HomeMy WebLinkAboutNCG020108_Regional Office Historical File Pre 2018 (3)Y fr ,PAT MCCRORY Govemor, DONALD R. VAN DER VAART Secretary Environmental Quality September 14, 2016 Mr. Tony Johnson Environmental Engineer Vulcan Materials Company 4401 North Patterson Ave Winston Salem, NC 27115 Subject: Multimedia Compliance Inspection Vulcan Materials Company — Gold Hill Cabarrus County Dear Mr. Johnson: Ori Tuvia from the Mooresville Regional Office conducted' a multimedia compliance inspection of Vulcan Materials Company - Gold Hill on September 7, 2016 for permits and programs administered by the following Divisions: Mining Mining Permit Number: 13-04 Division of Air Quality Air Quality Permit Number: 05099R19 Division of Energy, Mineral. and Land Resources Stormwater Permit Number: NCG020108 Division of Waste Management EPA ID: NCS000002366 Your and Jordan Littauer Cooperation during the multimedia inspection was much appreciated. Enclosed are the Mining, air quality, stormwater inspection and waste management reports. If you have any questions regarding this multimedia inspection, please contact Ori Tuvia, Division of Water Resources at (704)663-1699. Enclosure: Mining Report Air Quality Inspection Report Stormwater Inspection Report Waste Management Report c: DAQ MRO Files DEMLR MRO Files DWR MRO Files DWM MRO Files H:\inspections\Multimedia\Gold Hill Quary\DEQ-MRO Multimedia Vulcan gold hill inspection - 9-7-2016.docx State of North Carolina I Environmental Quality I Mooresville Regional Office Mooresville Regional Office 1 610 E. Center Ave Suite 301 1 Mooresville, NC 28117 704-663-1699 T 1 704-663-6040 F North Carolina Department of Environment and Natural Resources, Division of Energy, Mineral, and Land Resources, Land Quality Section MINE INSPECTION REPORT N PERMITTED MINE SITE ❑ UNPERMITTED MINE SITE 1. MINE NAME: Gold Hill Quarry 2. MINE LOCATION: Old BegM Road 3. COUNTY: Cabarrus 4: RIVER BASIN: Yadkin 5. CASE: . 6. OPERATOR: Vulcan Materials Company 7. ADDRESS: 4401 North Patterson, Winston Salem, NC 27115 Attn. Topy Johnson 8. MINING PERMIT #: 13-04 ❑ N/A 9. PERMIT EXPIRATION DATE: 08/21/2022 ❑ N/A 10. PERSON(S) CONTACTED AT SITE: Tony Johnson, Jordan Littauer 11. PICTURES?-- ❑ Yes N No TAKEN BY: 12. TYPE OF INSPECTION: ❑ A. Initial Inspection (Unpermitted Mine Sites) 1. Size of affected land: ac. (attach sketch map) 2.. How was this area measured? Measured by: N B. Routine Inspection (Permitted Mine Sites) ❑ C. Follow-up Inspection 13. Date of last inspection: 08/05/2014 14. Any mining since that date? N Yes ❑ No If yes, cite evidence of such mining activity: There was mining activitv during the insuection 15. Was mine operating at time of inspection? N Yes ❑ No If yes, explain: There was mining activi 16. Is the mine in compliance with the Operating Conditions of the Permit? X Yes U No U N/A If no, explain: 17. Is the mine in compliance with the Reclamation Conditions of the Permit? ❑ Yes ❑ No. N N/A If no, explain: 18. Is there any off -site damage? A. ❑ Yes B. ❑ No C. N None observed If A, describe the type and severity of the damage: If B or C,'is there potential for offsite damage? ❑ Yes ® No Explain: Potential discharge have significant periods of settling time in large retention areas prior to discharge. 19. Corrective measures needed and/or taken: None 20. Other recommendations and comments: Continue to follow the operating conditions of this permit 21. Is the Annual Reclamation Report +/- map..accurate? N Yes ❑ No (Explain) ❑ Not Reviewed. ❑ N/A Annual Reclamation Report for 2015 was reviewed duringthe he inspection facilitystaff confirmed it to be accurate. 22. Follow-up inspection needed? ❑ Yes N No Proposed date 23. No. of additional pages -of Inspection Report 0 24. Copy of Report sent to operator INSPECTED BY: Ori Tuvia DATE 9/7/2016 Telephone No: 704-663-1699 Copy to file Copy to operator Copy .to Mining Specialist NORTH CAROLINA DIVISION OF Mooresville Regional Office AIR QUALITY Vulcan Construction Materials, LLC - Gold Hill Quart Inspection Report NC Facility ID 1300067 Date: 09/07/2016 County/FIPS: Cabarrus/025 • F l Facility Data Permit Data Vulcan Construction Materials, LLC - Gold Hill Quarry Permit . 05099 / R.19 16745 Old Beatty Ford Road - Issued 10/1/2015 Gold Hill, NC .28071 Expires. 3/31/2022 , ' Lat:.35&30.1610m Long: 80d.19.8810m Classification Small SIC: 1411 % Dimension Stone Permit Status. Active 1VAICS: 212311 /Dimension Stone Mining and Quarrying Current Permit Application(q). None . Program Applicability Contact Data SIP, Facility Contact Authorized Contact Technical Contact ;. Jordan Littauer Martin: Thorpe Tony Johnson NSPS: Subpart 000 Plant Manager Vice President . Environmental Engineer. (704) 279-5566 (336) 744-7013 (704) 547-7076 . Comments: Multimedia ;✓-.(2 — lo Compliance Data - Inspection Date 09/07/2016 . . Inspector's Name Ori:. Tuvia Inspector's Signature: Operating Status Operating .®� Compliance Code Compliance - inspection Action Code :.. FCE _ Date of Signature: : C % F / On=Sit e Inspection Result Comphanee Total Actual emissions in TONS/YEAR:.: TSP. S02 NOX VOC CO PM1.0 * AAP ;. 2013 4.801.80 --- _ --- 2008 • 4.79 03,500 2 24' . ` 0:0600: 0.6000 1,76 1.09.. Higliest HAP Emitted (in ounds) Five Year=Violation History: None Date Letter Tyne Rule Violated . Violation Resolution Date Performed Stack Tests since last FCEc Date Test Results Test Method(s) Source(s) Tested 07/13/2016 Compliance Method d 9 BS-Convey. Vulcan Construction Materials, LP - Gold Hill September 7, 2016. Page 2 Type Action; X Full Compliance _ Partial Compliance Evaluation Evaluation/Reinspecton Data Date submitted for initial review:: 09/09/2016 Tracking: j.L IBEAM Inspection, list date inspected -L IBEAM Inspection, list date draft is submitted -L IBEAM Inspection, pollutants/programs checked —Complaint Oth6r: Investigation _ IBEAM WARNIN NOD,. NOV, NRE... X IBEAIVLDocuriient` — IBEAM. LA.TILONG, Facility Locked _X IBEAM LATILON69 Coordinates checked . IBEAM Complaint X IBEAM Planning, Next Iiispe.ction.Date:.:; .09/01/2018 Directions to Facility: Travel from Mooresville to Gold Hill dia.NorthMain Street; turn right on Highw6y.150 East; turn right: on Highway 152 East towards China Grove; turn right on.Highway. 52 South in.Rockwell; approximately 1 %Z miles from: Gold Hill turn right off Highway 52 South onto Old Beatty Ford Road. Vulcan Construction Materials, LP; Gold.Hill- Quarry,. islocated 0,7 mile on the left past Carolina Stalite. The address :of this facility is 16745 Old Beatty Ford .Road. Safety Issues: Inspectors should be aware of rock falling from conveyor belts overhead when touring plant. Be:aware of vehicle traffic coming in and out of the. site. . -Safety Equipment: This company requires that. a hard hat, steel=toe shoes; and safety glasses be worn by the inspector at_ this facility. Lat/LonjzCoordinates: The latllong.coordinates in IBEAM have been checked and-..appearto be accurate:: Emails: The email addresses for each contact were verified, Changes were made as needed: ,Purposeof IhsPecdon.. ; The purpose.of this. site visit was to conduct a multimedia inspection of Vulcan Construction Materials, LP; Gold Hill Quarry. Mr. Jordan Littauer, Plant Manager and Mr. Ton ' ,Johnson Environmental Engineer accompanied me during inspecti . Vulcan Construction Materials LP Gold. Hill . u is en a ed in the i m crushin and screenin of °� QY g g quarrying, g� .. g slate stone: This company operates this plant five: hays per week, .eight hours per. day, and fifty weeks per:year. The ': `operationalschedule of this facility is solely dependent up weather conditions and customer orders:. Facility Contactlnformd* don: During the. inspection, I verified the facility contact information in IBEAM with Mr. Littauer. Changes were made to the plant Manager and Vice president contacts. Compliance history fle.re'view: No problems have been noted in the last five years.by DAQ pdor.to this inspection. Vulcan Construction Materials,. LP — Gold Hill September 7; 2016 Page 3 Air emission sources and control devices listed in the current permit: . _......: -__..__..._......_..._..__......_................... _..._..._._...._...._..._...._..... _ ..................._....... _.._.__....... ....... ... — Emission Source ID' Emission Source DescriptionFm, Control ( Control System Description ....... ------- - --- steID Non-metallic Mineral Processing Plant with 1,200 tons per hour rating; utilizing water suppression with no other nt -fd... , co ro evices,:includin _.... ..._._............................._._..._..... g Crushing Operations N/A N/A NSPS _. _. .:...... _.:_ ._ — - - - ....._... . �ES Screen Screening Operations N/A N/A NSPS __ .._....._ __._. ing Ope NSPS rations N/A N/A ES -Convey ............ . . . Observations. of permitted air emission sources and control devices: TABLE 1- CRUSHERS ID Nos. In Operation Wet. &• NSPS es or No Opacity' Opacity Suppression P ty Equipment Description Notification)During MFG. Affected During ; Observed Limit Testing o o Inspection Dates (Yes/No) Inspection : (/o) (/o) (Yes or No) Nordberg Model C125. CRl Primary Jaw Crusher Yes T — Not 1996. Yes 0-5 .15 Yes (545-tph) .. LFL - Required on LFL 5 1/2 Standard CR2* . Nordberg Cone.Crusher Yes 0=5 (750 tph) 1962 No. N/A-: 40- Yes Nordberg Model HP 400 Cone . Crusher CR3 * Yes . N =::C : _.. Yes 0-5 15 Yes (640 tph) 1997 T — 4/98. Table Notes: N C refers to.Notification , Completed;'I= Month/Year refers to Method 9 (V.E.) Testing Date; W - Waiver from Testuig LFL =Like for Like. Replacement * One feeder (ID, No. F7) is located above the 5 %- Standard Nordberg Cone Crusher (ID No. CR2) and one feeder (ID No. F8) is located above the Nordberg Model HP400 Cone Crusher (11) No. CR3).: These feeders (ID Nos. F7 and. Vulcan Construction Materials, LP - Gold Hill September 7, 2016 Page 4 F8) are not required to be permitted per policy memo dated November l8; 1996' and exempt per 15A NCAC 2Q .0102 (c)(2)(E)(i) TABLE 2= FEEDER & SCREENS ID Nos. & NSPS Notification/ In Operation Opacity Opacity- Wet AUG Affected Testing N (Yes or o) Observed Limit Suppression Equipment Dates' (Yes/No) During, (%) (%) During Description ;Inspection .Inspection _ (Yes or No) Vibrating Grizzly Feeder F1 o N/A 'Yes . 60" x 24' 1971 (500 tph) .6' x 16' Deister S 1• . Yes N — C Yes N/A 10 Yes Triple Peck Dry Screen 1994 T — 8/95 S2** :. Yes `` N'-.0 Vi 20' Deister 1988 (LFL) T—Not Yes N/A Yes Triple Deck Dry Screen Required. on LFL .. 8' x 20' Deister Triple Deck Dry or Wet Screen S4 2007 19 -Yes .N = C T - Not lequired on LFL' No N/A 0' Wet .­ 10-Dry :. N/A S5 . Yes N - C 6' x 16'• Deister 2007 T Not Triple.Deck.Wash Required on No NIA 0 .:_. N/A Screen LFL * * One feeder No. F6 is located after the triple screen. No S 2 but prior to belt conve or No. C-4 . (II) )dry. (ID ) p. y (ID ) This feeder is not required to be permitted per'polic:-memo dated November 18, 1996, and exempt per 15A NCAC 2Q ..0102 •(,)(2)(E)(i) Vulcan Construction Materials, LP — Gold Hill ' September 7, 2016 Page 5 TABLE.3- CONVEYORS Equipment Equipment NSPS Notification/ In Opacity Opacity Wet Description ID Nos._.& Affected ,. ;; :Testing Operation Observed Limitation Suppression MFG Dates (Yes or No).. .: (Yes or. No) (%) (%) During During Inspection Inspection (Y ) es: or No Conveyor • C-1 C4 Yes N — C 10 N/A Belt Width .48" 1994 T - 8/95 . yes N/A Conveyor C-2 C-2 Yes N — C 10 :N/A Belt Width 48" 1994 T — 8/95 yes N/A Conveyor'C-3 C-3*** Yes N — C 10 Belt Width-42" 1994 : T — 8/95 .. Yes N/A . N/A Conveyor C-4 C-4 Yes N - C, 10 Belt Width 36" 1994 T — 8/95 Yes . N/A N/A Conveyor C-5 '.C-5 Yes N — C 10 - Belt Width 36" - 2002 T -Not Required on .. Yes N/A N/A . LFI; Conveyor .C-6 C-6 Yes N - Belt Width 42"- 1995 T = 8/. Yes N/A' N/A' Conveyor C77 C-7 Yes . N =- C 10 Belt Width 36" 1995 ` T = 8/9S Yes . N/A NIA Conveyor.C-8 C-8*** Yes -N=C ' Yes N/A Belt Width 36" 1995 T - 8/95 No N/A Conveyor C-9 G9 Yes N = C Vulcan Construction Materials, LP - Gold Hill September 7, 2016 Page 6 TABLE 3- CONVEYORS Equipment.. .. Equipment NSPS.. Notification/ : In Opacity Opacity - - Wet Description ID Nos. &. Affected Testing Operation Observed Limitation Suppression 1VIF'G Dates (Yes or No) (Yes`or No). (0/6) During ; During Inspection Inspection (Yes or No) Belt Width 30" 1994 T - 8/95 b. Conveyor C-10 C-10 Yes N _ C . .. No: N/A, 10 N/A Belt Width 30" 1994 T — 8/95 Conveyor C`-11 C-11 Yes N = C No N/A: 10 N/A Belt Width 36" 1995' T 8/95 Conveyor G12 C-12 Yes N = C No N/A 10 N%A Belt Width 36" 1995 , T - 8/95 .,N/A Conveyor C-16 C-16 Yes N- C No. N/A' 10 B.e1t.Width 36" 1994 T — 8/95... ...:. N/A Conveyor C=17 C-17 Yes N- C No N/A. 10 Belt Width: 36" 1995 T — 8/95 N/A Conveyor C=18 C48 Yes W — 8/95 No N/A. 0 Belt Width 30" 1994 Conveyor: C-19 C-19 Yes W —'8/95 No N/A 0 N/A :. Belt Width 30" 1994 Conveyor C-20 C-20 Yes W-8/95 No N/A 0. N/A Belt Width' 0" 1994 Conveyor C721 C-2.1 * * * Yes. N .- C Yes . N/A . 10 N/A Belt Width 30" 1995, T - 8/95 Conveyor C-22' C-22*** Yes N =. C . No N/A` 10 N/A Belt Width 30.': .' 1995..T = 8/95. Stalite Belt Vulcan Construction Materials, LP — Gold Hill September 7, 2016 Page 7 `:TABLE 3-:CONVEYORS Equipment Equipment, NSPS Notification/ .... .: In` Opacity . Opacity. We..t Description :. ID Nos...& Affected Testing ..... ,Operation.:.: Observed Limitation Suppression MFG Dates es or N. . .:. During During Inspection Inspection (Yes or No) Conveyor C-23 C-23 Yes N - C No N/A 10 N/A Belt Width 3611 1997 T — 9/98 Conveyor SC-1 SC-1 Yes N _ C No, • N/A 10 N/A ; `Belt Width 30" 1995 T= 8/95 . Conveyor SC-2. SC72 j -. Yes. N-C.. No . „. N/A_ 10..... N/A,. Belt Width 36" 2001 T - 4/05 Conveyor SC-3 SC=3 -No ,N/A-.`-- No N/A .,.. 40 .- ..:.. :. -N/A Belt. Width 24." 190Q.: .. **'k< Three feeders (ID Nos. F2, F3, and F4) are located in the surge tunnel prior to belt conveyor (ID No. G-3). One feeder -(ID No. F5) is located prior to belt conveyor (ID No. C-8). Four feeders (II) Nos. F-9, F-10, F-11, and F-12) are located in the Stalite tunnel prior to belt conveyor (ID N. C-22). One feeder (ID No: F-13) is located in surge:tunnel prior to belt conveyor (IIID No. C-21), These feeders are not required to be permitted per policy memo dated November 18, 1996,'a6d 'exempt per 15A NCAC 2Q..0102.(c)(2)(E)(i)•. TABLE 4-B11vS.. Equipment . Equipment NSPS Notification/ In Wet Description ID Nos. & ' Affected Testing Operation :: Opacity:: Opacity Suppression MFG Dates (Yes or No) (Yes or No) Observed Limitation During .., :. ::.. During :. (%) .:...: (%o):.: Inspection Inspection. (Yes or No) Storage Bin SB4 Yes N — C Yes N/A 10 N/A . (75aons)­:.: ' 1994 T'_ 8/95 Storage Bin SB-2 Yes N — C yes . N/A 10 :,N/A (75 tons) 1994 T — 8/95 Vulcan Construction Materials, LP — Gold Hill September:7, 2016 Page 8 TABLE 5-WASH SCREW Equipment Equpmentt NSPS Notification/ 'In Opacity Opacity :Wet Description lD Nos. & Affected Testing . Operation. ` Observed Lim_ ita�tion Suppression MFG Dates' (Yes or No).' (Yes or No) (%) (%) During I During Inspection Inspection (Yes or No) Double Wash SS-1 Yes T-1903 No N/A 0 N/A Screw (Sand Screw) 44" x ; 33' Observations of insignificant air emission sources and control devices listed on the current permit: - ..::Source: = Source Exemption Regulation -- Observations ID No. Propane fired pressure ` �IES-2 2Q .0102 (c)(2)(B)(u) The pressure washer was not in operation during washer the. inspection. Observations of insizitirtcant ait emission sources and control de'v ees not listed 6h the-diiMit peiMit: 1. The company has the following aboveground tanks: one 20;000 gallon to store off -road diesel fuel utilized by the rock drill • off-road:trucks, machinery, loaders, and water truck; one 1,000:;gallon tank to store unleaded. gasoline utilized by the company pickup, trucks; one S00 gallon antifreeze tank, and one 1,000 gallon waste oil tank Tlie tanks are exem `t er 15A NCAC 2 0102 ` c 1 D i 'and ii .. One 250. gallon propane tank `is utilized for the `pressure washer (exempt item No. IES-2; model, Alkota Cleaning Systems, Inc:) and to fill 20 pound cylinder tanks `in order to melt the frost off belt conveyors. The tank is exempt per, 15ANCAC 2Q :0102 (6)(1)(D)(i). 3. A System.One type parts washer containing mineral spirits: is utilized to clean vehicle and machinery parts in, the . maintenance building of :this facility. The liquid in this parts washer is: recycled.. The parts washer is exempt per 15A NCAC 2Q .0102 (c)(1)(A)(i) 4. A diesel -fired rock drill is utilized by this company in the quarry'area. This drill is exempt per 15A NCAC 2Q .0102 Vulcan Construction Materials, LP — Gold Hill September 7, 2016 'Page 9 Compliance with.specirc permit conditions and limitations: 1 Specific Condition and Limitation No. A. 3. "Equipineni Reporting" states that the Permittee shall maintain. site an equipment list and a plant (or flow) diagram for Alt equipment covered under this permit. Facility had the required equipment. list and flow diagramfor this plan.. Compliance wiih this stipulation. is 'indkated . 2. Specific Condition and Limitation No. AA.' "Particulate Control Requirement" as required by 15A.NCAC 2D..0510 "Particulates from Sand, Gravel, or Crushed Stone Operations" states as follows: a. The Permittee of a sand, gravel, or crushed stone operation shall not cause, allow, or permit any material to be.produced. handled, transported. or stockpiled without taking measures to _reduce to, a minimum any particulate matter frori becoming airborne to prevent exceeding the ambient air quality standards beyond the property line for particulate matter, boih PM10, and total suspended particulates; TSP." b. Fugitive non -process dust. emissions from sand, gravel, or crushed stone operations shall be controlled by l 5A NCAC 2D .0540 "Particulates from Fugitive Non -Process Dust Emissions Sources" C. The Permittee of any sand, gravel, or crushed stone operation shall control process -generated emissions: i. From crushers with wet suppression; and . ii. .. , From conveyors, screens, and transfer points. such.that the applicable opacity standards_ in 15A NCAC 2D .0521 "Control of Visible. Emissions" or 15A. NCAC 2D .0524 "New Source.. Performance Standards" are not exceeded. There were.no visable..einissions above the opdcity limits observed during the compliance inspection. There were no fugitive dust emissions observed: beyond the property boundary. , A water tru0 was in .use during the.inspection. Compliance is indicated 3. Specific Condition and Limitation No. A.5. states that.the primary crusher rs. a "jaw" crusher rated at 700 tons per hour at.8 inch crusher setting per the manufacturer's specifications as submitted Any change from this crusher definition, other than like=for=like; will require a permit application to be submitted: The purpose of this stipulation is to characterize the•primary crusher and not limit. production. No changes were made to the crusher: Compliance is indicated 4. Specific .Condition and Limitation No. A.' 6. "Visible Emissions Control Requirement" as required by 15A NCAC 2D .0521, "Control of Visible Emissions" states that visible emissions from the emission sources, manufactured after July. 1, 19-74.sha11 not be more than 20 percent opacity when averaged over a six -minute period.. There were no visible emissions above 5% opacity during the inspection. 'Compliance is indicated 5. Specific Condition and Limitation No. A. 7. "Visible Emissions Control Requirement" as required by 15A NCAC 2D .0521, "Control of Visible Emissions" states that visible emissions from the emission sources, manufactured as of July 1, 1971, shall not be more than 40 percent-opacity.when averaged over a six -minute period. There were no visible emissions above 5% opacity during the inspection. Compliance is indicated Vulcan Construction Materials, LP —Gold Hill . September 7, 2016 Page 10 6. 'Specific Condition and Limitation No. A. 8. as required by 15A NCAC 21 .0524'NNew Source Performance Standards" states that NSPS affected sources commence construction, reconstruction, or, modification after August 31, 1983, mustcomply with notification, testing, reporting, record keeping, and monitoring requirerrients as promulgated in 40 CFR, Part 60, Subpart 006, including Subpart A, "General Provisions". The NSPS notification requirements state that the Permittee must notify the DAQ in writing of the date construction or reconstruction of an affected facility commenced, postmarked no later than thirty (30) days after such date;'and the actual date of initial start-up of an affected facility, postmarked within fifteen (15) days after, such date. The facility has submitted the above referenced notifications within the required time frame; therefore, compliance is indicated The NSPS visible :emissionslmiitations;are as follows: 15%. opacity oil criisliers; 10% opacity for conveyor belts and screens; and 0%.opacity for process saturated materials from conveyor belts and other affected facilities such as screens. During theInspection, there were, no visible emissions above. the opacity limits listed under [his condition. Compliance is indicated `Facilities that commenced construction, modification, or reconstruction on or after April 22, 2008 that use wet suppression to .control emissions must conduct monthly inspections of the wet suppression systems. Each inspection and any corrective action must be recorded in a logbook. This facility was. constructed prior to 2008; therefore,.they are not required to conduct'monthly inspections. The facility still conducts the inspections weekly and record in'a logbook Compliance is indicated. Within 60 days after achieving the maximum_ production rate at which the NSPS affected sources will be operated, but no later than 180 days after the initial start-up of the affected "sources, the Permit -tee is required lto conduct visible emissions evaluations (EPA Reference Method 9)-on the NSPS affected. facilities and submit a written report to MRO DAQ. . The facility has conducted the required visible emissions tes"ting.(EPA Reference Method 9) on the subject crushang, screening, and conveying equipment within the required time frame Compliance is indicated, , 7. Specific Condition and Limitation No. A. 9. "Notification Requirement" -as required byNCAC 2D .0535, the Permittee of a source of excess emissions that last for more than four hours and that results from a. malfunction, a breakdown of process or control equipment or any other abnormal conditions, shall notify. the Director or his' -designee of any such occurrence by 9:00 a.m.. Eastern time of the Division's next business day, bf becoming aware of.the occurrence: Based on a records review and conversaf im with Mr. Litiauer, no excess emissions have occurred at the facility since the last inspection; therefore, compliance is indicated Vulcan Construction Materials, LP — Gold Hill September 7, 2016 Page 11 8. Specific Condition and Limitation No. A. 16. as required by 15A NCAC 2D .0540 "Particulates From Fugitive Non - Process Dust Emissions Sources" states that the Permittee. shall not cause or allow fugitive non -process dust emissions to cause or contribute to substantive complaints. This company is utilizing'a water truck to wet the roads at this facility. There have not been any dust complaints for this facility since the last inspection was conducted The roads appeared to be wet during the inspection, and there was no dust observed beyond the property line. therefore, compliance is indicated GACT/MACT Review As was -indicated in the previous inspection the facility has replaced their diesel -fired pit pump with an electric pump; therefore, they do not appear to be subject to the requirements of the RICE MACT — Subpart ZZZZ. Summary of changes needed to the current permit: None Compliance assistance offered during the inspection: None Section 112M-4pplicability: This facility does.not appear to be subject to the requirements of the Chemical Accident Release Prevention Program, Section 112(r) of the Clean Air Act. Compliance determination: Based on my.observations, this facility appeared to be in compliance with the applicable air quality regulations at the time.of.the inspection. OT:lhe c: MRO File G:\AQ\Shared\WPDATA\COUNTIES\CABARRU8\00067\INSPECT 20160907 Mulfimedia.docx i _ '. �`: .. .. _ ,. _� i �, ,; � .. ., � Compliance Inspection Report . Permit: NCG020108 Effective: 10/01/15 Expiration: 09/30/20 Owner: Vulcan Construction Materials LLC SOC: , Effective: Expiration: Facility: Vulcan Construction. Materials -Gold Hill County: Cabarrus 16745 Old Beatty Ford Rd Region: Mooresville Gold Hill NC 28071 Contact Person: Tony Johnson Title: Phone: 704-547-7076 Directions to Facility: System Classifications: Primary ORC:' Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 09/07/2016 Entry Time: 09:30AM Exit Time: 12:45PM Primary. Inspector: Od A Tuvia Phone: 704-663A 699 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 I permit: NCG020108 Owner - Facility: Vulcan Construction Materials LLC Inspection Date: 09/07/2016 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Site is in compliance. r '0. . Page: 2 permit: NCG020108 owner - Facility: Vulcan Construction Materials LLC Inspection Date: 09/07/2016 Inspection Type: Compliance Evaluation Reason for Visit: Routine Analytical Monitoring Yes No NA'NE Has the facility conducted its Analytical monitoring? ❑ ❑ ❑ # Has the facility conducted its Analytical -monitoring from Vehicle Maintenance areas? ❑ ❑ ❑ Comment: Analytical monitoring done has required. Permit and Outfalls Yes No NA NE # Is' a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ # Were all outfalls observed -during the inspection? 0 ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? 0 ❑ ❑ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ❑ ❑ ❑ Comment: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ❑ 0 ❑ Comment: Not required no storm water. Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ❑ : ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? 0 ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? E ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ E ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? 0 ❑ ❑ ❑ # Does the Plan include a BMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ❑ ❑ ❑ # Does the facility provide and document Employee Training? 0 ❑ ❑ ❑ # Does the Plan include.a list of Responsible Party(s)? A 0.11 ❑ # Is the Plan reviewed and updated annually? ❑ ❑ ❑ # Does the Plan include a Stormwate.r Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: Storm Pollution Prevention Plan was last updated on October 2015. Page: 3 NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WASTE MANAGEMENT (DWM) HAZARDOUS WASTE SECTION (HWS) l COMPLIANCE BRANCH RCRA INSPECTION REPORT 1. Facility Information: Vulcan Construction Materials, LP — Gold Hill 16745 Old Beatty Ford Road Gold.Hill, NC 28701 EPA ID#: NCS000002366 2. Facility Contact: Mr. Jordan Littauer Phone: 704-246-5566 3. HWS-Inspectors: Ori Tuvia, NCDEQ/MRO/DWR- Engineer 4. Date/Time of September 7, 2016 Arrived: 09:30 am — Departed: Investigation: 12:45 pm . Date of Report: September 14, 2016 - Prepared By: OriTuvia 5. Participants: Mr. Jordan Littauer, Plant Manager, Mr. Tony Johnson, Environmental. Engineer, and Ori Tuvia, Engineer MRO 6. Purpose of Inspection: Multimedia Compliance Evaluation Inspection 7. Report: On September 7, 2016, a.multimedia inspection at the Vulcan Construction Materials -Gold Hill quarry was conducted. The facility is an active quarry. The facility is currently operating as a Conditionally Exempt Small. Quantity Generator (CESQG). A tour of facility operations was conducted during the visit. The facility generates used oil. Used oil is accumulated in an above ground tank. The tank is located within a secondary containment structure. Tank was properly labeled at the time !of the inspection. Used oil is pumped out as needed, oil was last pumped on 7/19/2616 by Heritage Crystal Clean (EPA ID # ILR000130062). Used florescent light bulbs are stored properly, within a closed box, for disposal. 8. Deficiencies/Violations: None 9. Comments: Although the, facility primarily opexates as a conditionally exempt small quantity generator (CESQG) of hazardous waste, it is a reminder that if the facility generates more than 220-pounds of total hazardous waste in any calendar month, or accumulates more than 2,200-pounds of hazardous waste onsite at any one time, the facility will be subject to small quantity generator (SQG) regulations.. SQG hazardous waste regulations are listed in Title 40, Code -of Federal Regulations, Part 262.34 (c) & (d). If the facility generates more than 2,200-pounds of hazardous waste in any calendar month or accumulates more than 2.2-pounds of acutely toxic (P-Listed) hazardous waste onsite at any one time the facility will.be subject to full regulation as a large quantity generator , (LQG). LQG hazardous waste regulations. are listed in Title 40, Code of Federal Regulations, Part 262. Additionally, LQGs and SQGs must obtain a site EPA Identification Number before offering hazardous waste for off: site transport and disposal. Guidance documents for hazardous waste generators can be found at: h{tp.'H ortal.ncdenr.org/web/wm/hw/Technical Ori Tuvia, Environmental Engineer Mooresville Regional Office Division of Water Resources, DEQ