Loading...
HomeMy WebLinkAboutNCS000330_2021 DMR_20210126January 26, 2021 Attn: Central Files N.C. Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Central Files: P.O. Box 5030 2020 Asheraft Avenue Monroe, NC 28111.5030 Phone: (704) 289-4511 Fax: (704) 290-5194 Email: Tyler.Mercer@ATlnietals.com Attached, please find stormwater monitoring data for ATI Specialty Materials — Monroe Plant Permit No NCS000330. The originals are included. A copy was also uploaded into the NPDES Stormwater Individual Permits website. The monitoring data is for the following monitoring schedule: M--------------------------- onito6ng Events" Sample Number Start End Year 3 — Period 1 4 January 1", 2021 June 301h° 2021 Stormwater sampling for Outfall # 02(M) has been determined to be the representative outfall through prior correspondence. 101 certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel proper lygather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible forgathering the information, the information submitted is, to the ,hest of my knowledge and belief, true, accurate, and complete. 1 am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." If you have any questions or need additional information, please contact me at 704.289-4511. Thank you. Sincerely, Tyler Mercer EHS Manager ATI Specialty Materials -Monroe Plant Stormwater Monitoring Report Form AAT1 Sample Date&Time: 1/7/21 11:07 pm Stormwater Discharge_Outfall #2 Sample Location: SW02 Person('s) Collecting Samples: Laboratory Performing Analysis: Analytical Techniques and Methods: Results of Sample Analysis: Drainage Area = 272'590sg. Ft. =6.25 acres Impervious = 36% James Moser Pace Analytic 40 CFR Part 136 Parameter Results (mg/1) Benckmark Values (mg/l) BOD > > .3 30 COD 46.7 120 TSS 16.7 100 Cadmium ND 0.003 Chromium, total recoverable 0.0138 1 Lead, total recoverable ND 0.03 Nickel, total recoverable 0.048 0.335 Zinc, total recoverable 0.192 0.126 Oil & Grease ND 15 H 7.1 6-9 (std units) Storm Date: 117/21 11:07pm Storm Duration: 18.5 (Hrs.) Inches of Rainfall: 0.65" Duration of time preceding rain event exceeding 0.1": 92.5 (Hrs.) Estimated Flow Calculation: Q=CIA Q(Total)= Q(Pervious Area)+ Q(Impervious Area) Q(tot, cfs) = (.4 x inches rain/12inches/ft. x 6.25 acres x .64) + .9 x inches rain/12inches/ft. x 6.25 x .36) Q(Total, cfs)= .1333 X 0.65" (inches of rain) + .1688 X 0.65" (inches of rain) = •976 cfs 0 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this, form, please visit https://deq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: N/C/ S101010I31310 or Certificate of Coverage No.: NIC/G/ I I I I I l Facility Narne: ATI Specialty Materials -Monroe County: Union Phone No. 704-289-4511 Inspector: James Moser Date of Inspection: 117121 Time of Inspection: 1 1:35 pin Total Event Precipitation (inches): 0.65" All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (SiPture of Permittee or Designee) 2. Outfall Description: (outfall No. 01 Structure (pipe. ditch. etc.): Pi Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage Page 1 of 2 SwU-242, Last modified 06/01 /2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: very fight gray 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy- 1 2 3 4 5 7. Is there any foam in the stormwater discharge? o Yes f No. S. IS there an oil sheen in the stormwater discharge? 0Yes ■ No. 9. Is there evidence of erosion or deposition at the outfall? o Yes ■ No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modificd 06/01/2019 Environmental Quality Stormwater Discharge Outfall (SD4) Qualitative Monitoring Report For guidance on filling out this form, please visit https:l/deq.ne.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: N/C/ S101010131310 or Certificate of Coverage No.: N/C/G/ Facility Name: ATI Specialty Materials -Monroe County: Union Phone No. 704-289-4511 Inspector: James Moser Date of Inspection: 1 /7121 Time of Inspection 11:44 pm Total Event Precipitation (inches): 0.65" All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DI MLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: y e- fk6,-4-4 of Permittee or Designee) 1. Outfall Description: Outfall No. Q2 Structure (pipe, ditch, etc.): Pipe Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storace Page 1 of 2 SwU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: very light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? o Yes ■ No. S. Is there an oil sheen in the stormwater discharge? oYes M No. 9. Is there evidence of erosion or deposition at the outfall? o Yes ■ No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 sWU-242, Last modified 06/01/2018 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-stormwater-gps Permit No.: NIC/ S10/010131310 or Certificate of Coverage No.: NICIGI l 1 I I I I Facility Name: ATI Specialty Materials -Monroe County: Union Phone No. 704-289-4511 Inspector: James Moser Date of Inspection: 1 /7/21 Time of Inspection: 1 1:53 prn Total Event Precipitation (inches): 0.65" All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: *vvrlb Iz- (Si4n4ture of Permittee or Designee) 1. Outfall Description: outfall No 03 Structure (pipe, ditch, etc.): Pipe/Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage, Hammer Repair Dust Collection Pagel of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: liaht brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where l is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? O Yes ■ No. S. Is there an oil sheen in the stormwater discharge? OYes M No. 9. Is there evidence of erosion or deposition at the outfall? O Yes M No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modifcd 06/01/2018 1=nvironmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on f lling out this form, please visit https:i/deq.nc.gov/about/divisionr,/energy-mineral-land-resources/ npdes-stormwater-gp s Permit No.: NICI Facility Name: county: Union S/0/010I3/3/0 or Certificate of Coverage No.: NICIGI l I 1 I I I ATI Specialty Materials - Monroe Inspector: James Moser Date of Inspection. 1 /8/21 Time of Inspection: 12.15 of fl Total Event Precipitation (inches): 0.65" Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Si ature of Permittee or Designee) 1. Outfall Description: outfall No. 04 Structure (pipe, ditch, etc.): Pipe/Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Shipping Staging, Turnings Storage, Truck Loading Page 1 of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 w 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where I is no solids and 5 is extremely inuddy: 1 L 3 4 5 7. Is there any foam in the stormwater discharge? o Yes M No. 8. Is there an oil sheen in the stormwater discharge? OYes M No. 9. Is there evidence of erosion or deposition at the outfall? O Yes MNo. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 06/01/2018 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeq.nc.gov/about/divisions/energy-mineral-land-resources/ npdes-storrnwater-gps Permit No.: N/C/ S/0/0/0/3/3/0 or Certificate of Coverage No.: N/C/GI Facility Name: ATI Specialty Materials- Monroe County: Union Phone No. 704-289-4511 Inspector: James Moser Date of Inspection: 117121 Time of Inspection: 11:25 Total Event Precipitation (inches): 0.65" All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge- (Sigtature of Permittee or Designee) I. Outfall Description: outfall No. 05 Structure (pipe, ditch, etc.): Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Metal Storage, Clean Empty Drums, Equipment Storage, Roll Off Containers Page 1 of 2 SwU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Eight brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 7. S. 9. 1 2 3 4 5 Is there any foam in the stormwater discharge? o Yes 0 No. Is there an oil sheen in the stormwater discharge? OYes MNo. Is there evidence of erosion or deposition at the outfall? O Yes 0 No. 10: Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 5wU-242, Last modified 06/01/2018 Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit ht(ps:Hdeq.nc.gov/about/divisions/energy-mineral-land-resourcesi npdes-stormwater-gps Permit No.: N/C/ Facility Name: County: Union S/0/0/0/3/3/0 or Certificate of Coverage No.: N/C/GI ATI Specialty Materials - Monroe Inspector: ,lames Moser Date of Inspection: 1 /8/21 Time of Inspection: 1205 am Total Event Precipitation (inches): 0.65" Phone No. 704-289-4511 All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: W'd / yY7o�,C" of Permittee or Designee) 1. Outfall Description: Outfall No. 06 Structure (pipe, ditch, etc.): Ditch Receiving Stream: Richardson Creek Describe the industrial activities that occur within the outfall drainage area: Trash Compactor, Metal Storage, Parking Lot Pagc 1 of 2 SWU-242, Last modified 06/01/2018 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: light brown 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): none 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 2 3 4 5 7. Is there any foam in the stormwater discharge? o Yes M No. S. Is there an oil sheen in the stormwater discharge? 0Yes M No. 9. Is there evidence of erosion or deposition at the outfall? O Yes ■No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SwU-242, Last modified 06/01 /2018 0 a N It ft R a a IG U CO 1Cc r! U ad PW .—I U_ c O U) N z wU0 W Aa �aa z0A �• U W wRw,U LO co A y O F � � ..V•ny p O C c^ N 0 w � oz° Sr C E zo `1 Q Q h o o� °'H~ zoo Q y � a a O N � K O v a G O th � CC O H � i I � y ' 93 03 G i E � y ,oA 'mar.• ti [V O F4 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 January 19, 2021 Tyler Mercer ATI Specialty Materials 2020 Ashcraft Avenue Monroe, NC 28110 RE: Project: Monroe Stormwater SW02 Pace Project No.: 92515732 Dear Tyler Mercer: Enclosed are the analytical results for sample(s) received by the laboratory on January 08, 2021. The results relate only to the samples included in this report. Results reported herein conform to the applicable TNI/NELAC Standards and the laboratory's Quality Manual, where applicable, unless otherwise noted in the body of the report. The test results provided in this final report were generated by each of the following laboratories within the Pace Network: • Pace Analytical Services -Asheville • Pace Analytical Services - Charlotte If you have any questions concerning this report, please feel free to contact me. Sincerely, Matthew Brainard matthew.brainard@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Mr. Tommy Long, Allvac Mike McManus, ATI Specialty Metals Scott Ryan, Allvac REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Monroe Stormwater SW02 Pace Project No.: 92515732 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Virginia/VELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 SAMPLE ANALYTE COUNT Project: Monroe Stormwater SW02 Pace Project No.: 92515732 Lab ID Sample ID Method Analysts Analytes Reported Laboratory 92515732001 Monroe SW02 EPA 1664B JSG 1 PASI-C EPA200.7 Rev 4.4 1994 SH1 5 PASI-A SM 2540D-2011 RED 1 PASI-A SM 5210B-2011 NFW 1 PASI-A SM 5220D-2011 NAL 1 PASI-A PASI-A = Pace Analytical Services - Asheville PASI-C = Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: Monroe Stormwater SW02 Pace Project No.: 92515732 Sample: Monroe SW02 Lab ID: 92515732001 Collected: 01/07/21 23:11 Received: 01/08/21 07:30 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual Field Data Analytical Method: Pace Analytical Services - Charlotte Performed by ATI SM 1 01/07/21 23:18 Collected By TL 1 01/07/21 23:18 Collected Date 01/07/21 1 01/07/21 23:18 Collected Time 23:07 1 01/07/21 23:18 1664 SGT-HEM, TPH Analytical Method: EPA 1664B Pace Analytical Services - Charlotte Total Petroleum Hydrocarbons ND mg/L 5.0 1 01/18/21 17:22 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Pace Analytical Services - Asheville Cadmium ND ug/L 1.0 1 01/12/21 16:50 01/14/21 00:48 7440-43-9 Chromium 13.8 ug/L 5.0 1 01/12/21 16:50 01/14/21 00:48 7440-47-3 Lead ND ug/L 5.0 1 01/12/21 16:50 01/14/21 00:48 7439-92-1 Nickel 48.0 ug/L 5.0 1 01/12/21 16:50 01/14/21 00:48 7440-02-0 Zinc 192 ug/L 10.0 1 01/12/21 16:50 01/14/21 00:48 7440-66-6 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Pace Analytical Services - Asheville Total Suspended Solids 16.7 mg/L 2.9 1 01/11/21 18:16 5210B BOD, 5 day Analytical Method: SM 521OB-2011 Pace Analytical Services - Asheville BOD, 5 day 11.3 mg/L 2.0 1 01/09/21 03:20 01/14/21 00:45 B3 5220D COD Analytical Method: SM 5220D-2011 Preparation Method: SM 5220D-2011 Pace Analytical Services - Asheville Chemical Oxygen Demand 46.7 mg/L 25.0 1 01/10/21 13:57 01/11/21 10:50 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 4 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Monroe Stormwater SW02 Pace Project No.: 92515732 QC Batch: 593498 Analysis Method: EPA 1664B QC Batch Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Laboratory: Pace Analytical Services - Charlotte Associated Lab Samples: 92515732001 METHOD BLANK: 3132067 Associated Lab Samples: 92515732001 Parameter Units Total Petroleum Hydrocarbons mg/L LABORATORY CONTROL SAMPLE: 3132068 Parameter Units Total Petroleum Hydrocarbons mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 01/18/2116:53 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 20 15.6 78 64-132 MATRIX SPIKE SAMPLE: 3132069 92515583002 Spike MS MS % Rec Parameter Units Result Cone. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L ND 20 ND -2 64-132 M1 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 5 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Monroe Stormwater SW02 Pace Project No.: 92515732 QC Batch: 592152 Analysis Method: EPA 200.7 Rev 4.4 1994 QC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92515732001 METHOD BLANK: 3125803 Matrix: Water Associated Lab Samples: 92515732001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Cadmium ug/L ND 1.0 01/13/2123:21 Chromium ug/L ND 5.0 01/13/2123:21 Lead ug/L ND 5.0 01/13/2123:21 Nickel ug/L ND 5.0 01/13/2123:21 Zinc ug/L ND 10.0 01/13/2123:21 LABORATORY CONTROL SAMPLE: 3125804 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Cadmium ug/L 500 477 95 85-115 Chromium ug/L 500 445 89 85-115 Lead ug/L 500 503 101 85-115 Nickel ug/L 500 483 97 85-115 Zinc ug/L 500 486 97 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3125805 3125806 MS MSD 92515201001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Cadmium ug/L ND 500 500 498 497 100 99 70-130 0 Chromium ug/L ND 500 500 453 455 90 91 70-130 0 Lead ug/L ND 500 500 513 512 103 102 70-130 0 Nickel ug/L ND 500 500 489 490 98 98 70-130 0 Zinc ug/L 0.22 500 500 721 720 100 100 70-130 0 mg/L MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3125807 3125808 MS MSD 92515600008 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Cadmium ug/L ND 500 500 487 484 97 97 70-130 1 Chromium ug/L ND 500 500 452 447 90 89 70-130 1 Lead ug/L ND 500 500 509 502 102 100 70-130 1 Nickel ug/L ND 500 500 483 480 96 96 70-130 0 Zinc ug/L 116 500 500 612 609 99 99 70-130 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 6 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Monroe Stormwater SW02 Pace Project No.: 92515732 QC Batch: 591923 Analysis Method: SM 2540D-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92515732001 METHOD BLANK: 3124975 Associated Lab Samples: 92515732001 Parameter Units Total Suspended Solids mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.5 01/11/2118:01 LABORATORY CONTROL SAMPLE & LCSD: 3124976 3125127 Spike LCS LCSD LCS LCSD % Rec Max Parameter Units Conc. Result Result % Rec % Rec Limits RPD RPD Qualifiers Total Suspended Solids mg/L 250 242 240 97 96 90-110 1 25 SAMPLE DUPLICATE: 3125128 92515776001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 178 172 3 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 7 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Monroe Stormwater SW02 Pace Project No.: 92515732 QC Batch: 591664 Analysis Method: SM 521 OB-2011 QC Batch Method: SM 521 OB-2011 Analysis Description: 5210B BOD, 5 day Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92515732001 METHOD BLANK: 3123899 Associated Lab Samples: 92515732001 Parameter Units BOD, 5 day mg/L LABORATORY CONTROL SAMPLE: 3123901 Parameter Units BOD, 5 day mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 2.0 01/14/2100:23 B3 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 198 206 104 84.6-115 B3 SAMPLE DUPLICATE: 3123902 92515568001 Dup Parameter Units Result Result BOD, 5 day mg/L 153 141 RPD Qualifiers 8 132,133 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 8 of 12 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Monroe Stormwater SW02 Pace Project No.: 92515732 QC Batch: 591728 Analysis Method: SM 5220D-2011 QC Batch Method: SM 5220D-2011 Analysis Description: 5220D COD Laboratory: Pace Analytical Services - Asheville Associated Lab Samples: 92515732001 METHOD BLANK: 3124056 Associated Lab Samples: 92515732001 Parameter Units Chemical Oxygen Demand mg/L LABORATORY CONTROL SAMPLE: 3124057 Parameter Units Chemical Oxygen Demand mg/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 25.0 01/11/2110:41 Spike LCS LCS % Rec Cone. Result % Rec Limits Qualifiers 750 755 101 90-110 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3124058 3124059 MS MSD 92515433001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 126 100 100 224 224 98 98 90-110 0 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 3124060 3124061 MS MSD 92515459001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Cone. Cone. Result Result % Rec % Rec Limits RPD Qual Chemical Oxygen Demand mg/L 192 100 100 295 295 102 102 90-110 0 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 9 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: Monroe Stormwater SW02 Pace Project No.: 92515732 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. ANALYTE QUALIFIERS B2 Oxygen usage is less than 2.0 for all dilutions set. The reported value is an estimated less than value and is calculated for the dilution using the most amount of sample. B3 The dissolved oxygen depletion of the dilution water blank exceeded 0.2 mg/L. M1 Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 01 /19/2021 07:22 AM without the written consent of Pace Analytical Services, LLC. Page 10 of 12 aceAnalytical www.paeelabs.enm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Monroe Stormwater SW02 Pace Project No.: 92515732 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92515732001 Monroe SW02 92515732001 Monroe SW02 EPA1664B 593498 92515732001 Monroe SW02 EPA 200.7 Rev 4.4 1994 592152 EPA 200.7 Rev 4.4 1994 592260 92515732001 Monroe SW02 SM 2540D-2011 591923 92515732001 Monroe SW02 SM 5210B-2011 591664 SM 5210B-2011 591695 92515732001 Monroe SW02 SM 5220D-2011 591728 SM 5220D-2011 591807 Date: 01 /19/2021 07:22 AM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 11 of 12 ATI Specialty Materials OATI Monroe Speclalty Materials Chain of Custody Record Project Name/Number: Vonroe Stormwater SW02 Project Location: Monroe/Ashcraft Facility Sampler(s) Signature: �� Date: .. 7.� CL c a � � Requested o E �? li p Parameters 0 li' 7-oZ� ;Qg G/P' None Y TSS OC� is G/P None I Y BOD l*; tb G/P H2SO4 Y COD c� Oil & Grease Non -Polar Oil &Grease by G/P HCL Y EPA Method 1664 SGT-HEM a mlum, Chromium, Lead, / it ] ; �' G/P HNO3 Y Nickel, Zinc Benchmarks TSS 100 mg/L BOD 30 mg/L COD 120 mg/L OIL &Grease 15 mg/L Cadmium 0.003 mg/L Chromium 0.905 mg/L Nickel 0.335 mg/L Lead 0.03 mg/L Zinc 0.126 mg/L Onsite Field Analysis Onsite Field Temperature Analysis pH: 7,, Sample Time: , 6 7 m Temp: , & °C Sample Time: /L Analysis Time: (: j g r'r1 Analysis Timer 1. 0 6 M Sampling and Field Analysis completed by: Relinquished by. DaTime: � j1� Received by: Dater Time:-- 07 � EHS-ENV-SW-COC Rev.001 L lz- �fs C Page 12 of 12