2020
46529
24-Hour Rainfall in inches
2
2
00552
Non -Polar Oil & Grease in mg/L (15)
<5.6
<5.6
C0530
TSS in mg/L (100 or 50*)
9.0
7.4
00400
pH in standard units (6.0-9.0)
5.63
6.59
NCOIL
New Motor/Hydraulic Oil Usage in
gal/month
N/A
N/A
01119
Copper, total recoverable in mg/L
(0.010 FW, 0.005 SW)
0099
< 005
01051
Lead, total recoverable in mg/ L
(0.075 FW, 0.220 SW)
G • 005
<.005
01094
Zinc, total recoverable in mg/ L (0.126
FW, 0.095 SW)
0.810
.0639
78141
Total Toxic Organics (TTO) in mg/L(1)
N/A
N/A
* Outfalls to Outstanding Resource Waters (ORW), High Quality Waters (HQW), Trout Waters (Tr) and Primary Nursery Areas (PNA)
have a benchmark T55 limit of 50 mg/L. All other water classifications have a benchmark of 100 mg/L.
Notes (optional):
"I certify by my signature below, under penalty of law, that this document and all attachments were prepared under my direction or
supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information
submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for
gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am
aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for
knowing violations." . -111,
Signature of Permittee or Delegated Authorized Individual
Date